Dissolved Oxygen Transmitter

Similar documents
Dissolved Oxygen Transmitter

dissolved oxygen transmitter

ELE C TRO MAG N E T I C FLO W M E T E RS

Wall-/Pipe-Mount Level Indicator

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

innocon 6800D Online Luminescent Dissolved Oxygen Analyzer Opera ng Instruc on Dissolved Oxygen NORMAL REL 1 2 WASH 28.1 C jens WALL MOUNTING

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Oxymax W COS61. Technical Information. Dissolved oxygen measurement Optical sensor acc. to the fluorescence quenching principle

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Modular Lube Lubrication Systems System Controls

SPACESCAN SERIES SS 02

SAN ANTONIO WATER SYSTEM CENTRAL WATER INTEGRATION PIPELINE TERMINUS TREATMENT FACILITY SAWS Job No SAWS Solicitation No.

DMP 331i / DMP 333i LMP 331 i

Single Point Flow Monitor SW118 SW119

Flow Measurement SITRANS F M

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

LAUREL ELECTRONICS, INC.

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

Model KBF 115 Constant climate chambers with large temperature / humidity range

TFRN Industrial RTD temperature sensor. CombiTemp TM

Liquid Level Sensor Type AKS 4100U

TFRN Industrial RTD temperature sensor. CombiTemp TM

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

ISOMAG THE FRIENDLY MAG METER. Gas, mists or vapours Zone 0 1G Gas, mists or vapours Zone 1 2G. Gas, mists or vapours Zone 2 3G

Rack mounted telephone- and leased line modem for industrial applications

2291 Guided Wave Radar Level Transmitter

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

Ultrasonic Level Transmitter and Sensor

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Model KT 115 Cooling incubators with thermoelectric cooling

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

TFRH Hygienic RTD temperature sensor. CombiTemp TM

SITRANS F M. Transmitter MAG 5000/6000 4/33

A new generation of access control.

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

Installation Instructions Series 9000 DeviceNett PHOTOSWITCHr Photoelectric Sensors

Model KBF 1020 Constant climate chambers with large temperature / humidity range

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

Water temperature recommended range 5 45 C ( F) UV transmittance 254 nm, 1 cm) min. 45 %

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Fibre Optic Modem ODW-622

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

Liquid Level Sensor Type AKS 4100/4100U

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Model KT 53 Cooling incubators with thermoelectric cooling

Safety Light Curtains GuardShield

SAL Series Wireless Clock (V1)

Model KBF P 240 Humidity test chambers with ICH-compliant light source

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Multifunction devices

ABB. Measure IT Uvisor System MFD Multi Flame Detector - Control Unit. Product Data Sheet (Rev. C)

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Condition Monitoring Custom Products

LONWORKS Fibre Optic Converter

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Process Transmitter RMA 422

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model KBF 720 Constant climate chambers with large temperature / humidity range

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Liquid Level Sensor AKS 4100U

TELEDYNE HASTINGS INSTRUMENTS

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Liquid Level Sensor AKS 4100U

SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

ABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications

RLS Series RLS-GD-20/20 -UV. Design. RLS-GD Series Gloss Detection Sensors. Accessories: (cf. page 9) Product name:

EZ-LIGHT K90FDL Daylight Visible

1. General Specification

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Model KMF 240 Constant climate chambers with expanded temperature / humidity range

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

IMPAC Infrared Thermometers

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

Photoelectric Sensors E3F2

IMPAC Infrared Thermometers

LD OEM/LD PDS/LD PeCo

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

Analogue HD Monitoring Set: 8-Channel Video Recorder + 4 Outdoor Cameras

Technical data. General specifications. Indicators/operating means

L-LAS Series L-LAS-LT-50-SL-... Design. L-LAS Series Laser Line Sensors. Product name:

RMA42. Technical Information

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Flow Measurement SITRANS F M

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Model KT 170 Cooling incubators with thermoelectric cooling

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Photoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Transcription:

3 YEAR SENSOR WARRANTY 5.4 We reserve the right to continuously improve our products and make any change in the stated specifications and dimensions without prior notice.

