Practicality and Performance

Similar documents
Comparison of SONY ILX511B CCD and Hamamatsu S10420 BT-CCD for VIS Spectroscopy

InSight Pro. Valuable real-time process insight

Service. Nu Instruments Service & Upgrades. ICP-MS, GD-MS, IRMS, Noble Gas.

ABB MEASUREMENT & ANALYTICS. MB3000 The most reliable FT-IR laboratory analyzer

Achieving More Efficient Data Review with OpenLAB CDS

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Noise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0

ABB MEASUREMENT & ANALYTICS. MB3600 The most reliable FT-NIR laboratory analyzer designed for QA/QC

More reliable zeta potential measurements. without dilution. Agilent Particle Analysis Solutions. Agilent 7020 ZetaProbe Zeta Potential Analyzer

Ultimate quality control. No compromise. PROCESS / QUALITY CONTROL

Reduction of Device Damage During Dry Etching of Advanced MMIC Devices Using Optical Emission Spectroscopy

CineCare services. Ensuring cinema without worries

CARESTREAM DIRECTVIEW Elite CR System

CARESTREAM DIRECTVIEW Elite CR System

User Manual OVP Raman

Evaluating Oscilloscope Mask Testing for Six Sigma Quality Standards

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

DirectView Elite CR System. Improve workflow, productivity, and patient throughput.

Coronis 5MP Mammo. The standard of care for digital mammography

IMAGING GROUP. * With dual port readout at 16MHz/port Detector shown with a C-mount nose and lens, sold separately

GCxGC Comprehensive Two-Dimensional Gas Chromatography

Speed Performance Reliability. Medicinal Chemistry Natural Products Peptides & Polymers Organic Synthesis Purifications

Standard Operating Procedure of nanoir2-s

Teaching Plasma Nanotechnologies Based on Remote Access

Advanced Test Equipment Rentals ATEC (2832)

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

111 Highland Drive Putnam, CT USA PHONE (860) FAX (860) SM32Pro SDK

CAEN Tools for Discovery

HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

WHY SWITCH TO A SYSTEM?

Electron Beam Technology

Digital High Resolution Display Technology. A New Way of Seeing Things.

X-Cite XLED1. Advanced LED Illumination for Fluorescence Microscopy. Resetting the standard for LED illumination

The software concept. Try yourself and experience how your processes are significantly simplified. You need. weqube.

OPTICAL POWER METER WITH SMART DETECTOR HEAD

GCxGC Comprehensive Two-Dimensional Gas Chromatography

MTS/T-BERD 8000 Platform

The software concept. Try yourself and experience how your processes are significantly simplified. You need. weqube.

DB-x20 Digital Billboard

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

Advanced Test Equipment Rentals ATEC (2832)

M4000 Diagnostic Test System For Power Apparatus Condition Assessment

Agilent 87075C Multiport Test Set Product Overview

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

Measurement of Microdisplays at NPL

PulseCounter Neutron & Gamma Spectrometry Software Manual

Smart Laser cinema projectors. Reduced total cost of ownership, superior image quality

T-BERD /MTS-6000, -6000A and Platforms OFI Multifunction Loss Test Module

Broadcast Television Measurements

STADIUMS THE ULTIMATE GUIDE TO STADIUM LIGHTING

Compact multichannel MEMS based spectrometer for FBG sensing

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

METROTOM. Visible Metrology.

I n d u s t r i a l M e t r o l o g y f r o m C a r l Z e i s s. METROTOM. Visible Metrology.

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

MultiQ Digital signage template system for widescreen monitors

LASER SCANNING PRODUCT GUIDE. Industrial Holographic and Conventional Laser 1D, Omnidirectional Bar Code Scanners

MILLENNIA. The Benchmark In Diode-Pumped Solid-State Lasers.

TEST ANY STANDARD QUICKLY AND COMPLETELY

Sodern recent development in the design and verification of the passive polarization scramblers for space applications

Indiana Center for Biological Microscopy. Zeiss LSM-510. Confocal Microscope

Smart Laser cinema projectors. Reduced total cost of ownership, superior image quality

HyPrecision Waterjet. Optimizing waterjet performance

Agilent E5500 Series Phase Noise Measurement Solutions Product Overview

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Compressed Air Management Systems SIGMA AIR MANAGER Pressure flexibility Switching losses Control losses next.

