Tech Specs and General Terms & Conditions 2018

Similar documents
Tech Specs and General Terms & Conditions 2018

STANDARD TIME SCHEDULE JUPILER STAGE doors + showtime HET PARADIJS: 20:30 // 21:00h 14:00 Start local tech crew & backstage manager

Tech Specs and General Terms & Conditions 2018

A38 SHIP CONCERT HALL TECHNICAL RIDER 2018!

La Gravière/ Chemin de la Gravière 9, 1227 Genève. Technical Rider. Updated 21/10/15

Les Docks / Av. de Sévelin Lausanne. Technical Rider

v. 2.4 Address: Musikhuset Posten Østre Stationsvej 35 DK-5000 Odense C Booking/management: Morten Østlund

VENUE SPECS Channel Music GmbH. 2 Floor Plan. Falckensteinstr Black Room Berlin. 8 Blue Room. 12 Venue Info

Les Docks / Av. de Sévelin Lausanne. Technical Rider. Technical Rider Docks, updated

de oosterpoort groningen main hall

Main Hall. Left side of the building. Ramp available. *elevator available (1,4m x 3,3m)

TECHNICAL SPECS SECOND HALL PATRONAAT

Tickets will be sold through our ABC account and all tickets are scannable on entry.

TECHNICAL SPECIFICATION

mainstage or theatercafe, on demand on demand 103 dba at FOH 6x4x1 meter (if needed bigger) + stairs Max. 4x drumriser (2x1x0,5 meter) No Yes

PRODUCTION BIBLE. last update November 2015

THE CLASSIC GRAND 18 JAMAICA STREET GLASGOW G1 4QD

YAAM Berlin Venue Specifications & Technical Rider. Effective April 2018 Availability, errors and specifications subject to change without notice!

technical rider version August 2015 People s Place Stadhouderskade ES Amsterdam

MAIN STAGE GENERAL INFO AND FACILITIES

Analog General Information West End Ave. Nashville, TN, Time Zone: CST

Small Hall. Left side of the building. Ramp available. *elevator available (1,4m x 3,3m)

TECHNICAL SPECS MAIN HALL PATRONAAT

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

CONTENTS. CONTACT DETAILS. FINDING US. VENUE INFORMATION. TECHNICAL INFORMATION. ROOM DIAGRAMS.

Barbican Concert Hall Sound System Spec

Ed Blackwell Production Manager Mike Weller Head of Music

IDEAL BAR. General information Technical specifications Production information

Contents. 1. Contacts. 2. Directions & Transport Links 2.1. Address 2.2. Local Map & Directions 2.3. Public Transport

Theater De Meervaart Amsterdam Red Hall (Rode Zaal) and Blue Hall (Blauwe zaal)

FASO DANCE COMPANY KALAKUTA REPUBLIK

Pioneer set monitor 1 1x DJM 900 nexus 2x CDJ 2000 nexus 2x QSC K12 monitor speaker

SOUND TECH RIDER FIDO

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

SHOWBOX SODO TECHNICAL SPECIFICATIONS

GENERAL INFORMATION CONTACT DETAILS. Venue Booker: Shaun Adams E: P: (03)

ISLAND HALL TECHNICAL INFORMATION

Production Advance Information

TECHNICAL SPECIFICATIONS

LOAD IN / LOAD OUT CARS / SPLITTER VAN / NIGHTLINER THROUGH MAIN ENTRANCE SITUATED AT AUGUSTE ORTSSTRAAT 20-28, 1000 BRUSSEL.

Treefort Music Fest- March Festival Information Main Stage

The Lexington VENUE SPEC. The Lexington Live music venue and whisky lounge. Version 2.5 Updated January 2015

Section A: Front of House (FOH) Public Address (PA) Speaker System

TECHNICAL REQUIREMENTS

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Information for Incoming Companies

GENERAL INFO. GENERAL ADMISSION: 1427 TOTAL 1058 main floor, 90 mezzanine, 279 balcony. SEATED: 1145 TOTAL 776 main floor, 90 mezzanine, 279 balcony

Contact. Directions. Stichting Studio301 Overtoom HW Amsterdam The Netherlands.

