Medium Box for Cable Termination

Similar documents
FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

FIST-GCO2 GCO2-BC8 GCO2-BD8 GCO2-BE8 GCO2-BF8. 5 Heatshrink installation. 1 Introduction. Content. 6 Fiber routing. 2 General. 7 Fiber routing on tray

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

Ordering Guide. for FIST-GSS2 product range

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

Ordering Guide of the Generic Closure Organizer (FIST-GCO2)

FOSC 450 C6 and D6 Closures

Ordering Guide of the Fiber-Optic Splice Closure (FOSC-400)

GCO2-BC6/16-XX GCO2-BD6/16-XX GCO2-BE6/16-XX

3M Distribution Box (DDB)

Installation Instructions

HCS - HES Cabling Systems

3A TC 699/SIP/UK/12

GCO2-BC6/16-MC-XV GCO2-BD6/16-MC-XV GCO2-BE6/16-MC-XV. 3.1 Installation of the workstand 3.2 Opening the FIST-GCO2

Ordering Guide. for FIST-GCO2 product range

Optical Distribution Box 300 Installation Guide. Version : R0.0

FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N

Ordering Guide of the Generic Closure Organizer (FIST-GCO2)

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

Gel-sealed in-line fiber optic closure

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

FACT Cable Termination Unit

3M Fiber Optic Wall Mount Enclosure 8430 Series

18mm ECAM Cable Entry Port

SLiC Fiber Aerial Closure System

IP-LINX. Installation Guide

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

IP-LINX Fiber :: X-XXXX

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

3M Coupling Tray FDTC-10S-COUPLINGTRAY

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

2178-L/S Series Fiber Optic Splice Case with Gasket

3 SLiC Aerial Closure with Rubber End Seal

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

3M Better Buried Closures

27mm ECAM Double Cable Entry Port

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

Seal Kits for BUDI Enclosures

3M Fiber Closures BPEO

RAIL D-SUB BACKSHELLS

Instructions. Cable with Armor F CAUTION. October Rev A

3M Better Buried Compound Compression Closure System

INSTALLATION INSTRUCTIONS

FOSC-450 Product Range Ordering Guide

Fiber Optic Splice Closure GPJ Instruction Manual

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

3M Cold Shrink Foldback Splice Jacket Kit

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

FOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15

Instruction manual. Midi Fiber Dome. Instruction manual

LANsense Modular Patch Panel for 24 Snap-in Connectors 1 HU. empty. Clip-on. with Sliding mechanism. Black or white INSTALLATION GUIDE

FOSC 400 B2/B4. Fiber Optic Splice Closures. Table of Contents. Page 1

Clearview. Classic Cassettes. Installation Manual. Clearview Classic (HD) High Density. Part #: Rev: A Updated:

Quante BPEO Splice-Protection Closure for Optical Fiber Cables. Features Advantages Benefits

3M Cold Shrink Splice Kit QS-III 5515A

FOSC 400 A4 Fiber Optic Splice Closure

WCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12)

Instruction Guide February 2017

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

3M Cold Shrink Splice Kit QS-III 5416A

Installation instructions Roxtec CF 16 EMC and Roxtec CF 16 O EMC

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

LGX Compatible (LSX) Connector Module) User Manual)

3M Cold Shrink Splice Kit QS-III 5514A

Installation instructions Roxtec RM ES B

4320 SS-25 Self-Strip Terminating Block

Crimp & Cleave Termination Instructions for SEL ST Connectors

Installation instructions Cable transit device Roxtec RS ES Ex

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions

Installation instructions Roxtec RM PE B

Modular Six pack Patch Panel. for 24 Snap-in Connectors. Clip-on and Shutters. with Sliding mechanism INSTALLATION GUIDE

Next Generation Frame (NGF) Fiber Combination Block (FCB) User Manual)

Panduit Recommended Best Case Practice Split Fibre

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)

DREAMOC DIAMOND 4K - ASSEMBLY GUIDE VERSION ORIGINAL ASSEMBLY GUIDE

INSTALLATION INSTRUCTIONS

SLiC Fiber Aerial Closure 533 and 733

Fiber Optic Splice Closure GPJ Instruction Manual. [Escribir texto]

Assembly Instructions

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

Crimplok. Connectors. 3M Crimplok ST* Connector Multimode 1. 3M Crimplok SC Connector Single-mode 2

3M Locator Plate N

2178 L/S Series Fiber Optic Splice Cases and Accessories

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

LANmark-OF ENSPACE Patch Panel

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

Sections 1. Application Equipment 2. Cable Preparation 3. Assembly 4. Termination Procedure 5. Inspection 6. Repair 7.

