SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Theatre Technical Specifications

INFORMATION FOR VISITING COMPANIES

Technical Specification for the Alley Theatre, Strabane

Technical Specifications Updated 01/10/2017. Stage

Technical Information

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Technical Specifications

Theatre Technical Specifications

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

2017 TECHNICAL SPECIFICATIONS

Technical Specifications Nov 2016

Technical Specification

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Matt Dann Cultural Centre

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Stage. Get In & Parking

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Technical Specifications. Taylor Little Theater

UNIVERSITY CONCERT HALL. Technical Specification

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Technical Specification. Updated: April 2016

Technical Director of Production Andrew Quick Ext 252

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

CENTRE FOR PERFORMING ARTS

The Lights Technical Guide June 2017

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Rhodes Arts Complex Bishops Stortford. Technical Specifications

Technical Specifications

Technical Specification Ardhowen Theatre

Dr JOHN GALLAGHER CONCERT CHAMBER

Darlington Hippodrome Technical Specification

TECHNICAL SPECIFICATIONS

Concert Hall Technical Specifications

CHELSEA THEATRE. Technical Specifications

TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE

ISLAND HALL TECHNICAL INFORMATION

Main House Technical Specifications

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Technical specifications Main theatre. Sound

Technical Information

Main Stage Technical Specs - Hall #2

Technical requirements & conditions for hirers

Concert Hall Technical Specifications

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Access to back stage is off Fletcher St on the eastern side of the building

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

332 fixed seats (max capacity) with reserved space for disable access

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

Technical Specification (Studio Theatre)

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Technical Services and Specification

Tickets will be sold through our ABC account and all tickets are scannable on entry.

Marjorie S. Deane Little Theater

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

TECHNICAL SPECIFICATION

JERWOOD VANBRUGH THEATRE

Technical Specifications

Technical Specification 2016

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

John Leslie Theatre. Technical Specifications. Updated July 2018

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

Stage. Please see Tron, Main House Lighting Rig Info.pdf for more information. Get In & Parking

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Information for Incoming Companies

Technical Specification (Studio Theatre)

PSYCHIC SALLY PRODUCTION RIDER & FOH REQUESTS (UPDATED 2016)

THE STREET THEATRE. Technical Specifications

Latrobe Performing Arts Centre

Pleasance London Main House Visiting Company Information Pack May 2017

Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

Lighthouse Theatre Technical Specification

Dugdale Centre Technical Specification

Patriots Theater at the War Memorial Technical Data

Backstage Accommodation (Ground Floor Mezzanine Level 1 Floor above Loading Bay)

GORDON CRAIG THEATRE TECHNICAL SPECIFICATION ISSUE 1 10/10/16

RPAC REDLANDS PERFORMING ARTS CENTRE

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

The Lantern Technical Information

Technical Specifications

Transcription:

1 Summary Cornerstone arts centre consists of the main house which is 217 seat end on format with raked seating. An extra row (AA) of flat floor seating can be added giving a capacity of 234. The stage is a proscenium arch format with black box masking. The seating is fully retractable bleacher style seating. Backstage we have a large scenery dock and small workshop. There is a large greenroom along with two large dressing rooms. The following information lists most FAQ s along with the relevant technical information. Please confirm your technical requirements before you visit as Cornerstone is a busy venue and equipment and specifications are subject to change and cannot be guaranteed. In the first instance please contact the Technical Manager grover.hall@southoxon.gov.uk Access and Parking We have a small service yard that can accommodate approximately eight cars. It is also big enough to accommodate a 1 x 40ft trailer with tractor unit. The correct postcode for our service yard is OX11 8RJ. Access to the yard can be given by phoning the Duty Manager mobile (Number upon application). Parking for all non-essential crew is via public car parks which are around two minutes walk away. Load-in is situated in the service yard and is via roller shutter doors. (3560mm width by 3900mm height). Auditorium Seated capacity is 234 (with AA) or up to 250 with seating retracted and standing space (auditorium side). The stage is a proscenium arch format with black box masking. The Auditorium has a full air conditioning and heating system. Backstage Facilities On the ground floor off to stage right we have a very large green room with sofas, tea/coffee making, microwave, fridge and television. You are also welcome to use the washing machine and dryer along with our iron. The green room has its own accessible toilet and there is another in the corridor adjacent to the green room. Off to stage right there are two large dressing rooms. Dressing room one has mirrored seating for seven along with a small sofa bed, accessible toilet and shower facilities. Dressing room two consists of mirrored seating for six along with accessible toilet and shower facilities. Stage Management We do not have a permanent Prompt Corner, but do have an LCD screen (with FOH camera feed) along with a stage management console (please request in advance) that has ROH calling along with cue light calling and comms master station. There is also access to the electronic FOH tab control system.

