PBS Products from Pyramid

Similar documents
Implementing a Proton Beam Scanning System within an Operating Clinical Facility

DOSE DELIVERY SYSTEM OF THE VARIAN PROBEAM SYSTEM WITH CONTINUOUS BEAM

G. Pittá(*), S. Braccini TERA Foundation, Novara, Italy (*) Corresponding author.

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

In-process inspection: Inspector technology and concept

Quality Assurance Implementation at the Roberts Proton Therapy Center. James McDonough 3 August 2013

The Silicon Pixel Detector (SPD) for the ALICE Experiment

Recent developments in cyclotrons for proton therapy at IBA

Ensemble QLAB. Stand-Alone, 1-4 Axes Piezo Motion Controller. Control 1 to 4 axes of piezo nanopositioning stages in open- or closed-loop operation

Linac 4 Instrumentation K.Hanke CERN

A dedicated data acquisition system for ion velocity measurements of laser produced plasmas

An Overview of Beam Diagnostic and Control Systems for AREAL Linac

Application Note #63 Field Analyzers in EMC Radiated Immunity Testing

EPJ Web of Conferences 95,

Therapy Control and Patient Safety for Proton Therapy

Promises and Perils of Proton Therapy Beam Delivery (Implications) or Towards Cost Effective Particle Therapy

Drift Tubes as Muon Detectors for ILC

BEAM DIAGNOSTICS IN THE CNAO INJECTION LINES COMMISSIONING

Review Report of The SACLA Detector Meeting

Electric Rotary Modules. Rotary Actuators

IMAGING GROUP. * With dual port readout at 16MHz/port Detector shown with a C-mount nose and lens, sold separately

HPS Slow Controls Overview

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

A Cathode Development Cornell Cultera This scope includes all labor and purchases required produce photocathodes required by CBETA.

These are used for producing a narrow and sharply focus beam of electrons.

Digital SWIR Scanning Laser Doppler Vibrometer

Jefferson Lab Experience with Beam Halo, Beam Loss, etc.

The Alice Silicon Pixel Detector (SPD) Peter Chochula for the Alice Pixel Collaboration

AREAL- Phase 1. B. Grigoryan on behalf of AREAL team

Transmissive XBPM developments at PSF/BESSY. Martin R. Fuchs

DIRECT DRIVE ROTARY TABLES SRT SERIES

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

OPTICAL POWER METER WITH SMART DETECTOR HEAD

INSTRUMENT CATHODE-RAY TUBE

PRACTICAL APPLICATION OF THE PHASED-ARRAY TECHNOLOGY WITH PAINT-BRUSH EVALUATION FOR SEAMLESS-TUBE TESTING

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

BTC and SMT Rework Challenges

Request for Proposals

Product Information. EIB 700 Series External Interface Box

Advanced Test Equipment Rentals ATEC (2832)

Status of GEM-based Digital Hadron Calorimetry

Electromagnetic Block Valves Direct Acting

Mechanical aspects, FEA validation and geometry optimization

Physics Requirements for the CXI Ion Time-of-Flight

Digital SWIR Scanning Laser Doppler Vibrometer

Front End Electronics

Hall-B Beamline Commissioning Plan for CLAS12

HAPD and Electronics Updates

The PEFP 20-MeV Proton Linear Accelerator

A Fast Magnet Current Change Monitor for Machine Protection in HERA and the LHC

Beam Loss Detection for MPS at FRIB

Connection for filtered air

THE TIMING COUNTER OF THE MEG EXPERIMENT: DESIGN AND COMMISSIONING (OR HOW TO BUILD YOUR OWN HIGH TIMING RESOLUTION DETECTOR )

Beam test of the QMB6 calibration board and HBU0 prototype

2 Work Package and Work Unit descriptions. 2.8 WP8: RF Systems (R. Ruber, Uppsala)

HD Review March 30, 2011 Franz Klein

Operating Instructions

National Institute of Radiological Sciences. Naoya Saotome

Innovative Rotary Encoders Deliver Durability and Precision without Tradeoffs. By: Jeff Smoot, CUI Inc

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

Polygon Scanners Capabilities, Applications and System integration. considerations

Front End Electronics

UNIGAS Hand-held combustion gas analyzer with 3 sensors

Development of BPM Electronics at the JLAB FEL

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

UTAH 100/UDS Universal Distribution System

Hitachi Kokusai Electric Comark LLC

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

Pixel Detector Control System

SPECIFICATION NO Model 207 Automatic GTAW Welding System

A pixel chip for tracking in ALICE and particle identification in LHCb

OMNISTAR GX2. GX2-LM1000E Series 1310 nm Broadcast Transmitter DATA SHEET BENEFITS. 1 GHz bandwidth

High ResolutionCross Strip Anodes for Photon Counting detectors

Model 4700 Photodiode Characterizer

V9A01 Solution Specification V0.1

Spatial Response of Photon Detectors used in the Focusing DIRC prototype

TECHNICAL SPECIFICATION Multi-beam S-band Klystron type BT267

Detailed Design Report

HIGH POWER BEAM DUMP AND TARGET / ACCELERATOR INTERFACE PROCEDURES *

... A COMPUTER SYSTEM FOR MULTIPARAMETER PULSE HEIGHT ANALYSIS AND CONTROL*

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

The FAIR plinac RF Systems

Digital BPMs and Orbit Feedback Systems

SPECIFICATION NO NOTE

General Specifications

APPLICATION NOTE. Fiber Alignment Now Achievable with Commercial Software

Switching Solutions for Multi-Channel High Speed Serial Port Testing

STATUS AND CONCEPTUAL DESIGN OF THE CONTROL SYSTEM FOR THE HEAVY ION THERAPY ACCELERATOR FACILITY HICAT

Monitor QA Management i model

Hello and welcome to this training module for the STM32L4 Liquid Crystal Display (LCD) controller. This controller can be used in a wide range of

CMS Upgrade Activities

Introducing Purion H, a Scanned Spot Beam High Current Ion Implanter

CSC Data Rates, Formats and Calibration Methods

Sharif University of Technology. SoC: Introduction

Ecoline S series. Precision solutions for quality production. Innovations for a better world.

