A Division of Impact Lighting STAR PANEL INSTALLATION MANUAL

Similar documents
Surface Mount Installation Manual

Surface Mount Installation Manual

APSPB PUSH BUTTON ZERO Installation Manual

Digital Lighting Systems. DIGTAN4-PRO Converts 4 PROTOCOL channels to 4x 0.5 V to 10 VDC Analog

Warner Photoscanner MCS-500 Series LED Photoelectric Control

WINEGARD INSTALLATION MANUAL. Model GM Carryout Ladder Mount for mounting pipes with outer diameters between 1 to 1-1/8

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R. EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual

USER MANUAL Table of Contents

USER MANUAL Table of Contents

HD VIDEO IP STREAMER CT-HDVD-HDSTR-KIT

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

INSTALLATION GUIDE. Axle Weighing Truck Scale. 60,000 lb x 20 lb Factory Calibrated Includes Pre-interfaced Wireless Remote LED Scoreboard Displays

Enable-IT 821P PoE Extender Quickstart Guide Professional Grade Networking

User Manual. Model 979T and 979R Digital Audio Converters

Enable-IT 824WP Outdoor Waterproof PoE Extender Kit Quickstart Guide Professional Grade Networking

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

ST60-DVC VTR CONTROLLER ST60-AG57 VTR CONTROLLER

Model /29S RF Splitter

VGA Extender LR EXT-VGA-141LR. User s Manual

User Manual HDBaseT 70 Transmitter & Receiver

USER MANUAL. MODEL 460RC Rack-Mounted G.703 Coax to Twisted Pair Adapters (BALUNs)

Quick Release Roof-Mount Kit MB700

AEXX-200F SERIES 4-DIGIT LINE FREQUENCY MONITORS

Low Voltage Multifunctional LED Controller / DMX Decoder. Specification

MWT-FM. Operation Manual. FM Single Channel Transmitter. man_mwtfm.

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R

Instant 802.3af Gigabit Outdoor PoE Converter. Model: INS-3AF-O-G. Quick Start Guide

Table of Contents. Introduction Pin Description Absolute Maximum Rating Electrical Specifications... 4

Omnidirectional TV/FM Antenna

DD E SIG N E D & E N GIN EE R E. Holman Garden Lights App Instruction Manual. Android Android manual

VGA Extender LR EXT-VGA-141LR. User s Manual

Electronic M.O.P Card. Instruction Manual Model D

Flarm Speaker. Installation Manual Version 1.00

1:2 VGA Audio Over CAT5

Viztrac AM200 User s Guide. Page 1 of 12

CS x1 RS-232 Computer Controlled Video Switcher. Instruction Manual

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

3M Locator Plate N

Enable-IT 860C PRO Coax Gigabit Professional Grade Ethernet Extender Kit Quickstart Guide

HTP1502W1 Remote Controlled Multicolor Lighting System

User Instructions. 16 SCB Sync Station.

Installation Manual SaVi Note Underwater LED Light

LWX-1. Satellite Weather Radio Module Installation Instructions A

OWNER'S MANUAL MYCRO SUB

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

Enable-IT 865W PRO Gigabit Professional Grade PoE Extender Kit Quickstart Guide

User Manual. Model 1372A and 1374A HDMI Switchers. 1T-SX-632 Model 1372A 2X1 Switcher. v1.3 2x1 SWITCHER. v1.3 INPUT ENHANCE POWER

User Manual TLS HDMI Switch 4/1 MHL

VGA Extender SRN. EXT-VGA-141SRN. User Manual

STD-525T PRECISION TIMER

FTC AGL System Controller Reference Manual Part Number

Enable-IT Port Extended Gigabit Ethernet DSLAM Quickstart Guide

Enable-IT 865 Q PRO Gigabit Professional Grade PoE Extender Kit Quickstart Guide

In-Wall Control Mount for ipod Touch

User Manual. Model 1351 DVI Repeater with HDCP

Enable-IT Port Extended Gigabit Ethernet PoE DSLAM Quickstart Guide

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Um MT INSPECTION SCOPE INSTRUCTION MANUAL NANOMETER TECHNOLOGIES

Enable-IT 860 PRO Rev D Gigabit Ethernet Extender Kit Quickstart Guide Professional Grade Networking

