Using the List of Approved Assemblies

Similar documents
REPRODUCTION OF COPYRIGHTED MATERIALS. Federal copyright law allows educators fair use based on four factors:

ENGINEERING COMMITTEE

Palomar Pacific Chapter Barbershop Harmony Society Mission, Goals, Policies and Procedures

AR Page 1 of 10. Instruction USE OF COPYRIGHTED MATERIALS

Georgia World Congress Center 285 Andrew Young International Blvd Atlanta, GA Engineering Dept: Fax:

Type D mechanical diaphragm

Metuchen Public Educational and Governmental (PEG) Television Station. Policies & Procedures

SECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA

BELLEFONTE BOROUGH AUTHORITY MEETING MINUTES January 3, :00 p. m. 236 West Lamb Street, Bellefonte, PA www. bellefonte.

DISCLAIMER. This document is current at the date of downloading. Hunter Water may update this document at any time.

Cellular Signal Booster

ORANGE COUNTY PUBLIC SCHOOLS ORLANDO, FLORIDA MANAGEMENT DIRECTIVE B-7 GUIDELINES FOR USE OF COPYRIGHTED MATERIALS

Cellular Signal Booster

2.9 Sigma/ 2 Plunger Metering Pumps

Signet 2250 Hydrostatic Level Sensor

A. Guidelines for the Reproduction of Books and Periodicals

Gear Pump Units For single-line centralized lubrication systems

Oxymax W COS71. Technical Information. Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement

TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S

Installation Manual for New or Retrofit Installations

St. Paul Ice Fishing & Winter Sports Show December 1-3, 2017 St. Paul RiverCentre St. Paul, MN EXHIBITOR KIT

INTERNATIONAL TELECOMMUNICATION UNION ).4%2.!4)/.!,!.!,/'5% #!22)%2 3934%-3

Axle Assembly Poke-Yoke

A WILSON ELECTRONICS BRAND DRIVE SLEEK OTR. Cellular Booster For Trucks. User Manual. NEED HELP? support.weboost.com

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 872 LIGHT EMITTING DIODE TRAFFIC SIGNAL LAMP UNITS JULY 19, 2002

Resolution Calling on the FCC to Facilitate the DTV Transition through Additional Consumer Education Efforts

Magnetic Drive Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

In-Line or 75 Ohm In-Line

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 120,000 BTUH S9V2D120D5-SUB-1-EN. March 2016 S9V2D120D5PSAA TAG:

March 14, Gentlemen;

Turning your home into a SMART HOME.

replacement systems. PT-F200 Series Permanent-Installation Projectors Please make these projectors your very first recommendations as new or

Copyright 1970, Shure Brothers Incorporated 27A826 (JK) Printed in U.S.A. C/PEK-2 Instruct ion Manual for Phonograph Evaluation Kit

Blake Grumprecht papers

MICROFOCUS X-RAY SOURCE PROJECT*

MP-7424 Football Scoreboard with MP5000 Console

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS

PDP Series. Positive displacement dosing pump. Sandwich hydraulic diaphragm type with an internal relief-refilling valve SDI. The right dosing choice

Cover Page for Lab Report Group Portion. Boundary Layer Measurements

Be Reel Video Contest RULES AND GUIDELINES

Page Number Official Detail Name Contact Title Primary Contact E mail Secondary Contact E mail

A. The Cable Operator shall provide Subscribers a toll-free or local telephone number for installation, service, and complaint calls.

Oxymax W COS61. Technical Information. Dissolved oxygen measurement Optical sensor acc. to the fluorescence quenching principle

WCHE BTU/Hr Watts

Power Supply Testing: 400 Hz Operation

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Twin City Fan & Blower

CHARLOTTE MECKLENBURG PUBLIC ACCESS CORPORATION

American Coaster Enthusiasts Logo Guidelines

Regulations and Procedures

ADDENDUM NO. 1 CITY OF FREDERICK

WCHE BTU/Hr Watts

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation

Signalling Cable Equivalent Sizes

NOW THEREFORE, in consideration of the mutual covenants and conditions herein contained, the parties hereto do hereby agree as follows:

VERIFICATION TEST PLAN

PARTS LIST FOR CM-1250-A/C 1.5 HP

APPLICATION NOTE. Practical Tips for Using Metalic Time Domain Reflectometers (The EZ Way) What is a Time Domain Reflectometer?