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

3M No Polish Jacketed SC/APC Connector

Coyote popup display set up instructions

Furcation of a Central Tube Ribbon, Gel-Free, Non-Armored, 96- to 192-Fiber Cable into an OSE-UD

Transcription:

FIST-MB2-T I N S T A L L A T I O N I N S T R U C T I O N Medium Box for Cable Termination Contents 1 Introduction 1.1 Product description. 2 General 2.1 Tools 2.2 Kit contents 3 Installation and pre assembling of box 3.1 Preparation of box 3.2 Opening of the ports. 3.3 Installation of wrap around groove plates 3.4 Installation of the splicing trays 3.5 Mounting of the box on the wall 4 Cable installation 5 Pigtail installation 5.1 Installation pigtails with connectors 5.2 Installation of pigtails with Kevlar termination 5.3 Pigtail routing to the splicing trays 5.4 installation of the pigtail seals 6 Fiber organisation after splicing 7 Closing the box 8 Important steps 9 Rearrangements 4.1 Cable preparation 4.2 Cable termination 4.3 Routing of the cable fibers 1 Introduction 1.1 Product Description The FIST-MB2-T is a Generic Box for a fiber management system that offers the function of splicing and patching. It provides a mechanical and environmental protection for all the fiber optic components and permits easy access by both the network provider and the customer. The box is applicable indoor and inside street cabinets. The FIST-MB2-t box is designed to terminate, and patch fibers, it can handle up to 16 connectors. 2 General 2.1 Tools Hammer Screwdriver Marker Fiber guiding pin FACC-tube-cutter-01 FIST-GB-CUT-TOOL-PG16 FACC-TUBE-Stripper-02 FACC-HEAT-GUN-220V or 110V 1460W hot air gun to cut loose tubes to cut holes for glands to strip loose tubes to install the heatshrink cable seals

2.2 Kit contents 3 Installation 3.1 Preparation of box 3.1.1 Unlock the screws and remove the cover. Depending on the network layout and the construction of the used cables, the kit content may be different. Some of the components will be pre-assembled in the box depending on the selection and the ordering. The minimum content will be: 4 pcs of mounting bolts and plugs for wall mounting. The box base Pre installed - Universal Mounting System profile. - Small fiber routing block with tube holders - Tray lid and guiding pin and retainers - Velcro strap - FAS cap including the tray wedge - Cable strain relief connectors and fixing plate - patch panel with 2 anti movements strips (AMS) Cable glands, including pigtail seals (4 pigtails per seal) Tiewraps The Cover (including 4 preinstalled screws). Installation instruction 2.3 Selection table MB-2-T box capacity W/A groove Type of tray max.number Capacity plate units of trays connectors KTUs 8 FIST-SOSA2-8SC-X 8 16 8 8 FIST-SOSA2-8SE-X 4 16 8 8 FIST-GB2-FOR04-XX-2 4 16 n/a 6 FIST-GB2-FOR08-XX-2 2 16 n/a 4 FIST-GB2-FOR12-XX-2 1 12 n/a 3.1.2 In case of a box with lock, lift cover and remove the guiding pins. 2

3.2 Opening of the cable ports 5 4 3 2 1 3.2.2 Select the appropriate gland depending on the cable diameter. 3.2.3 Install the glands in the selected ports by tighten the nut on the inside of the box, do not forget to install the rubber ring on the outside of the box. 3.2.1 Drill or knock out the ports to be used, (cable in, port 1 - pigtails out, ports 2, 3, 4, 5). 3

3.3 Installation of wraparound groove plates 3.5 Mounting of the box on the wall 3.3.1. Take the groove plates and slide the long protrusions into the left bracket of the UMS bracket. 3.5.1. Place the template against the wall and mark the selected mounting positions onto the wall. 3.5.2. Drill the holes (diameter. 6 mm, depth 60 mm) and place the plugs into the holes. 3.3.2. Pull on the long snapfit towards the profile till it clicks in the UMS bracket, start on the FAS block without leaving gaps between the plates. 3.4 Installation of the trays 3.4.1 Install the splicing tray by pushing the lip on the groove plate slightly up with the tray and move the tray lateral from left to right into the hinging cavity. Note. 1 for single element start on the second position leaving one position open between each of the trays. 2 For ribbon 4-8 trays the tray hinges have to be inserted from right to left. 3.5.3. Hold the base part onto the wall. Insert the screws and tighten. 4

4 Cable installation For slotted core cable only 4.1 Cable preparation 4.1.1. Feed the cable through the cable port gland. 4.1.3.1 Install a protection tube of 150 mm over the fibers of each slot and slide it into the slot of the cable. 4.1.2. In case the cable diameter does not match with the diameter of the gland seal, remove the plastic nut, metal ring and rubber seal inside the gland and peel out some of the break out rubber rings up to the right diameter. 1800 mm 4.1.3.2 Protect the transition from the cable to the tubes with a few layers of Teflon tape. 60 mm 4.1.3.3 Consider the protection tubes now as loose tubes in the installation. 4.1.3 Prepare the cable according to the drawing, Strip and clean the cable over a length of 1800 mm. and cut the strength member at 60 mm length. 5