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

Enable-IT 860 PRO Rev C Gigabit Professional Grade Ethernet Extender Kit Quickstart Guide

4x4 Component Matrix over CAT-5

Model No. ST100 VTR CONTROLLER

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

Dystrybucja i sprzedaż: Meditronik Sp. z o.o Warszawa, ul. Wiertnicza 129, tel. (+48 22) , fax (+48 22)

Valcom Wired Digital Clock

USER MANUAL Table of Contents

Metal Electrode Meter

REQUIRED TOOLS. Wire cutters Razor blade Soldering iron Pliers 11/16 Wrench for Tube 18mm Wrench for Ring

Model No. ST60-S (-SRN, -SRK, -DRN, -DRK)

OPERATIONAL MANUAL EMZS CH Speaker Zone Selector. Version 1.6

JACK Digital HDTV Over-the-Air Antenna

LIGHT COPILOT II. elationlighting.com Internet:

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

CC2000 SERIES SYSTEM CLOCKS / DISPLAYS

TV Lift System Model CL-65 Installation Instructions

Model No. ST60-SPS (-SRN, -SRK, -DRN, -DRK)

Extender w/ RS-232 and 2-way IR

MWCS-CC9-MYA MYE 900MHz CableSAT TV Channel Changer

RS232 settings are internally definable via jumper blocks, to accommodate interfacing with a wide range of control products.

Specifications. Compatible Receivers. Compatible Satellites. DIRECTV Sat DISH Sat DIRECTV Receiver Compatibility

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

*Prefer. 600 MHz 4K ULTRA. 60Hz, 4:4:4. over one SC-Terminated Fiber-Optic Cable EXT-DP-4K600-1SC. User Manual. Release A1

INSTRUCTION MANUAL PELLAR PHONO PRE-AMPLIFIER. Extended 5-Year Warranty

QUICK START GUIDE SL-6. Powering and Wireless System for the 688 Field Production Mixer

HD100BaseT-Balun Kit

HDMI Extender Transmission more than 3800M

HD-1x2-4K. Ultra Slim 6G HDCP 2.2 1x2 HDMI Splitter. Factor Electronics

MWCS-AT9-MYA MYE 900MHz (Wireless) CableSAT

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

ASP-FIBRS1 User Manual

Model 570 Fiber Optic

MARCO CORNER, 19/ THIENE (VI) ITALIA

EZCOM-1. PLC - to - AMS MESSAGE DISPLAY INTERFACE INSTALLATION AND OPERATING INSTRUCTIONS. Rev March, 2001

SHOOT THE TARGET ACCESSORY

OA White OA Black. Owner s Manual. Low Profile Digital HDTV Over-the-Air Antenna. w/built-in KING SureLock Digital TV Signal Meter

4X1 Gefen TV Switcher GTV-HDMI N. User Manual

Enable-IT 865 PRO Rev E Gigabit PoE Extender Kit Quickstart Guide Professional Grade Networking

Transcription:

A Division of Impact Lighting STAR PANEL INSTALLATION MANUAL

A Division of Impact Lighting Fiber Optic Star 2 Lighting Systems Congratulations on your purchase of your new star panel system! Epic Sky is the ORIGINAL MANUFACTURER of the most advanced LED star ceiling technology on the market today! AWARD WINNER PACKAGE CONTENTS In this kit you will find the following: Acoustical fiber optic panels Mounting anchors Power Adapter or Commander Lead Wire(s) RJ45 Quick Connect Cables Hex Tool Poker Tool 12V Power Supply Spacers* Some installers use spacers for standard installation requiring more room for wires. Note: Sometimes there will be more than one lead wire and sometimes the wire(s) will already be attached to the power supply. WHAT YOU WILL NEED For a smooth installation we highly recommend the following: Chalk line reel Painters tape or a light adhesive masking tape Sharp X-acto Knife or box cutter 3M Adhesive spray Ladder A work buddy A Division of Impact Lighting A DIVISION OF IMPACT LIGHTING INC. 2101 West Central Blvd. Orlando, Florida 32805 USA Phone: 1.800.507.5714 Fax: 407.745.4584 Email: sales@epicskytech.com epicskytech.com

