RATE INPUTS Input B (Terminal 2) Low speed input designed for contact closures to DC common PHYSICAL. Speed: O-20 Hz Operation Temperature: 0-55 C

Similar documents
We put you first. And keep you ahead. USES FEATURES. Bulletin SS09040 Issue/Rev. 0.2 (10/14)

User s Guide MWTC-REC6/UWTC-REC6. Wireless Transceiver. Shop online at omega.com SM

201AN DC VOLTMETER 201AN-AC VOLTMETER

Model Number Structure

User s Guide DP301AN DC VOLTMETER DP301AN-AC VOLTMETER. RoHS 2 Compliant.

True RMS AC/DC Mini Clamp Meter

Instruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

User s Guide CL542-PLUS. Automated Thermocouple Calibrator. Shop online at

SCALE & WEIGHT DISPLAYS

STD-525T PRECISION TIMER

BASIC PH METER BASIC PH METER KIT

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

ZIG-POEPRO-70A. HDBaseT HDMI Extender

User s Guide HHP241 SERIES. Digital Manometer. Shop online at. omega.com For latest product manuals: omegamanual.

TABLE OF CONTENTS SPECIFICATIONS...1 MOUNTING...3 WIRING...4 THEORY OF OPERATION...6 MILIVOLT INPUT OPTION JUMPER SELECTIONS...7

Model R177M and R177S Baseband Switch

Sprite TL Quick Start Guide

ZIG-POC-100. HDBaseT HDMI Extender

BC104 BATCH CONTROLLER

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016

LBS-1 (Lowrance Broadband Sounder)

Electronic M.O.P Card. Instruction Manual Model D

Global Water Instrumentation, Inc.

GRT SERIES INSTALLATION & OPERATING INSTRUCTIONS

DisplayPort Extender over 2 LC Fibers

Table of Contents. Introduction Pin Description Absolute Maximum Rating Electrical Specifications... 4

APSPB PUSH BUTTON ZERO Installation Manual

Modular Lube Lubrication Systems System Controls

USERS GUIDE MCX-HTS. HDMI to 3G SDI Converter. Manual Number:

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

User s Guide OMEGASCOPE OMSP-2000 SERIES. PC Oscilloscopes

Please take a few minutes to read this manual so that you will better understand the featues and capabilities of your MF80. MF80 Owner s Manual 1

Metal Electrode Meter

User s Manual. Model Digital Sound Level Meter

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

DICKSON ES120/ES120A DICKSON. Electronic Signal Data Logger. Specifications. Applications, Features, & Getting Started. Instructions / Operating

Master Time Clock MTC Users Manual

ARS x4 MATRIX SWITCHER Instruction Manual

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR

User s Guide PX5100. Shop online at omega.com SM. Quick Start Function Summary Instructions for OMEGA PX5100 Rangeable Pressure Transmitter

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Zigen ZIG-PAX. Premium Digital / Analog Audio Extender. 4K 60 Hz 4:4:4 HDCP 2.2 ZigNet, Full Web Interface and System Diagnostics

Users Manual. Stroboscope. September 2014

LED Series Sealed Backlights

SyncGen. User s Manual

*Prefer. 600 MHz 4K ULTRA. 60Hz, 4:4:4. over one SC-Terminated Fiber-Optic Cable EXT-DP-4K600-1SC. User Manual. Release A1

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

LAUREL ELECTRONICS, INC.

CS x1 RS-232 Computer Controlled Video Switcher. Instruction Manual

PulseFlow FP100 Pulse to 4 20mA Flow Converter (Flow Rate Transmitter / Totalizer / Indicator)

TR-2 OPERATION MANUAL

DisplayPort Extender over 2 LC Fibers

Instruction Manual Model # Block Upconverter

User Manual. Model 1351 DVI Repeater with HDCP

Fits the Leopard Family FREQ./RPM INPUT MODULE WITH 24 V EXC.

Instructions. P MHz 1X/10X Passive Probe

Model: UHD41-ARC. Installation Guide

Sport-TIMER 3000 TM Instruction Manual

INTRODUCTION INSTALLATION LIGHTNING RETARDING LOOPS. Figure 1. Relay Box Antenna Connections. Relay Box Cable Connections

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

ST-4000 SIGNAL LEVEL METER

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Table of Contents 5.0 WARRANTY. 1.0 Introduction Unpacking 1.2 Repacking and Storage

16-BIT LOAD CELL/DUAL STATUS INPUT

TeckNet HDMI03-V2 Switch. User Manual

32 Channel CPCI Board User Manual

VK-P10SE WARRANTY REGISTRATION FORM

User Manual. Model 979T and 979R Digital Audio Converters

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

autotwo Automatic Mixer Operation Manual

Q3X Laser Contrast Sensor

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)

ST-4000D SIGNAL LEVEL METER

Model P/03P Upconverters

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Electronic Pulse Counter Combination device

Q3X Laser Contrast Sensor

User s Guide. PHB-900 Series. ph Benchtop Meters.

