PT9232. Heavy Industrial RS232 Communication

Similar documents
PT9232. Heavy Industrial RS232 Communication

PT9150. Heavy Industrial Incremental Encoder

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

PT8420 Cable Actuated Sensor Industrial ma 0..20mA

Draw Wire Sensor. Series HX

CEDES. Functional description CEDES 7-Segment Double Digit Indicator (CAN) Functional description 7-Segment Double Digit Indicator (CAN)

Single Point Flow Monitor SW118 SW119

Linear measuring technology

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

DRAW WIRE SENSOR. Series LX. Key-Features:

HDMI Over IP Extender Kit - 4K

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

Magnetic Sensor - Incremental EHP

Smart-Encoder : Optical Incremental

Clamps, mounting plate EN :1993, 100 g/11 ms, 100 shocks EN :1995, 20 g 10 Hz-2 khz, 10 cycles

EZ Encoder : Optical Incremental

Proportional output thumbwheels - sprung to centre

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Operator s Manual. Ultegra. Health Scale. Fairbanks Scales by Fairbanks Scales Inc. All rights reserved. Revision 5 06/07

AS-300D Series Smart Bench Scales Owner s Manual

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

MAGNETOSTICTIVE TRANSDUCER

Interface Connectors for Miniature, Portable Terminal Devices

LD OEM/LD PDS/LD PeCo

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

Linear Array with Intensity Adjustment

Sensor technologies Distance measuring sensors Series SM6. Brochure

LAUREL ELECTRONICS, INC.

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

Absolute encoders multiturn

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

EZ-LIGHT K30L Series With Independent Push Button Contact

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Wall-/Pipe-Mount Level Indicator

SCALE & WEIGHT DISPLAYS

EZ Encoder : Optical Incremental (P Series)

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface

Gurley Models LA18, LA20, LA25, High Resolution - Industrial Ruggedness

MULTITURN ABSOLUTE ENCODER EAM PROFIBUS

DRAW WIRE SENSOR. Series MH120 for mobile hydraulics applications. Key-Features:

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Introduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

For warranty service, please contact Microframe at: A technician will gladly assist you.

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet


Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

Extra long-range RFID (proximity) card reader

HDMI over IP Extender Kit with Video Wall Support p

Aegis Electronic Group

Operation/Reference Guide IRIS. Infrared/Serial Data Capture Unit. Control System Accessories

HDMI over CAT5 Extender with IR and Serial - HDBaseT Extender - 4K

Technical data. General specifications. Indicators/operating means

Type SCH94FO. Type SCH94FO. Description

CLT-353R & CLT-353L CAMERA LINK TRANSLATOR. User s Manual. Document # , Rev 0.1, 4/19/2013 preliminary

SPACESCAN SERIES SS 02

DATA SHEET Panorama Rudder Indicator, TRI-2

Absolute Rotary Encoder E6CP

Safety Light Curtains

Linear Probe Encoder Page 1 of 7. Description. Features

EZ-LIGHT K50 Modbus Series Multicolor Indicators

HDMI over CAT5 HDBaseT Extender - Power over Cable - IR - RS232-10/100 Ethernet - Ultra HD 4K ft (100m)

ISE, Inc Royalton Rd. Cleveland, OH USA Tel: (440) Fax: (440) B Long Ranger Timer

EZ-SCREEN LS. Safety Light Screen

Wind Indicator LED. Contents. Instruction for Use xx.x00, x08, xx.10

PRELIMINARY. Orbis CU. Preliminary Data Sheet!

Active FCB-EV-HD-SDI INTERFACE BOARD

4040C COMMUNICATION MODULE

Temposonics. Magnetostrictive Position Sensors. L Series (Model LH) to G-Series Linear-Position Sensor. Cross Reference A

EZ-LIGHT K90FDL Daylight Visible

Product Manual MNX10015 / REV C MODEL SB142, SB242. Dual Output Series Switch Boxes

Industriefunkuhren. Technical Manual. OEM Sync-Module FE1000 (IRIG-B) ENGLISH

Specifications. Response Time. Status Indicators. Scanning Range/Resolution. Vibration. Shock. Physical Characteristics.

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

Linear encoders without bearings incremental System for linear motion feedback

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Stevens SatComm FAQs For use with SatCommSet or Terminal Setup programs

Horn loudspeaker, Ex proof, short/long flare

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

Sensor technologies Proximity sensors Series ST4. Brochure

4830A Accelerometer simulator Instruction manual. IM4830A, Revision E1

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

MODEL ED32i TTL LINEAR ENCODER

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71.

