LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

Similar documents
Linear flow controls VFC Linear flow controls with actuator IFC

Gear Pump Units For single-line centralized lubrication systems

Linear flow control with actuator IFC

Gear Pump Units. For single-line lubrication systems

Sensor technologies Proximity sensors Series ST4. Brochure

Level Measurement silometer FMC 420, FMC 423

Lt DELTA USA, Inc

Inductive sensor BI1.5-EG08K-Y1

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Product Data Sheet

istep STEPPER MOTOR PUMP

RKSlimlift / EM. Two-stage lifting column

CAVEX hygienic. Stainless steel gearboxes and gearmotors.

RW45 Motor Gearboxes:. Drive torques up to 120Nm at 50 Hz and 60 Hz mains frequencies;

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Frequency Converter Fv

Inductive sensor NI3-EG08K-Y1-H1341

Product Data Sheet 4656 EZ

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

TWIN-PUMP. Dual line system. Designed to work all the day, every day in extreme condition and difficult environments

Phone Horizontal Multistage Pumps Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Meteor Product Catalogue

GRUNDFOS alldos product information. The solution for complex dosing tasks

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

High performance circuit breakers

Modular Lube Lubrication Systems System Controls

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

istep STEPPER MOTOR PUMP

Process transmitter RMA422

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Single Point Flow Monitor SW118 SW119

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Scanning System S-2100

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Label Applicator HERMA 400

Circuit-Breakers for Motor Protection Series 8523/8

Inductive sensor NI10-M18-Y1X-H1141

Capacitance Limit Detection nivotester FTC 420/421/422

ErP ROOF UNITS - ROOFMASTER STOF VERTICAL FEATURES ELECTRICAL SUPPLY AMBIENT TEMPERATURE RANGE SIZES MATERIAL AND DESIGN

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Absolute Encoders Multiturn

OPTOTRONIC Intelligent

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Product Data Sheet 4650 N-465

Speed sensor MiniCoder GEL 2471

2.9 Sigma/ 2 Plunger Metering Pumps

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

BERNSTEIN Double Insulated Position Switch I49

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Magnetic Stirrers Magnetic Stirr

KRF EMC Filters Installation, Operation and Maintenance Manual

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Panel-mounting Thermostats EM Series

Panel-Mounted Thermostat

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

Okta 1000, Roots pump without motor

Capacitive sensor BCT5-S18-UP6X2T-H1151

PRODUCT DATASHEET QTi DALI-T/E 2X18 42 DIM

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

Series description: Wilo-Drain VC

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Varia Tube THE SMALL AND POWERFUL CHAIN ACTUATORS RANGE

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DATA SHEET Panorama Rudder Indicator, TRI-2

Revision 1.0 Parts List Salvador 1~, 3~

Model KT 53 Cooling incubators with thermoelectric cooling

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Capacitance Level Measurement Electronic insert FEC 12

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Product Data Sheet 4656 ZW

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

SERIES 400 SERIES 620

Revision 2.0 Parts List Minor

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Revision 1.0 Parts List Minor

TECHNICAL INFORMATION

Flexibility and Safety. BERNSTEIN safety hinge switches

Electrical connection

Panel-mounting thermostats, type series EM

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through

Read/write head TN-M18-H1147

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Linear encoders without bearings incremental System for linear motion feedback

Read/write head TN-CK40-H1147

Electrical connection

Part-Turn Electric Multi-Turn Electric

Pluggable interface relays CR-M Miniature relays

Transcription:

LINEAR ACTUATORS Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

moving As one of the leading manufacturers of electrical and electronic drive components and systems we offer you a wide product range for almost every industrial application in many different branches of industry. Innovative products and our sound technical competence have made us a reliable partner for 60 years. We understand our customers problems and find individual solutions. lift position S / SH 95 The powerful S / SH 80 The universal S / SH 71 The versatile S / SH 56 The compact Page 4 Page 8 Page 12 Page 16 2

ideas Our experience and orientation towards the future provide the foundations for our ambitious strategies. From our manufacturing site in Germany as well as our international sales offices we deliver HANNING products and service to successful companies all over the world. moving ideas With this slogan we present ourselves on the market. It represents our aim to develop and produce modern and economic drive solutions for our customers. move control Linear actuators The control unit CTRL Page 20 Spindle drives of the S series with open spindle and drives of the SH series in encapsulated design are available in four different sizes with winding diameters of 56, 71, 80 and 95 mm. Both the electronics and the construction of the drives can be perfectly adapted to your requirements. The main field of applications are in medical technology and industry. 3