National Folk Festival PA Specs 2018 MARQUEE

DEREHAM MEMORIAL HALL

RIDER 2018 version 1 English

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

WE RE BACK CONCERT PACK UNSWROUNDHOUSE.COM

Project manager (PM): Pamela Næss Mail: Phone:

SHOWBOX AT THE MARKET TECHNICAL SPECIFICATIONS

Event Hire Equipment Packages

Technical Specifications for the Rival Theatre 2018

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

The Lantern Technical Information

SHUBERT THEATER 247 College Street, New Haven, CT

Techinal Specifikations

TECHNICAL SPECIFICATIONS Big Venue & Club

TECHNICAL / HOSPITALITY RIDER

Technical Specifications

ROSE THEATRE MAIN THEATRE

Technical Specification Pavilion Dance

UNIVERSITY CONCERT HALL. Technical Specification

Theatre Technical Specification

The Willoughby Brothers

Technical Services and Specification

BUFORD COMMUNITY CENTER, TOWN PARK & THEATRE THEATRE AND STAGE RENTAL AGREEMENT

Sandusky State Theatre Technical Specifications

Monty Kultuurfaktorij Technical Rider

Technical Specifications

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Irish Heartbeat TECHNICAL RIDER. Video Projection Requested

Visy Theatre technical information and general specifications 2019

CARGO PRODUCTION GUIDE 2016

Rider Part1: Technical Requirements, A Cappella Show

Ex-Hire Used Equipment Price List

Technical Specification for the Alley Theatre, Strabane

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Project manager (PM): Pamela Næss Mail: Phone:

Lancaster Performing Arts Center RENTAL FEES and Policies

Technical Information

Patriots Theater at the War Memorial Technical Data

Rhodes Arts Complex Bishops Stortford. Technical Specifications

MAYHEM POETS CONTRACT RIDER

Main House Technical Specification

Production Manager Shawn Dealey

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Production Manager Shawn Dealey

Technical Specifications

Technical Specification Ardhowen Theatre

Technical requirements & conditions for hirers

Music Hall of Williamsburg

Producer of Event: Person Signing Agreement: Title: Nonprofit Corporation (Tax ID: ) FLC Department FLC Student Organization Other (Tax ID: )

Contact Julianastraat 46, 4301 NC, Zierikzee (NL) +31 (0) (Monday-Friday 13:00-17:00h)

Setup & Formats. There are 8 sections of 8ft x 4ft Litedeck with 1ft, 2ft and 3ft stage legs to build various forms of staging, podiums and risers.

Transcription:

Tech Specs and General Terms & Conditions 2018 GENERAL INFO Venue Metropool, LOCATION: ENSCHEDE Address Willem Wilminkplein 2 7511 PG Enschede Netherlands Phone +31 (0)74 243 80 00 Website www.metropool.nl METROPOOL CONTACT Promotor & Marketing Guido de Jongh guido@metropool.nl +31(0)74 243 80 00 (Monday-Thursday 9-17h) Sound / Light Twan Schipper twan@metropool.nl +31(0)74 243 80 00 (Monday/Tuesday 9-14h) Production & Facility Michiel Toenink michiel@metropool.nl +31(0)74 243 80 00 (Monday-Friday 9-17h) *not available on Wednesdays Advancing / Preproduction Domenique Gerrits-Verbeek domenique@metropool.nl +31(0)74 243 80 00 (Tuesday-Friday 9-15h) STANDARD TIME SCHEDULE GROLSCH ZAAL doors + showtime SAXION ZAAL: 20:30 // 21:00h 14:00 Start local tech crew & backstage manager 15:00 Get in / load in 16:00 18:00 Soundcheck 17:30 Get in / load in support 18:00 18:30 Diner 18:30 19:00 Soundcheck support 19:30 Doors 20:30 21:00 Support (30 minutes) 21:00 21:20 Changeover 21:20 23:00 Headliner (aprox. 90 150 minutes) Curfew dressing room (60 min's after show) 0:00 Curfew (always negotiable!)

