SECQ Test Method and Calibration Improvements

Similar documents
On Figure of Merit in PAM4 Optical Transmitter Evaluation, Particularly TDECQ

64G Fibre Channel strawman update. 6 th Dec 2016, rv1 Jonathan King, Finisar

Refining TDECQ. Piers Dawe Mellanox

Proposed reference equalizer change in Clause 124 (TDECQ/SECQ. methodologies).

802.3cd (comments #i-79-81).

Thoughts about adaptive transmitter FFE for 802.3ck Chip-to-Module. Adee Ran, Intel Phil Sun, Credo Adam Healey, Broadcom

10GBASE-LRM Interoperability & Technical Feasibility Report

TDECQ update noise treatment and equalizer optimization (revision of king_3bs_01_0117) 14th February 2017 P802.3bs SMF ad hoc Jonathan King, Finisar

100GBASE-SR4 Extinction Ratio Requirement. John Petrilla: Avago Technologies September 2013

PAM4 signals for 400 Gbps: acquisition for measurement and signal processing

Measurements Results of GBd VCSEL Over OM3 with and without Equalization

Comparison of NRZ, PR-2, and PR-4 signaling. Qasim Chaudry Adam Healey Greg Sheets

Open electrical issues. Piers Dawe Mellanox

100G SR4 Link Model Update & TDP. John Petrilla: Avago Technologies January 2013

Draft 100G SR4 TxVEC - TDP Update. John Petrilla: Avago Technologies February 2014

Receiver Testing to Third Generation Standards. Jim Dunford, October 2011

CDAUI-8 Chip-to-Module (C2M) System Analysis #3. Ben Smith and Stephane Dallaire, Inphi Corporation IEEE 802.3bs, Bonita Springs, September 2015

100Gb/s Single-lane SERDES Discussion. Phil Sun, Credo Semiconductor IEEE New Ethernet Applications Ad Hoc May 24, 2017

In support of 3.5 db Extinction Ratio for 200GBASE-DR4 and 400GBASE-DR4

Systematic Tx Eye Mask Definition. John Petrilla, Avago Technologies March 2009

400G-FR4 Technical Specification

100G-FR and 100G-LR Technical Specifications

Validation of VSR Module to Host link

The Case of the Closing Eyes: Is PAM the Answer? Is NRZ dead?

Next Generation Ultra-High speed standards measurements of Optical and Electrical signals

Transmitter Specifications and COM for 50GBASE-CR Mike Dudek Cavium Tao Hu Cavium cd Ad-hoc 1/10/18.

LOW POWER DIGITAL EQUALIZATION FOR HIGH SPEED SERDES. Masum Hossain University of Alberta

200GBASE-DR4: A Baseline Proposal for the 200G 500m Objective. Brian Welch (Luxtera)

Further work on S/N Budget Channel specification May 8

Further Investigation of Bit Multiplexing in 400GbE PMA

Brian Holden Kandou Bus, S.A. IEEE GE Study Group September 2, 2013 York, United Kingdom

Component BW requirement of 56Gbaud Modulations for 400GbE 2 & 10km PMD

50 Gb/s per lane MMF baseline proposals. P802.3cd, Whistler, BC 21 st May 2016 Jonathan King, Finisar Jonathan Ingham, FIT

An Approach To 25GbE SMF 10km Specification IEEE Plenary (Macau) Kohichi Tamura

Combating Closed Eyes Design & Measurement of Pre-Emphasis and Equalization for Lossy Channels

Combating Closed Eyes Design & Measurement of Pre-Emphasis and Equalization for Lossy Channels

Improved extinction ratio specifications. Piers Dawe Mellanox

New Serial Link Simulation Process, 6 Gbps SAS Case Study

40G SWDM4 MSA Technical Specifications Optical Specifications

SMF Ad Hoc report. Pete Anslow, Ciena, SMF Ad Hoc Chair. IEEE P802.3bm, Geneva, September 2012

Ali Ghiasi. Nov 8, 2011 IEEE GNGOPTX Study Group Atlanta

TP2 and TP3 Parameter Measurement Test Readiness

Further Clarification of FEC Performance over PAM4 links with Bit-multiplexing

MR Interface Analysis including Chord Signaling Options

BER margin of COM 3dB

100G CWDM Link Model for DM DFB Lasers. John Petrilla: Avago Technologies May 2013

