LED MOVING HEAD LedWash. 36 x 10w RGBW 4in1 Zooming USER MANUAL. Version 1.0 beta

Similar documents
BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

Eternal Lighting. Premier150 Spot. User Manual

LED Thunder S-150 Code 1097

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

Fusion 120 Zoom. User Manual. Order code: EQLED068

DESIGN 250 PR PR LIGHTING LTD. No. 571, Yingbin Road, Dashi Panyu, Guangzhou, China

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

SquareLED - Aura Bar & Matrix Beam Light 100

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

LED Spot 300W. Please read this user manual before your operation

Spectra Batten (Order code: LEDJ95)

PILOT 1200 WASH PR-2901

PILOT 250 PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

ORDER CODE: EQLED65 USER MANUAL

Fixture One XLR Signal Cable One Omega Clamp - Two Safety Chain One User Manual - One

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Stage Wash 7x 10W LED Moving Head (RGBW)

Led Dynamic DMX Tri Curtain Manual

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

WASH MOVING HEAD M7W15RGBW USER MANUAL. For safety, please read this user manual carefully before initial use.

Mini LED Pin Spot Light Model: PLS00571

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

192 Channel DMX Controller

BEAM MOVING HEAD WITH 100W OSRAM HRI LAMP AND 8-FACET PRISM USER GUIDE

Stratos Duo RGB. User Manual. Order code: EQLED371

AuraBeam 150 LED. User Manual KEEP THIS MANUAL FOR FUTURE NEEDS

USER MANUAL. TS-3 DMX-Scanner. For your own safety, please read this user manual carefully before you initial start-up.

www. eklights.com Guangzhou Liangyi Lighting Equipments Co.,Ltd. 37 Gongyedadao, Xinhua, Huadu, Guangzhou PC:510800

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL

User Manual MAINTENANCE AND CLEANING. CAUTION Disconnect from mains before starting maintenance operation. KEEP THIS MANUAL FOR FUTURE NEEDS

LED-PAR200B USER MANUAL. COLORsplash 200B

LED Spot Light User Manual Model LS90 Big Dipper Laser Science And Technology Co., Ltd Please read this manual carefully before operating

MHL-1410WISPOT 14X 10W QUAD DMX 2.4GHZ

ElektraLite lightstream

LED Pixel Track Pro ORDERCODE 42205

LED Spere Direct Control 30 ORDERCODE 41125

DH551C/DH550C/DL550C Double Sided Display User Manual

LED SPOT HEAD USERS GUIDE

80W SPOT MOVING HEAD CYCLONE-80 USER GUIDE April 2014 version

Stage Right Party 10-Watt Mini Beam Moving Head LED Light

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

LED-BANK4 USER MANUAL. COLORbank 4

LED SPOT HEAD USERS GUIDE

180w led gobo moving USER MANUAL

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

USER MANUAL Table of Contents

USER MANUAL Table of Contents

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc..

Hex-color RGBAW+UV LED strip light

DMX LED light effect with 4 lenses

SUPER LED F4.7 VW Vari-White INSTRUCTION MANUAL

LEDWash RGBW USER MANUAL

JunoScan MK-II LED scanner. user manual

Mini Stage Par 4 8W QCL RGBA/RGBW 25 /40 LED PAR. user manual

TABLE OF CONTENTS Important Safety Instructions Package Content Setting Up the Display Trouble shooting Specifications Product Dimensions

LED IP65 Slimline Par RGBWA +UV 7x12W

9X9W LEDS BLINDER WITH LCD DISPLAY USER GUIDE December 2013 Version 1.12

LED Par 36 COB RGBW 12W, LED Par 46 COB RGBW 20W, LED Par 64 COB RGBW 60W, LED Par 56 COB RGBW 30W LED PAR. user manual

aorun manual V2.0 MARCH 2018

Color Ground 12T 16 A USER MANUAL 5 APPENDIX 5.1 TROUBLE SHOOTING 5.2 MAINTENANCE LED MODULE. Version 1.0 SITUATION CAUSE ACTION 5 APPENDIX

LED Pot 12 1W RGBW LED PAR. user manual

MH-X50+ LED spot moving head. user manual

LED Moving Head GTD-LMZ1512. User s Manual

LED BEAM HEAD USERS GUIDE

RIO TRI PAR MICROH. Information. Technical 104 F(40 C) 9.6 in (245 mm) Width. 9.6 in (245 mm) Height. 8.0 in (205 mm) Weight

