Damaged, unsecured, and broken poles

Similar documents
BEFORE THE PENNSYLVANIA PUBLIC UTILITY COMMISSION DIRECT TESTIMONY OF JAMES J. GARDLER ON BEHALF OF COMMUNICATIONS WORKERS OF AMERICA

Selecting the correct cable type for Outside Plant Application

Based on our maintenance efforts, during the second quarter of 2018, Comcast s plant was 99.9% reliable.

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98)

Aerial Cable Installation Best Practices

3M Coupling Tray FDTC-10S-COUPLINGTRAY

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

imac Intel 27" EMC 2546 isight Camera and Microphone Cable Replacement

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

3 SLiC Aerial Closure with Rubber End Seal

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

SUMITOMO RECOMMENDED PROCEDURE SRP SP-F Ribbon Indoor/Outdoor Riser Cable Preparation

3M Distribution Box (DDB)

2178-L/S Series Fiber Optic Splice Case with Gasket

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

ENGINEER S REPORT. of the SAFETY OF MAW COMMUNICATIONS FIBER OPTIC CABLE INSTALLATION

3M Better Buried Compound Compression Closure System

Instructions. Cable with Armor F CAUTION. October Rev A

Troubleshooting Guide for E-Poll Book

imac Intel 27" EMC 2639 Display Replacement

Communication Markets Division. 3M Fiber Closures. Smart design makes your job easier.

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

3M Motor Lead Inline Splice 5331, 5332, 5333 & 5334

DS1 Cross-Aisle Panel

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

*** no equipment put on roofs or buildings. Dish must be put in ground 3 feet from building to allow for mowing. ***

D1.6 Audio Cassette Special Processing Guide

K & B Flame Retardant Building Riser Closures

A449-6S 70 CENTIMETER FM YAGI ANTENNA MHz

High Voltage Cable Splicing Training

INSTALLATION INSTRUCTIONS

CASS TL-3 (Utilizing C-Shaped Post) Maintenance and Repair Manual

Troubleshooting Guide for E-Poll Book

ALTOS LITE Loose Tube, Gel-Free Cables with FastAccess Technology, Fibers

1. The contractor shall ensure that: c) Contractor or sub-contractor has at least 5 years experience

Optical Distribution Box 300 Installation Guide. Version : R0.0

Sample Test Project. District / Zonal Skill Competitions. Skill- Electrical Installation. Category: Construction and Building Technology

Your CAB is enabled for an application as follows:

Customer-Owned Outside Plant

3M Better Buried Closures

27mm ECAM Double Cable Entry Port

Troubleshooting Guide 9630 Series

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

WCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12)

Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

SIR-GM1 GM CLASS-2 BUS COMPATIBLE SIRIUS SATELLITE RADIO TUNER

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

Ordering Guide of the Fiber-Optic Splice Closure (FOSC-400)

3M Fiber Optic Closure System LL

INSTRUCTION MANUAL SUPER LASER

imac Intel 21.5" EMC 2544 Camera and Microphone Cable Replacement

3M Cold Shrink Foldback Splice Jacket Kit

Verizon Transition Update December 5, Process

SLiC Fiber Aerial Closure System

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

K Service Source. Apple High-Res Monochrome Monitor

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

TV Lift System Model CL-65 Installation Instructions

IP-LINX. Installation Guide

300 SERIES Satellite Radio & Data Products

Water blocking tape. Locator ridge HPA-0486

EAGLE RE-1 CONTROLLER For Use On MotoSAT HD Mounts

Caution. Hanging the Screen:

3M Cold Shrink Splice Kit QS-III 5416A

3M Cold Shrink Splice Kit QS-III 5514A

OCC Installation Round Messenger Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

CAB CYBEX For use with BVE personal viewing screens operated from Cybex 525 or 625 series consoles

Wired Troubleshooting Manual

QDA4-44 RF Amp/Combiner

SPARK. Swing Manual READ MANUAL FIRST. Version 1.2

VITALink Taped Splice Straight Through Crimp

3 Locating and Marking Products DOCUMENT OBSOLETE

F CAUTION. Jacketed Concentric Neutral (JCN) Cable. Concentric Neutral (CN) Cable. IEEE Std. No. 48 Class 1 Termination 15 kv Class 110 kv BIL

INSTALLATION MANUAL. ST-CVTSD520-WSD-W Smoke Detector Covert Camera. v1.2 8/11/11 1