S 95 / SH 95 linear actuators The Powerful The linear actuators of the S 95 and SH 95 series have a compact design. They are available as single-phase devices with 230 V and as three-phase variant with 400 V. Powerful single-phase and three-phase AC motors with a winding diameter of 95 mm provide large traversing forces and virtually constant traversing speeds even under load changes. In thermally harsh environments bronze gearboxes can be used. Of course, we perfectly adapt the power, design and traversing speed of the S 95 and SH 95 actuators to your individual application. The linear actuators of these series are also available as low-voltage three-phase AC system with frequency inverter (DC-FI system). Please ask for our DC-FI brochure. Linear actuator type S 95 Linear actuator type SH 95 Features Powerful single-phase AC motors, three-phase AC motors or low-voltage three-phase drives (DC-FI) Almost constant traversing speed under load variations Windings adapted for the application with HANNING frequency inverters Compact design thanks to a worm gearbox integrated into the motor end shield High-efficiency plastic gears Ambient temperatures between -20 C bis +50 C possible Individual stroke lengths adapted to the application Individual control options Rugged TR20 acme thread Mechanical locking device at end positions Approved according to DIN EN 60601, UL 50501, CSA 60601 Optional equipment Micro switch integrated into SH 95 as limit switch Hall IC to detect a position at up to 4500 pulses per minute at rated motor speed (rotor speed acceptance) Bronze gearbox for high ambient temperatures Hexagon socket in motor shaft for adjusting the drive when no current is applied Travel tube in nickel plated V2A steel or aluminium for type SH 95 Customer-specific spindle nuts, travel tubes and receptacles Mirrored spindle and travel tube positions possible Special design with spindle through the fork joint Special design with standing spindle and traversable drive 20 mm diameter acme thread spindles with, as single, double and tripple threaded type Windings adapted to different core widths and defined preferred directions Free-wheeling function Fork joints according to DIN 71751 4

Technical data S 95 / SH 95 Mains voltage Mains frequency Max. traversing force Traversing speed Spindle length (S 95) Stroke length (SH 95) 1~ 100 / 115 / 230 V AC ±10% / 3~ 400 V 50-60 Hz 12,000 N (industrial applications) or 10,000 N (medical applications) 3,5-75 mm/s on request on request / standard: 100, 200, 250, 300 and 500 mm Class of protection 1 Type of protection Duty time Control End position limiters Position detection IP00 - IP41 25 s on / 400 s off electrical via HANNING control unit CTRL via HANNING frequency inverter via low-voltage switching system mechanical end limiters Limit stop via internal micro switch (only SH95) Hall sensor Force-speed diagram 100 / 115 / 230 V single-phase 50 / 60 Hz kn 12 11 10 9 8 7 6 5 4 3 2 1 50 Hz 60 Hz 7 11 14 21 28 42 63 8 13 16 25 33 50 75 mm/s Force-speed diagram 400 V three-phase 50 / 60 Hz kn 12 11 10 9 8 7 6 5 4 3 2 1 50 Hz 60 Hz 14 17 21 25 28 33 42 50 63 75 mm/s 5

Dimension sheets S 95 S 95 x = Free spindle length A, B, C, D = Cable outlet V = Vertical fork joint H = Horizontal fork joint Option: Fork joint S 95 / SH 95 Option: Travel tube S 95 Option: Spindle nut S 95 6

Dimension sheets SH 95 SH 95 x = Installation length retracted y = Installation length extracted z = Overlap (load and stroke dependent, as of 300 mm stroke length) A, B, C, D = Cable outlet V = Vertical fork joint H = Horizontal fork joint SH 95 with limit switch x = Installation length retracted y = Installation length extracted z = Overlap (load and stroke dependent, as of 300 mm stroke length) A, B, C, D = Cable outlet V = Vertical fork joint H = Horizontal fork joint 7