Ecoline S series. Precision solutions for quality production. Innovations for a better world.

Thermo Scientific NESLAB ThermoFlex Recirculating Chillers

Screw pump Series ALLFUEL AFT

Plan for Generic Information Collection Activity: Submission for. National Transportation Safety Board (NTSB).

3M 8900 Single-mode SC Crimplok Connector

Digital Audio and Video Fidelity. Ken Wacks, Ph.D.

KRF EMC Filters Installation, Operation and Maintenance Manual

WCHE BTU/Hr Watts

THE CITY OF WATERLOO SPECIFICATION FOR THE INVESTIGATION OF SANITARY SEWER LATERALS USING CLOSED CIRCUIT TELEVISION CAMERA (CCTV) 2016

National Wire and Cable and National Cable Molding Headquarters Los Angeles California

ENGINEERING COMMITTEE

TABLE OF CONTENTS Bass Bass Bass Bass Bass Bass Bass

1. Entries must be received or post-marked no later than 5:00 p.m., NOVEMBER 25, Faxed, or late entries will not be accepted.

User Manual. Model 979T and 979R Digital Audio Converters

VGA Extender over Cat 6 with Audio Support. Model Extend both video and audio up to 300 meters

Drop Passives: Splitters, Couplers and Power Inserters

UTILITIES (220 ILCS 5/) Public Utilities Act.

Color mixing or White-light LED (Light Emitting Diode) ERS-style product

ADS Basic Automation solutions for the lighting industry

The University of Texas at Austin September 30, 2011

Introduction. Introduction

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

American National Standard for Electric Lamps Specifications for the Chromaticity of Solid-State Lighting Products

Laminar Design Screen Basket

AMENDMENTS TO OPSS 409 (APR 99) CONSTRUCTION SPECIFICATION FOR CLOSED CIRCUIT TELEVISION INSPECTION OF PIPELINES

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL, RADIO FREQUENCY (SERIES SMA (CABLED) - PLUG, PIN CONTACT, CLASS 2)

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

A promise made. A promise kept. The JORDAHL anchor channels are Made in Germany. And this will not change. anchored in quality

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

2. Are there any outside connectivity requirements? No, we will not have a need to allow outside devices to connect

Australian and New Zealand Energy Performance and Marking Requirements for External Power Supplies

EFFECTIVE JANUARY 1st, 2018

May 8-11, Wisconsin State Fair Grounds West Allis, WI EXHIBITOR KIT

PRELIMINARY Sunny Boy 240-US

Description of Bolt Torque Tables

Appendix 1 CLOSED-CIRCUIT TELEVISION INSPECTION

ADVISORY Communications and Media

Agilent 87075C Multiport Test Set Product Overview

3M Cold Shrink Foldback Splice Jacket Kit

Based on our maintenance efforts, during the second quarter of 2018, Comcast s plant was 99.9% reliable.

Transcription:

