Enhancing Patient Safety. New global design standards for enteral device tubing connectors GROUP 3. British English

Similar documents
Enhancing Patient Safety. New global design standards for enteral device tubing connectors GROUP 2. American English

Presenters. Let s Talk about Tubes 4/17/2014. Leanne Saxton, RD Employed in acute care; previously in home health care

Agilent 87075C Multiport Test Set Product Overview

The use of Time Code within a Broadcast Facility

F I L M S T U D I O G R O U P

June/July 2016 Med Tips

REQUEST FOR PROPOSALS AND TERMS OF REFERENCE

Distribution Unit. User Guide

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

The. Roadmap ENABLING CHANGE

Plessey PS EPIC 6:2 Multiplex box Instruction Manual.

Model 1606 Super. User Manual

Preparing for a Transition from an FI/Carrier to a Medicare Administrative Contractor (MAC) Provider Types Affected

ASP-FIBRS1 User Manual

MS2540 Current Loop Receiver with RS485 Communication

Coverage where you need it, made easy!

NEMA XR 25 COMPUTED TOMOGRAPHY DOSE CHECK

HSME-C400. Data Sheet. Side-Fire Mono-Color Surface-Mount ChipLED. Features. Description. Applications

VGA Video Extender ST1214T ST1218T ST121EXT / ST121EXTGB / ST121EXTEU ST121R / ST121RGB / ST121REU

SignalCorrect Software and TCS70902 Calibration Source Option SC SignalCorrect software

Digital Screen Network

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

SediVue Dx * Urine Sediment Analyzer User Guide

GE Digital Solutions. PACE1000 High Precision Pressure Indicator Series. Spares Catalogue 120M3420 ALL USERS

Impact on Providers. Page 1 of 11

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

TS2.8 Sub OWNER S MANUAL

The Internet of Things (IoT) has many potential implications for the manufacturing sector. Revolution in the making

Pulse Biomedical QRS-Card Tango M2 Interface Notes

HDMI over CAT5 HDBaseT Extender - RS232 - IR - Ultra HD 4K ft (100m)

ISO Digital Forensics- Video Analysis

Product Brochure Version R&S ENV A Four-Line V-Network RFI voltage measurements at high currents

ThinkRF D GHz RF Downconverter

TV Connector user guide

Request for Proposals

M24SR-DISCOVERY. Discovery kit for the M24SR series Dynamic NFC/RFID tag. Features

User Guide. HDMI Fiber Optic Extender. DVI-7350a

SmartCrystal Cinema Neo

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

S MiX 2M2S UF. S MiX 2M2S F

Manual XMReality Smart Glasses RG15

TV Adapter 2 INSTALLATION GUIDE INSTRUCTIONS FOR USE

Spine Cable System. Implants and instruments for use when stabilizing and reconstructing spinal structures.

FAQ s DTT 1. What is DTT? 2. What is the difference between terrestrial television and satellite television?

Christie Boxer Series

ADB 62.5 An old digital protocol developed by ADB. Still in use although not on new products. Uses a 5 pin XLR so don t confuse it with DMX512.

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona USA

HDMI over CAT5 Extender with IR and Serial - HDBaseT Extender - 4K

Syringe 200 ml For Contrast Media Nubenco Enterprises I

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

ACUBRITE 23 SS. Manual. Stainless Steel Chassis 23" LCD Display. Content

HE INSTRUCTION MANUAL

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Complete the experience. Speakers Class D amplifiers Audio/video processor. (roar)

True comfort and flexibility with the power of 3T.

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

2 x 58 W high frequency ballast for T8 fluorescent tubes based on L6562A, L6569, and STL11NM60N in PowerFlat HV package


CASE STUDY. Smart Motorways Project. Temporary CCTV Monitoring Systems for England s Motorway network.

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

Cardioline Cube Stress Tango M2 Interface Notes

Stratos Duo RGB. User Manual. Order code: EQLED371

Durata. Defibrillation Lead

PT-C-HDADE. User Manual. HDMI Audio De-Embedder 4K (60Hz 4:4:4) Model PT-C-HDADE. Designed in Germany

easyspiral The world's fastest Spiral plater

AEQ TH-03 Digital Hybrid of 1 (TH-03.1) or 2 lines (TH-03.2) with Frequency Extender

HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

S M A R T U LT R A S O U N D

OPERATION NOTES FOR PSIDEX AUDIO PGP-1A PRE-AMPLIFIER DESCRIPTION INSTALLATION

R&S ZN-Z32/-Z33 Automatic In-line Calibration Modules Ensuring high accuracy with thermal vacuum testing and multiport measurements

Defining DTTB network specifications and ensuring Quality of Service

Global Paper Packaging & Paperboard Packaging Market Outlook ( )

US FDA Enforcement in 2018 Reading the Tea Leaves

Introducing Ultra Short LC : Fiber Optic Cable Assemblies

TGL2210-SM_EVB GHz 100 Watt VPIN Limiter. Product Overview. Key Features. Applications. Functional Block Diagram. Ordering Information

Myrius TM mechanisms - white

TGL2209 SM 8 12 GHz 50 Watt VPIN Limiter

SmartCrystal Cinema Neo

Ofcom's proposed guidance on regional production and regional programming

Long Range Ethernet Extender

Broadband Changes Everything

.Power Distribution Center. PD-1. Instruction Manual

easyspiral Dilute The world's fi rst automatic diluter & plater A revolution in serial dilutions!

