Electronic Pulse Counter Combination device

Similar documents
Operating instructions Electronic preset counter Type series 717

Hour Meters / Timers, electronic

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

DFT. Rotating Vane Flow Meter, Counter, Doser. for liquids l/min. Measuring accuracy: 2.5% f. s. : 16 bar; t max

Time meter electronic

Multifunction devices

Preset counters, electronic

Bedienungsanleitung KCT2-6ST-V KC-LED-96-1T-24VDC

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

48x24. Options ORDER NUMBER OF TYPE PFL B

02/11/2015

Preset counters, electronic

Operating Instructions

Pulse Counters, electronic

DFT. Compact Paddle Flow Sensor

Single Axis Position Controller

Operating Instructions

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Multifunction Digital Timer

Preset counters, electronic

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Electrical connection

Electrical connection

CODIX 560. Elektronischer Vorwahlzähler mit zwei Vorwahlen. Electronic Preset Counter With two presets

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Pulse Counters, electromechanical

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Solution Selection Guide

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Eaton Durant. Counters, process instruments and hour meters.

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell


Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

multi-function meters

263 Series LED Bargraph Indicator and Controllers

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Standard signal metering in wall-mounting case

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

Flexible Counter Series in DIN size 24 x 48 mm

Process Transmitter RMA 422

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: IP Rating: Cable: Connector:

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

SAUTER flexotron RDT405 Manual

Linear encoders without bearings incremental System for linear motion feedback

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181

Manual. Analog (U/I) Sendix M3661 / M3681. Sendix M3661R. Sendix M5861. Absolute multiturn encoder. Order code: 8.M36X1.XXXX.XX12

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

TimeView Display. Operating Manual

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

Operating Instructions

Absolute Encoders Multiturn

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Data Sheet GU-LCT-RY-V1-10 GU-LCT-RY-V1-11

SCALE & WEIGHT DISPLAYS

Electrical connection

FRQM-2 Frequency Counter & RF Multimeter

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

SPECTRO Series SPECTRO-3-20-COF. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9)

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

Sensor technologies Proximity sensors Series ST4. Brochure

Amplifier for fiber optics. Dimensioned drawing

Electrical connection

Flexible Counter Series in DIN size 24 x 48 mm

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA)

G 400 CURRENT GENERATOR. programmable, ± points. User handbook Valid for instruments with version 01.xx

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

SPECTRO Series SPECTRO-3-30-UV. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9-10)

User Manual M1. Direct current / Direct voltage signals 0-20 ma, 4-20 ma, 0-10 VDC. Technical features:

SERIES 400 SERIES 620

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

CET DOUBLE COUNTER WITH TWO THRESHOLDS LBM62CD. Type: TECHNICAL FEATURES

We put you first. And keep you ahead. USES FEATURES. Bulletin SS09040 Issue/Rev. 0.2 (10/14)

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Weighing Meter. Ordering Information. Highly Functional Weighing Meter with Easy-to-read LED. Base Units

SPECTRO Series SPECTRO-3-50-FCL-JR. Design. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-FCL-JR (incl. software SPECTRO3-Scope)

SPECTRO Series SPECTRO-3-50-COF-...-CL. Design. SPECTRO-3 Series True Color Sensors. Product name:

Process transmitter RMA422

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Technical data. General specifications. Indicators/operating means

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

SPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

SPECTRO Series SPECTRO-3-50-UV-JR. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-UV-JR (incl. software SPECTRO3-Scope)

AX 345. Process Indicator with Two Analogue Inputs, Calculations and Programmable Analogue Output. Operating Instructions for Model AX 346

35058-TE. PLJ-6LED-A LED Frequency Display Module Manual

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)

Agilent 5345A Universal Counter, 500 MHz

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Transcription:

