CS-200 SOLAR PORTABLE TRAFFIC SIGNAL SYSTEM FIELD MANUAL. 134 Ogilvie Avenue, Echuca 3564 (03)

Similar documents
THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Video VBOX Pro RLVD10P2P/RLVD10P2PV/RLVD10P4PV/RLVD20P2PV/RLVD20P4PV. Features

Modular Lube Lubrication Systems System Controls

Luminaire installation box Surface-mounted box Ceiling installation box

FORM EF /96 REV:

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

Service and Technical Support PLEASE CONTACT YOUR NEAREST DISTRIBUTOR If unknown then fax: 44 (0)

SPECIAL SPECIFICATION Video Imaging and Radar Vehicle Detection System

Spring 2011 Microprocessors B Course Project (30% of your course Grade)

User s Guide. Dimensions 4000 Series Control System. Topics at a Glance

15 Series - Dimmer

RADIO RECEIVER RGB CONTROLLING LED STRIP COMMON ANODE

Operations of ewelink APP

SPECIFICATION NO Model 207 Automatic GTAW Welding System

KING-METER USER GUIDE SW-LCD

Video VBOX Lite RLVBVD10LT2. Powerful VBOX data logging and video technology in a user-friendly, affordable product. What can Video VBOX Lite do?

Component Video Matrix Switcher Series ITEM NO.: YS04MA, YS04MD

JAMAR TRAX RD Detector Package Power Requirements Installation Setting Up The Unit

Special Specification 6083 Video Imaging and Radar Vehicle Detection System

Video VBOX Waterproof

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

THE ASTRO LINE SERIES GEMINI 4000 INSTRUCTION MANUAL

User's Manual. CFM/CMM Thermo Anemometer 94204

Sample BD Tech Concepts LLC

Processes for the Intersection

Owners SW-LCD 2.0 Manual & Specifications

MODEL 2018 OPERATION MANUAL Firmware Version

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

VISSIM Tutorial. Starting VISSIM and Opening a File CE 474 8/31/06

Figure 1: Device components

ORDER CODE: EQLED65 USER MANUAL

Sentinel I24 Digital Input and Output Configuration

replacement systems. PT-F200 Series Permanent-Installation Projectors Please make these projectors your very first recommendations as new or

GreenParking. Commissioning guide. GreenParking

LPX Platform LPX Platform

Technical data. General specifications. Indicators/operating means

RADIO RECEIVER RGBW CONTROLLING LED STRIP COMMON ANODE

VBOX 3i Dual Antenna RTK

Sample BD Tech Concepts LLC

CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 2 / SEAV LRS 2150 SET

TRIMBLE GPS / 10MHz REFERENCE MONITOR DISPLAY V January 2015

General FAQs Status as of: 22/10/2018

REMOTE DISPLAY WIRELESS DECODER MK II

Student resource files

Guide to Interpretation of Traffic Signal Timing Reports Produced by the Miami-Dade County (MDC) Advanced Traffic Management System (ATMS)

DCL Time Controller WTDCL. Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group

16-CH Color Full Duplex Multiplexer Instruction Manual

Revision 1.2d

414 P 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS 2. LAY-OUT OF STANDARD SYSTEM INSTALLATION DIMENSIONS. Fig. 1. Fig. A

Mosaic TM Dimmer 3 x 1000 W

NEXT/RADIUS Shelf Mount CCU

SEEP SIGNAL INDICATOR

A.D. Engineering International Pty Ltd - Product Range

Hardware & software Specifications

User interface. Abbreviations / Meanings

CFM/CMM Thermo Anemometer

INSTRUCTION MANUAL. Made in the U.S.A. by USA Dance Floor. Copyright 2017 USA Dance Floor, LLC

Re:connect M 203. RS232 Interface Revox. Dominating Entertainment. Revox of Switzerland. E 2.03

Model KT 115 Cooling incubators with thermoelectric cooling

Start Up or Shut Down Hunting Function. Using the Receiver. If there is a short circuit in the cable, it will display as follows:

2CKA001473B KNX Technical Reference Manual ABB i-bus KNX. KNX LED dimmer Constant voltage 4gang with power adaptor 6155/40-500