HA15 Solid State Headphone Amp

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

GUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS (440)

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

18mm ECAM Cable Entry Port

Remote Tuner Mounting System for the MFJ-998RT

User s Manual. SmarTV

FIBER OPTIC CABLE PULLING

ASSEMBLY AND INSTALLATION 3 ELEMENT 6 METER BEAM

KODAK Video Monitor CFH-V10

APSPB PUSH BUTTON ZERO Installation Manual

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

K Service Source. Apple High-Res Monochrome Monitor

NZQA unit standard version 3 Page 1 of 7. Demonstrate knowledge of telecommunications cable systems

QCA9-33 Active Combiner

T850 Day & Night Security Camera

Building + Mounting Learn Rooftop Basics

TV55. Owner s Manual. Indoor/Outdoor Amplified TV Antenna

VersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA

ASSEMBLY INSTRUCTIONS

TFT-150R-G. Tape Shield Cable (page 2) Suggested Installation Equipment (not supplied with kit) Wire Shield Cable (page 7)

SECTION Q -- EQUIPMENT REMOVAL AND CABLE MINING

Transcription:

Evidence of Verizon Neglect of Infrastructure. Submitted to Maryland Public Service Commission by the Communications Workers of America, November 16, 2015 (Case No. 9133 and Case No. 9114.) Damaged, unsecured, and broken poles 1. The picture below from rear of 2405 West Cold Spring Lane, Baltimore City, MD shows a double-wood. An old utility pole has been cut with Verizon s terminal still attached to it. The old pole does not appear secured to the new pole. It is left dangling causing a hazard to the public. It is a worker and public safety concern. 2. The picture below from 1521 Hunter Mill Road, Parkton in Baltimore County, MD shows a utility pole with no tension in the guy wires. Without the tension in the guy wires, there is a higher risk of the pole falling over. This is a public safety concern. 1

3. The picture below from Frt.1214 Wiseburg Road, Parkton in Baltimore County, MD shows a triple-wood, where the utility company has replaced a pole but Verizon has not yet transferred over its six cables. 4. The picture below from rear of 2455 West Cold Spring Lane in Baltimore City, MD shows a double-wood. The newer pole was installed in February 2012. The base of the old pole is wrapped in fiberglass to serve as a pole cast, and there is a rod driven into it to hold it up. 2

Damaged and Exposed Cable and Splice Terminals 5. The picture below from Manor, Baltimore County, MD shows a deteriorated cable covered by deteriorated black plastic wrap. Wires are exposed to the elements and an animal has nested inside the wrap. Weather and wildlife affect service. On the right side of the picture, drop wires are bypassing the defective cable. Drop wires are not meant for outdoor use, deteriorate more quickly than cable, and their use will affect service. 6. The picture below from Frt. 1525 Walker Avenue, Parkton in Baltimore County, MD shows the remnants of a deteriorated black plastic wrap and exposed wires. There is no hard case to protect the exposed wires and the temporary plastic wrap did not last. Exposed wires are susceptible to damage from weather and animals. Damaged wires cause service outages. The discolored wires indicate long exposure to weather. 3

7. The picture below from rear 3506 Northway Drive, Baltimore, in Baltimore County, MD shows a deteriorated plastic covering. The exposed wires underneath the plastic are discolored indicating the condition of this splice has existed for some time like this. These wires are susceptible to damage from weather and animals and allows for animal infestation. Damaged wires affect service. 8. The picture below from Pole 22 on Thompson Creek Road, Stevensville in Queen Anne s County, MD shows a terminal box pulled off the pole, wrapped shut and tied to the pole with wire. The cable feeding the terminal is not long enough to fasten the serving terminal to the pole vertically. Working on the terminal presents a safety challenge for the technician because it would require untying the wire, which would then cause the terminal s sharp-edged front lid to fall on the technician. This is both a worker safety and service affecting concern because the wire will deteriorate and the terminal will swing loose on the pole or open and expose the wires. 4