Product Data Sheet

Micro-Machined Silicon Transducers

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Product Information. RIQ 425 Absolute Rotary Encoder with Inductive Scanning Principle for High Bearing Loads

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

L-LAS Series L-LAS-LT-50-SL-... Design. L-LAS Series Laser Line Sensors. Product name:

Transcription:

PT9232 Heavy Industrial RS232 Communication Linear Position/Velocity to 550 inches (1400 cm) luminum or Stainless Steel Enclosure Options VLS Option To Prevent FreeRelease amage IP68 NEM 6 Protection Hazardous rea Certification GENERL Full Stroke Ranges 075 to 0550 inches Electrical Interface RS232 Format HEX ccuracy ± 0.10% full stroke Repeatability ± 0.02% full stroke Resolution ± 0.003% full stroke Measuring Cable or thermoplastic Enclosure Material powderpainted or 303 Sensor plastichybrid precision potentiometer Potentiometer Cycle Life 250,000 cycles Maximum Retraction cceleration see ordering information Maximum Velocity see ordering information Weight, luminum (Stainless Steel) Enclosure 8 lbs. (16 lbs.), max. 7.9 [200 mm] 5.3 [135 mm] The PT9232 delivers position feedback via RS232 serial communication to your data acquisition or controller system. The PT9232 sends a raw 16bit count from 0000H to FFFFH. dditionally this device can be set to continuously send data or send data only when polled. 5.2 [131 mm] Input Voltage Input Current aud Rate ELECTRICL 9...22 VC 40 m 9600 (selectable to 38.4K) s the internal position sensing element is a precision potentiometer, this transducer maintains current accurate position even during power loss and does not need to be reset to a home position. Update Rate 32 msec ENVIRONMENTL Enclosure NEM 4/4X/6, IP 67/68 Operating Temperature 40 to 200 F (40 to 90 C) Vibration up to 10 g to 2000 Hz maximum Output Signal: data stream { 0000x0...... FFFFx0 } sales@sensorway.cn (0% fs.) (100% fs.) 20630 Plummer Street Chatsworth, C 91311 PT9232 1

I/O Format ata Format ata Frame Start it ataits Stop it 6 byte Hex string: 1 bit 8 bits 1 bit STX CM 0 1 2 ETX no parity bit STX = 0x02 CM = Command Code* 0 2 = ata Field* ETX = 0x03 * see below Important! ll communications to/from the transducer are in HEX! User Commands: User Command Sensor Response escription <CM> < 0 > < 1 > < 2 > Get Sensor Info 0x05 0x00 0x00 0x00 Get Serial Number 0x15 0x00 0x00 0x00 Start Continuous ata 0x25 0x00 0x00 0x00 Stop Continuous ata 0x35 0x00 0x00 0x00 Get Position ata 0x45 0x00 0x00 0x00 <CM> < 0 > < 1 > < 2 > 0x05 version (4) date (5) date (5) 0x15 serial number (3) 0x25 0x00 0x00 0x00 0x35 0x00 0x00 0x00 0x45 CMC (1) CMC (1) status (2) (1) CMC Current Measurement Count (Position) The Current Measurement Count (CMC) is the output data that indicates the present position of the measuring cable. The CMC is a 16bit value that occupies the first two bytes ( 0 and 1 ) of the data field. 0 is the MS (most significant byte) and 1 is the LS (least significant byte). The CMC starts at 0000H with the measuring cable fully retracted and continues upward to the end of the stroke range stopping at FFFFH. This holds true for all ranges. (2) Status The status byte is used as a flag to indicate the validity of the position signal that the internal electronics receives from the potentiometer. Flags are as follows: 0x00 = GREEN, 0x55 = YELLOW, 0x = RE green flag shows everything OK. yellow or red flag indicates that the sensor has either been extended beyond its range or that there is a problem with the potentiometer. (5) ate (3) Serial Number Each sensor has it s own unique serial number. This information can be retrieved by sending the sensor the Get Serial Number command. The serial number is a 3 byte value from which ranges from 0 to 9999999 (decimal). (4) Version This is a single byte value (0255 decimal) which indicates the currently installed firmware version of the sensor. This is a 2 byte value showing the date of currently installed firmware. This value ranges from 01011 12319 (decimal). Format is MMY. While the month and day are expressed as two digit numbers the year is expressed in a single digit only. Example: 08054 = ugust 5, 2004 aud Rate The baud rate can be set using switches 7 & 8 on the 8pole IP switch found on the rs232 controller board located inside the transducer. RS232 Controller oard and IP Switch Location baud rate switches IP7 IP8 baud rate 0 0 9600 1 0 19200 0 1 38400 1 1 9600 1 2 3 4 5 6 7 8 = "0" = "1" 1 2 3 4 5 6 7 8 1 2 Caution! o Not Remove SpringSide End Cover removing springside end cover could cause spring to become unseated and permanently damaged. internal dip switches & controller board to gain access to the controller board, remove four llenhead Screws and remove end cover bracket. 2 PT9232