IMPORTANT NOTES Guest list Time schedule Backline Dinner Prohibited Smoking Recordings Merchandise The guest list has to be mailed to sylvia@metropool.nl one week prior to your show. For the big hall called Grolsch Zaal each production has a max of 15 persons. Headliner has first choice for the number of guests, the support can fill up the empty places. For the small hall called Saxion Zaal each bandmember of the headliner can have one guest. Opening acts cannot have guests, due to our limited capacity. Please respect our timetable, which we will send shortly after, along with the ITINERARY. Please read and confirm. Early get in is possible, costs are 100,- per hour extra; cash payment on arrival. No changes can be made one week prior to show. Due to legal aspects concerning working hours, ticket information and employee costs, agreed timetables are not to be exceeded. Metropool does not provide a standard backline (except if agreed on in booking agreement, then we will rent one). Note: Because of the small format of the Saxion Zaal, we advise bands to play on ONE drumkit. Simply because there is no space for 2 drumkits and changing sets takes a lot of time. We will ask you to share the hardware of the kit. Therefore please get in touch with the other band(s). Dinner will be in-house. Since we have no kitchen available, we order take out. Or we provide a buy out. Your advancing contact will advise on the possibilities. Vegetarians or vegans will be served according the catering rider of the artist. Use of pyrotechnics only allowed with Dutch license which has to be agreed on by Twan Schipper, two months prior to the show. We CAN provide a Dutch license, please contact us 2 months prior to the show (costs: 500,- excl. taxes). Use of confetti / silly strings and such only allowed when agreed upon (cleaning costs: 250,- excl. taxes). Please note that by the 1 st of July 2008 it is no longer permitted to smoke in clubs/pubs/restaurants and venues in the Netherlands. Our fire alarm will be activated in case of smoke, which results in complete evacuation and the show will be canceled. When artist and/or artist's crew smokes in our building and causes the fire alarm to go off, the artist will not receive payment/fee. Recordings of the show can be made on separate tracks. We provide all tracks on 24 Bit / 48 Khz wave format. Artist has to bring an own portable harddisk with USB 2.0 connection. Costs: 75,- (excl. taxes) to be paid in cash to the backstage manager. For mixing options, contact Michiel Toenink; In case you bring a merchandiser please let him/her ask the backstage manager for the best merchandise spot and load in / load out; If you want us to take care of your merchandise, please contact us 1 month in advance of the show. We ask for 10% of the total turnover OR 5 shirts;

Settlement Local crew Security Parking Internet / Wifi Hall expenses is a fixed expense and includes: standard house pa & lights, standard promotion, standard tech crew (incl. 2 stagehands), NOT INCLUDED in Hall expenses: Barrier, Ground transportation, Runner, Backline, IEM systems, Technical requirements other than mentioned in our tech specs. Performing non-dutch artists will be exempted from Dutch artist tax if they are able to prove that they are a resident of one of the 82 treaty countries with which the Netherlands has concluded a tax treaty. For non-dutch artists from countries without a tax treaty, guarantee is liable to 20% tax. Dutch artists have to apply the regular Dutch income-tax rules. However for these last two groups 163,- per artist is free of tax for expenses. Also they can make use of more tax free expenses using the KVB Tax Exemption. For all of the above: in order to make payments to the artist Metropool needs a copy of the passport of all performing artists. NO COPIES = NO PAYMENT. We use a payment term of 30 days. 1x FOH engineer 1x Monitor engineer 1x Light engineer 2x Stagehand Extra stagehands are 22.50 (excl. taxes) per hand per hour extra Everybody helps loading in and out, short push Standard security / NO BARRIER Parking space for one truck or tour bus/nightliner per hall. Parking space available from load in time. (not earlier!) Parking space available till 1,5 hours after the end of the show! (overnight parking possible ONLY ON REQUEST) Tour bus/nightliner power connection: 16A Shuco 16A CEE Red 16A CEE Blue 32A CEE Red We have a secured wireless internet connection in our dressing rooms. Backstage wifi: open network, no password needed