Summary of NRZ CDAUI proposals

The Challenges of Measuring PAM4 Signals

CDAUI-8 Chip-to-Module (C2M) System Analysis. Stephane Dallaire and Ben Smith, September 2, 2015

100G EDR and QSFP+ Cable Test Solutions

Baseline proposal update

CU4HDD Backplane Channel Analysis

Further information on PAM4 error performance and power budget considerations

40G SWDM4 MSA Technical Specifications Optical Specifications

Improving the Performance of Advanced Modulation Scheme. Yoshiaki Sone NTT IEEE802.3bs 400 Gb/s Ethernet Task Force, San Antonio, Novenver 2014.

Link Budget Analysis for Broadband Services in IEEE b

Ali Ghiasi. Jan 23, 2011 IEEE GNGOPTX Study Group Newport Beach

Clause 74 FEC and MLD Interactions. Magesh Valliappan Broadcom Mark Gustlin - Cisco

Transmission Strategies for 10GBase-T over CAT- 6 Copper Wiring. IEEE Meeting November 2003

Practical Receiver Equalization Tradeoffs Applicable to Next- Generation 28 Gb/s Links with db Loss Channels

Keysight N4917BSCA Optical Receiver Stress Test Solution 400 Gb/s Ethernet - IEEE 802.3bs

Thoughts on 25G cable/host configurations. Mike Dudek QLogic. 11/18/14 Presented to 25GE architecture ad hoc 11/19/14.

Draft Baseline Proposal for CDAUI-8 Chipto-Module (C2M) Electrical Interface (NRZ)

IEEE P802.3bs D Gb/s & 400 Gb/s Ethernet Initial Working Group ballot comments

Update on FEC Proposal for 10GbE Backplane Ethernet. Andrey Belegolovy Andrey Ovchinnikov Ilango. Ganga Fulvio Spagna Luke Chang

Transmitter Preemphasis: An Easier Path to 99% Coverage at 300m?

Performance comparison study for Rx vs Tx based equalization for C2M links

500 m SMF Objective Baseline Proposal

32 G/64 Gbaud Multi Channel PAM4 BERT

Project: IEEE P Working Group for Wireless Personal Area Networks (WPANs)

New Metric Offers More Accurate Estimate of Optical Transmitter s Impact on Multimode Fiber-optic Links

100G PSM4 & RS(528, 514, 7, 10) FEC. John Petrilla: Avago Technologies September 2012

Comment #147, #169: Problems of high DFE coefficients

PAM8 Baseline Proposal

USB 3.1 ENGINEERING CHANGE NOTICE

Analyzing GBaud PAM4 Optical and Electrical Signals APPLICATION NOTE

40GBASE-ER4 optical budget

10 Gb/s Duobinary Signaling over Electrical Backplanes Experimental Results and Discussion

100G BASE-KP4 Interference tolerance ad hoc January 22 Mike Dudek Qlogic Charles Moore Avago

Proposal for 400GE Optical PMD for 2km SMF Objective based on 4 x 100G PAM4

Issues for fair comparison of PAM4 and DMT

Achieving BER/FLR targets with clause 74 FEC. Phil Sun, Marvell Adee Ran, Intel Venugopal Balasubramonian, Marvell Zhenyu Liu, Marvell

100G SR4 TxVEC - TDP Update (D2.1 comment 94) John Petrilla: Avago Technologies March 2014

Baseline Proposal for 200 Gb/s Ethernet 40 km SMF 200GBASE-ER4 in 802.3cn

PCI Express. Francis Liu Project Manager Agilent Technologies. Nov 2012

Maps of OMA, TDP and mean power. Piers Dawe Mellanox Technologies

AMI Modeling Methodology and Measurement Correlation of a 6.25Gb/s Link

802.3bj FEC Overview and Status IEEE P802.3bm

IEEE P802.3bs D Gb/s & 400 Gb/s Ethernet 2nd Working Group recirculation ballot comments