Barco surgical displays. High-accuracy visualization solutions for surgery and endoscopy

DISPLAY WEEK 2015 REVIEW AND METROLOGY ISSUE

Selection Criteria for X-ray Inspection Systems for BGA and CSP Solder Joint Analysis

OPERATION MANUAL INSTALLATION AND KML.F. Fiber Optic Interface Main Link. Kilomux Module. The Access Company

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

PRODUCT GUIDE CEL5500 LIGHT ENGINE. World Leader in DLP Light Exploration. A TyRex Technology Family Company

HyPrecision Waterjet. Optimizing waterjet performance

Selected Problems of Display and Projection Color Measurement

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

AVTuner PVR Quick Installation Guide

CytoFLEX Flow Cytometer Quick Start Guide

#PS168 - Analysis of Intraventricular Pressure Wave Data (LVP Analysis)

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

Innovative Rotary Encoders Deliver Durability and Precision without Tradeoffs. By: Jeff Smoot, CUI Inc

Bosch Security Systems For more information please visit

GMOS CCD Upgrade Options S. Kleinman, J. Jensen 26Sep08

Spectroscopy on Thick HgI 2 Detectors: A Comparison Between Planar and Pixelated Electrodes

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

Monitor QA Management i model

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

NIRS Vision Diagnostics

MTS/T-BERD Platforms WDMPMD Module

Avoiding False Pass or False Fail

Color measurement and calibration of professional display devices

Present. Collaborate. Impress. One-chip and three-chip DLP projectors for Corporate AV

Mechanical aspects, FEA validation and geometry optimization

Standard Operating Procedure II: EDS (Bruker Flat-Quad)

Advanced Techniques for Spurious Measurements with R&S FSW-K50 White Paper

Genomics Institute of the Novartis Research Foundation ( GNF )

Spectroscopy Module. Vescent Photonics, Inc E. 41 st Ave Denver, CO Phone: (303) Fax: (303)

SEM- EDS Instruction Manual

Agilent Understanding the Agilent 34405A DMM Operation Application Note

Intuitive Workflow by Barco. Designed for the way you work, naturally.

Transcription:

Practicality and Performance What do you need in an ICP? Consider Prism ICP In today s economy, we are challenged to do more with less. In the laboratory this translates to processing more samples with fewer analysts while spending less money on instrumentation, consumables and supplies. Often, when you compare analytical instruments, you find you must choose between performance and price; seldom will you find one that offers both. On the other hand, if you focus on your analytical needs, you may discover a product that meets your requirements at an attractive price; the Prism ICP from Teledyne Leeman Labs. Surprisingly, many laboratories have very similar needs. Most want an easy-to-use ICP with useful automation that supports a high degree of unattended operation along with easy-to-learn software. To get accurate results reported on time, labs ask for short warm-up times, fewer interferences, high sample throughput and good long-term stability. Let s face it: any lab manager understands an ICP only earns its keep during operation; durability and dependability mean better productivity with less time spent on maintenance and repair. We built Prism with these shared laboratory concerns in mind. Moreover, we designed it to be affordable without sacrificing performance. Prism has large, high quality optics housed in rigid cast aluminum for high resolution, superb sensitivity and unmatched stability. Its new solid-state array detector, the C-PAD* offers complete wavelength coverage from 175-400nm and specific line coverage in the visible region, all in a single exposure. And remember, with Prism you get indispensible Leeman Labs support built upon 25 years of experience designing and building echelle ICP spectrometers. If you are looking for sure-fire performance in ICP, discover all that Prism promises. 2

Prism ICP no-nonsense performance Speed & Sample Throughput Better Results Ease-of-Use Versatility Dependable Operation Responsive Support Get accurate results fast with Prism s simultaneous data acquisition and comprehensive wavelength coverage. Intelligent sample handling features such as fast uptake and early withdrawal keep sample transition times short. With Prism you will measure lower concentrations more accurately, choose the best analytical wavelength, dilute samples less often and pass QC requirements easily we guarantee it! Moreover, Prism offers excellent resolution (0.008nm @ 200nm), so spectral interferences are minimized. With Prism spend less time training new operators and tweaking instrument parameters. Just load the standards, QCs, and samples into the autosampler and let Prism do the rest. Get a helping hand with scheduled maintenance from Prism on-screen prompts and audio/visual support. For each wavelength use the plasma orientation (Radial, Axial or Dual View) best suited to your analytical requirements. Measure trace and major sample constituents at the same time with C-PAD s wide dynamic range (10 7, typically low ppb to percent). Run day-in and day-out without costly downtime. All Teledyne Leeman Labs products come with our standard 95% uptime guarantee *. Typical lifetimes of Leeman ICPs exceed 10 years; throughout that period you can depend on the Prism to be durable, dependable and ready to run when you are. Look to Leeman s experts in atomic spectroscopy to help you get the answers you need when you need them. *Prism high dispersion ICP Leeman Labs warrants the Prism ICP to: Provide greater than 95% up time. Operate with fewer QC failures than competing instruments. * Composite Programmable Array Detector 3