Product Manual. Designed and Manufactured in the UK by Optikinetics

YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING. SAVE IT FOR FUTURE REFERENCE

PRODUCT SPECIFICATIONS

Quick Reference Guide

Elektralite LED Cool White Dazer

PRODUCT SPECIFICATIONS

Venus W36 LED Moving Wash

Ref. No.: LCB-48IP LED COLORUNIT 16X3W TRI DMX

BSL MAGIC ZOOM 7 USERS GUIDE

4LEDKIT-DJ USER MANUAL. LED Tricolor 4-PAR Lighting Kit. Please read this manual carefully and proper take care of this manual.

aorun manual V1.0 OCTOBER 2017

TABLE OF CONTENTS PART 5 APPENDIX TROUBLE SHOOTING MAINTENANCE A CTIVATE THE PASSWORD...13.

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 7

BSL HELIOS USERS GUIDE

Octagon Theater CW/WW/A 20 6W LED PAR. user manual

SAFETY WARNINGS AND GUIDELINES INTRODUCTION CUSTOMER SERVICE

USER MANUAL (SSDL-3201RGB)

L632RG. User's Manual. DMX Address Chart RG 8 GOBO TWINKLING LASER SHOW SYSTEM

6X3W TRICOLOUR LEDS COMPACT PROJECTOR

MONOPRICE. SoftStage 80-Watt COB LED Stage PAR (RGB) with 30 and 80 Lenses. User's Manual P/N

Owner Handbook Neptune Tumbler. Owner Handbook. Neptune Tumbler

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

LED Gobo Projector 25W ORDERCODE 40711

Snapshot. LED Mushroom USER MANUAL. OK on Dimmer Outdoor OK Sound-Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User-Serviceable

Theatrik HUSH PAR. Blizzard Lighting, LLC Waukesha, WI USA Copyright (c) 2013

USER S MANUAL

PRODUCT SPECIFICATIONS

DMX Operator 192-channel lighting controller

Image Marketing Projector 1.6

Transcription:

LED MOVING HEAD LedWash x 10w RGBW in1 Zooming This product manual contains important information about the safe installation and use of this projector. Please read and follow these instructions carefully and keep this manual in a safe place for future reference. USER MANUAL Version 1.0 beta

LED MOVING HEAD LedWash X 10w RGBW in1 LED Moving Head Zoom INDEX SAFE USAGE OF THE PROJECTOR INSTALL THE PROJECTOR POWER SUPPLY-MAINS CONTROL CONNECTION DMX TERMINATOR SETUP OPTIONS-PROJECTOR CONFIGURATION TO SET THE DMX START ADDRESS OPERATION MENU DMX PROTOCOL MAINTENANCE KEEPING THE PROJECTOR CLEAN TROUBLESHOOTING TECHNICAL DATA 5 5 7 11 1 1 1 1 PHOTOMETRIC DIAGRAMS 1

SAFE USAGE OF THE PROJECTOR When unpacking and before disposing of the carton check there is no transportation damage before using the projector. Should there be any damage caused by transportation, consult your dealer and do not use the apparatus. The projector is for indoor use only, IP0. Use only in dry locations. Keep this device away from rain and moisture, excessive heat, humidity and dust. Do not allow contact with water or any other liquids. DO NOT mount the projector directly onto in ammable surface The projector is only intended for installation, operation and maintenance by quali ed personnel. The projector must be installed in a location with adequate ventilation, at least 50cm from adjacent wall surfaces. Be sure that no ventilation slots are blocked. Do not project the beam onto in ammable surfaces, minimum distance is 5m 5m Avoid direct exposure to the light from the lamp. The light is harmful to the eye. Do not attempt to dismantle and/or modify the projector in any way. Electrical connection must only be carried out by quali ed personnel. Before installation, ensure that the voltage and frequency of power supply match the power requirements of the projector. It is essential that each projector is correctly earthed and that electrical installation conforms to all relevant standards. Do not connect this device to any other types of dimmer apparatus. Make sure that the power-cord is never crimped or damaged by sharp edges. Never let the powercord come into contact with other cables. Only handle the power-cord by the plug. Never pull out the plug by tugging the power-cord. Keep a projector s optical system clean. Do not touch LED lens with bare hands. The projector should always be installed with a secondary safety xing. A safety cord is supplied for this; it should be attached as shown in installing the projector section. Shields and lens shall be changed if they have become visibly damaged to such an extent than their effectiveness is impaired, for example by cracks or deep scratches. LED lamps should be replaced if damaged or having reached life limit. Exterior surface temperatures of the luminaire after 5 minutes operation is55, when steady state is achieved 70, There is no user serviceable parts inside the projector, do not open the housing and never operate the projector with the covers removed. If you have any questions, don t hesitate to consult your dealer or manufacturer. Always disconnect a projector from the POWER when not in use or before cleaning or any