N4917BACA Optical Receiver Stress Test Solution 100 Gb/s Ethernet

Problems of high DFE coefficients

100G MMF 20m & 100m Link Model Comparison. John Petrilla: Avago Technologies March 2013

Technical Feasibility of Single Wavelength 400GbE 2km &10km application

100GBASE-DR2: A Baseline Proposal for the 100G 500m Two Lane Objective. Brian Welch (Luxtera)

De-correlating 100GBASE-KR4/CR4 training sequences between lanes

Exceeding the Limits of Binary Data Transmission on Printed Circuit Boards by Multilevel Signaling

Optical transmission feasibility for 400GbE extended reach PMD. Yoshiaki Sone NTT IEEE802.3 Industry Connections NG-ECDC Ad hoc, Whistler, May 2016

Using SOAs as Booster and/or Pre-Amplifier for 4x25-Gb/s 40-km 1310-nm PMD

RS-FEC Codeword Monitoring for 802.3cd

CAUI-4 Chip to Chip and Chip to Module Applications

Transcription:

SECQ Test Method and Calibration Improvements IEEE802.3cd, Geneva, January 22, 2018 Matt Sysak, Adee Ran, Hai-Feng Liu, Scott Schube In support of comments 82-84

Summary We are proposing revising the wording in the description of the stressed receiver sensitivity test in 802.3cd Clause 140 to more clearly bound test conditions for PAM4 optical interfaces The current SRS test definition in the standard does not place any bounds on noise, ISI, or other stressors that make up the SRS conformance test signal (reference transmitter). Our analysis indicates that this opens up the real possibility of interoperability failures between compliant transmitters and receivers in actual field operation. We believe that the proposed changes will address these interoperability cases 2

Outline What s written in the draft standard now regarding stressed receiver sensitivity conformance signal / reference transmitter Issues with the draft standard text in its definition of stressed receiver sensitivity reference transmitter characteristics Why it matters interoperability gaps Simulations of Rx BER performance of different types of receivers in the face of different types of SRS conformance signals compliant with the current standard Our proposed change to address these gaps Other implications and anticipated questions 3

Disclaimer Different types of receive equalizers were used in the simulations shown here. These equalizers were used for the sole purpose of showing the difference in performance of two generic receiver types ( more equalization and less equalization ) as they relate to interoperability cases, and are not meant as an argument for or against any particular equalizer Any resemblance to any commercial equalizer implementation is purely accidental 4

What s Written in the Draft Standard Now: Current SRS Test Definition in 802.3cd The stressed receiver test outlined for PAM4 PMDs in 802.3cd specifies a stressed receiver conformance test signal (a.k.a. reference transmitter) with a given SECQ The reference transmitter is calibrated to the specified SECQ value by adding ISI, sinusoidal jitter (SJ), sinusoidal interference (SI), and Gaussian noise (GN) The current reference Tx calibration for this test outlined in 802.3cd+bs defines that ISI should be added until at least 50% of the SECQ value is reached, but does not otherwise define the makeup of the SECQ contributing stressors nor reference Tx characteristics. 5

Issues With the Draft Standard Text (1) The SRS conformance signal is defined giving the guidance that ISI/BW impairments should be added until at least 50% of the SECQ value. This means that up to 100% of the SECQ stress could be from ISI under the current definition. There is no guidance/bounds on the baseline characteristics of the reference Tx before stressors are added, so that the baseline reference Tx per the text could be, for example: At 50% of the SECQ limit, meaning that no ISI stressors need to be added At 100% of the SECQ limit, meaning that no additional stressors are added Note that the reference Tx SECQ is undefined and could be made up of any combination of stressors, including ones not mentioned in the standard The amount of Gaussian noise and sinusoidal interference that make up the remaining 50% (or less, or more see above) of the SRS test signal SECQ are undefined, as is the ratio between the two stressors In combination, these mean that the SECQ makeup/composition of the SRS reference transmitter is essentially undefined, other than the total SECQ value 6