MLA-XLR MIDI Line Amplifier

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

COMPOSITE VIDEO (BNC) TO VGA VIDEO FORMAT CONVERTER AND SCALER AT-RGB110

OUR MISSION. THE COMPANY.

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

Utility Amplifier GA6A Model

Kramer Electronics, Ltd.

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course!

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

3M Sensored Termination (15 kv) QX-T15I-vi1-E

RMX-44 & RMX-62 MIXING MATRIX. Installation & Operation Manual

Warner Photoscanner MCS-500 Series LED Photoelectric Control

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

Multifunction Digital Timer

Model /29S RF Splitter

Installation and Operation Manual. for the. SM-6 Programmable Stereo Mixer

Transcription:

DPCI 0-RM Ratemeter Ml 665/0693 2.677 (68mm) IW Recommended Panel Cutout T1.299 (33mm) POWER DC COMMON (Terminal 1) Internal battery: 3V, lithium Life expectancy: 5 years + RATE INPUTS Replacement Part: DPClO,.BAT Input B (Terminal 2) Low speed input designed for contact closures to DC common PHYSICAL Speed: O-20 Hz Operation Temperature: 0-55 C Minimum Low Time: 10 milliseconds Storage Temperature: -20-70 C Minimum High Time: 40 milliseconds Operating Humidity: 90% hlon-condensing Impedance: 101 kr Weight: 2.2 oz. net Voltage Thresholds: Low 0 to 0.4 V dc Display Size:.43 high High 2.0 to 28 V dc Front Panel Rating: NEMA,4X when mounted Maximum High 28 V dc with gasket provided Case Material: Cycolac X-l 7 Input A (Terminal 3) High Speed Input requiring a voltage source such as a current sourcing sensor or a current sinking RATE INDICATOR sensor used with the provided pull up resistors. Type: l/tau Speed: 0 to 10 khr Digits: 4/5 (4 calculated, 5 displayed with fixed 0 in LSD) Minimum Low Time: 80 microseconds Scaler Range:.OOl to 9999 Minimum High Time: 20 microseconds Decimal Point: 5 positions, programmable (The above times are with a 0 to 5.0 V swing) Accuracy: +0.2% Input Imedance: 2KR above 5 V dc Update Time:.7 set Voltage Thresholds: Low 0 to 1.2 V dc Zero Time: 10 seconds High 2.0 to 28 V dc Maximum High 28 V dc PROGRAM ENABLE INPUT (Terminal 5) Operation: Level sensitive (maintained)

INTRODUCTION Your OMEGA DPCl 0-RM is a ratemleter with a 4-5 digit LCD display. The four most significant digits are calculated; five digits will be displayed with fixed0 in ithe least significant digit. A programmable rate scaler and #decimal point allow for display of rate in any engineering term. Plastic front panel sealed to meet NEMA-4X - FRONT VIEW 4-5digit LCD Display OPERATION Rate Inputs Separate contact and solid state inputs are provided. The solid state input (terminal 3) requires a current-sourcing sensor and can accept inputs up to 10 khz. Inputs into this terminal are realized on the positive-going edge. Input realized on this edge of the pulse (Voltage applied to terminal) J Mode select/ Programming button Program enable APPLICATIONS The DPClO-RM is designed to show you process rate. You must make certain programming alid wiring choices to accomplish your application. W e recommend the following sequence: 1. Answer the following questions: What type of sensor will be used? What engineering units shoulcl the ratemeter be scaled to? How many pulses per item is the sensor providing? Is a decimal point needed on the rate display? 2. Calculate the rate scale factor. MOUNTING +--- 2.677 (67mm) Y RBcOmmended Gasket Installed? Terminal 3 is pulled down to common. When a sensor output supplies voltage to this terminal, one count is registered on the display. The sourcing signal must supply at least +2.0 V dc but no more than +28 V dc. Note: W hen a sourcing signal is applied to terminal 3, a power assist feature of the DPCl 0-RM extends the life of the battery. Terminal 2 is the low-speed, current-sinking rate input designed to be used with a contact closure to ground. It has a maximum count speed of 20 Hz. Inputs into this terminal are counted on the negative-going edge. Terminal 2 is pulled up to +3 V dc. When a contact closes, pulling the voltage down to.4 V dc or less, one count is registered. PROGRAM MODE NOTE: To enter the program mode, you must connect a jumper between terminals 1 and 5. To leave the program mode, disconnect the jumper. Screens There are three program-mode screens in thedpclo-rm. Press and hold them key while repeatedly pressing the m key to advance to successive screens. I Contact Closes Programming Screens Contact Opens Screen Function 1 Rate Scale Factor 2 Ratemeter Decimal Point 3 Rate xl /xl 0 I 1 l lnstall mounting clip Page 2