2 Stage Dimensions (Meters) Depth from back wall to Setting line. 6.6 meters Front width with pros closed 8.5 meters wide Front width with pros open 11.8 meters wide On Stage width wall to wall 12.8 meters wide Grid height with bars flown out: 7.4 meters Grid height with bars at show level: variable Flying There are 11 Motorised bars (1-11) over the stage, and 1 manual bar (which is only to be used for the proscenium border). There are a further 5 motorised bars (12-16) over the audience seating. Each bar has a SWL of 250kg; this is not to be exceeded under any circumstances. There are no fixed flying points for flown PA or truss. We may be able to offer flying points off structural girders with advance notice and risk assessments. House tabs are operated independently of any of the fly-bars, and are motorised. We do have half tabs at approximately mid stage, these would need advance notice if they are to be moved, and these are operated by a manual pulley system. Masking and Drapes We have six Tormentors (hard masking 6 meters by 1 m) which can be used to mask entrances and exits, along with various soft legs and borders. We also have a full stage white cyclorama (please notify us in advance if you would like to use this). Power (Touring) Cornerstone has one 63 Amp 3-phase supply, or two 32 Amp 3-phase supplies available for use by touring companies; these supplies are situated in the scene dock. There is no distro unit or 3- phase cable carried in house. This supply is independent of the other LX and Sound circuits situated in the auditorium. General Equipment 8 x Techpro single channel coms packs with headsets 12 x Cue lights 1 x Stage managers desk including coms and cue light Master Station. 10 x Litedeck Staging (1m x 2m) 2 x 1m LiteDeck handrail 2 x 2m LiteDeck handrail 40 x 2ft Aluminium legs for LiteDeck 1 x Set of treads for LiteDeck 5 x 6m x 2m Rolls of Vinyl dance floor. 1 x Lectern

3 Lighting Information Cornerstone s lighting grid runs on 16 Amp single phase 3-pin CEEFORM connectors. There are limited 16A-15A and 16A-13A converters available in house. Current set up is 2x advanced FoH bars and 4x onstage bars; each bar contains 2x six way IWB. Cornerstone does have limited 32 Amp circuits available for larger fixtures; these are all at stage level. Cornerstone has 2 DMX universes available to use. There are no DMX injection ports available at stage level; DMX injection is only available from the control booth at the rear of the auditorium. Cornerstone holds a very limited amount of gel in house, please contact us for a detailed list. Control 1x ETC Congo JR with sub-master wing 1x Zero88 Orb XF Lantern Stock 20x DTS Par62 Parcan 20x Source 4 Par 550W, 62 degree lens (other lenses are available) 4x ABD Cyc 1kW single cell flood 3x ABD Cyc 1kW four cell flood 22x ETC Source 4 15-30 Zoom 8x ETC Source 4 25-50 Zoom 2x ETC Source 4 36 degrees 8x ETC Source 4 26 degrees 11x ETC Source 4 19 degrees 2x ETC Source 4 10 degrees 6x ABD 1kW Fresnel 5x Combi Spotlight 1kW Fresnel 4x ABD 2kW Fresnel 8x ABD 630W PC 4x Scrollers to fit 2k Fresnel 8x Scrollers to fit fixed zoom Source 4s Movers and LED 8x Pulse LEDBAR 320 12 x Martin Rush MH-6 Moving Led Wash (re-chargeable) 2 x Martin Rush MH-5 Moving Led Profile (re-chargeable) 5x Selador Vivid R LED Flood. Lighting hardware 4x Four-lantern T-bars 4x Medium stands for T-bars 4x Small stands for T-bars 6x Single light floor stands 12x IWB 4x Six-way Socapex-16A break-out boxes. 6x Socapex (male)-16a tails Various lengths of Socapex and TRS available.