Using the List of Approved Assemblies Field Test Kits A u t u m n 2 0 0 4 The List of Approved Assemblies is one of the major benefits of Membership in the Foundation. The purpose of the List is to assist the Members of the Foundation in their cross-connection control program. So, any employee of the Member agency/company may use the List. When the Members use it within their own organization or with their own customers it is permissible to reproduce those portions of the List, which are needed. The List is copyrighted, however, and the University would not like to see Members freely distribute copies to others in the industry. In many cases a Member agency needs to pass on the information contained in the List to others as part of the official capacity of the agency. For example, a water agency is a member and requires a customer to install a USC Approved reduced pressure principle assembly (RP). It is permissible in this case for the agency to provide their customer with the data regarding the approved reduced pressure principle assemblies. The 10 th Edition of the Manual of Cross-Connection Control will contain a standard for Field Test Kits. Although the standard has not been finalized yet, this will open up the opportunity for the approval of field test kits. Many have contacted the Foundation with concerns over the new approval of these test kits. The concern is whether or not the gages that are currently being used will meet the requirements of the field test kits under the Tenth Edition of the Manual. At this point it is not possible for us to determine if a particular gage would be acceptable under the Tenth Edition. There are a couple of reasons for this. First of all, the standard for field test kits has not been finalized at this point. The Manual Review Committee is still discussing some of the options and, until these issues are resolved, the final details of the field test kit standard cannot be known. The Manual Review Committee has discussed some details of the field test kit standard. One item is the requirement for accuracy of +/- 0.2 psid. One continued on page six continued on page three I n s i d e C r o s s T a l k Working Together for Safe Water on Cable Using the List Field Test Kits Oversized Backflow Assemblies Frozen Shut Off Valves

T Foundation Membership he Foundation s Membership Program provides many benefits to the Members of the Foundation. These include: a twenty percent discount on Foundation Training Courses for any employee of the Member company/organization, the List of Approved Backflow Prevention Assemblies, printed quarterly, and access to the up-to-the-minute version of the List for those Members with Internet access. Members are encouraged to call the Foundation with technical questions. The Foundation s Engineering Staff is available to assist Members with the various aspects of field testing backflow preventers, installing backflow preventers and administering their cross-connection control program. Below is a list of those who ve become members of the Foundation this past quarter: Azmo Mechanical Inc. Backflow Prevention Services Clean Sewer Lines, Hawaii, Inc. Coastside County Water Devine Construction Eastwind Mechanical Club Eric Bodyfelt Jim White Kenneth Hampton Marina Coast Water District Oak Ridge Fire Department OTCO R.F. Korea Ray s Backflow Testing Roto-Rooter Services Company San Juan Water District Southland Industries University of California, San Diego Val-Matic Corporation Water Education Systems West Maui Land Company Woodfin Sanitary Water Contacting the Foundation Mailing Address: Foundation for Cross- Connection Control and Hydraulic Research University of Southern California Viterbi School of Engineering Kaprielian Hall 200 90089-2531 Phone: 866 545 6340 Toll Free 213 740 2032 FAX: 213 740 8399 e-mail: fccchr@usc.edu Web Site: www.usc.edu/fccchr The Foundation accepts Purchase Orders via mail or fax and credit card orders (Visa, MasterCard, Discover) via telephone and the Web. Two Cross Talk is published by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California for Foundation Members. Limited additional copies are available to Members upon request. 2004 University of Southern California. All rights reserved.

Three Field Test Kits question is whether this will be required for both ascending and descending readings or only descending readings. This question has yet to be resolved by the committee. Also, the question of durability has been discussed and a means of determining the durability of field test kits has not been decided upon. It should be noted, that since there is currently no USC standard for field test kits, there are not any administrative authorities requiring USC approval of field test kits. As with most standards, it is likely that those administrative authorities requiring the USC approved field test kits, will phase this requirement in over time. It is very unlikely that any jurisdiction will start requiring USC approved field test kits as soon as a list of approved test field kits is available. So, although this may be a concern for many, this is not likely to be critical for the next few years. Once the standard is finalized and published in the Tenth Edition, it will still take some time to evaluate field test kits. Once field test kits are evaluated the gages in compliance with the standard can be placed on a list of approved field test kits. The concern of many is that they may be purchasing field testing equipment at this point in time, but don t want to be stuck with some equipment that will not be approved in the next year or two. This is an unfortunate situation, but unavoidable since it is impossible to predict which gages will meet a standard, which hasn t been published yet. Frozen Shut Off Valves T he use of resilient seated shut off valves in approved backflow assemblies has significantly improved the field testing of the assemblies. Having a tight shut off valve has made the job of the field tester considerably easier. Most of the manufacturers of the 2 and the smaller assemblies have selected the fully ported ball valves. These valves have shown themselves to be effective due to the flow characteristics and also the effective shut off capabilities. However, there have been some reports of problems with these valves in actual use. The problem has not been directly with the sealing of the shut off valves, but rather with damage due to freezing on those shut off valves being used in cold climates. Freezing water inside the valves has damaged or continued on page six It should be noted, that since there is currently no USC standard for field test kits, there are not any administrative authorities requiring USC approval of field test kits.