General MJK Oxix s are designed for measuring the oxygen contents in open tanks exposed to sunlight, wells and closed containers. The Oxix sensor function is based on the fluorescence principle and does not consume oxygen like standard membrane-type sensors. It is rugged and designed to handle tough applications. Theory of Operation Light pulses with a wavelength of 475 nm are transmitted to a ruthenium compound immobilized in a sol-gel matrix. The ruthenium absorbs the light energy by changing the outer electron s energy level. The unstable electron then collapses and returns back to its original energy state and at the same time emits the surplus energy as a photon with a wavelength of 600 nm. This process is also refered to as fluorescing). When the intensity of the transmitted light pulses is tightly controlled, the amount of fluorescing is predictable and repeatable. If free oxygen molecules are present, the photon energy is absorbed by the oxygen molecules without any light emission, and the amount of fluorescing is consequently reduced (also refered to as fluorescence quenching). It is therefore possible to determine the amount of dissolved oxygen by measuring the amount of fluorescence quenching. Applications Sewage and wastewater plants Drinking water Biologic control Sludge treatment Filtering stations Fishponds and farms Calibration and cleaning The Oxix sensor is factory calibrated and will not require any re-calibration. The physical outline and structure of the sensor reduce frequent cleaning to a minimum. High Quality Materials The Oxix sensor is constructed of epoxy, polyurethane and PVC that withstand anoxic environments. Flexible Installation MJK s modular design allows up to 300 meters (950ft.) between the sensor and the converter, and the Display Unit can be mounted up to 1000 m (3000 ft.) from the signal converter with ordinary twisted wires. One Display Unit can control up to four Mag- Flux flow meters, SuSix transmitters and/ or Oxix transmitters for greater economy, space savings and an improved overview of the multiple measurement values. 1 pc. Oxix Converterr with display (206505) 3 pcs. Oxix without display (206508) ll RS- 485 ll RS- 485 4 pcs. Oxix sensors (206510) Max 1000 m ll RS- 485 2

Simple to Operate PC Connection Flexible In- and Outputs User-definable Text Modbus Communication The Oxix Display Unit has a mobile phonelike menu structure and can display text in several selectable languages. Oxix allows downloading setup configurations, uploading new instrument software updates and display customization. The onboard data logger captures 20.000 readings which are displayed as an electronic graph and can be retrieved as a CSV file on a PC. This connectivity is achieved with a common USB port and the free MJK Field Link software. The Oxix Transmitter has one 4-20 ma analogue output, two digital outputs for alarms or control, and one digital input for resetting alarms, batches, etc. Up to five lines of text and readings can be configured by the user. The graphic display is automatically adjusted to show the largest characters possible. Alarms can be displayed as pop-up alarms until they are reset. The Display Unit uses the Modbus RTU communication protocol to connect to the Oxix Transmitter. The Transmitter can in turn connect to SCADA systems with its Modbus communication protocol. Mechanical Dimensions Sensor 1/4 tube 1/4 tube fitting 1-1/2 NPT Cable to Oxix Converter 112 mm (4.2 ) 130 mm (5 ) Measuring element 57 mm (1.9 ) 3