4.2 Cable termination 4.2.3 Secure the cable with a tiewrap onto the cable attachment plate. 4.2.1 Pull the cable back in the correct position, the cable jacket should protrude 30 mm into the box. passing the cable strapping point. 4.2.4 Tighten the gland 4.3 Routing of cable fibers 4.3.1 Allocation of the tubes in the tube holders. Important; loose tubes should be routed up to the tube holder in such way that access to all the tubes is possible at all times in case of rerouting without crossings of already installed tubes. 4.3.2 Open the Velcro strap and remove the FAS block cap. 4.2.2 Insert the strength member in the strength member connector and tighten the connector with a screwdriver. If necessary remove the plastic core from the straight member till it fits in the strain relief connector. 6

4.3.3 Mark the tubes between the two marks on the tube holder. 4.3.5 Position the loose tubes in the tube holder and slide the tube holder retainer with the snap forwards in the lowest possible cavity of the tube holder above the loose tube(s). The tube holder retainer must snap. 4.3.3 Cut and remove the excess of the loose tube and clean the fibers. 4.3.6 Route the fibers in the grooves of the wraparound groove plate to the entrance of the identified tray. Fiber must be routed in the groove of the tray hinge. 7

4.3.7 Pull gently on the fibers in the tray and make sure that the fibers are well contained in FAS block and wraparound groove plate. 5.1.2 When all adapters are installed slide them to the left side of the patch panel, measure the length of the Anti Movement Strip and cut the AMS to length (distance of the opening minus 6 slots). 4.3.8 Store the fibers temporarily on a tray. 5 Pigtail installation 5.1.3 Install the anti movement strip (AMS) on both the slot sides of the patch panel. 5.1 Installation of pigtails with connectors 5.1.1 Connector adapters have to be installed in the patch panel. Push the adapter from the top in the patch panel and slide it in position. 5.1.4 Mount the pigtail connectors in the adapters and route the pigtails to the splicing trays. 10

5.2.3 Pull the pigtails for 2000 mm through the patch panel and mark them. 5.1.5 Remove the pigtail gland seal and nut, feed the jumper connectors through the gland and mount the connectors to the adapter on the patch panel. 5.2 Installation of pigtails with Kevlar termination unit (KTU) 5.2.4 Remove the pigtail jacket up to the mark. Cut away the Kevlar up to 50mm-100mm from the ring cut. 5.2.1 A Kevlar termination adapter has to be installed in the patch panel. Push the adapter from the top in the patch panel, an slide it in position. Each adapter can contain two KTUs. 5.2.5 Mount the two pieces of the KTU together by sliding the inner part in the outer part. 5.2.2 Slide the pigtail gland nut over the pigtails and feed the pigtails through The gland and the patch panel adapter. 5.2.6 Take the two pigtails and bend the Kevlar over the inner part lips back between the two parts of the KTU. Mark the pigtails 50 mm away from the connector. 11

5.2.7 Close the KTU connector by snapping the lid, and pull on the Kevlar to slide the inner part backwards as far as possible. 5.3.2 Store the pigtails temporary on the tray. 5.4 Installation of pigtail gland seals 5.2.8 Cut the Kevlar yarns at the connector and install in the patch panel adapter. 5.4.1 Insert the pigtails or jumpers in the rubber wrap around seal of the pigtail seal. 5.3 Pigtail routing to splicing trays 5.3.1 Guide the fibers to the cassette through the groove under the tray hinge. 5.4.2 Position the rubber pigtail seal in the gland, avoid pigtail crossings in the gland. 12

7 Closing the box 5.4.3 Tighten the gland nut on the pigtail seal. 6 Fiber organisation on trays after splicing 7.1 Install the FAS block cap and the retainer. 6.1 Take the splice protector and put it centered towards the splice holder. 6.2 Different types of splice holders can be fitted in the tray with the use of an adapted splice holder. 7.2 Secure the splicing trays with the Velcro strap. 13

7.5 In case of a box with lock insert first the four guiding pins in the box before installing the cover. 8 Important steps during installations 7.3 In case of a inner cover hook the cover over the brackets and secure with the key. Make sure that grooves on FAS and wraparound groove plate are clean. Clean the fibers Tubes routed up to the tube holder should be routed in such a way that complete access to the tubes is possible without creating crossings and without creating distortions on the tubes already installed in the tube holder. Use correct lengths in the tube holder. Make sure not to loose ID 9 Rearrangement Avoid to pull fibers in-between groove plates Avoid fiber movement between tube holder and first containment lip on the FAS block. If accidentally active fibers are removed from the containment devices, reposition them carefully. 7.4 Place the cover on the box base and secure the cover with the screws. 14

15

Tyco Electronics Raychem NV Diestsesteenweg 692 B-3010 Kessel-Lo, Belgium Tel.: 32-16-351 011 Fax: 32-16-351 697 www.tycoelectronics.com www.telecomosp.com Tyco Electronics, TE logo and FIST are trademarks. Kevlar and Teflon are trademarks of E.I. du Pont de Nemours. Velcro is a trademark of Velcro Industries B.V. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, Tyco Electronics makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. Tyco Electronics obligations shall only be as set forth in Tyco Electronics Standard Terms and Conditions of Sale for this product and in no case will Tyco Electronics be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of Tyco Electronics products should make their own evaluation to determine the suitability of each such product for the specific application. TC 597/IP/5 09/06