POWER SPECIFICATIONS 1 Power Supply: 25W 45W 60W 100W Number of Panels 10 Panels 18 Panels 24 Panels 40 Panels Power Supply: 150W 200W 250W 300W Number of Panels 60 Panels 80 Panels 100 Panels 120 Panels Note: If you have more than 120 panels, please contact our customer service department.! WEAR LATEX GLOVES TO KEEP PANELS CLEAN WHILE HANDLING! PLUG AND PLAY COMPONENTS OUR EASY PLUG AND PLAY SYSTEM MAKES INSTALLATION A SNAP! Leave the lead wire from the POWER ADAPTER OR COMMANDER hanging off the side of the first panel to you can connect the next panel. The flat design of the power adapter and power supply allows for you to be able to sandwich them between the ceiling and surface mount panels if using spacers. White gaffers tape, glue dots, or double sided tape are helpful in organizing RJ45 Cables during installation. Typically power supply and power adapter(or commander) will be installed above the ceiling. 12V POWER SUPPLY PHOENIX CONNECTOR IN SYSTEM OUTPUT RS232 IN +V -V DC OK LEAD WIRE COMMANDER POWER 12VDC + RS232 GND RX TX 12V/1.67A DC OK +V ADJ + POWER ADAPTER OR COMMANDER 100-240VAC 0.55A 50/60Hz STAR BOARDS N L GREEN = GROUND N = NEUTRAL L = LINE POWER IN RJ45 IN RJ45 IN LEAD RS232 JUMPER CABLE (35 ) RS232 JUMPER CABLE RS232 JUMPER CABLE

PACKAGE CONTENTS 2 ACOUSTICAL FIBER OPTIC PANELS MOUNTING ANCHORS HEX TOOL POKER TOOL SPACERS RJ45 QUICK CONNECT CABLES 12V POWER SUPPLY POWER ADAPTER (IF YOU ORDERED A COMMANDER YOU WILL NOT HAVE A POWER ADAPTER) COMMANDER (IF YOU ORDERED A POWER ADAPTER YOU WILL NOT HAVE A COMMANDER)

WIRING DIAGRAM 3 Up to 12 panels can be connected together in any configuration per lead wire. If your installation requires more than 12 panels, you will need an additional lead jumper wire and may need to add an additional Power Supply and POWER ADAPTER or COMMANDER. See PAGE 1 Power Specifications. CONFIGURATION WITH POWER ADAPTER 12V POWER SUPPLY LEAD WIRE POWER ADAPTER +V -V DC OK 12V/1.67A DC OK PHOENIX CONNECTOR IN +V ADJ + 100-240VAC 0.55A 50/60Hz N L LEAD RS232 JUMPER CABLE (35 ) POWER IN GREEN = GROUND N = NEUTRAL L = LINE CONFIGURATION WITH COMMANDER 12V POWER SUPPLY LEAD WIRE +V -V DC OK 12V/1.67A DC OK + +V ADJ 100-240VAC 0.55A 50/60Hz SYSTEM OUTPUT COMMANDER POWER 12VDC + RS232 IN RS232 GND RX TX N L POWER IN GREEN = GROUND N = NEUTRAL L = LINE COMMANDER DIAGRAM BELOW IS AN EXAMPLE WIRING DIAGRAM FOR A BASIC STAR PANEL CONFIGURATION. ELEMENTS SHOWN ARE NOT TO SCALE.

INSTALLATION STEPS FOR SURFACE MOUNT 4 1 THE MOST IMPORTANT STEP INSTALLING YOUR STAR CEILING PANELS IS STARTING FROM THE CENTER OF YOUR ROOM AND WORKING OUT. Find the center of the room by marking out an X from corner to corner NOTE: Not every room is square! Mark your center by marking out an X from corner to corner. EXACT MEASUREMENTS ARE CRITICAL. TAKE YOUR TIME. USE A CHALK LINE FOR MARKING. 2 Measure out a panel grid from the center out using a chalk line for guides. Your grid will correspond to the size panels you ordered. 24 x 24 or 24 x 48

INSTALLATION STEPS FOR SURFACE MOUNT 5 HELPFUL HINT: Before poking a hole with the Poker tool, place a piece of painters tape on the inside corners of each panel front. This way you can see where you have poked your hole when it comes time to screw in your roto fasteners 3 Hold up your first panel to the chalk line, and using the poker tool provided, poke a hole through each corner of the panel and into the ceiling. NOTE: poke holes approximately 4 in from each panel corner. painters tape 4 Screw in Roto Fasteners into the ceiling where you poked the NOTE: When Rotofast is securely screwed into the ceiling, snap the attached hex cover into place.