INSTALL THE PROJECTOR WARNING SAFETY CORD GO THROUGH THE HOLE FOR SAFETY Take 1 clamp and 1 safety cord (the clamp and safety cord are optional accessories). Hang the xture on the structure and fasten the screws attached to the clamp. (See the WARNING on the underside of the base as shown above) Always ensure that the projector is rmly anchored to avoid vibration and slipping whilst functioning. Always ensure that the structure that you are going to mount the projector is secure and is strong enough to support a weight of each projector. WARNING: The projector MUST be lifted or carried by the HANDLES instead of clamps. For safety the safety cord should afford 10 times of the unit s weight.

POWER SUPPLY-MAINS Connect the power cord as follows: L (live) =brown E (earth) =yellow/green N (neutral) =blue Use the plug provided to connect the mains power to the projector paying attention to the voltage and frequency marked on the panel of the projector. It is recommended that each projector be supplied separately so that they may be individually switched on and off. IMPORTANT It is essential that each projector is correctly earthed and the electrical installation conforms to all relevant standards. CONTROL CONNECTION DMX OUT DMX IN PIN 1 1 DMX51 PIN FUNCTION 1 GND DATA- DATA+ 5PIN DMX OUT 5 1 1 DMX IN 5 DMX51 PIN FUNCTION 1 GND DATA- DATA+ N/C 5 N/C Connection between controller and projector and between one projector and another must be made with a core-screened cable, with each core having at least a 0.5mm diameter. Connection to and from the projector is via cannon pin (which are included with the projector) XLR plugs and sockets. The XLR's are connected as shown in the gure above. Note: care should be taken to ensure that none of the pins touch the metallic body of the plug or each other. The body of the plug is not connected in any way. The projector accepts digital control signals in protocol DMX51 (1990). Connect the controller s output to the rst xture s input, and connect the rst xture s output to the second xture s input and connect the rest xtures in the same way. Eventually connect the last xture s output to a DMX terminator as shown in the gure below. 5

DMX TERMINATOR In the Controller mode, at the last xture in the chain, the DMX output has to be connected with a DMX terminator. This preventselectrical noise from disturbing and corrupting the DMX control signals. The DMX terminator is simply an XLR connector with a 10Ω(ohm) resistor connected across pins and, which is then plugged into the output socket on the last projector in the chain. The connections are illustrated below. 10Ω 1 DMX TERMINATOR CONNECTION Connect a 10Ω (OHM) resistor across pins and in an XLR plug and insert into the DMX out socket on the last unit in the chain. PIN PIN SETUP OPTIONS-PROJECTOR CONFIGURATION FUNC DOWN UP ENTER Projector con guration can be set conveniently via press button switch and LCD display. To browse or change its setup options, Press button ENTER to unlock panel. Menu will be displayed on the screen, each menu has it own sub-menu. Each menu has speci c function, Please refer to Operation Menu for details. Press button UP or DOWN if you want to browse or change through the various Setup Options. Press button ENTER to save your settings or enter the next menu. Press button UP or DOWN to change values.(add or subtract) Press button FUNC, it will return to the upper menu one by one. TO SET THE DMX START ADDRESS Each projector must be given a DMX start address so that the correct projector responds to the correct control signals. This DMX start address is the channel number from which the projector starts to listen to the digital control information being sent out from the controller. The xture have DMX modes. There are simple mode, standard mode and extended mode. For example standard mode has 15 channels, so set the No. 1 projector s address 001, No. projector s address 01, No. projector s address 01, No. projector s address 0 and so on. Launch the projector. Press button ENTER more than 5 seconds to unlock panel. Press button ENTER to display DMX address. Press button UP or DOWN, you can set the address. Press button ENTER to con rm, which means the projector has saved the Start Address automatically, when powered on next time, it will display the value saved last time. Press button UP or DOWN to change values.(add or subtract) Press button FUNC, it will return to the upper menu one by one.