Specifications Transmitter, Display Unit and Sensor Oxix Transmitter Accuracy +/- 0,1% of reading Measuring input RS 485 Analog output One active 4-20 ma, galvanically isolated (max. load 800 ) Digital outputs One voltage-free electromechanical relay (max. 50 V DC / 1 A) One optically isolated MOSFET relay (max. 50 VAC / V DC / 120 ma) Digital inputs One, max. 30 V DC, < 5 V DC = 0(low), > 10 V DC = 1(high), pulse length > 100 ms Communication MODBUS RTU-mode, 9600 baud, 2-wire RS 485, slave-mode Interface RS 485 for connection to Display Unit or PLC Power supply 10-30 V DC, or 24 V AC, 50 / 60 Hz ± 10 % or 115 V AC, 50 / 60 Hz ± 10 % or 230 V AC, 50 / 60 Hz ± 10 % Power consumption Max. 10 W Cabinet material Polycarbonate, glass reinforced Enclosure rating IP 67, NEMA 6 Temperature range - 20 60 C Weight 1,1 kg CE approvals EN 61000-6-4:2001, EN 61000-6-2:2001 Display Unit Enclosure rating Dust and waterproof IP 67, NEMA 6 (when mounted on converter) Housing material Polycarbonate, glass reinforced Protection lid Transparent polycarbonate Display White backlit LCD-display (64 x 128 pixels) with softkeys Indication Indication measurement, configuration and graph Clock Real-time clock with built-in battery backup Communication MODBUS RTU-mode, 9600 baud, 2-wire RS 485, master-mode Interface RS 485 Memory 256 Kb Flash memory, 20.000 entries with date, time and value Interface USB 1,1 type mini B, Female Temperature range - 20 60 C Oxix Sensor Dissolved Oxygen 0.00-25.0 mg/l (ppm) Measurement principle Optical, Near infra-red fluorescence (l in = 475 nm, I out = 600 nm) Sensor Check Automatic self-diagnostics Pressure 6 bar (100 psi) Materials Boby and Head: PU, PVC, silicone, epoxy and stainless steel 316 SS Optical lens: Sapphire O-ring: Viton Cable: PUR Cleaning system Built-in air or water jet Cable 4 x 0,326 mm 2, shielded, outer diameter Ø 5.0 mm (22 AWG) Cable length 10 m (33 ft.), can be extended up to 600 mm Response time t 90 less than 1 second, t 95 less than 60 second Flow velocity No flow required Power supply 12 V DC (10-16 V DC), approx. 10 ma Output RS 485, 9600 baud, 2-wire Accuracy Better than 1% of actual reading (0,02 mg/l) Resolution Better than 0,02 mg/l Temperature range 0-60 ºC Temperature compensation 0-50 ºC Enclosure rating IP 68 to IEC 529 (10 m), NEMA 6x Dimensions 50 x 130 mm (diameter x length) Mounting 1,5 inch NPT thread 0,25 inch NPT thread for jet spray cleaning tube Weight 0,82 kg (1.8 lbs) incl. cable Approvals EN 61000-6-4:2001, EN 61000-6-2:2001 4

5

+DC GND A B Max. four MJK converters with Modbus can be connected to one : Converter #1 2 wire Converter #4 4 wire + A B - + - C NO C1 N01 C2 N02 PE N L -Display- -ma- -DI- -D01- -D02- Mains supply + A B - + - C NO C1 N01 C2 N02 PE N L -Display- -ma- -DI- -D01- -D02- Mains supply Display unit +DC GND A B Max. four MJK converters with Modbus can be connected to one : Converter #1 2 wire Converter #4 4 wire Display unit Data Sheet Mechanical Dimensions 162 156 186 89 183 85 Converter and Display Unit 83 79 150 144 M20 Order Numbers Oxix Converter, Displays, Sensors and Accessories Pink 521269 Pink Grey Brown Shield 521269 Grey Brown Shield 521268 Line Fuse 24V AC: 500mA T Fuse 115V AC: 125mA T Fuse 230V AC: 63mA T 521268 Line Fuse 24V AC: 500mA T Fuse 115V AC: 125mA T Fuse 230V AC: 63mA T 206305, Oxix Converter with display 207930, Wall Mounting Kit 207935, Panel Mounting Bracket Converter mounted in a panel Oxix Converters - Oxix Converter w/ display, 10-30 V DC - Oxix Converter w/ display, 230 / 115 V AC - Oxix Converter w/ display, 24 V AC - Oxix Converter without display, 10-30 V DC - Oxix Converter without display, 230 / 115 V AC Oxix Converter without display, 24 V AC Oxix Sensor 206510 Oxix Sensor Accessories for Oxix Sensors 155230 Oxix Insertion adapter, 1½" NPT inner thread -> 2" RG outer thread 155236 Oxix Immersion fitting 691120 Cable for Oxix sensor (PUR) - 1½" NPT to 1¼" RG Adapter Distributed by: MJK offices Denmark www.mjk.dk mjk@mjk.dk +45 45 56 06 56 Norway www.mjk.no mjk@mjk.no +47 69 20 60 70 The Netherlands North America mjknl@mjk.com DK: +45 45 mjkusa@mjk.com 56 06 56 +31 251 672171 NO: +47 69 +1 20 847 60 482 70 8655 Sweden Australia www.mjk.se kontoret@mjk.se mjk@mjk.com +46 53 31 77 50 +61 3 9758 8533