The video is an introduction to the basic concepts of backflow and cross-connection control. The combination of live footage and animation helps to explain these concepts in terms that everyone will understand and enjoy. Working Together for Safe Water on Cable Television E ducating the public on the topic of backflow and cross-connection has become one of the Foundation s more important subjects. The Foundation has several training tools, including videos and computer presentations, to aid the general public in understanding the basic concepts of backflow. One of the Foundation s more popular tools is the general introductory video Working Together for Safe Water. The Working Together for Safe Water video is available in VHS and DVD format. The video is an introduction to the basic concepts of backflow and cross-connection control. The combination of live footage and animation helps to explain these concepts in terms that everyone will understand and enjoy. Over the years the Foundation has received several requests for broadcasting Working Together for Safe Water on local cable television. Using the video on city-run television stations to educate the public on backflow has been done. The Foundation is more than happy to comply with any requests it receives concerning broadcasting Working Together for Safe Water. The Foundation must receive a written request from the sponsoring agency which contains the following: 1. The date(s) and station the video will air on. 2. A commitment not to duplicate the video. 3. A commitment to show the video in its entirety. 4. A commitment to return the video promptly. The Foundation does have 3/4- inch video copies suitable for airing on cable systems. The video is ideal as an introduction to the concepts of backflow for students or employees of agencies involved in cross-connection control. It is also ideal for water consumers who may not understand the reason for backflow prevention requirements. Our spokesman will describe the hydraulics involved in backflow through examples and animation. He will also explain the differences in types of backflow preventers and their applications, as well as the importance of a defensible cross-connection control program. Four

Five Using an Over Sized Backflow Preventer Periodically, the Foundation office receives an inquiry regarding the over sizing of backflow prevention assemblies in a system. The term over sizing, means using a backflow preventer of a larger size than the piping leading into and away from the backflow preventer. For example, one has a two-inch water line and desires to put a four-inch backflow prevention assembly in the two-inch line. Although, this isn t really a problem for the backflow preventer it will provide backflow protection; the reasoning behind this decision must be questioned. The interest in using an over sized assembly usually arises from the desire to provide more flow or pressure to the customer. The thought is that if a larger assembly is used, the assembly doesn t have to work as hard, therefore the pressure loss will be less. The problem is, this simply may not be true. comparison can be done with RP s), the respective pressure loss versus flow rate curves of these assemblies may look something like those in the figures. Although the maximum allowable pressure loss of any sized double check valve assembly is 10 psi (as referenced in Table 10-1, pg 192 Manual), the flow characteristics (i.e., the shape of the curve) vary with the different models and sizes. For our example, the customer is designing their water use at a nominal flow rate of 100 gpm (gallons per minute). If the flow curves from the above figures are superimposed on top of each other (flow characteristics of the two-inch assembly are shown in green and the The thought is that if a larger assembly is used, the assembly doesn t have to work as hard, therefore the pressure loss will be less. The problem is, this simply may not be true. Looking at the example of the fourinch double check valve assembly versus the two-inch double check valve assembly (Note: a similar continued on page seven