OPERATION MENU Level 1 Level Level Level Led Zoom DMX Address = 001 Led Zoom Auto = P01:S01 Led Zoom Master = P01:S01 Led Zoom Slave = P01:S01 Led Zoom Slave same Led Zoom Music = P01:S01 Address Setup Address Setup Address = 001 Reset Reset Complete Pan Titl Red Greenl Blue White Pan = 000 Tilt = 000 Red = 000 Green = 000 Blue = 000 White = 000 7

Level 1 Level Level Level Operation Mode Zoom Mode = DMX Mode Zoom = 000 DMX Mode = Short Mode DMX Mode = Standard Mode Mode = Auto Mode Mode = Master Mode Mode = Slave SYNC Mode DMX Mode = Extended Mode Select Program Program = 001 Select Program Program =001 Select Program Program = 001 Option Settings Mode = Slave SAME Mode Mode = Music Mode Option Pan Tilt Swap Option Pan Invert Option Tilt Invert Select Program Program = 001 Pan Tilt Swap =OFF Pan Tilt Swap =ON Pan Invert =OFF Pan Invert =ON Tilt Invert =OFF 8

Level 1 Level Level Level Option Display Setup Option Lost DMX Tilt Invert =ON Display Setup Delay Off Display Setup Display Invert Display Setup Language Lost DMX =Clear Value Lost DMX =Hold Value Delay Off = Disable Delay Off = Enable Display Invert = OFF Display Invert = ON Language = English Language = 简体中文 Advanced Access Code Access Code Code = 000 注 :Code = 008 Pan Tilt Red Green Pan = +000 Tilt = +000 Red = 000 Green = 000 9

Level 1 Level Level Level Blue White Blue = 000 White = 000 Information Mic Sensitivity Temperature Mic Sensitivity =080% Temperature =05C Fixture Hours Fixture Hours =00000 H Reset Hours =NO Reset Hours =YES Product ID View DMX Value Version Product ID = Y************ View DMX Value Channel 001 = 000 Version =1.00 Load Defaults Load Defaults =NO Load Defaults =YES Note: There is only one Projector to be set as a Master in a signal Cable. If Master s functions used, Please disable DMX control signal. When multiple projectors work together in synchronous control state, Parameters can be transmitted from the master projector to the slave projectors such as DMX channel mode, Display setting status and operation mode (User memory data is included). Before parameters transmitted, the projector which will send parameters should be set as a Master and others be as Slaves. 10

DMX PROTOCOL Short mode Mode/Channel Standard mode Extended mode FUNCTION VALUE DESCRIPTION 1 1 1 Pan Pan Moving 0-50 Degree Pan Fine Pan Fine Moving Tilt Tilt Moving 0-70 Degree Tilt Fine Tilt Fine Moving 5 5 Move Speed Moving Speed From Fast To Slow Dimmer RGBW All Dimmer 7 Dimmer ( 8 Bit ) RGBW All Fine Dimmer 7 8 Strobe 0~9 1 No Strobe Strobe From Slow To Fast 5 8 9 Red ( 8 Bit ) Red control 10 Red ( 1 Bit ) Red ne control 9 11 Green ( 8 Bit ) Green control 1 Green ( 1 Bit ) Green ne control 7 10 1 Blue ( 8 Bit ) Blue 1 Blue ( 1 Bit ) Blue ne control 8 11 15 White ( 8 Bit ) White 1 White ( 1 Bit ) White ne control 9 1 17 Zoom Zoom from Distant to Near 0~9 No function 10~19 700K 1 18 Color Temperature 0~9 0~9 00K 00K 0~9 500K 50~59 8000K Color Temperature from Slow to High 1 19 Virtual Color Wheel 0~9 1 Virtual Color ( B>BG>G>GR>R>RB>B ) 0~ 5~9 50~7 10 15 0 Function " 停留于某值的时间大于 5 秒 " 75~99 100~1 15~19 Reset: Complete 150~17 175~199 00~ 5~55 11