RATE SCALER Calculating the Rate Scale Factor This lmau ratemeter calculates rate by measuring the time interval between input pulses, converting to a frequency (F = l/tau), and multiplying the product by the rate scaler. The rate scaler is user programmed to convert the count input frequency into the desired rate units for display (feet/minute, inches/second, gallons/hour, etc.) Programming Rate Scale Factor The first program mode screen allows you to enter the rate scale factor. Rate Scaler Range: 0.001 to Rate Scaler (RS) formula: 999!) The lower case d appears on the right of the display when it is time to enterthe decimal point position for the rate scaler. RS= where: SEC X DPF PPI SEC is the number of seconds in the rate time unit (items/ second = 1, items/minute = 60, items/hour = 3600, etc.) DPF is the decimal point factor cormresponding to the desired decimal point location on the run mode screen: Display DPF xxxx 1 xxx.x 1 0 xx.xx 100 x.xxx 1000 Note: This decimal point is used for the rate scaler only and will not appear on the ratemeter screen. Press the m key to change the first digit to the correct value. Press the m key to select the next digit to be changed. Repeat this process until all the digits are correct. When the d appears, press them key until the decimal point is in the desired location. Ratemeter Decimal Point The second program mode screen is used to enter the decimal point position for the ratemeter run-mode display. Use the rate display decimal point screen to program the desired decimal point position. PPI is the number of pulses per item from the sensor. Example 1: A sensor produces 10 Ipulses perfoot of material travel. Display rate in whole feet per minute (XXXX). RS= 60x 1 60 -=-_=6 10 10 Example 2: A flow sensor produces 400 pulses per gallon. Display flow rate in tenths of gallons per hour (XxX.X). 3600 x 10 36,000 RS= = - = 400 400 90 Press them key until the decimal point is in the correct position. Rate xl or xl 0 The third screen is used to select the rate display multiplier of one or ten. Selecting rate x10 will add a zero to the far right of the display. This zero will not change value and does not affect the decimal point position. Press the m key to select 1 or IO. Note: To exit the program mode, disconnect the jumper between terminals 1 and 5. Page 3

OMEGA... Your Source for Process Measurement and Control TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies w Wire: Thermocouple, RTD 8. Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers PRESSlJRElSTRAlN FORCE jij Transducers & Strain Gauges & Load Cells & Pressure Gauges Displacement Transducers Q Instrumentation & Accessories FLOW/LEVEL m Rotameters, Gas Mass Flowmeters E Air Velocity Indicators TurblIne/Paddlewheel Systems Totalizers & Batch Controllers ph/copiductivity + ph Electrodes, Testers & Accessories m BenchtoplLaboratory Meters Controllers, Calibrators, Simulators & Pumps B Industrial ph & Conductivity Equipment DATA ACQUISITION Data Acquisition and Engineering Software B Communications-Based Acquisition Systems B Plug-in Cards for Apple, IBM & Compatibles Q Datatogging Systems Recorders, Printers & Plotters HEATERS w Heating Cable B Cartridge & Strip Heaters Immersion & Band Heaters m Flexible Heaters Laboratory Heaters & Flow Computers OMEGA ENGINEERING INC. One Omega Drive, P.O. Box 4047 Stamford CT 06907 Tel: (203) 359-l 660 Telex: 996404 Cable OMEGA. Fax: (203) 359-7700