*Prefer. 600 MHz 4K ULTRA. 60Hz, 4:4:4. over one SC-Terminated Fiber-Optic Cable EXT-DP-4K600-1SC. User Manual. Release A1

Deciding When to Submit a 510(k) for a Change to an Existing Device Draft Guidance for Industry and Food and Drug Administration Staff

Australian and New Zealand Energy Performance and Marking Requirements for External Power Supplies

VGA over Cat5 Video Extender (UTPE Series)


Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes

SAFETY WARNINGS AND GUIDELINES INTRODUCTION CUSTOMER SERVICE

SignalOn Series. L-Band Splitter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

VGA AUDIO AUDIO MATRIX SWITCHER S MANUAL

VideoSplitter HDMI 4K PT

700 MHz clearance programme timescale review. Review of progress, risks and readiness

The Importance of Connectivity in the IoT Roadmap End-User Sentiment Towards IoT Connectivity. An IDC InfoBrief, Sponsored by February 2018

KD-VP800 RGBHV-to-Component Digital Video Scaler & Video Adapter

HD Digital MPEG2 Encoder / QAM Modulator Get Going Guide

Scopus in Research Work

Transcription:

Enhancing Patient Safety New global design standards for enteral device tubing connectors British English GROUP 3

Reducing the Risk of Tubing Misconnections A new international design standard for medical device tubing connectors is anticipated to be released in 2015 as part of a phased initiative called Stay Connected. Stay Connected is led by an international group of clinicians, manufacturers, and regulators, which together developed ISO 80369-1. This standard establishes requirements for smallbore connectors for liquids and gases, making it difficult, if not impossible, for unrelated delivery systems to be connected. The introduction of this standard will mark a new milestone in the global effort to improve patient safety, starting with enteral feeding systems. Prior to the ISO initiative, as an interim step toward enhancing patient safety, manufacturers supporting the UK and Republic of Ireland met customer demand for a safer connector with a reverse Luer system. However, with the availability of adapters to change a reverse Luer back into a standard Luer and with increasing patient mobility, a single global solution is required to ensure patient safety and prevent possible misconnection or no connection of enteral tubes, sets, and syringes. The new ISO standard connector system called ENFit will replace the reverse Luer connector systems in the UK, to ensure one global enteral connector. The ENFit connector will look very similar to the existing connector, however the bore size is slightly larger.

The new design standard impacts the entire enteral feeding system NUTRITION END ENPLUS OR 40mm SCREWCAP CONNECTOR (Proposed ISO 18250) PATIENT-ACCESS END Syringe with ENFit connector SYRINGE (CURRENT) SYRINGE (FINAL) Syringes to administer medicine, flush, hydrate, or bolus feed through enteral tubes will now require a precise enteral-specific fitment. New ENFit female connector Transition Connector to reverse Luer FEEDING TUBE (CURRENT) TRANSITION SET (TEMPORARY) Allows fitment to current port until new ENFit enteral feeding tubes are available. Estimated conversion and phase out of transition connector is one year. FEEDING TUBE (FINAL) Changing from the reverse Luer connector to the new ENFit connector, which will look similar to the existing connector, however the bore is slightly larger.

GEDSA LAUNCH GROUPS Timeline for New ENFit Connectors GROUP 1 US, Canada, Puerto Rico GROUP 2 EMEA + ANZ Europe, Middle East, Africa, Australia, and New Zealand The UK and Ireland will transition separately from the rest of Europe. GROUP 3 United Kingdom, Ireland 2011 Completion and adoption of foundational standard ISO 80369-1 that sets general requirements for safer connectors. 2012 NUTRITION END CONNECTOR Proposed ISO 18250 standard to include ENPlus connector and existing 40mm Screwcap. 2013 Formation of the Global Enteral Device Supplier Association (GEDSA) to help introduce new standard connectors. 2014 The Stay Connected initiative for using safer connectors is launched and the Awareness phase of the enteral connector transition begins. 2015 Sept. PATIENT-ACCESS END TRANSITION SET Transition sets available. Administration sets will have the new ENFit female connector and the limited-use ENFit Transition Connector to facilitate compatibility between the new ENFit system and the existing port. 2016 March PATIENT-ACCESS END FEEDING TUBE New enteral feeding tubes with ENFit connector available. The final step of the transition will be the proliferation of the new ENFit male connector port. PATIENT-ACCESS END SYRINGE Enteral-specific syringes available. The new connector requires the new ENFit syringe that can be used for medicine, flush, and bolus feeding. The reverse Luer-tipped syringe will not fit the new ENFit male connector tube. All dates are projected and subject to change due to timing of product-specific regulatory review and supplier discretion. Consult your supplier representative for product-specific availability, indications, contraindications, precautions, and warnings. Group 3 v.2 2014 This transition to safer connectors is an international initiative. For the most current information, visit www.stayconnected.org.

Stay Connected with GEDSA: Aware, Prepare, Adopt The Global Enteral Device Supplier Association (GEDSA) is a nonprofit trade association formed to help introduce international standards for healthcare tubing connectors. Comprised of manufacturers, distributors, and suppliers of enteral nutrition devices worldwide, GEDSA facilitates information flow about the three-phase initiative, which is designed to increase patient safety and optimal delivery of enteral feeding by reducing the risk of tubing misconnections. Aware Prepare Adopt Inform: Clinicians Administrators Supply chain Risk management Quality and safety personnel Healthcare technology management Other support staff Assess and adapt existing systems, processes, and protocols Work with supplier representatives Train clinicians and inventory management staff Meet milestone transition dates Reinforce long-term benefits over short-term inconvenience Sign Up to Stay Connected To sign up for email updates with the latest information and tools to help you with this transition, visit www.stayconnected.org 2014