R&S OSP-B200R/B200S2 Satellite System for R&S OSP User Manual

Similar documents
Product Brochure Version R&S OSP Open Switch and Control Platform Modular solution for RF switch and control tasks

Product Brochure Version R&S OSP Open Switch and Control Platform Modular solution for RF switch and control tasks

R&S BCDRIVE R&S ETC-K930 Broadcast Drive Test Manual

R&S PSL3 Industrial Controller The powerful industrial controller

R&S FPC-Z10 Teaching Kit Getting Started

R&S TS-PMB Switch Matrix Module High-density, 90-channel, full matrix relay multiplexer module

Product Brochure Version R&S ENV A Four-Line V-Network RFI voltage measurements at high currents

R&S RT-ZF5 Ethernet Probing Fixture Manual

R&S TS-ISC In-System Calibration Kit On-site calibration solution for R&S CompactTSVP

R&S RT-ZF20 Power Deskew Fixture User Manual

R&S DST200 RF Diagnostic Chamber Specifications

R&S RSC Step Attenuator Where precise signal levels count

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

R&S AMU-Z7 Analog I/Q Combiner Technical Information

R&S ZN-Z32/-Z33 Automatic In-line Calibration Modules Ensuring high accuracy with thermal vacuum testing and multiport measurements

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

R&S TS-BCAST DVB-H IP Packet Inserter Compact DVB H signal generator with integrated IP packet inserter

R&S GX460 Digital Wideband Storage Device Recording and replaying device for I/Q data with up to 40 MHz bandwidth

Programmable Power Supplies 188 W 384 W R&S HMP Series

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

R&S ZVA110 Vector Network Analyzer Specifications

Product Brochure Version R&S RSC Step Attenuator Where precise signal levels count

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

R&S GX465 Digital Wideband Storage Device Recording and replaying of I/Q data with up to 80 MHz bandwidth

DVG MPEG-2 Measurement Generator

R&S SFD DOCSIS Signal Generator Signal generator for DOCSIS 3.1 downstream and upstream

R&S ZN-Z85 Switch Matrix Specifications

Concise NFC Demo Guide using R&S Test Equipment Application Note

R&S FSV-K8 Bluetooth /EDR Measurement Application Specifications

R&S MDS-21 Absorbing Clamp Measurement of disturbance power and screening effectiveness on cables

R&S FSV-K76 TD-SCDMA BS (DL) Measurements Specifications

R&S RT-Zxx High-Voltage and Current Probes Specifications

Rohde & Schwarz Service that adds value

R&S FSW Signal and Spectrum Analyzer Resolving Security Issues When Working in Secure Areas

R&S ZN-Z154 Calibration Unit Specifications

R&S RT-ZM Modular Probe System

R&S DST200 RF Diagnostic Chamber Accurate radiated testing of wireless devices 700 MHz to 6 GHz

R&S UMS12-OEM Monitoring System Modular monitoring system with open programming interface

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

R&S SMBV-Z1 Reference Frequency Converter Specifications

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

Configuring the R&S BTC for ATSC 3.0 Application Note

R&S FS-Z60/75/90/110 Harmonic Mixers for the R&S FSP/FSU/ FSQ/FSUP/FSV

R&S FSV-K73 3G FDD UE (UL) Measurements incl. HSUPA Specifications

Fast. Accurate. USB-capable. Power sensors from Rohde & Schwarz

EX-IQ-Box Digital Signal Interface Module Specifications

Test Device Containment Module (TCM) Optimal conditions for reliable results

Fast. Accurate. USB-capable. Power sensors from Rohde & Schwarz

LabVIEW driver history for the R&S RTH Handheld Digital Oscilloscope Driver Documentation

Test Port Adapter Rohde & Schwarz Interchangeable Port Connector Application Note

E3/DS3 Fibre Extender

R&S FSV-K40 Phase Noise Measurement Application Specifications

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

R&S TS-PSM3 High-Power Switching Module Automotive DUT supply and load switching up to 30 A