S 80 / SH 80 linear actuators The Universal The compact linear actuators of the S 80 and SH 80 series are available as single-phase devices with 230 V. Powerful AC motors with a winding diameter of 80 mm provide large traversing forces. High efficiency can be achieved by choosing a preferred direction for the drive. The linear actuators of these series are also available as low-voltage three-phase AC system with frequency inverter (DC-FI system). Please ask for our DC-FI brochure. It is however possible to perfectly adapt the windings, spindles and preferred direction of S 80 and SH 80 linear actuators to your individual application. Linear actuator type S 80 Linear actuator type SH 80 Features Powerful single-phase AC motors or low-voltage three-phase drives (DC-FI) Almost constant traversing speed under load variations Compact design thanks to a worm gearbox integrated into the motor end shield Ambient temperatures between -20 C and +50 C possible Individual stroke lengths adapted to the application Individual control options High efficiency plastic gears Mechanical locking device at end positions Approved according to DIN EN 60601, UL 50501, CSA 60601 Optional equipment Micro switch integrated into SH 80 as limit switch Hall IC to detect a position at up to 4500 pulses per minute at rated motor speed (rotor speed acceptance) Customer-specific spindle nuts, travel tubes and receptacles Aluminium travel tube for type SH 80 with individual connection Mirrored spindle and travel tube positions possible Special design with spindle through the fork joint Special design with standing spindle and traversable drive Acme thread spindles with diameters between 12.5 mm and 16 mm, as single and double threaded type Windings adapted to different core widths and defined preferred directions Free-wheeling function 8

Technical data S 80 / SH 80 Mains voltage 1~ 100 / 115 / 230 V AC ±10% Mains frequency Max. traversing force Traversing speed Spindle length (S 80) Stroke length (SH 80) 50-60 Hz 8,000 N 3-24 mm/s on request on request / standard: 100, 200, 250 and 300 mm Class of protection 1 Type of protection Duty time Control End position limiters Position detection IP00 - IP41 25 s on / 400 s off electrical via HANNING control unit CTRL via HANNING frequency inverter via low-voltage switching system mechanical end position limiter Limit stop via internal micro switch (only SH 80) Hall sensor Force-speed diagram 100 / 115 / 230 V single-phase 50 / 60 Hz kn 10 9 8 7 6 5 4 3 2 1 50 Hz 60 Hz 6 7 10 12 15 18 20 24 mm/s 9

Dimension sheets S 80 S 80 x = Free spindle length A, B, C, D = Cable outlet V = Vertical fork joint H = Horizontal fork joint Option: Fork joint S 80 / SH 80 Zinc-diecasting Aluminium-diecasting Aluminium-diecasting Polyamid Polyamid Option: Travel tube S 80 Option: Spindle nut S 80 10

Dimension sheets SH 80 SH 80 x = Installation length retracted y = Installation length extracted z = Overlap (load and stroke dependent, as of 300 mm stroke length) A, B, C, D = Cable outlet V = Vertical fork joint H = Horizontal fork joint SH 80 with limit switch x = Installation length retracted y = Installation length extracted z = Overlap (load and stroke dependent, as of 300 mm stroke length) A, B, C, D = Cable outlet V = Vertical fork joint H = Horizontal fork joint 11

S 71 / SH 71 linear actuators The Versatile The linear actuators of the S 71 and SH 71 series are available as single-phase devices with 230 V. A winding diameter of 71 mm provides the compactness required for many applications. The linear actuators of these series are also available as low-voltage three-phase AC system with frequency inverter (DC-FI system). Please ask for our DC-FI brochure. It is however possible to perfectly adapt the spindles and winding characteristics of S 71 and SH 71 actuators to your individual application. Linear actuator type S 71 Linear actuator type SH 71 Features Powerful single-phase AC motors or low-voltage three-phase drives (DC-FI) Almost constant traversing speed under load variations Compact design thanks to a worm gearbox integrated into the motor end shield Ambient temperatures between -20 C and +50 C possible Individual stroke lengths adapted to the application Individual control options High efficiency plastic gears Mechanical locking device at end positions Approved according to DIN EN 60601, UL 50501, CSA 60601 Optional equipment Micro switch integrated into SH 71 as limit switch Hall IC to detect a position at up to 4500 pulses per minute at rated motor speed (rotor speed acceptance) Customer-specific spindle nuts, travel tubes and receptacles Aluminium travel tube for type SH 71 with individual connection Mirrored spindle and travel tube positions possible Special design with spindle through the fork joint Special design with standing spindle and traversable drive Acme thread spindles with diameters between 12.5 mm and 16 mm, as single and double threaded type Windings adapted to different core widths and defined preferred directions Free-wheeling function 12