INSTALLATION STEPS FOR SURFACE MOUNT 6 5 Connect the lead wire coming from the power adapter or commander to the starboard. Make sure the RJ45 connector is placed into the IN port first panel you are installing. Connect your shorter jump wire into the OUT port that will lead to the IN port of your next panel to be placed. Refer to wiring diagram on page 3 for connection instructions. 12V POWER SUPPLY LEAD WIRE +V -V 12V/1.67A DC OK +V ADJ + 100-240VAC 0.55A 50/60Hz N DC OK L PHOENIX CONNECTOR IN POWER ADAPTER CLICK JUMP CABLE FROM OUT PORT TO NEXT PANEL BOARD NOTE: Firmly place RJ45 connector in the port. Your should feel a click indicating a secure connection LEAD CABLE TO IN PORT RS232 IN SYSTEM OUTPUT COMMANDER LEAD CABLE IS 35 FEET POWER 12VDC + RS232 GND RX TX COMMANDER (OPTIONAL) 6 Place Star Panel back up to template and line up holes to installed Rotofast anchors. This is where you want a partner to help hold and line up panels. painters tape NOTE: If you used painters tape to mark your holes lining up your star panels to anchors will be easy!

INSTALLATION STEPS FOR SURFACE MOUNT 7 7 Screw in Rotofast anchors into the ceiling using HEX tool to push and tighten counterclockwise. Use gentle pressure and slow turns with the HEX tool. It may take a few turns to engage the fastener. A firm connection is desired but it is very important to not over tighten rotofast. TURN SLOWLY WITH FIRM PRESSURE COUNTERCLOCKWISE NOTE: DO NOT OVER TIGHTEN ROTOFAST ANCHOR. 8 Repeat process, installing your next panel and connecting your jump wires into the correct IN and OUT ports. Make sure to use gentle pressure and that each panel is level and flush to adjoining panels for a smooth overall surface NOTE: Remember to work from inside out.

INSTALLATION STEPS FOR DROP CEILING 8 1 Connect the lead wire coming from the Power Adapter OR Commander to the starboard. Make sure the RJ45 connector is placed into the IN port first panel you are installing. Connect your shorter jump wire into the OUT port that will lead to the IN port of your next panel to be placed. Refer to wiring diagram on page 3 for connection instructions. 12V POWER SUPPLY +V -V 12V/1.67A DC OK +V ADJ + 100-240VAC 0.55A 50/60Hz N DC OK L PHOENIX CONNECTOR IN LEAD WIRE POWER ADAPTER CLICK NOTE: Firmly place RJ45 connector in the port. Your should feel a click indicating a secure connection JUMP CABLE FROM OUT PORT TO NEXT PANEL BOARD SYSTEM OUTPUT RS232 IN LEAD CABLE TO IN PORT COMMANDER POWER 12VDC + RS232 GND RX TX LEAD CABLE IS 35 FEET COMMANDER (OPTIONAL) 2 Insert Star Panel into drop ceiling frame. Star Board and Fibers Star Panel Drop Ceiling Frame

CUSTOM CUTTING 1 NOTE: Always cut on a flat surface. Spare cardboard works great. Make sure your knife is sharp so you don t tear or pull the fabric 9 To field cut star panels for protruding objects such as drop beams, canned lights, or air conditioning vents, mark the location of the protrusion on the upper (unfinished) side of the panel. Use a sharp NON-SERRATED knife or box cutter. Cut the desired shape down through the fiberglass but NOT THROUGH THE FABRIC. Set your knife blade. Take your time! 2 3 4 Remove the cut fiberglass piece from the panel. Carefully cut a clean X into the center of the fabric. Fold flaps back through the opening. 5 Spray back of loose flaps with a 3M super 77 spray and press flat to surface If a fiber or 2 is placed in a location you need to cut out simply cut the fiber, use the poker tool to make another hole in a location you desire, and push fiber through. (It may not be necessary to do this as each board is populated evenly.)