V pro8 QUICK START GUIDE

FOM-9010, FOM-9011 and FOM-9012

R&S FSW-K54 EMI Measurement Application Detecting and eliminating electromagnetic

Scope of the art Scope Rider Handheld digital oscilloscope

R&S InstrumentView Release Notes Software Version 1.70

R&S RT-Zxx Standard Probes Specifications

Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02

Generator protection relay

Correlated Receiver Diversity Simulations with R&S SFU

R&S FSQ-K91/K91n/K91ac WLAN a/b/g/j/n/ac Application Firmware Specifications

R&S RT-Zxx High-Bandwidth Probes Specifications

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

HDMI Extender via Single SC Fiber Support 3D/4K2K Up To 10Km In One Single-mode Fiber

Litile34 OPERATION MANUAL

Oscilloscopes for debugging automotive Ethernet networks

Design and Use of a DTV Monitoring System consisting of DVQ(M), DVMD/DVRM and DVRG

R&S AVG050 DVB Satellite Receiver Specifications

Using R&S NRP Series Power Sensors with Android TM Handheld Devices. Application Note. Products: R&S NRP Series. R&S NRP-Zxx Series

Operating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

Product Brochure Version R&S TSML-CW Radio Network Analyzer Powerful scanner for CW applications

C8188 C8000 1/10. digital audio modular processing system. 4 Channel AES/EBU I/O. features. block diagram. 4 balanced AES inputs

R&S CEMS100 Compact EMS/EMI Test Platform Standard-compliant all-in-one solution for EMS measurements

R&S ZNrun Automated Test Software PC-based server platform for automated VNA tests

Rohde & Schwarz Service that adds value

R&S TS-PIO4 Digital Functional Test Module 32-channel programmable digital I/O module

R&S TSMx Radio Network Analyzers Powerful scanner family for mobile applications

Manual. Simrad IS80 Wind Instrument WI80. English

VLHDMIEXTFIB_2017V1.0

BY-HPE11KTA. Operating Instructions. Coaxial - LAN Converter with PoE function. Indoor Use Only. Model No. Attached Installation Guide

Original BMW Accessory. Installation Instructions.

R&S ELEKTRA EMI Test Software Easy to use software for measuring electromagnetic disturbances

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

P-2 Installing the monitor (continued) Carry out as necessary

Generating the Noise Field for Ambient Noise Rejection Tests Application Note

Model 5250 Five Channel Digital to Analog Video Converter Data Pack

Mastering Phase Noise Measurements (Part 3)

DC162 Digital Visualizer. User Manual. English - 1

R&S TS-PSM5 High-Power Switching Module Automotive DUT supply and load switching up to 50 A

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

3G-SDI Extender via Single Mode Fiber LC Simplex Connector Extends 3G-SDI Link Up To 20 Kilo Meters

FOM-1090 FOM-1090 FOM FOM-1090 w/ DB-25 Female FOM-1091 w/ DB-25 Male

Your partner in testing the Internet of Things

Accessories EXP1 - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards

Transcription:

R&S OSP-B200R/B200S2 Satellite System for R&S OSP User Manual 1178.6733.02 01 User Manual

The User Manual describes the following R&S OSP-B200R/B200S2 models and accessories: R&S OSP-B200R/B200S2 (1528.3140.02) R&S OSP-B200R/B200S2 (1528.3140.04) R&S OSP-B200S2 (1528.3134.02) R&S OSP-B200S2 (1528.3134.04) R&S OSP-B200P (1528.3205.02) R&S OSP-Z200A (1528.3170.02) R&S OSP-Z200B (1528.3170.04) R&S OSP-Z201A (1528.3186.02) R&S OSP-Z201B (1528.3186.04) R&S OSP-Z201C (1528.3186.06) R&S OSP-Z202AF (1528.3192.02) R&S OSP-Z202BF (1528.3192.04) 2017 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12 164 E-mail: info@rohde-schwarz.com Internet: http://www.rohde-schwarz.com Subject to change Data without tolerance limits is not binding. R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG. Trade names are trademarks of the owners. The following abbreviations are used throughout this manual: R&S OSP-B200R/B200S2 is abbreviated as R&S OSP-B200R/B200S2 1178673301_01_01_man_1_en 001-0002