Issues With the Draft Standard Text (2): Examples Under the current SRS conformance signal description in the draft, all of the SRS conformance test signals / reference transmitters shown below would be equally compliant (leaving SJ out for simplicity small contributor to SECQ). These are just a few of an infinite number of examples that could be considered. Note: Reference Tx baseline SECQ = SECQ before any outside stressors are added; inherent minimum SECQ is from SECQ filter/algorithm itself (~0.6 db) SECQ limit/spec 50% Added stressors made up entirely of Gaussian noise Added ISI Reference Tx baseline SECQ made up of a mix of ISI/BW and noise Inherent minimum SECQ Added stressors made up entirely of ISI Reference Tx baseline SECQ made up entirely of ISI (very low noise, very low BW) Inherent minimum SECQ Added stressors made up entirely of Gaussian noise Reference Tx baseline SECQ made up entirely of noise (very high BW, very high noise) Inherent minimum SECQ Reference Tx baseline SECQ made up entirely of ISI (very low noise, very low BW) Inherent minimum SECQ Reference Tx baseline SECQ made up entirely of noise (very high BW, very high noise) Inherent minimum SECQ 7

Why It Matters Interoperability Gaps (2a): Simulated Rx Peformance With Different Compliant SRS Ref Tx Simulation Setup Simulation in Matlab 75,000 bits run through PAM4 system model Grey coded PRBS31Q Data rate: 53 Gbd PAM4 Oversampling 16/UI Waterfall curves generated for three different transmitters into the same receiver. Receiver details In all cases: Bandwidth: 26 GHz IRN: 15 pa/rt(hz) Responsivity: 0.5 A/W Receiver 1 has equalizer with 20-tap FFE plus 2-tap DFE Receiver 2 has equalizer with 5-tap FFE 8

Why It Matters Interoperability Gaps (2b): Simulated Rx Peformance With Different Compliant SRS Ref Tx Simulation Setup: Transmitter Characteristics Ideal Tx (high bandwidth, high SNR) SECQ not calculated, but probably ~0.5 db ISI-dominated SECQ Tx (high SNR, low bandwidth) Tx SNR: 50 db Tx BW: 22 GHz TDECQ: 3 db Noise-dominated SECQ Tx (low SNR, high bandwidth) Tx SNR: ~22.5 db Tx BW: ~40 GHz TDECQ: 3 db Both compliant SRS conformance signals 9

Why It Matters Interoperability Gaps (2c): Simulated Rx Peformance With Different Compliant SRS Ref Tx Receiver 1: 20-tap FFE plus 2-tap DFE Receiver 2: 5-tap FFE 10

Why It Matters Interoperability Gaps (2c): Simulated Rx Peformance With Different Compliant SRS Ref Tx Ideal TX Receiver 1: 20-tap FFE plus 2-tap DFE Receiver 2: 5-tap FFE 11

Why It Matters Interoperability Gaps (2c): Simulated Rx Peformance With Different Compliant SRS Ref Tx Noisedominated SECQ (SECQ = 3 db) Receiver 1: 20-tap FFE plus 2-tap DFE Receiver 2: 5-tap FFE 12

Why It Matters Interoperability Gaps (2c): Simulated Rx Peformance With Different Compliant SRS Ref Tx ISI-dominated SECQ (SECQ = 3 db) Receiver 1: 20-tap FFE plus 2-tap DFE Receiver 2: 5-tap FFE 13

Why It Matters Interoperability Gaps (2c): Simulated Rx Peformance With Different Compliant SRS Ref Tx 0.3 db Receiver 1: 20-tap FFE plus 2-tap DFE 0.3 db difference in sensitivity when tested with a transmitter with ISI-dominated SECQ case and one with noise-dominated SECQ 14

Why It Matters Interoperability Gaps (2c): Simulated Rx Peformance With Different Compliant SRS Ref Tx 1.4 db Receiver 2: 5-tap FFE 1.4 db difference in sensitivity when tested with a transmitter with ISI-dominated SECQ case and one with noise-dominated SECQ 15

Why It Matters Interoperability Gaps (3): What Does This Mean? These simulation results simply mean that all things being equal, a receiver with less equalization will tend to perform worse in the presence of a lower bandwidth transmitter Both receivers perform about equally poorly in the face of lots of noise, as they are not designed to handle noise (that s the FEC s job) If a receiver with less equalization is tested with a reference SRS conformance signal with more noise and higher bandwidth and passes, there is the strong likelihood that when presented with a real transmitter in the field (compliant and with the same TDECQ as the SRS reference Tx, but with lower bandwidth), at the margins that transmitter and receiver pair will not interoperate Even though both receiver and transmitter passed spec according to the standard 16