Electronic Pulse Counter Combination device measuring monitoring analysing Input: pulse counter, time meter Display: 6-digit LED Height of digits: 14/8 mm Operation with front-panel buttons Material: plastic Case: 96x48 mm and 48x24 mm Panel mounting Power : 24 V DC / 90-260 V AC Protection type: IP 65 from the front KOBOLD offices exist in the following countries: ARGENTINA, AUSTRIA, BELGIUM, BRAZIL, CANADA, CHINA, COLOMBIA, FRANCE, GREAT BRITAIN, NETHERLANDS, POLAND, SWITZERLAND, USA, VENEZUELA KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. (06192) 299-0 Fax (06192) 23398 E-mail: info.de@kobold.com Internet: www.kobold.com Model: ZEC 39

DIN case 48 x 24 Mating connectors The electronic pulse counters, KOBOLD type series ZEC, serve as combination devices for time metering and pulse counting. The input pulse can be of any shape due to an integrated Schmitt trigger. The display can be read correctly even in badly lit positions. The negligible mounting depth means that the device takes up very little space when installed in a control cabinet or a control panel. Programming and operation is carried out with two buttons on the front panel. The buttons have been designed to allow operation even when wearing gloves. The pulse counters and time meters have the following functions: Inputs: a counting input; a start/stop or gate input; a reset input (the affect can be separately programmed and inhibited on both channels in the setup); the polarity of the inputs is programmable adjustable scaling factor scale range from 0 999 999 with leading zero suppression The period on the lowest decade flashes when counting is enabled; removal of suppression of leading zeros for overflow Display: Ipulse counter: decimal point indicating only Time meter: s, min, h or h.m.s decimal point determines resolution SET button for reset (can be inhibited separately for each counter in the setup) Button 2 for toggling between pulse counter, and time meter Operation Reset counter The red reset button is pressed together with the reset input which resets the counter. Selecting the displayed value You can toggle between displaying the pulse counter and the time meter by pressing the right-hand button. If you press the button once the current function (»TOTAL«or»TIME«) is displayed for 2 seconds. If you press the righthand button a second time within this period, the function is changed over and»time«or»total«is displayed for confirmation. Setting device parameters a. Keep both buttons on the front pressed and switch on the power. b.»prog«appears on the screen. c. When the buttons are released menu title and current menu item setting appear alternating every second. When a button is pressed only the menu item setting appears. d. Press the right-hand button to advance the menu item setting by one value. To enter numerical values (e.g., for factor setting), select the decade with the left-hand button and set the value with the right-hand button. e. To select the next menu item press the right-hand button while keeping the left-hand button pressed. f. When»YES«is selected in the final menu title»endpro«you exit the programming menu and the new values are saved. Should you select»no«, the programming routine starts from the beginning, whereby the last set values are saved. These values can now be checked or altered. Areas of application Mechanical engineering Plant engineering Construction machinery Chemical industry Process visualization 40 www.kobold.com

Technical Details Max. counting frequency: 20 khz - can be damped to 30 Hz Display: 6-digit, red, 7-segment LED 8 mm high characters Scale range: 0 to 999 999 with leading zero suppression Accuracy of time meter: < 50 ppm Ambient temperature: -10 to +50 C Storage temperature: - 25 to +70 C Case: plastic Dimensions: 48 x 24 x 66 mm (w x h x d) Panel cut-out: 45 x 22 mm or 50 x 25 mm Inputs: INP A: counting input dynamic for pulse counters INP B: start/stop or gate input for time meters (depending on type of input selected RESET: dynamic reset input Switching level low: : 0 V DC to 0.2 x power Switching level high: 0.6 x power to 30 V DC Input resistance: approximately 10 kω Polarity of input signals: common programming for all inputs (NPN or PNP) Minimum pulse duration of reset input: 5 ms Pulse envelope: any (Schmitt trigger inputs) Data back-up: EEPROM 1 x 10 6 storage cycles or 10 years Noise immunity: EN 50081-2; EN 55011 class B; EN 50082-2 Power : 10-30 V DC, max. 50 ma Protection type: IP 65 Weight: approximately 50 g Scope of : ZEK-1K30 Panel clamp Front-panel frame for screw fixing Panel cut-out 45 x 22 mm Panel cut-out 50 x 25 mm Seal Pin assignment: 24 1 2 3 4 5 Order details: ZEC-1K30 Dimensions: 48 22x45 1 10-30 V DC 2 0 V (GND) 3 INP A 4 INP B 5 RESET max. 19,3 59 4 6,5 www.kobold.com 41