Contents Contents 1 Documentation Overview... 5 1.1 User Manual... 5 1.2 Operating Manual of the Switch Unit... 5 1.3 Help... 5 1.4 Basic Safety Instructions... 5 1.5 R&S OSP on the Internet... 5 2 Preface... 7 3 Functional Description... 8 3.1 Satellite System... 8 3.2 Description of the R&S OSP-B200R... 8 3.3 Description of the R&S OSP-B200S2... 9 3.4 Accessories for the R&S OSP-B200 Satellite System...10 3.5 Installing R&S OSP-200R in the R&S OSP Switch Unit...11 3.6 Installing Modules in the Satellite Unit R&S OSP-B200S2...13 4 Operating the R&S OSP Satellite System... 14 4.1 R&S OSP Satellite System with Wired Link...14 4.2 R&S OSP Satellite System with Fiber-Optic Link...15 4.3 Switching on the R&S OSP Satellite System...15 5 R&S OSP Satellite System Interface... 17 5.1 Connectors of the R&S OSP-B200R Module...17 5.2 Connectors of the R&S OSP-B200S2 Satellite...17 5.3 Power Consumption...18 Figures Figure 3-1: Module R&S OSP-B200R... 8 Figure 3-2: Module R&S OSP-B200S2 Front view... 9 Figure 3-3: Module R&S OSP-B200S2 Rear view... 9 Figure 3-4: Installation of the OSP-B200R module... 11 Figure 3-5: Connection of the OSP-B151 interface... 13 Figure 3-6: Module with Slot B front panel removed.... 13 Figure 5-1: OSP-B200R Module connectors... 17 Figure 5-2: OSP-B200S Rear side connectors... 17 User Manual 1178.6733.02-01 3

Documentation Overview 1 Documentation Overview This section provides an overview of the R&S OSP-B200R/B200S2 user documentation. Unless specified otherwise, you find the documents on the R&S OSP product page at www.rohde-schwarz.com/manual/osp 1.1 User Manual Contains the description of all functions of the R&S OSP-B200R/B200S2. The user manual supports you during your first experience with the product, from installation and configuration to interfaces. It provides explanations, step-by-step procedures, figures and examples. The user manual is available for download on the Internet. 1.2 Operating Manual of the Switch Unit Contains the description of all instrument modes and functions of the R&S OSP Open Switch and Control Platform (switch unit). It is available for download on the Internet. 1.3 Help The R&S OSP-B200R/B200S2 are operated by the software R&S OSP Panel. The software-embedded help content provides quick, context-sensitive access to information for the application of the modules and switch units. The software is available at www.rohde-schwarz.com/software/osp 1.4 Basic Safety Instructions Contains safety instructions, operating conditions and further important information. The printed document is delivered with the switch unit. 1.5 R&S OSP on the Internet The website www.rohde-schwarz.com/product/osp provides: Key facts, features and options for the family of R&S OSP switch units Rohde & Schwarz contacts for information, quotes, demos and calibration services Technical documentation (operating manual for R&S OSP switch units) Brochures and Data Sheets Application Notes Drivers User Manual 1178.6733.02-01 5