DIP SWITCH SETTINGS 10 The STAR EFFECTS are determined by the dip switches. The dip switch settings allow you to control a variety of effects including sparkle, scintillation, rain, strobe, etc.). Shooting Star 10 Min Setting Shown Above SWITCH 1 SWITCH 2 SWITCH 3 SWITCH 4 Night Sky Up Up Up Up All on 50% Down Up Up Up All On 25% Up Down Up Up Meteor Shower Down Down Up Up Night Sky 50% Up Up Down Up Scintillation Down Up Down Up Tropical Winds Up Down Down Up Constellation Mode Down Down Down Up Shooting Star 10 Sec Up Up Up Down Shooting Star 1 Min Down Up Up Down Shooting Star 2 Min Up Down Up Down Shooting Star 5 Min Down Down Up Down Shooting Star 10 Min Up Up Down Down Rain Mode Down Up Down Down Party (Strobe) Mode Up Down Down Down All on 100% Down Down Down Down *NOTE* Epic Star Boards will read the DIP switch setting on power up. Check that the boards are in the right mode before installing in a ceiling.

COMMAND SETTINGS 11 All commands must be terminated by a carriage return. All commands are repeated out the serial port to pass to the next controller or device. The E symbol means that those command values are stored in EEPROM and will load on power up. COMMAND ACTION NOTES ess Night Sky Night Sky in 3D perspective ess1 Night Sky 50% Night Sky in 3D perspective at 50% brightness es2 Scintillation Scintillation es3 Tropical Winds Tropical Winds - Fast Sparkle esr Rain Shower Stars in Rain Shower mode est Party Mode Stars all on with strobe/fade out pattern esldxxx *E Stars on Solid xxx is the level, 1-255, 255 is the brightest ecn Constellations on Solid All LED s on solid - separate than star commands ecsp Constellation Sparkle Constellations sparkle eco Constellation Off Only Constellations turn off eclvxxx *E Constellation Solid Level xxx is the level, 1-255, 255 is the brightest! Trigger Shooting Star Immediately trigger shooting star ssj Shooting Star 10 Seconds Shooting Star every 10 seconds, Adjustable via RS-232 ss1 Shooting Star 1 Minute Shooting Star every minute ss2 Shooting Star 2 Minutes Shooting Star every 2 minutes ss5 Shooting Star 5 Minutes Shooting Star every 5 minutes ssz Shooting Star 10 Minutes Shooting Star every 10 minutes sso Shooting Star Off Boards in shooting star mode will turn off ssg Shooting Star On Shooting star on mso Meteor Shower On Meteor Shower mode (DIP switches must be set correctly) Default rate is every 2 minutes msf Meteor Shower Off Stops the meteor shower ssd Power on Setting Return to Power on DIP Switch Setting esdmxxx *E Dim Setting (stars only) Brightness level of stars, 1 to 255, Default is 255 (brightest) espkxxx *E Star Sparkle Speed Sparkle Speed, 0-255, default is 17, the higher the number, the slower the sparkle mtspxxx *E Meteor Shower Speed xxx is the The Speed of the Meteors in the Shower, 0-255, Default is 50 (higher is slower) mttmxxx *E Time Between Meteors Time in 1/10 s of a second between each meteor in the shower (0-255) default is 7 mtinxxx *E Meteor Shower Interval Time in seconds between meteor showers (0-255) default is 120 mtnmxxx *E Meteor Number Number of meteors per shower (1-255) default is 19 ssspxxx *E Shooting Star Speed xxx = 0 (fastest) to 254 (slowest), default is 40 sstmxxx *E Shooting Star Interval Interval Between Shooting Stars in seconds, 0-255, Default is 10 eso Stars Off All Stars Off esn Stars On Turns on the stars in the last mode they were in globaloff All Off All Stars off, regardless of mode NOTE: The Epic Star Boards will read the DIP switch setting on power up, check that the boards are in the right mode before installing in a ceiling.