ROUTE DESCRIPTION Directions from highway A1/A30/E30; Amsterdam, Amersfoort, Hannover, Berlin DO NOTE! USE THIS ADDRESS FOR NAVIGATING TO THE VENUE Parallelweg 82 7511 PA Enschede 1. A1 / Amersfoort Take the A1 to the Westerval / N18 in Enschede. Take the A35 exit 2.. Drive to the southeast on the A1 3. Follow the 2 right lanes at the junction Azelo to follow the signs E30 / A35 / A1 direction Enschede / Hengelo / Osnabrück 4. Follow the 2 right-hand lanes at the junction Buren to follow the signs A35 towards Münster / Enschede / Hengelo-Zuid 5. Continue onto the A35 6. Follow the 2 right-hand lanes to take the exit towards the Westerval / N18 7. Continue on the Westerval / N18. Take the Parkweg to the Parallelweg in Binnensingelgebied 8. Follow a lane of your choice to turn right to the Westerval / N18 9. Turn left onto the Parkweg (signs for Rigtersbleek) 10. Turn right to stay on Parkweg 11. Turn left to stay on Parkweg 12. Turn left onto De Ruyterlaan / Prinsessetunnel Continue on De Ruyterlaan 13. Turn right onto Hengelosestraat 14. Continue onto Molenstraat 15. Turn right onto the Wenninkgaarde 16. Turn left onto the Parallelweg

Enschede Tech specs Grolsch Zaal Max sound level: 103 DBA over 15 minutes, DUTCH COVENANT, RESPECT THIS, THANK YOU Capacity: 500 / 800 Stage size: Clearance: Powersupply: Risers: 14 x 6 meters, sidestage; 2 meters, height; 1,10 meters 6,5 meter (on stage) 1 x 63 A CEE-form, SOUND S.R. 1 x 63 A CEE-form, LIGHT S.L. Excluding power supply house sound&light (CEE-form is 3 fase+neutral+earth) Backline power 220V, 220 to 110 volts convertors available 10 x Stagedex 2 x 1 meter decks standard. 40cm (with and without castors), 60cm, 80cm en 100cm legs. HOUSE PA SPECS PA; each side: Processing: Multicore: FOH Desk: 4 x Meyersound MSL4 (main) 1 x Meyersound CQ1 (balcony) 3 x Meyersound 700-HP (sub) Yamaha DME24N Media Numerics Rocknet Digital Multicable LK37 subsnake (12 in/outs) Yamaha PM5Dv2 48 channels Effects: Lexicon PCM 91 TC Electronics D-2 Player: Tascam CD-01 cd/mp3 player Monitors Monitor desk: Wedges: Amps/processing: Sidefills (on request): Drumfills: Yamaha M7CL48 12x APG SMX15 15 + 1,4 coaxial (max 8 groups) XTA DP448 processing 8x Crest CA12 + 8x Crest CA2 2 x Meyersound CQ-1 top + 2x 600-HP sub 1 x Meyersound CQ-2 top + 1x 600-HP sub

Microphones: DI s: DJ-set (both stages): Shure, Sennheiser, AKG, neumann etc. Radial & BSS 1x Pioneer DJM-900NXS 1x Pioneer DJM-800 1x Allen & Heath Xone92 3x Pioneer CDJ-2000NXS 4x Pioneer CDJ-2000 8x Technics SL1200 LIGHTS Truss/rigging Above stage: Above audience: 2 x 12 meter truss (max 1000kg per truss) 15x flybar (150kg each) 1x 12 meter front truss (max 1000kg) 4 x 3 meter hall truss (max 1000kg per truss) All hoists are D8+, 8 meters/minute 1x ALP-lift hoogwerker Desk: Dimming: Moving heads/effects: GrandMA 2 Light Avolites Pearl 2008 (on demand!) 84 channels Compulite CompuPack; 2,5 KW each 6 channels Compulite CompuPack; 5KW each 36 channels MA touring dimmers; 2,3KW each 12 x Robe 250 AT Spot (above stage) 6 x Robe 250 AT Wash (above stage) 2 x Robe 575 AT Spot (above audience) 4 x Hungaruflash 5KW strobe 2 x Look Unique hazer 1 x Look Viper smoke Conventional: 16 x PAR 64 sixbar 1kw 6 x PAR 64 floorspot 1kw 4 x PAR 64 ACL bar 4 x 4-lite stageblinder 6x Fresnel 1kw