A High Performance ICP without the High Price The component most critical to the analytical performance of any ICP is the optical spectrometer. It is the design integrity and performance of the spectrometer that have the greatest impact on resolution, wavelength range, stability, immunity to stray light and detection limits. See why Prism delivers exceptional performance in all matrices. Axial, Radial or Dual View Prism is available in axial, radial or dual view configurations; each equipped with a computer controlled source mirror for automated optimization. In dual view mode, the mirror automatically selects the view and optimizes plasma viewing position in each mode. It ensures you are running at peak performance all of the time. Drift-Free Analysis Prism treats the plasma torch as an optical component. With Prism s Image Stabilized ICP, the torch is mounted directly to the polychromator and is held in place with the same integrity as any other optical component. This eliminates drift in the position of the plasma relative to the entrance slit and contributes to Prism s unmatched long-term stability. Superior stability means fewer QC failures and higher productivity. Prism Long-Term Stability Noralized Response Radial Configuration Axial/Dual View Configuration Long term stability plot showing an average precision of less than 1% RSD over 8 hours. 4

Low Stray Light for Exceptional Detection Limits in Real World Matrices Prism s Long Focal Length Spectrometer results in significantly lower stray light levels than other ICPs. This translates into lower detection limits and superior performance in real world matrices. Sample Line Mean (ppm) Std. Deviation (ppm) H 2 0 blank As193-0.007 0.0037 2% Ca As 193-0.0126 0.0109 This table shows the scattered light from a 2% calcium solution has almost no impact at primary arsenic wavelength (193.759nm). Extensive Wavelength Coverage Prism s high dispersion Echelle spectrometer and Composite, Programmable Array Detector (C-PAD) provide continuous wavelength coverage from 175-400nm while the remaining area contains active regions for commonly used visible wavelengths. The C-PAD detector has innovative in-pixel* processing and is fully programmable so it can adapt to changing sample matrices and new analytical requirements quickly. C-PAD Composite Programmable Array Detector Visible Region 400-900nm Unmatched Image Quality The resolution of a spectrometer is not only dependent on the characteristics of its grating, input slit and focal length, it is also dependent on the quality of the image (focus) at the detector surface. Prism s Echelle spectrometer uses advanced torroidal optics and a long focal length (800 mm) to ensure unmatched image quality and resolution across the focal plane. Many short focal length spectrometers suffer from significant degradation of image quality and resolution as one moves away from the centerline of the detector. The plot below shows that Prism s measured resolution is nearly identical to its theoretical resolution at all positions across the detector surface. Ultraviolet Region is Continuous from 175 to 400nm Leeman Labs Prism ICP Measured/Theoretical Resolution vs Detector Position 2.2 Measured/Theoretical (FW/HH) 2 1.8 1.6 1.4 1.2 1 0.8 0 5000 10000 15000 20000 25000 Microns across chip *In-Pixel Processing C-PAD transfers the charge between two storage locations within each pixel, so it can measure the signal at the pixel of interest without affecting the signal collected in any other pixel. C-PAD reads each pixel non-destructively, so small signals are processed at their optimum signal to noise while large signals are processed quickly to prevent saturation. This approach is fast, provides wide dynamic range and optimum signal to noise Prism s measured resolution is nearly equivalent to its theoretical resolution across the detector surface (i.e. wavelength range). for all signals. This means you will complete your analysis quickly and with fewer over-range measurements. In contrast, charge coupled devices (CCDs) move charge from the pixels of interest (analyte peak or background) to a remote amplifier to measure signal. As this transfer occurs, all pixels must be processed or the signal is lost. This approach is slow and provides inherent limitations to the dynamic range and signal to noise ratios that can be obtained. 5

software that you can use from the start! Familiar Navigator Design Instrument operating software has become much more powerful as computer memory and speed have improved. Prism s software provides intuitive navigation between applications, network readiness, access security and regulatory compliance tools. It is based on familiar navigator conventions commonly employed on the Internet with a simple tree structure and application tabs for associated functions. Frequent operations can be accessed with icons available at the top of each display. Three Application tabs appear at the bottom of the navigator panel for Method Development (Method), setting up a Sample Sequence (Sequence) and Running an Analysis (Analysis). When the user clicks on the Method tab, the navigator displays method development parameters such as Instrument Control, Element Selection, Standards, QC Checks and QC Automation. Operator access is controlled by the login procedure, shown below. Some key features of Prism s software are shown on the following pages. See how easy it is to set instrument parameters, add elements, set up automated sequences, analyze samples and report results. Applications Tab 7