4 Sound Information The Front of House PA consists of: 2x EM Acoustics i-12 Subwoofers and 2x EM Acoustics EMS- 121 tops ground stacked either side of stage, as well as 2x EM Acoustics tops flown either side of the proscenium arch, in front of the stage header. The system is governed by a DBX Driverack Venu360 and powered by 3x QSC PL236 amplifier. We are only able to offer touring companies L&R control over the system at present. Control Equipment 1x Allen & Heath GLD 80 with 1 x AR2412 SB (24 in and 12 out) 1 x AR 84 SB (8 in and 4 out) 1x Tascam MD player 1x Dual CD player with auto pause 2 x Crown XTI 4002 (650w per channel at 8 Ohm) 5x QSC PL236 dual channel Amplifiers (725W per channel at 8 Ohm) 1x QSC PL218 dual channel Amplifier (340W per channel at 8 Ohm) 1x QSC PLX3102 dual channel Amplifier (550W per channel at 8 Ohm) Stage Monitors 4x Logic System ML 12 (400W RMS at 8 Ohm) 2x Logic System ML 15 (500W RMS at 8 Ohm) Other 2x EM Acoustic i-8 subwoofer (600W RMS at 8 Ohm) 4x EM Acoustic i-2 Front Fills (400W RMS at 8 Ohm) 2x JBL EON 115 1x Presonus Studiolive 16.0.2 Microphones 4x Shure SM58 4x Sure SM57 4x Shure Beta58 4x Shure Beta57 1x Neumann KMS105 3x AKG C100 4x Sennheiser 604e 1x AKG D112 1x AKG c451 EB 2x Sennheiser Wireless Hand held mics with e845 capsules Battery re-charge 2x Sennheiser Clip on Tie mic Battery re-charge 3x CPC Gooseneck condenser mics. 4x Klark Teknik DN 100 Active DI 6x Emo single channel passive D.I. Stage Equipment 2x 10 meter 16 way stage box with XLR tails 10x tall boom mic stands. 2x short boom mic stands. 2x kick drum mic stands. 2x table top mic stands. 2x banqueting mic stands. Various different lengths of XLR and NL4 Speakon available.

5 Audio visual Cornerstone has a number of portable projectors available for use in house; their use may be recharged. There are also a limited number of laptops available to be used these must be booked at least 1 week in advance, and may be re-charged. In the auditorium, there is one projector flown on house bar 15, next to the technical box; there is a corresponding motorised screen flown on house bar 4. There is no shutter for the flown projector, although there is an inbuilt AV mute facility. All AV is patched through the house systems using VGA to Cat5 converters and the house Data ring. There are limited converters for Apple computers carried in house, please check in advance if your MAC is supported. Hearing loop: Cornerstone has a Sennheiser Infrared hearing loop installed, and 10 headsets available from box office. Show relay: Cornerstone has a show relay which feeds from the auditorium into the backstage areas and the office. It is manually switched on by the duty technician prior to a show. Should you wish the show relay to be used, please inform the duty technician on the day of your performance. All incoming equipment must display a valid PAT test sticker. Any equipment that does not may be tested by one of the house technicians this may incur a charge per item. Replica weapons (including firearms, knives, and swords), or pyro technics being brought in by a touring company must be brought to the attention at least ONE MONTH prior to show date. This is in order for us to notify the relevant authorities and insure risk assessments are in place. Please contact the below for all technical enquiries. Grover HALL (Technical Coordinator): Gover.hall@southoxon.gov.uk, 01235 515137 ENDS