Fig. 1 Outline rawing (18 oz. cable tension only) 0.85 [21.6] 6.15 ±0.06 [152,2 ±1,5] mounting hole detail 0.64 [16,3] 0.27 [6,9] eyelet detail Ø.191 [4,19]* Ø.375 [9,52]**.165 [4,19]** 4.80 [121,9] 1.10 ±0.08 [27,9 ±2,0] full extension full retraction 4.52 ±0.08 [114,8 ±2,0] IMENSION (INCHES) MESURING CLE RNGE Ø.031 in. Ø.034 in. Ø.047 in. Ø.062 in. 75 n/a 0.22 0.29 0.37 100 n/a 0.29 0.39 0.49 150 n/a 0.44 0.59 0.73 200 n/a 0.58 0.79 0.98 250 n/a 0.73 0.98 1.22 300 n/a 0.88 1.18 1.47 350 n/a 1.02 1.38 1.71 400 n/a 1.17 1.57 1.96 450 n/a 1.31 1.77 n/a 500 n/a 1.46 1.97 n/a 550 1.61 1.61 n/a n/a 4.90 [124,5] 0.25 [6,4] 5.16 [131,1] max. 4.75 ±0.06 [120,7 ±2,0] 7.87 [199,9] max. 5.30 [134,6] IMENSIONS RE IN INCHES [MM] tolerances are 0.03 IN. [0.5 MM] unless otherwise noted. * tolerance = +.005.001 [+.13.03] ** tolerance = +.005.005 [+.13.13] Ordering Information: Model Number: Sample Model Number: PT9232 200 L N34 26 FR M6 PT9232 order code: R C E R C E range: enclosure measuring cable: measuring cable tension: cable exit: electrical connection: 200 inches.034 nyloncoated stainless 18 oz. front (horizontal) 6pin plastic connector Full Stroke Range: R order code: 75 100 150 200 250 300 350 400 450* 500* 550* full stroke range, min: 75 in. 100 in. 150 in. 200 in. 250 in. 300 in. 350 in. 400 in. 450 in. 500 in. 550 in. * 36 oz. cable tension strongly recommended PT9232 3

Ordering Information (cont.): Enclosure Material: order code: L SS powderpainted 303 stainless Measuring Cable: order code: N34 S47 V62 S31 Ø.034inch nyloncoated Ø.047inch Ø.062inch thermoplastic Ø.031inch available in all ranges all ranges up to 500 inches all ranges up to 400 inches 550 inch range only Measuring Cable Tension: C order code: tension (30%): enclosure material: max. acceleration: max. velocity: 26 52 18 oz. 36 oz. 1 G.33 G 60 inches/sec 20 inches/sec 5 G 2 G 200 inches/sec 80 inches/sec standard housing see fig 1. dualspring housing see fig 2. Cable Exit: order code: FR UP K N front top back down Electrical Connection: E order code: M6 C25 6pin plastic connector with mating plug 25ft. instrumentation cable 24 WG, shielded IP 67, NEM 6, NEM 4X (stainless enclosure only) IP 67, NEM 6 3.0 in. [78 mm].30.39 in. [8 10 mm] cable dia. 16 WG max conductor size connector: MS3102E14S6P mating plug: MS3106E14S6S 25 ft. x 0.2in. dia. [7,5 M x 5 mm dia.] 24 WG, shielded F C E contact view pin signal 9...22 VC C Transmitted ata E Received ata F color code signal Red 9...22 VC lack White Green Transmitted ata lue Received ata rown 4 PT9232

Fig. 2 Outline rawing (36 oz. cable tension only) 5.18 ±0.06 [131,6 ±1,5] 0.85 [21,6] mounting hole detail 0.64 [16,3] eyelet detail Ø.191 [4,19]* Ø.375 [9,52]** 4.80 [121,9] 4.90 [124,5] 1.10 ±0.08 [27,9 ±2,0] full extension 0.25 [6,4] full retraction 4.52 ±0.08 [114,8 ±2,0] 5.16 [131,1] max. 0.27 [6,9].165 [4,19]** MESURING CLE RNGE Ø.031 in. Ø.034 in. Ø.047 in. Ø.062 in. 75 n/a 0.22 0.29 0.37 100 n/a 0.29 0.39 0.49 150 n/a 0.44 0.59 0.73 200 n/a 0.58 0.79 0.98 250 n/a 0.73 0.98 1.22 300 n/a 0.88 1.18 1.47 350 n/a 1.02 1.38 1.71 400 n/a 1.17 1.57 1.96 450 n/a 1.31 1.77 n/a 500 n/a 1.46 1.97 n/a 550 1.61 1.61 n/a n/a 4.75 ±0.06 [120,7 ±1,5] IMENSION (INCHES) 9.45 [240] max. IMENSIONS RE IN INCHES [MM] tolerances are 0.03 IN. [0.5 MM] unless otherwise noted. 5.30 [134,6] * tolerance = +.005.001 [+.13.03] ** tolerance = +.005.005 [+.13.13] VLS Option Free Release Protection The patented Celesco Velocity Limiting System (VLS) is an option for PT9000 Series cable extension transducers that limits cable retraction to a safe 40 to 55 inches per second for the single spring option and 40 to 80 inches per second for the higher tension dual spring option. The VLS option prevents the measuring cable from ever reaching a damaging velocity during an accidental free release. This option is ideal for mobile applications that require frequent cable disconnection and reconnection. It prevents expensive unscheduled downtime due to accidental cable mishandling or attachment failure. How To Configure Model Number for VLS Option: VLS9232 R C E F G creating VLS model number (example)... 1. select PT9232 model 2. remove PT from the model number 3. add VLS 4. completed model number! PT923201001111110 PT 923201001111110 VLS + 923201001111110 VLS923201001111110 version: 9.0 last updated: ugust 15, 2013 PT9232 5