Documentation Overview The current firmware version with OSA and release notes The R&S OSP Panel software with release notes Related documents and articles News and information on software updates Service Manual (only for registered users) Brochures and Data Sheets The data sheet contains the technical specifications of the R&S OSP. It also lists the options and their order numbers, and optional accessories. The brochure provides an overview of the instrument and deals with the specific characteristics. See www.rohde-schwarz.com/brochure-datasheet/osp Application Notes Application notes and application cards deal with special applications or background information on particular topics. See www.rohde-schwarz.com/application/osp Drivers Up-to-date instrument drivers are available for download at www.rohde-schwarz.com/driver/osp Release Notes and Open Source Acknowledgment (OSA) The release notes list new features, improvements and known issues of the current firmware or software version and describe the installation. The open source acknowledgment document provides verbatim license texts of the used open source software. See www.rohde-schwarz.com/firmware/osp and www.rohde-schwarz.com/software/osp Service Manual The service manual of the R&S OSP describes handling failed modules, module replacement and troubleshooting. It also contains spare part lists and mechanical drawings. The service manual is available for Rohde & Schwarz personnel, only. User Manual 1178.6733.02-01 6

Preface R&S OSP on the Internet 2 Preface This manual describes the satellite options for the R&S OSP family: R&S OSP-B200R Remote control module for one satellite OSP-B200S stock no 1528.3140.02 / 04 R&S OSP-B200S2 Satellite unit with two standard R&S OSP module slots stock no 1528.3134.02 / 04 Together with the different accessories like cables and power supply. The satellite options R&S OSP-B200R/B200S2 can be operated only in connection with one of the R&S OSP switch units R&S OSP120, R&S OSP130 or R&S OSP150. For all information related to these switch units, refer to the R&S OSP manual. User Manual 1178.6733.02-01 7

Functional Description Satellite System 3 Functional Description 3.1 Satellite System The R&S OSP satellite system is the transparent extension of two R&S OSP module slots via a cable connection or fiber-optic link. The advantages of the OSP satellite system are: Switch modules can be operated on-site. For example, high-frequency relays can be installed and controlled at the shortest possible distance. The non-conductive fiber-optic link avoids electromagnetic interference. The fiber-optic cables allow long distance connections. The fiber-optic cables can be easily fed through the shielding of anechoic chambers. 3.2 Description of the R&S OSP-B200R The option R&S OSP-B200R is the remote control (RC) interface module for operating the R&S OSP satellite unit R&S OSP-B200S. The single-slot RC module is designed to be installed in one of the base units R&S OSP120, R&S OSP130 or R&S OSP150. Figure 3-1: Remote control interface module R&S OSP-B200R Two versions of the R&S OSP-B200R module are available: Modell No. Description Characteristics Comment 1528.3140.02 Remote control (RC) Electrical interface 1528.3140.04 interface module for for one satellite unit R&S OSP-B200S2 Fibre-optic and electrical interface User Manual 1178.6733.02-01 8

Functional Description Description of the R&S OSP-B200S2 3.3 Description of the R&S OSP-B200S2 The module R&S OSP-B200S2 is the satellite unit for the R&S OSP family. It offers two slots for standard size OSP modules Figure 3-2: Front view of R&S OSP-B200S2 satellite with two modules (OSP-B128 and -B102) Figure 3-3: Rear view of R&S OSP-B200S2 satellite unit with interface connectors Two versions of the R&S OSP-B200S2 satellite unit are available: Modell No. Description Characteristics Comment 1528.3134.02 Electrical interface R&S OSP satellite unit 1528.3134.04 Fibre-optic and electrical interface DC input 28 V User Manual 1178.6733.02-01 9