Dissolve Control Programming : Projector/Dissolve Control Hook-Up

VHF & UHF REMOTE RECEIVERS INSTALLATION AND PROGRAMMING INSTRUCTIONS MODEL NUMBERS TMP-5414 & TMP 5428

ArteorTM Dimmer 3 x 1000 W / /60

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

TITLE BOX PAGE ONLY. DO NOT MAKE FILM DO NOT PRINT. MATERIAL: White 16lb (60g/m sq), uncoated, prefer recycled stock Ink: Black

Hotel Ballroom. Figure 1 above, graphically details this scenario. 8:1 1 of 5. We ve got it under control

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S

MonitorKey Operation Manual: content/uploads/ MonitorKey Operation Manual.pdf

PRESET 10 ARCHITECTURAL OWNERS MANUAL

Gamma instabus. Technical product information

OWNER'S MANUAL KIT INCLUDES. 3M VHB Mounting Pad Mounting Hardware PART # 40040

UHF REMOTE RECEIVER INSTALLATION & PROGRAMMING

Chapter 23 Dimmer monitoring

THEATRE LIGHTING CONTROL. Strand Lighting

EE 330 Final Design Projects Spring 2015

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

NCM 7216 / 7232 Console OPERATIONS MANUAL

C-net MULTI Operating Instructions MULTI. User s Guide

Model KT 53 Cooling incubators with thermoelectric cooling

VBOX3i Dual Antenna. Measures Slip and Pitch/Roll (RLVB3iSL) Features

VPL-DX221. 2,800 lumens XGA desktop projector. Overview. Features

Series Digital Dimmer. User Manual (VER: 2.0) Net.DO LIGHTING CONTROL EQUIPMENT CO.,LTD

VISSIM TUTORIALS This document includes tutorials that provide help in using VISSIM to accomplish the six tasks listed in the table below.

IS15 Instruments General Manual

C O B A R 18R U s e r G u i d e P a g e 1. User Guide COBRA 18R. Wireless Firing System.

SU17 Series Fiber Optic Sensors

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

2010ECL / 2018ECL / 2018KCL 33X Cabinet Flashing Yellow Arrow Overview

AT004 A10 Multi-Tester, 120 to 277 VAC Test Transceiver

LEON AUDIO. Speaker s Timer. mk3. A versatile timer for use at conferences to indicate the time remaining for a speech.

1.2 General Description

Wind Indicator LED. Contents. Instruction for Use xx.x00, x08, xx.10

CHROMAFLOOD 200 DATASHEET

SAPLING WIRED SYSTEM

Application Note #247 Revision E November 2014

Quick Start Guide. Large-capacity Automatic Pet Feeder

Transcription:

CS-200 SOLAR PORTABLE TRAFFIC SIGNAL SYSTEM FIELD MANUAL

CS-200 FIELD OPERATING INSTRUCTIONS ONE-WAY OPERATION DESCRIPTION OF CS-200 MODES Flash Manual 1 Auto Normal Both Master and Slave flash yellow. Traffic signals are under the control of the Manual Controller. Traffic signals are under the control of Preset Timers. Traffic signals are under the control of Vehicle Detectors but times are limited by the pre-set timers. TWO -WAY OPERATION Manual 2 Manual return This mode of operation is used where traffic is flowing in both directions and ROAD PLANT requires to cross or have access to the carriageway. Both the Master and Slave are normally showing GREEN allowing traffic flow in both directions. When the Master receives a STOP command, both the Master and Slave go to RED. This condition will remain until the Master receives a GO command where upon the Master and Slave go back to GREEN. Manual 3 Auto Return (Not allowed in NSW) This mode of operation is used where traffic is flowing in both directions and ROAD PLANT or other vehicles are leaving a work area and find it difficult to enter a busy carriageway. The CS-200, when in this mode, would have the CABLED MANUAL CONTROLLER or PORTABLE RADIO MANUAL CONTROLLER (Optional) positioned so the driver of the vehicle wishing to enter the carriageway can operate the STOP button. Both the Master and Slave normally show GREEN allowing traffic flow in both directions. When the driver presses the STOP button both the Master and Slave go to RED. After a preset time, set by the Master Red Time, the Master and Slave go back to GREEN. LANTERN INHIBIT OPERATION The CS-200 may be placed into a condition where the system functions normally with the exception that the lanterns remain blacked out. The system must be in FLASH YELLOW before this mode can be selected and will return to FLASH YELLOW when lanterns are enabled again. The main use of this mode is in the setup and testing of the system while the units are positioned on the side of the carriageway.