WIRING RECOMMENDATIONS Following these suggestions will increase noise immunity and lengthen unit life. WIRING DIAGRAMS CONTACT CLOSURE RATE INPUT Cable: Make the connection between the count source and the ratemeter with a two-conductor shielded cable. Connect the shield to earth ground at one (?nd only. Relay Coil Suppression: If a relay contact is used as a count source, suppress the relay coil. This can be accomplished with an RC network for AC coils or a diode for DC coils. Mounting: Do not mount the ratemeter near a solenoid or other inductive devices. Supply enough ventilation to keep the ratemeter operating within the temperature specifications. Do not mount this unit in a heavy vibration area. SOLID STATE RATE INPUT CURRENT SOURCING SENSOR /, RST4 tna3 3 0 5 Enable/R IN82 GNDl 9 BATTERY SAFETY The lithium battery that powers ycur device contains inflammable materials such as lithium organic solvent, and other chemical ingredients. Explosion or fire may result if the battery is not handled correctly. To avoid an accident, follow these guidelines: Do not stack or jumble up batteries Do not 1heat batteries above 95% Do not disassemble batteries Do not recharge lithium batteries Do not apply pressure to, or deform batteries Do not solder to batteries Do not dispose of batteries in fire Insert battery with correct polarity Terminal Function Operatioln 1 Ground 2 Input B Use with IContact Closure to Ground Rate Input Maximurri 20 Hz Count Speed 3 Input A Use with Current Sourcing Sensor Rate Input Maximurr 10 khz Count Speed 4 Not Used SOLID STATE RATE INPUT CURRENT SINKING SENSOR ri,0 5 Enable/R /- 5 Enable/R GNDl 9 * Not suitable for direct turbine meter or direct self-generating paddlewheel input. PROGRAM MODE ENABLE \ RST4 3V p-p min - 20V p-p max INA INB2 GNDI 9 Current Sinking SOLID STATE RATE INPUT Sensor MAGNETIC PICKUP RST4 INA IN82 $ 1 5kR +6 to +28 VDC 5 Program Connect ito Ground to Enter Enable Program Mode B5 Enable/R INB2 t-i Page 4

REPLACEMENT PARTS OTHER OMEGA MINI COUNTER PRODUCTS DPCl O-BAT Battery 46066-210 Gasket 53300-241 Mounting Clip 28772-200 Mounting Screw DPCl 0-TL DPCIO-CS DPCI O-CC DPCl 0-QT DPClO-RT Totalizer Add/Subtact Totalizer (Solid State Input) Add/Subtract Totalizer (Contact Input) Quadrature Indicator Ratemeterflotalizer ~~~~~~~~~~~~~~?. ::~.~<:~ :.~~~,..c w 3:. ~ WAR RA NW : ;,++ ;:<!. ;;~~~~~~~~~j81;57 : ; >,:,<,, OMEGA warrants this unit to be free of defects in materials and workmanship and to give satisfactory service for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) Year product warranty to cover handling and shipping time. This ensures that our customers receive maximulm coverage on each product. lfthe unit should malfunction, it must be returned to the factory for evaluation. Our Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. However, this WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA s control. Components which wear or which are damaged by misuse are not warranted. These include contact points, fuses, and triacs. We are glad to offer suggestions on the use of our various products. Nevertheless OMEGA only warrants that the parts manufactured by it will be as specified and frsle of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHAT!IOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE AND IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FIITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. ALL LIMITATION OF LIABILITY: The remedies of buyer set forth herein are exclusive and this total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. Every precaution for accuracy has been taken in the preparation of this manual, however, OMEGA ENGINEERING, INC. neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages that result from the use of the products in accordance with the information contained in the manual. < ;:& ;&$ RETURN REQUESTS INQU Direct all warranty and repair requests/inquiries to the OMEGA ENGINEERING Customer Service Department. Call toll free in the USA and Canada: l-800-622-2378, FAX: 203-359- 781 1; lnternational:203-359-1660, FAX: 203-359-7807. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, YOU MUST OBTAIN AN AUTHO WFD I- FROM OUR CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside ofthe return package and on any correspondence. Please have the following information available BEFORE contacting OMEGA: 1. P.O. number under which the product was PURCHASED, 2. Model and serial number of the product, and 3. Repair instructions and/or specific problems you are having with the product. OMEGA s policy is to make running changes, not model changes, whenever an improvement is possible, That way our customers get the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. IRlES ~::~~& ::~t:.. 0 Copyright 1993 OMEGA ENGINEERING, INC. All rights reserved including illustrations. Nothing inthismanualmaybereproducedinanymanner,eitherwhollyorinpartforanypurpose whatsoever without written permission from OMEGA ENGINEERING, INC. Printed in U.S.A. / r; Page 5