Functional Description Accessories for the R&S OSP-B200 Satellite System 3.4 Accessories for the R&S OSP-B200 Satellite System For connecting the R&S OSP-B200 satellite system, the following series of accessories is available to cover all applications: Modell No. Description Description Comment 1528.3170.02 OSP-Z200A LAN-type link cable between satellite and RC module, with 15-pin Sub-D connector, length 5 m 1528.3170.04 OSP-Z200B LAN-type link cable between satellite and RC module, with 15-pin Sub-D connector, length 5 m 1528.3186.02 OSP-Z201A Fibre-optic cable, both sides SC connector, length 5 m 1528.3186.04 OSP-Z201B Fibre-optic cable, both sides SC connector, length 10 m 1528.3186.06 OSP-Z201C Fibre-optic cable, both sides SC connector, length 20 m 1528.3192.02 OSP-Z202AF Fibre-optic cable, one side SC connector, one side FSMA connector, length 5 m 1528.3192.04 OSP-Z202BF Fibre-optic cable, one side SC connector, one side FSMA connector, length 10 m 1528.3205.02 OSP-B200P Power supply for R&S OSP-B200S2, Var 04 (28 V DC, 3.75 A max.) Used for feed-through via FSMA connector. Always two cables SC- FSMA are required. Used for feedthrough via FSMA connector. Always two SC-FSMA cables are required. Use only with fiber-optic connection User Manual 1178.6733.02-01 10

Functional Description Installing R&S OSP-200R in the R&S OSP Switch Unit 3.5 Installing R&S OSP-200R in the R&S OSP Switch Unit The option R&S OSP-B200R is a one-slot module that can be installed in each of the three R&S OSP base switch unit models; i.e. R&S OSP120, R&S OSP130 or R&S OSP150. A maximum of three module busses is available in an R&S OSP base unit. Figure 3-4: R&S OSP-B200R RC interface module installed in base switch unit The R&S OSP-B200R is typically connected to two internal module busses, which are, per default, the module bus A11 and A12. Therefore, only one additional module can be operated in the R&S OSP base unit. When installing the R&S OSP-B200R into the R&S OSP base unit, you must only connect two interface cables to the R&S OSP mainboard. For the overall satellite system, make the following connections: Base unit to integrated RC interface module RC interface module satellite unit Satellite unit to integrated relay module These interface connections are shown in the the table and drawing below. Satellite Channel R&S OSP base unit to R&S OSP-B200R R&S OSP-B200R to R&S OSP-B200S2 R&S OSP-B200S2 to relay module A A11 (X2) /A12 (X4) or A13 (X13) to R&S OSP-B200R / X101 Use either a connection by Sub-D cable or a fiber-optic connection R&S OSP-B200S2 / X101 Default connection is A11 to X101 B A11 (X2) /A12 (X4) or A13 (X13) to R&S OSP-B200R / X100 Use either a connection by Sub-D cable or a fiber-optic connection R&S OSP-B200S2 / X100 Default connection is A12 to X100 User Manual 1178.6733.02-01 11

Functional Description Installing R&S OSP-200R in the R&S OSP Switch Unit User Manual 1178.6733.02-01 12

Functional Description Installing Modules in the Satellite Unit R&S OSP-B200S2 Figure 3-5: Connections of the interfaces for the R&S OSP B200R/S satellite system 3.6 Installing Modules in the Satellite Unit R&S OSP-B200S2 If the satellite unit is ordered together with R&S OSP modules, the these modules are fitted and tested already in the factory. For installing any module later on, proceed as follows. 1. Remove a blank panel (if available) from the front side of the satellite unit. 2. Find the flat ribbon cable in the open slot of the satellite unit. (In each slot, A and B, one flat ribbon cable is available.) 3. Connect the flat ribbon cable to the R&S OSP module s connector. 4. Carefully insert the module into the slot 5. Fix the module with the six screws. Figure 3-6: Satellite unit with slot B front panel removed User Manual 1178.6733.02-01 13