MODE SELECTION ONE-WAY OPERATION Flash Yellow There are three ways the system can enter this mode: 1. When the Master or Slave is turned on, this mode is automatically selected. 2. If a fault condition is detected. 3. Selected by pressing the FLASH mode button. Manual-1 A small hand-held cabled controller is used to control all manual functions. It is connected to the Master Control panel via a 25 meter 4 core cable. The manual controller has three buttons: - - STOP - MASTER GREEN - SLAVE GREEN Indication of the state of the traffic lights is also provided. This indication will flash if a button is operated while the system is in a MINIMUM TIME period or RED CLEARANCE TIME. This is important due to the fact that the minimum green and red times cannot be overridden and some indication needs to be given to the operator that the system has received the command but is waiting for a minimum time. To select this mode, press the "MANUAL" mode button on the Master unit. The system is now under the control of the manual controller. Pressing the "STOP" button will terminate the running phase, which will go to RED. Both phases will stay on RED until a "MASTER GREEN" or "SLAVE GREEN" button is pressed. (Note that the preset RED TIMES cannot be overridden.) While the Master is green, pressing the "SLAVE GREEN" button will have no effect and vice versa. Auto (Time Mode) This mode is used to control a single lane of traffic where preset timers are used to regulate stop and go times. Times are entered on the keypad and assigned to the appropriate timers. All times are displayed on the LCD and automatically stored in memory when the system is turned off. This alleviates the need to re-enter the times every time the system is turned on. Before entering this mode, RED and GREEN times must be determined and entered into the Master unit. To set, use the keypad at the Master unit to enter the time, and then press the required TIME SETTING key. (eg. Master Red Time) Once the times have been entered, press the "AUTO" mode button. If the system is in "FLASH YELLOW" when the "AUTO" button is pressed then both phases will go to RED and traffic will be controlled in accordance with the preset times. If the system is in "NORMAL" mode when the "AUTO" button is pressed, then the present cycle will be allowed to finish before the "AUTO" mode takes control.

MODE SELECTION Cont d Normal (Vehicle-Actuated) This mode is used to control a single lane of traffic where vehicle detectors are used in conjunction with preset timers. When a moving vehicle is detected a demand is stored, displayed on the LCD and used to control traffic flow. Before entering this mode, RED and GREEN times must be determined and entered into the Master unit. To set, use the keypad at the Master unit to enter the time, and then press the required TIME SETTING key. (eg. Master Red Time) Once the times have been entered, press the "NORMAL" mode button. The system automatically registers an artificial demand for each phase for the first cycle, and then allows the control of traffic in accordance with the detected vehicle flow and the times that have been preset. If the vehicle detector is not connected an alarm will occur and the system will not select this mode. NOTE 1 :- The type of vehicle sensor used will detect movement only. It is therefore possible for a vehicle to be waiting and not have been detected. If this is deemed to be a problem, the sensor can be modified to produce a pulse every 2.5 minutes. Contact supplier for details. NOTE 2 :- Systems are supplied with detectors operating on a frequency of 10.525Ghz which do not require an individual licence. Systems may be supplied (ON REQUEST) with detectors operating on a frequency of 10.587Ghz, but these units will require an individual licence. NOTE 3 :- Check at least once a year that frequencies and licences are still valid.