Instrument Setup All instrument controls are automated and appear on a single graphical display. Achieve best performance fast with Optimize Sample Intro which displays signals with calculated detection limits while instrument parameters are adjusted. Element Selection Create methods with as many elements as you desire. Simply click the element symbol on the Periodic Table and a list of wavelengths appear. Spectral information for all standards and samples is always saved. Results Icons appear for reading standards, quality control checks, samples, automated sequences and stat (high priority) samples. View the data for each reading either numerically, as spectral thumbnails or detailed spectra for each wavelength, or as raw data with calculations applied for validation. Numeric Data Spectral Thumbnails 8

Automated Analyses Creating automated sequences is fast and simple. Import from LIMS or manually enter the names of samples to be run. If the same names are used daily, save and recall the sample list. The navigation panel (left) inserts standards and quality control checks as defined in the method automatically. When the sample list is updated, samples populate both the navigation panel (in order of anticipated analysis) and the autosampler rack map. Moving the cursor over a cup location will display its position and contents. Maintenance ICP is an analytical workhorse. Keeping it running at peak performance is essential to laboratory success. To help achieve this, Prism comes with scheduled maintenance. When maintenance is required, the Maintenance button appears with a red background. Clicking that button displays the status for all the maintenance procedures, with expired operations highlighted with a red X. When you perform maintenance, each step is detailed with audio/visual support. Diagnostics provides more than 30 test points to ensure Prism is always running at peak performance. Raw Data with Calculations 9

become a Teledyne Leeman Labs customer you ll find yourself in good company With Teledyne Leeman Labs you get more than just an ICP Teledyne Leeman Labs is committed to its customers success. After selecting Leeman for your ICP needs, you will discover an unsurpassed level of customer support. It is the product of years of experience in atomic spectroscopy and the recognition that our customers success is tied to our own. That is why we provide expert staffing for telephone support and field service.. Performance Guarantee Like you, we expect our instruments to perform reliability, that s why we offer a unique comprehensive performance guarantee. Teledyne Leeman Labs warrants the Prism ICP to: Provide greater than 95% up-time Operate with fewer QC failures than competing instruments After Sales Support Telephone Support: Instrument malfunctions never occur at opportune times and your first line of defense is knowledgeable telephone technical assistance. A technical support specialist can provide you with information on instrument operation, trouble-shooting, applications, maintenance and help you with basic repair. Most problems can be resolved over the phone. Our toll free hot line is available to you until 6:00 P.M. EST. During normal business hours, telephone assistance is provided by technicians and support chemists with specialized training in emergency repair. Every call that comes into the Customer Support Center is entered into a computerized database. After basic information has been entered, your call is routed to the appropriate specialist and tracked internally until resolved. Remote Diagnostics: To assist with complex problems, we have developed Leeman Link, remote diagnostics. Using the power of the internet, Leeman technicians dial in from a field service office and run diagnostics on your instrument. This enables us to review all the necessary information to answer questions quickly and efficiently. On Site Support: On the rare occasion of instrument failures, we will provide expert service within 48 hours. Service Agreements A variety of optional service agreements are available depending on your requirements including: Full Maintenance: A set rate comprehensive package that allows the user to budget for each instrument under the agreement. Limited Maintenance: Allows the user to budget for costs associated with replacement parts and technical support. This agreement is designed for the user who performs their own maintenance. Preventative Maintenance: Designed to keep your equipment in peak working condition and to note any items that may lead to future problems. Standards Teledyne Leeman Labs prepares and validates a line of standards and reagents for both sample digestion and analysis (Plasma-Pure). Plasma-Pure standards provide analysts with accurate, stable standards, made from high purity materials (traceable to NIST standards). With Teledyne Leeman Labs you have an analytical partner, ready to provide support for the chemistry, as well as the mechanics, of your application. You re in Good Company Are you getting the impression that we stand solidly behind our instrumentation? You re right. Our confidence comes from knowing that we haven t cut corners in the design, maintenance or testing of our products. We built our ICP spectrometer to the most exacting specifications. We built them to do the job, and to do it right. It s a reputation that we worked hard to earn and that we work harder to maintain. So what kind of companies and organizations rely on analytical instruments from Teledyne Leeman Labs? Our customers come from both the public and private sector. They are leaders in industry, government, and academia. Add to the list hundreds of cities, municipalities, and institutions of higher learning and you start to get a sense of the family of Teledyne Leeman Labs customers, and the impact that they have on our society. We continue to invest heavily in research and development and look forward to providing our customers with additional products and technology advances in the years ahead. 11

ICP Spectrometers Mercury Analyzers AA Spectrometers Inorganic Standards 6 Wentworth Drive Hudson, NH 03051 U.S.A. Tel: 603.886.8400 Fax: 603.886.9141 Email: LeemanLabsinfo@Teledyne.com www.leemanlabs.com MADE IN THE USA