Saxion Zaal Max sound level: exceeded. 103 DBA over 15 minutes, limiters will be inserted on outputs if this limit is Max sound level: 103 DBA over 15 minutes, DUTCH COVENANT, RESPECT THIS, THANK YOU Capacity: 300 Stage size: Clearance: Powersupply: Risers: 10 x 3 meters, height; 0,8 meters Expandable to 10 x 4 meter with stagedex. 7,40m (on stage) 1x 63 A CEE-form, stage left, LIGHTS Excluding power supply house sound&light (CEE-form is 3 fase+neutral+earth) 4x stagedex 2x1m, 40cm legs with and without casters. HOUSE PA SPECS PA; each side: Amps / processing: Multicore: FOH Desk: Effects: Player: Monitor desk: Wedges: Amps/processing: Microphones: DI s: DJ-set (both stages): 2 x Meyersound CQ-1 (main) 1 x Meyersound CQ-1 (balconyfill) 2 x Meyersound 700-HP (sub) Yamaha DME24N Media Numerics Rocknet Digital Multicable LK37 subsnake (12 in/out) Yamaha M7CL48 TC electronics M3000 TC electronics D-2 Tascam CD player Yamaha M7CL48 8 x APG SMX15 15 + 1,4 coaxial XTA DP448 processing 8x Crest CA12 + 8x Crest CA2 Shure, Sennheiser, AKG, Neumann etc. BSS + Radial 1x Pioneer DJM-900NXS 1x Pioneer DJM-800 1x Allen & Heath Xone92 3x Pioneer CDJ-2000NXS 4x Pioneer CDJ-2000 8x Technics SL1200

LIGHTS Truss/rigging Above stage: 2 x 8 meter truss Above audience: truss in triangle shape, 3x 8m truss. All hoists are D8+, 8 meters/minute ALP-lift hoogwerker Desk: Dimming: Moving heads/effects: MA lighting DOT2 Avolites Pearl 2008 (on demand!) 48 channels Complite CompuPack; 2,5 KW each 6 channels Compulite CompuPack; 5 KW each 8 x Robe 575 AT spot 4 x Robe 250 AT wash 3x Hugaruflash 5KW strobe 1 x Look Unique Hazer 6 x LED Sphere (above audience) Conventional: 8 x PAR 64 sixbar 1kw 6 x PAR 54 floorspot 1kw 2 x 4-lite stageblinder 6 x ADB 1kw fresnell

Muziekcafé Enschede Max sound level: exceeded. 103 DBA over 15 minutes, limiters will be inserted on outputs if this limit is Max sound level: 103 DBA over 15 minutes, DUTCH COVENANT, RESPECT THIS, THANK YOU Capacity: 150 Stage size: Clearance: Powersupply: Risers: 5 x 3 meters, height; 0,6 meters 4 meter (on stage) 1x 16A CEE-form red, stage right, AUDIO No risers available for this stage HOUSE PA SPECS PA; each side: Amps / processing: Multicore: FOH Desk: Wedges: Amps/processing: Microphones: DI s: DJ-set (both stages): 1x Martin Audio W8C top 2x Martin Audio W8CS sub XTA DP448 processing Crest amps Behringer SD16 digital snake (16 in, 8 out) Behringer X32 compact (16 local inputs, 8 local outputs)œ 2 x GAE PS121M (12 inch, 1 inch) XTA DP448 processing 8x Crest CA12 + 8x Crest CA2 On demand On demand On demand