TERMS AND CONDITIONS 12 Impact Lighting, Inc. TERMS AND CONDITIONS 1. Contract No quotation or order acknowledgment to terms of these terms and conditions shall be changed in any respect except as specifically agreed to in writing and signed by an authorized officer of Impact Lighting, Inc. No statement, representation or warranty not contained herein shall be binding on Impact Lighting, Inc., unless made in writing and signed by an authorized officer of Impact Lighting, Inc. 2. Payment Unless other arrangements have been authorized by our office in writing, all orders require a 50% deposit to accompany any purchase order or proposal acceptance, with balance due and paid prior to shipment. Payments must be made directly to Impact Lighting, Inc. Payments made otherwise are unauthorized, as there are no other parties authorized to collect money for Impact Lighting, Inc. and thus payments made to other parties or entities are made at purchaser s own risk. ONCE AN ORDER HAS BEGUN PRODUCTION IT CANNOT BE CANCELED. Changes to orders are subject to a change order process and may incur additional fees and extend lead times. 3. Prices Price quotes can be obtained from authorized Impact Lighting, Inc. representatives ONLY. Quotations are firm for 30 days, and otherwise are subject to change without notice. Prices do not include freight or tax unless specifically noted. 4. Shipping Dates Average shipping time is 4-6 weeks after receipt of order and deposit, however this can vary. Please consult your sales rep for expected shipping dates for specific orders. Our estimated shipping dates are our best approximation of a probable shipping date and shall not be deemed to present a fixed or guaranteed date. Impact Lighting, Inc. shall not be responsible for any damages, penalties or charge backs resulting from delayed shipments or from its inability to ship by the estimated shipping date. 5. Consequential Damage Impact Lighting, Inc. shall not be liable for any consequential, contingent, or incidental damages whatsoever. Impact Lighting, Inc. is not liable for damages of any kind resulting from any delay or failure to deliver or perform due to strikes, lockouts, or other labor difficulties, or failure due to delay of sources of supply, transportation difficulties, accidents, fires, acts of God, or any other causes of like or unlike nature beyond Impact Lighting, Inc. s control. 6. Installation and Limited Warranty All of our products are manufactured with UL, ETL, or CE approved components. All fixtures shown in our catalog conform to all applicable UL standards at the time of printing. Impact Lighting, Inc. reserves the right to change or improve the design or components of any of its products due to availability or changes in UL standards, without assuming any obligation to modify any product previously manufactured and without notice. All equipment is tested and inspected prior to shipment. All secondary parts warranties are carried by their respective manufacturers with typical industry standard warranty periods. Buyer must inspect goods for any defects prior to installation, within 10 days of receipt. No claims will be accepted after 10 days. All goods must be installed and inspected by a qualified installer or electrician, as appropriate for the product. Impact Lighting, Inc. warrants its products to be free from defects in material and workmanship for one year from date of purchase. This warranty is limited to the correction of any such defect or the replacement of the defective item. This warranty does not cover labor, shipping or installation costs, and specifically excludes any product that has suffered from misuse, negligence or accident, if it has been used in a manner contrary to accepted normal use or to Impact Lighting, Inc. s printed instructions, been improperly installed, overloaded, altered, tampered with, or otherwise abused in which any parts, including glass, have been reworked, repaired, or replaced outside of Impact Lighting, Inc. s facility. This warranty specifically excludes finishes due to the unsuitability of many cleaning agents. There are no other express warranties including any warranty of merchantability or fitness for particular purpose. Impact Lighting, Inc. shall not be liable for consequential damages or cost of removal and re-installation of its products. This warranty is strictly limited to the original purchaser. 7. Returns and Cancellation of orders All merchandise is custom made to order, and therefore we cannot accept returns or cancellations of an order. If the buyer, after approval of an order to Impact Lighting Inc. desires to cancel the order, and Impact Lighting Inc. accepts such, cancellation charges shall be 50% of the total price of the order or, if greater, the actual costs incurred by Impact Lighting Inc. with respect to the order at the time of 2101 West Central Blvd. Orlando, Florida 32805 USA Phone: 1.800.507.5714 Fax: 407.745.4584 Email: sales@epicskytech.com epicskytech.com