Technical data S 71 / SH 71 Mains voltage 1~ 100 / 115 / 230 V AC ±10% Mains frequency Max. traversing force Traversing speed Spindle length (S 71) Stroke length (SH 71) 50-60 Hz 6,000 N 3-24 mm/s on request on request / standard: 100, 200, 250 and 300 mm Class of protection 1 Type of protection Duty time Control End position limiters Position detection IP00 - IP41 25 s on / 400 s off electrical via HANNING control unit CTRL via HANNING frequency inverter via low-voltage switching system mechanical end position limiter Limit stop via internal micro switch (only SH 71) Hall sensor Force-speed diagram 100 / 115 / 230 V single-phase 50 / 60 Hz kn 8 7 6 5 4 3 2 1 50 Hz 60 Hz 6 10 15 20 7 12 18 24 mm/s 13

Dimension sheets S 71 S 71 x = Free spindle length A, B, C = Cable outlet V = Vertical fork joint H = Horizontal fork joint Option: Fork joint S 71 / SH 71 Zinc-diecasting Aluminium-diecasting Aluminium-diecasting Polyamid Polyamid Option: Travel tube S 71 Option: Spindle nut S 71 14

Dimension sheets SH 71 SH 71 x = Installation length retracted y = Installation length extracted z = Overlap (load and stroke dependent, as of 300 mm stroke length) A, B, C, D = Cable outlet V = Vertical fork joint H = Horizontal fork joint SH 71 with limit switch x = Installation length retracted y = Installation length extracted z = Overlap (load and stroke dependent, as of 300 mm stroke length) A, B, C, D = Cable outlet V = Vertical fork joint H = Horizontal fork joint 15

S 56 / SH 56 linear actuators The Compact The S 56 and SH 56 linear actuators are available as single-phase devices with 230 V. With a winding diameter of 56 mm they are the smallest of our linear actuators. Due to their compact design they can be used for many different applications. The linear actuators of these series are also available as low-voltage three-phase AC system with frequency inverter (DC-FI system). Please ask for our DC-FI brochure. It is however possible to perfectly adapt the windings, spindles and preferred direction of S 56 and SH 56 linear actuators to your individual application. Linear actuator type S 56 Linear actuator type SH 56 Features Powerful single-phase AC motors or low-voltage three-phase drives (DC-FI) Almost constant traversing speed under load variations Compact design thanks to a worm gearbox integrated into the motor end shield Ambient temperatures between -20 C and +50 C possible Individual stroke lengths adapted to the application Individual control options High efficiency plastic gears Mechanical locking device at end positions Approved according to DIN EN 60601, UL 50501, CSA 60601 Optional equipment Micro switch integrated into SH 56 as limit switch Hall IC to detect a position at up to 4500 pulses per minute at rated motor speed (rotor speed acceptance) Customer-specific spindle nuts, travel tubes and receptacles Aluminium travel tube for type SH 56 with individual connection Mirrored spindle and travel tube positions possible Special design with spindle through the fork joint Special design with standing spindle and traversable drive Acme thread spindles with diameters between 12.5 mm and 16 mm, as single and double threaded type Windings adapted to different core widths and defined preferred directions Free-wheeling function 16

Technical data S 56 / SH 56 Mains voltage 1~ 100 / 115 / 230 V AC ±10% Mains frequency Max. traversing force Traversing speed Spindle length (S 56) Stroke length (SH 56) 50-60 Hz 4,000 N 3-24 mm/s on request on request / standard: 100, 200, 250 and 300 mm Class of protection 1 Type of protection Duty time Control End position limiters Position detection IP00 - IP41 25 s on / 400 s off electrical via HANNING control unit CTRL via HANNING frequency inverter via low-voltage switching system mechanical end position limiter Limit stop via internal micro switch (only SH 56) Hall sensor Force-speed diagram 100 / 115 / 230 V single-phase 50 / 60 Hz kn 6 5 4 3 2 1 50 Hz 60 Hz 6 10 15 20 7 12 18 24 mm/s 17