9. The picture below from Pole 4 on North Lake Drive, Stevensville in Queen Anne s County, MD shows deteriorated plastic wrapping that has uncovered the side of the splice closure it was intended to protect. The cable has been pulled out of the terminal exposing the wires to the elements, which causes deteriorating wires and service outages. 10. The picture below shows Pedestal 12 on Romancoke Road, Stevensville in Queen Anne s County, MD with a lid cover that will not close. Without a cover, the pedestal s internal wiring is exposed to animals and weather, both of which can affect service. A technician has attempted to protect the internal wiring that provides customers service by placing a waffle case over the wiring. Waffle cases are used in a manhole or on aerial cables, not pedestals. The overgrowth on the lid and pedestal suggests the condition of this pedestal has existed and gone without needed repair for some time. This is a public safety hazard. 5

11. The picture below from 13108 Manor Road, Manor in Baltimore County, MD shows a missing splicer terminal case. The wires are exposed to animals and the elements, causing service outages. Discolored wires indicated long exposure to weather. 12. The picture below from Pole 16 Dominion Road, Chester in Queen Anne s County, MD (north of Ocean City) shows multiple service affecting problems. First there is a splice terminal that should be secured to the strand. The end collar or stub is pulled out of the splice case. It is upside-down and the temporary, black plastic wrapping (yellow arrow) on the right side allows it collect water. Water deteriorates the wires and affects service. 6

13. The picture below from Pole 31 on Cox Neck Road, Chester, in Queen Anne s County, MD (north of Ocean City) is a closure from the 1980 s before the Company replaced these soft closures with hard plastic cases. It shows wires exposed to the elements. Exposed wires will short out customer phone lines. Water, insects, and animals get into the closure, damaging wires and affecting service. 14. The picture below from Pole 2, North Lake Drive, Stevensville in Queen Anne s County, MD shows plastic wrapped around the cable between two splice terminals which each house 100-200 customers lines. Water runs into the plastic and forms the belly that pulls on the wrapping. The covering collects water, deteriorating the wires and affecting service. 7

15. The picture below from 1700 Ingram Road, Baltimore in Baltimore County, MD shows a splice case with deteriorated black plastic covering. Deteriorated covering leaves wires susceptible to damage from weather and animals. Damaged wires cause repeated customer service outages. 16. The picture below of Pole 10 on Elm Street, Stevensville in Queen Anne s County, MD shows a terminal taped shut and taped to a pole. The terminal should be secured to the pole. Likely this pole had been replaced and contractors taped the box to the pole instead of properly reattaching it and the wires below the box. Working on the terminal would require cutting the tape, which would cause the sharp-edged case front to fall outward on the technician. This is both a worker safety concern and service quality affecting because the tape will eventually deteriorate and allow the terminal to swing loose on the pole or swing open. 8

17. The picture below from Ped 2, Beach Drive, Stevensville in Queen Anne s County, MD shows a splice terminal that has been wrapped with a temporary plastic covering. There are exposed wires underneath the covering. The covering collects water, deteriorating the wires and affecting service. 18. The picture below from 1105 Elbank Avenue, Baltimore City, MD shows a terminal that is not attached to the pole. It appears to be wrapped and tied to the pole with wires and cable ties. The terminal should be vertical and secured to the pole. Working on the terminal would require untying the wire and cutting the cable ties which would cause the terminal to flip and potentially hit the technician. This is a worker safety concern because the wire will deteriorate and the terminal will swing or open. 9

19. The picture below from 732 Glenwood Avenue, Baltimore City, MD shows a terminal with deteriorated black plastic covering. Deteriorated covering leaves wires susceptible to damage from weather and animals. It can also create an unsafe environment by allowing bees to nest in the wires. Damaged wires that are exposed to the elements are more likely to affect service. 20. The picture below from Baltimore City, MD shows a white plastic wrap over a defective cable. The clear plastic is the shipping material the SLIC enclosure comes in. This is an example of a technician not having the proper material available to them. There are exposed wires underneath the covering. The covering collects water, which deteriorates the wires and affects service. 10

By-passing Damaged Cable 21. The picture below from 13001 Long Green Pike, Manor in Baltimore County, MD shows a black plastic wrap covering a defective cable and multiple wires bypassing a defective 200-pair cable. The cable is bypassed using drop wires, which are not meant for outdoor use. They will deteriorate faster than the cable. As they deteriorate, there will be service issues. 22. The picture below from Pole 53 Wiseburg Road, Parkton in Baltimore County, MD shows multiple wires bypassing a defective cable. The cable is bypassed using drop wires, which are not meant for outdoor use. They will deteriorate faster than the cable. As they deteriorate, there will be service issues. 11