With the Excel version of the List being available it is much easier for a Member to make their own specific List and distribute it to their end user. Using the List of Approved Assemblies continued from page one The best way to provide the Approval information is using the Excel version of the List. The top of each column in the Excel version of the list can act as filters to filter the exact information needed. The Member can choose which type of assembly (DC, RP, DCDA, RPDA, AVB, PVB, or SVB) at the top of the column. Then only those particular assemblies show on the List. This can be printed and handed out to the customer. With the Excel version of the List being available it is much easier for a Member to make their own specific List and distribute it to their end user. It also provides concise information for the customer. The filters may also be used in combination with one another. Should the Member have a customer that needs to install a 2 double check valve assembly installed vertically and approved under the 9 th edition of the Manual or later, all of this information can be filtered on the Excel sheet. The Member can have a list of all the approved assemblies matching the criteria, by just clicking at the top of each applicable column and selecting the appropriate variable (e.g., size-2, orientation-vertical up, edition of the Manual-9, and type of assembly-dc). This can then be printed for the customer and they have exactly what they need for their purposes. What is not permissible is for a Member to reproduce the List and distribute it indiscriminately. Basically, it is permissible for the Member agency to get the information into the hands of the end user in the official capacity of the agency. It is not permissible to provide the list to other agencies so they could, in turn, provide it to their customers. We hope this information helps you to carry out your cross-connection control program more effectively. Should you have any further questions, please contact our office. Frozen Shut Off Valves continued from page three destroyed the operation of the valve. Even with the winterizing of a water line, that is the water being drained out of the water line itself, the ball valves may be left in the fully opened or fully closed position. When this is done there may be a small volume of water trapped between the outside of the ball and the body. With this trapped volume of water freezing, the resulting damage can be significant. Seals or components may be distorted and in extreme cases the body housing itself could be cracked. As seen in the figure, with the valve in the opened (see figure on page 7) or closed position, the small pocket of water is trapped in place. Where winterizing of a water line is necessary, it is highly recommended that the ball valve be left in a partially opened position. Leaving the valve at a 45 degree angle will leave this continued on page seven Six

Seven Frozen Shut Off Valves continued from page six pocket unsealed and the trapping of water will be significantly reduced, thus eliminating any damage to the valve. Ideally backflow preventers on cold water application should be kept in an area protected from the harsh environment. However, this is not always the case. With winter approaching, many will be winterizing portions of their systems including backflow preventers and their shut off valves. When this is done, it is advisable to leave the ball valves in the partially open position, in order to minimize the potential for trapping water in the ball valve. This should help prevent freeze damage to the ball valves. Using an Oversized Backflow Preventer continued from page five four-inch assembly shown in blue), we can directly compare the two curves. At the desired flow rate of 100 gpm it can be seen that the pressure loss of the twoinch assembly is several psi less than the four-inch assembly. For our example the four-inch assembly only provides a lower pressure loss when the rate of flow exceeds the 160 gpm rated flow of the two-inch. Two-inch water meters typically have a safe maximum operating capacity of 160 gpm, so if flow rates greater than this are needed, then a larger service line and water meter should be utilized. Ideally backflow preventers on cold water application should be kept in an area protected from the harsh environment. Although the specifics may vary with each manufacturer, assemblies, in general, behave in the manner shown on these curves. At the lower flow rate the four-inch check valves may just be in the opening phase of the flow (signified by the rising slope in the flow curve), thus having a higher pressure loss. In addition, should the check valves only open a small amount, there is a higher likelihood of wire-drawing (i.e., high velocity erosion) the seats. So, although over sizing backflow prevention assemblies may not affect the ability of the assembly to prevent backflow, it will rarely, if ever, provide a benefit.

Training Courses Upcoming Events Tester Course 10-14 January 2005 16-20 May 2005 11-15 July 2005 Specialist Course ABPA- Oregon Chapter Conference Wilsonville, OR 20 January 2005 Backflow Industry Product Fair 22 March 2005 ABPA Annual Conference and Tradeshow Orlando, FL 8-11 May 2005 24-28 January 2005 Incline Village, NV 7-11 March 2005 25-29 July 2005 Foundation for Cross-Connection Control and Hydraulic Research University of Southern California Kaprielian Hall 200 Los Angeles, California 90089-2531 First Class US Postage PAID University of Southern California