Dimension sheets S 56 S 56 x = Free spindle length A, B, C = Cable outlet V = Vertical fork joint H = Horizontal fork joint Option: Fork joint S 56 / SH 56 Zinc-diecasting Aluminium-diecasting Aluminium-diecasting Polyamid Polyamid Option: Travel tube S 56 Option: Spindle nut S 56 18

Dimension sheets SH 56 SH 56 x = Installation length retracted y = Installation length extracted z = Overlap (load and stroke dependent, as of 300 mm stroke length) A, B, C, D = Cable outlet V = Vertical fork joint H = Horizontal fork joint SH 56 with limit switch x = Installation length retracted y = Installation length extracted z = Overlap (load and stroke dependent, as of 300 mm stroke length) A, B, C, D = Cable outlet V = Vertical fork joint H = Horizontal fork joint 19

The Control unit CTRL The Control unit CTRL HANNING s control unit CTRL without housing is suitable for applications in very small mounting spaces and offers the user many control and safety options. All HANNING linear actuators and lifting columns can be equipped with this type of control unit. Safety options Enable input Motor functions can be enabled or inhibited via this input. Safety switch-off Use this port to connect micro switches which ensure that the motor reverses automatically when touching an obstacle. Both directions of the connected motors can be polled. Error diagnostics Control 5 V DC Connection of up to four analogue keyboards or foot switches Infra-red interface RECS80 for hand or foot switches Coded RECS80 Easy and quick error diagnostics because all important components indicate their operating status by LED. Motor control Connection of up to four motors or three motors and two relay switching outputs. The switching outputs can be used to control any electrical device up to max. 0.5 kw power consumption each. Max. eight freely programmable memory positions which will not be lost in the event of a power failure. Memory positions can be programmed in two different levels so that two different users can enter their individual data. Last position function Auto correction through virtual limit switches. It is possible to connect mechanical limit switches. Two software options are available: Standard and teach software Voltage supply 100 V / 115 V / 230 V AC Control voltage transformer switchable from 115 V to 230 V AC 20

Fax enquiry: +49 (0) 5202 / 707 303 Questionnaire for linear actuators Selected motor type: Company stamp / company address: Voltage / frequency: V Hz Force (pressure / traction): Speed: Stroke length for SH devices: Spindle length for S devices: N mm/s mm mm Duty time: % Special requests: Contact : Telephone: Email: Planned application (if necessary with drawing): Fax: Please Send an offer Send a sample device Give us a call Visit us Send information material about all HANNING products Previous solution: Demand: pieces / year 21

Standard is not enough service Then HANNING is first choice. Our engineering You are not satisfied with standard drives? You are looking for a partner for innovative drive solutions beyond the series? knowledge combined with your requirements result in individual solutions with a special drive. advise check optimi The experience we have gained over more than six decades has made us a reliable partner for our customers. HANNING products can be found in many different branches of industry: drives for mechanical engineering, blowers for food-processing machinery, drain pumps for washing machines and dishwashers as well as linear actuators for versatile applications. HANNING s philosophy is to develop and produce modern and economic drive solutions in close co-operation with our customers. From analysis of the drive problem and finding a custom-built solution to after-sales-service you can rely on us! Interdisciplinary development (motor + electronics + software) Analysis of the drive problem Planning in close co-operation with our customer Application and customer-specific drive solutions, individual mechanical solutions Cost-optimised drive concepts Customer-contact and co-operation over several device generations After-sales-service High manufacturing depth Measuring laboratory, continuous test facilities State-of-the-art electronic manufacturing site (SMD, hybrid technology) Handling and support with national and international approvals and certifications Certification according to DIN EN ISO 9001:2000, DIN EN ISO 14001:2005 Extensive knowledge of different branches of industry 22

& more se measure support 23

HANNING ELEKTRO-WERKE GmbH & Co. KG Holter Straße 90, D-33813 Oerlinghausen Postfach 1361, D-33806 Oerlinghausen Tel +49 (5202) 707-0 Fax +49 (5202) 707-301 info@hanning-hew.com www.hanning-hew.com Printed in Germany Subject to technical alterations S / SH 95, S / SH 80, S / SH 71, S / SH 56/E/10.09/PDF