Our Proposed Change to Address These Gaps Bound the baseline reference Tx SECQ before stressors are added, to avoid uncontrolled SECQ composition. We propose this value be 1 db. Add language defining that a receiver has to be compliant with both a reference Tx including Stressors added to the baseline Tx SECQ up to the SECQ limit comprised of all Gaussian noise Stressors added to the baseline Tx SECQ up to the SECQ limit comprised of all ISI/BW Note that this does not mean that multiple tests need to be run in production can be qualified by design and/or tested in worst-case condition only for a given receiver design Why are we proposing this specific change? This seemed to be the least impactful change to the draft that still ensures interoperability, vs. other options which would also ensure interoperability like bounding the Tx BW and/or SNR (note that in this case the SRS test would still need to be changed to match the worst-case Tx under the new spec) However, if commercial receivers cannot meet SRS in the ISI-dominated-SECQ case, then need to consider bounding TX bandwidth to ensure interop Completely constraining the baseline reference Tx SECQ makeup likely unrealistic 17

Next Steps We are running testing in the lab now to complement the simulation results shown here We welcome other efforts to reproduce our analysis either in the lab or in simulations We believe our simulation is correct and matches with common sense and intuition, and invite support for our proposed remedy 18

Other Implications and Anticipated Questions Doesn t this imply that we would have to propose a change to the Tx specification as well? Not necessarily. Either the Rx compliance criteria has to be adjusted to ensure that it can meet spec with all possible compliant transmitters (as proposed here), or the Tx compliance criteria has to be adjusted to ensure that it can meet spec with all possible compliant receivers Why the all noise case as the other extreme? This is the other Tx extreme also allowed by the draft spec, and will result in the smallest amount of ISI in the test stressor. If the all noise case proves to be the easier of the two, it can be qualified by design and not tested on an ongoing basis Note that the mostly Gaussian noise case is an allowable transmitter condition per the standard [We also believe that the all noise case may cause issues of its own in the face of real-world Rx impairments, and definitely leaves less BER margin ] What implication would the new threshold/rlm proposal have on this change, if that proposal were to be accepted? If the threshold/rlm proposal were accepted, SECQ calculation algorithm would be aligned with any new TDECQ algorithm (including threshold adjust) If an RLM spec were added to the Tx, this spec would be required of any SRS reference Tx, before stressors were added Wouldn t this same issue be there for all PAM4 optical interfaces, including those in 802.3bs? Yes 19

Thank You 20

Backup

Additional Simulations: Impact of Rx Noise / IRN Simulated Rx Peformance IRN = 10 pa/rt(hz) ISI-dominated SECQ Noise-dominated SECQ IRN = 25 pa/rt(hz) All simulations done under same conditions as in main presentation, and with Receiver 1 EQ (20-tap FFE plus 2-tap DFE) IRN varied from 10 pa/rt(hz) (left-most two curves) 15 pa/rt(hz) 20 pa/rt(hz) 25 pa/rt(hz) (right-most two curves) While as expected Rx performance is worse with higher IRN, the difference in Rx sensitivity between noise-dominated SECQ and ISI-dominated SECQ that would indicate a possible test/interop issue is not affected significantly 22

Additional Simulations: Impact of Rx Noise / IRN Simulated Rx Peformance Ideal Tx ISI-dominated SECQ Noise-dominated SECQ All simulations done under same conditions as in main presentation, and with Receiver 1 EQ (20-tap FFE plus 2-tap DFE), IRN = 15 pa/rt(hz) as in original Rx BW varied between 25 GHz and 40 GHz, with minimal impact Note that lowering Rx BW has the mitigating/counterbalancing impact of reducing Rx noise; the opposite is true for the Tx (at constant SECQ) 23

Example: Tx SNR / Tx BW relationship @ 1.7 db SECQ All combinations meet 1.7dB SECQ 24