Operating the R&S OSP Satellite System R&S OSP Satellite System with Wired Link 4 Operating the R&S OSP Satellite System After installation of the option R&S OSP-200R in one of the R&S OSP base switch unit models R&S OSP120, R&S OSP130 or R&S OSP150, the connection to the satellite needs to be done either by Sub-D cable or by fiber-optic cable. The R&S OSP-B200R/B200S satellite system only can be used in connection with standard R&S OSP modules fitted in the satellite unit. 4.1 R&S OSP Satellite System with Wired Link For remote operation of the satellite unit across a distance of up to 10 m, use the cable R&S OSP-Z200A or R&S OSP-Z200B, as shown below: OSP-B200S Wired Link (with DC) OSP-B200R Connect the Wired Link connector only to the R&S OSP-B200R remote control interface module. Connecting it to any other connector can harm your equipment. In this configuration, the satellite unit R&S OSP-B200S is powered by the R&S OSP base unit via the cable R&S OSP-Z200A or R&S OSP-Z200B. The base unit can supply two R&S OSP modules, each with a maximum of 0.8 A (at 28 V DC). Before powering up the R&S OSP base unit, first connect the remote control interface module R&S OSP-B200R to the satellite unit R&S OSP-B200S2. User Manual 1178.6733.02-01 14

Operating the R&S OSP Satellite System R&S OSP Satellite System with Fiber-Optic Link 4.2 R&S OSP Satellite System with Fiber-Optic Link For remote operation of the satellite unit at a longer distances or inside a shielded room, use the cable R&S OSP-Z201x or R&S OSP-Z202x, as shown below: OSP-B200P AC 100V-200V OSP-B200S FOL OSP-B200R Before powering up the R&S OSP base unit, first connect the remote control interface module R&S OSP-B200R to the satellite unit R&S OSP-B200S2 and switch on the power supply OSP-B200P. Operating the satellite unit R&S OSP-B200S in this configuration always requires the power supply R&S OSP-B200P. 4.3 Switching on the R&S OSP Satellite System When the satellite system is correctly installed and connected, you can switch on the R&S OSP base unit. After booting up, the system status is shown by three LEDs. These LED s are available both in the remote interface module R&S OSP-B200R and in the satellite unit R&S OSP-B200R2. The LEDs show the following status messages: Device Power LED Link/Busy LED Overheat LED Remote interface module R&S OSP- B200R Green when power is ON Continuously yellow when link between remote interface and satellite is established. Flashing yellow during data transfer. -- Satellite unit R&S OSP-B200S2 Green when power is ON Continuously yellow when link between remote interface and satellite is established. Flashing yellow during data transfer. Orange when fan is switched on Red if overheating occurs User Manual 1178.6733.02-01 15

Operating the R&S OSP Satellite System Switching on the R&S OSP Satellite System In case of overheating, indicated by the satellite unit, the built-in modules are reset. User Manual 1178.6733.02-01 16

R&S OSP Satellite System Interface Connectors of the R&S OSP-B200R Module 5 R&S OSP Satellite System Interface 5.1 Connectors of the R&S OSP-B200R Module The following picture shows the layout of the R&S OSP-B200R interface connectors on the module s interface panel. Figure 5-1: R&S OSP-B200R module connectors Connect the Wired Link connector only to the R&S OSP-B200R remote control interface module. Connecting it to any other connector can harm your equipment. 5.2 Connectors of the R&S OSP-B200S2 Satellite The following picture shows the layout of the R&S OSP-B200S2 interface connectors on the satellite unit s rear panel. Figure 5-2: R&S OSP-B200S2 rear side connectors User Manual 1178.6733.02-01 17

R&S OSP Satellite System Interface Power Consumption Pin 1 Pin 3 Pin 2 Pin 4 GND + 28 V Figure 5-3: Pin assignment of the satellite unit s power supply DC input Connect the Wired Link connector only to the R&S OSP-B200R remote control interface module. Connecting it to any other connector can harm your equipment. 5.3 Power Consumption Both the satellite system and the modules fitted within the satellite draw power from the R&S OSP base switch units (i.e. models R&S OSP120, R&S OSP130 or R&S OSP150). However, the additional power consumption required by the satellite system is relatively low: Max. 50 ma at 28 V Max. 250 ma at 3.3 V For the power consumption data of the various modules, refer to the data sheet of the R&S OSP. User Manual 1178.6733.02-01 18