MAINTENANCE To prolong a Projector s life, Regular maintenance should be done for its LED optical System to ensure that the system be in best operational condition. If the projector does not function, check the fuses on the power socket of the projector, if burned, they should only be replaced by fuses of the same speci cation. Should these be damaged call a quali ed technician before replacement. The projector has thermal protection device that will switch off the projector in case of overheating, should this occur, check if the fans work normally or fan and fan shield are blocked by dust. If the projector not operational, call a quali ed technician. After cleaned and repaired, the projector can be restarted. Any maintenance work should only be carried out by quali ed technicians. KEEPING THE PROJECTOR CLEAN It de nitely necessary to keep a projector clean for its reliable use. Cooling fans and their shield should be cleaned every 15days. LED lamps lens and cover should be cleaned regularly for optimized light output. Cleaning frequency depends on how often a projector is used and its operational environment. A soft cloth and typical glass cleaning products should be used in cleaning. It is recommended to clean the external optics at least once every 0 days. Do not use any organic solvent, e.g. alcohol, to clean t housing of the apparatus. TROUBLESHOOTING PROBLEM The projector can t be started The lamp can be started, but LED lampsare off and not controlled A projector s lamps are on but it doesn t respond to the controller The beam appears dim and its brightness slows sharply ACTION > Power Cable not connected well > Power supply damaged or not connected well, a quali ed Technician should be required > Control board not connected well and a quali ed Technician should be > LED boards not connected properly, a quali ed technician is needed > Make sure that the projector s start address is correctly set > Replace or repair the DMX cable. > Ambient temperature too high which result in a projector overheating, necessary ventilating measures needed. 1

TECHNICAL DATA VOLTAGES: 100V~0V AC,50/0Hz POWER CONSUMPTION: 00W@0V LED: Power consumption 10W(RGBW) Quantity pcs Manufacturers Rated LED Life 50000 Hours COLOURS: RGBW linear color mixing COLOR TEMPERATURE CORRECTION: Linear color temperature correction from 700K to 8000K DIMMER: 0-100% linearly adjustable STROBE: Electronic Strobe 0 ~5F.P.S PAN AND TILT: PAN(0 ~50 ) and TILT(0 ~70), User-selectable Pan/Tilt ranges ZOOM ANGLE: 1 ~70 CONTROL: DMX51, pins interfaces RDM Control Protocol 10channels in short mode, 15channels in standard mode, and 0 channels in extended mode Master/Salve Synchronous Control Mode: DMX51 / Master-Slave / Auto / Custom / Sound HOUSING: Flame retardant engineering plastic shell/cast aluminum, Ip0 WORK ENVIRONMENT TEMPERATURE: -10 C~0 C CARTONS PACKING DIMENSION: Inner: 10x0x50 (mm) Outer: 5x5x80 (mm) WEIGHT: Net weight :9.Kg Gross Weight: 1.0Kg 1

DIMENSIONS (mm): 0 85 75 5 0 0 80 8 0 PHOTOMETRIC DIAGRAMS 0 1 5 8 10 Distance (m) Beam opening(m) 0 70 1 0 0 0. 1. 0..8 0.. 1.0 1..1 Diameter (m) - 1 7.0 11. 1 Diameter (m) - 70 1

Min.zoom (1 ) Distance (m) 1 5 Red 0/01 50/0 / Green Blue 70/7 90/87 880/8 05/8 10/1 50/. Intensity (center) Lux/Footcandles White 17/17 8/78 10/9 Distance (m) R+G+B+W 1 5 8 10 17800/15 5000/5 00/05 790/7. 0/0 00/19 Intensity (center) Lux/Footcandles 500 (Lux) Distance=m (Foot-candles) 000 18 1500 10 1000 9 500 7 0 0 1.0 0.9 0.8 0.7 0. 0.5 0. 0. 0. 0.1 0 0.1 0. 0. 0. 0.5 0. 0.7 0.8 0.9 1.0 Diameter (m) Red Green Blue White R+G+B+W 15

Max.zoom( 70 ) Distance (m) 1 5 Red 110/1 10/15 70/.5 Green Blue 110/150 8/ 19/18 75/7 5/. 1/1. Intensity (center) Lux/Footcandles White 17/17 17/1 9/. Distance (m) R+G+B+W 1 5 8 10 00/90 1100/10 510/7 00/19 80/7. 0/5. Intensity (center) Lux/Footcandles 00 (Lux) Distance=m 5 (Foot-candles) 80 5 0 0 10 11 0 5.0.5.0.5.0.5.0 1.5 1.0 0.5 0 0.5 1.0 1.5.0.5.0.5.0.5 0 5.0 Diameter (m) Red Green Blue White R+G+B+W 1