DIN case 96 x 48 Mating connectors The electronic pulse counters, KOBOLD type series ZEC, serve as combination devices for time metering and pulse counting. The input pulse can be of any shape due to an integrated Schmitt trigger. The display can be read correctly even in badly lit positions. The negligible mounting depth means that the device takes up very little space when installed in a control cabinet or a control panel. Programming and operation is carried out with two buttons on the front panel. The buttons have been designed to allow operation even when wearing gloves. The pulse counters and time meters have the following functions: Inputs: a counting input; a start/stop or gate input; a reset input (the affect can be separately programmed and inhibited on both channels in the setup); the polarity of the inputs is programmable eadjustable scaling factor scale range from 0 999 999 with leading zero suppression The period on the lowest decade flashes when counting is enabled; removal of suppression of leading zeros for overflow Display: Pulse counter: decimal point indicating only Time meter: s, min, h or h.m.s decimal point determines resolution SET button for reset (can be inhibited separately for each counter in the setup) Button 2 for toggling between pulse counter, and time meter Areas of application Mechanical engineering Plant engineering Construction machinery Chemical industry Process visualization Technical Details Max. counting frequency: 20 khz - can be damped to 30 Hz Display: 6-position, red, 7-segment LED 14.2 mm high characters Scale range: 0 to 999 999 with leading zero suppression Accuracy time meter: < 50 ppm Ambient temperature: -10 to +50 C Storage temperature: - 25 to +70 C Case: plastic Dimensions: 96 x 48 x 74 mm (w x h x d) Panel cut-out: 92 x 45 mm Inputs: INP A: counting input dynamic for pulse counters INP B: start/stop or gate input for time meter (depending on type of input selected) RESET: dynamic reset input Switching level low: 0-4 V DC (AC power ) 0 V DC to 0.2 x U B (DC-power U B ) Switching level high: 12-30 V DC (AC power ) 0.6 x U B to 30 V DC (DC power U B ) Input resistance for logic inputs: approximately 10 kω Polarity of input signals: common programming for all inputs (NPN or PNP) Minimum pulse duration of reset input: 5 ms Pulse envelope: any (Schmitt trigger inputs) Data back-up: EEPROM 1 x 10 6 storage cycles or 10 years Noise immunity: EN 50081-2; EN 55011 class B; EN 50082-2 Power : 90-260 V AC, max. 6 VA or 10-30 V DC, max. 50 ma Sensor : 24 V DC ±15% / 100 ma (AC version only) Protection type: IP 65 from the front Weight: approximately 150 g 42 www.kobold.com

Pin assignment Dimensions: max. 19 X1 X2 96 1 2 3 4 5 6 7 1 2 48 44,9x91,9 15,5 6,5 4 Pin assignment X2 45 +0,6 67,1 Terminal no. AC version DC version 1 2 Pin assignment X1 Terminal no. 90-260 V AC 90-260 V AC AC version GND 10-30 V DC DC version 92 +0,8 Scope of : ZEC-4K Panel clamp Seal 1 2 3 RESET RESET 4 INP B INP B 5 INP A INP A 6 GND out 7 +24 VDC out Order details (Example: ZEC-4K 00) Model ZEC-4K Description Electronic pulse counter, and time meter combination device DIN case 96 x 48 mm Power 00 =90-260 V AC 30 =10-30 V DC www.kobold.com 43

Please refer to our brochure Z4......for time measurement 44 www.kobold.com