MODE SELECTION TWO-WAY OPERATION Manual-2 (Manual Return) To enter this mode, put the system into FLASH YELLOW and press the No. 2 key on the keypad twice followed by the MANUAL button. The display will read: - MODE: MANUAL-2 (TWO WAY) The functions of the buttons on the controller are: - STOP Both Master and Slave go to RED. MASTER GREEN Both Master and Slave go to GREEN. SLAVE GREEN Both Master and Slave go to GREEN. Manual-3 (Auto Return) (Not Allowed In NSW) To enter this mode, put the system into FLASH YELLOW and press the No 3 key on the keypad twice followed by the MANUAL button. The display will read: - MODE: MANUAL-3 (TWO WAY) The functions of the buttons on the controller are: - ALL STOP MASTER GREEN SLAVE GREEN Both Master and Slave go to RED No effect No effect LANTERN INHIBIT OPERATION To select or de-select this mode, select FLASH YELLOW and press: - Lanterns OFF - 800 YELLOW TIME Lanterns ON - 801 YELLOW TIME GENERATOR AUDIBLE ALARM INHIBIT To turn the generator audible alarm ON and OFF, press: - Alarm OFF - 700 YELLOW TIME Alarm ON - 701 YELLOW TIME PROGRAMMING THE TRH-3 HAND HELD RADIO REMOTE CONTROLLER The remote has to be programmed by the Master unit before it can control the system. To do this select FLASH YELLOW, hold down the MANUAL/AUTO button on the remote and press: - Program - 600 YELLOW TIME

ENTERING TIMES MASTER RED TIME Time to clear the carriageway before the Slave goes to GREEN. To set - Using the keypad at the master unit enter the time, then press MASTER RED TIME SLAVE RED TIME Time to clear the carriageway before the Master goes to GREEN. To set - Using the keypad at the Master unit enter the time, then press SLAVE RED TIME MASTER GREEN TIME Period of time the Master will remain on GREEN. To set - Using the keypad at the Master unit enter the time, then press MASTER GREEN TIME SLAVE GREEN TIME Period of time the Slave will remain on GREEN. To set - Using the keypad at the Master unit enter the time, then press SLAVE GREEN TIME YELLOW TIME Period of time the yellow aspect on the Master and Slave will remain on when the system is changing between GREEN and RED. To set - Using the keypad at the Master unit enter the time, then press YELLOW TIME

ALARM CONDITIONS SYSTEM ERROR The audible alarm is sounded and the display will have a description of the fault. The audible alarm may be turned off by pressing the CLEAR key. This does not affect the display. RELIABILITY ERROR If 5 errors have been detected in a 20 minute period, then this alarm will be displayed. FATAL ERROR If the main electronic system stops or it has detected that two aspects are on at the same time, then this condition will be invoked. This alarm is indicated by flashing all the status lamps on the front panel. (The display may or may not indicate this error).

ENVIRONMENTAL REQUIREMENTS WIND LOADING MAX. WIND VELOCITY WITHOUT ANCHOR BLOCKS 95Km/Hr Requirements for Wind Velocities above 95Km/Hr. 1. Remove wheels. 2. Attach 735Kg to each trailer to prevent high winds above 95Km/Hr. from shifting its position. Procedure:- a) Remove wheels. b) Place ballast tray under towbar and attach it to the trailer using the steel pin and Padlock provided. c) Fill tray with 6 cubic feet of earth or crushed rock. d) Place ballast tray under each trailer axle spring and attach it to the trailer using the chain provided. e) Fill each tray with 6 cubic feet or earth or crushed rock.

ENVIRONMENTAL REQUIREMENTS

QUICK REFERENCE GUIDE MAXIMUM DISTANCE BETWEEN UNITS 1Km MAXIMUM VISUAL RANGE OF LANTERNS 100m ENVIRONMENTAL REQUIREMENTS (Wind Loading) Quick Reference Guide Clear System Log System Log System Time System S/N Channel Selection CH1 Channel Selection CH2 Lamps OFF Lamps ON Generator alarm OFF Generator alarm ON 999 YELLOW TIME 900 YELLOW TIME 901 YELLOW TIME 902 YELLOW TIME 614 YELLOW TIME 647 YELLOW TIME 614 YELLOW TIME 648 YELLOW TIME 800 YELLOW TIME 801 YELLOW TIME 700 YELLOW TIME 701 YELLOW TIME Program Manual Remote 600 YELLOW TIME (While holding down the RETURN button on the Remote). To clear the Audible Alarm of any error press the CLEAR BUTTON

RELATIONSHIP BETWEEN ALL-RED CLEARANCE TIME AND TRAVEL DISTANCE FOR A RANGE OF VEHICLE SPEEDS 100 10 km/h 20 km/h 30 km/h 90 40 km/h 80 70 50 km/h 60 60 km/h 50 40 30 20 10 0 0 100 200 300 400 500 600 700 800 900 1000 TRAVEL DISTANCE (metres)