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16]

Performance of a double-metal n-on-n and a Czochralski silicon strip detector read out at LHC speeds

MTL Software. Overview

Transcription:

PBS Products from Pyramid

Pyramid was founded in 1986 and is an established supplier of instrument control systems for the medical, semiconductor, physics and biological research markets. The systems typically involve specialized electronic hardware, embedded real-time software, and host system software drivers and applications. We have particular expertise in ion chamber development and low-current measurement which is central to PBS dosimetry. Pyramid has been active in particle therapy since 2006 and is now known as a leading supplier of pencil beam scanning equipment and software. We work closely with our customers to provide solutions ranging from individual components up to complete integrated nozzle systems, using field-proven products and exciting new technologies. Pencil beam scanning offers exciting opportunities to treat conditions that may be difficult or impossible to handle by other methods, with the promise of improved patient outcomes. Let Pyramid work with you to create a pencil beam scanning solution that is cost-effective, on-time and brings benefits to your product, your hospital, your practitioners and most of all, to your patients

Pencil Beam Scanning from Pyramid Pencil-beam Scanning (PBS) uses magnets to guide fine proton beams toward a tumor and away from critical structures. No scatterers are placed in the beam path. The method is favored by practitioners because it is clean and precise. Various implementations of pencil beam scanning are in use or under investigation. The most established technique is discrete spot scanning, or point-and-shoot where the pencil-beam is applied to a particular spot until the accumulated dose reaches the set value. The beam is then turned off while the current to the scanning magnets is changed for the next spot and the process continues through the spots one at a time. A complete layer is painted at one beam energy, then the energy is reduced layer by layer. However PBS is inherently flexible and other possible modes being researched include continuous beam motion combined with velocity and/or beam current modulation, spot by spot energy variation, multiple paintings of the whole target and many others. In all cases PBS requires highly accurate control of beam dose and beam position. The precise control and redundant monitoring of all parameters that affect dose placement is vital. The Pyramid Technical Consultants PBS components for particle therapy systems have been developed to be accurate, safe and highly reconfigurable. They can be the basis of new designs or can be installed into existing treatment rooms. Pyramid PBS products include a range of ultra-thin transmission ionization chambers and readout, scan magnets and amplifiers, helium beam paths and isocenter diagnostic devices. In-house design and fabrication capability and close working relationships with key suppliers allow designs optimized for customer needs to be produced quickly and efficiently. Fully-integrated software control offers the automation, speed and flexibility needed to make the PBS process clinically practical and fast to implement.

Nozzle Systems Pyramid can provide complete nozzle systems to specific customer requirements, including: vacuum and helium windows beam position monitor scan magnets and amplifiers helium-filled beam path dose and position-sensing ionization chambers with readout redundant real-time controllers for map execution and interlocking control software to receive, validate and prepare treatment maps hardware and software interfaces to accelerator systems, patient positioners, gantry motion, access controls and others control software to interface with other systems like oncology information systems, treatment planning, patient imaging and others, using standard DICOM format. Beam position monitor Helium beam path Ion chambers Two-axis scan magnet system Irradiation field Read out Hall probes Read out Read out Interlock loop Scan amplifiers Real-time controller Accelerator control DICOM interface PBS server computer Accelerator Gantry PPS Imager

Nozzle Systems This illustration of nozzle system components shows the MPM8-500 multipole combination scan magnet with four SX-500 amplifiers. A helium beam path reduces scattering as the beam passes through the magnet and on to the ionization chambers. A pair of IC128-25 ionization chambers provides redundant readout of beam current, position, shape and trajectory for every delivered spot. I128 readout electronics computes the beam properties in real time and checks for deviations from the treatment map. The system communicates with the accelerator to control beam energy and current, coordinating with the movement of the beam spot. Any of six real-time controllers has the capability to suspend the irradiation if there are fault conditions, providing a high degree of redundancy. In addition to the beam gating control used during the irradiation, a shutdown escalation can be commanded through two separate hardware relay circuits. One circuit is room-specific, and is used typically for map tolerance violations. The other circuit is system-wide and is used for hardware failures, access violations and similar events.

Ionization Chambers Ionization chambers are the heart of an effective pencil-beam delivery system. They must provide fast, accurate information with high reliability, while having as little influence on the beam as possible. The Pyramid range of chambers provides a number of different geometries to suit customer needs for scan field size or beam size, high beam current capability including pulsed beams, position resolution and amount of redundancy. Key features include ultra-thin electrode substrates for minimal beam scattering, highly precise and stable electrode patterns for accurate position determination, built-in pressure and temperature sensors for gain compensation and desiccant cartridges for fill gas dehumidification.

Ionization chambers Pyramid s dedicated in-house laser patterning equipment ensures tight control of this vital process. Every completed ionization chamber is tested for position readout linearity and gain flatness with an X-ray test system. New electrode structures can be designed and quickly tested to meet customer needs.

Ionization chambers The range of ionization chamber products includes large-area detectors with strip readout and integral dose planes, for use in the scanned beam. Small-area detectors with strip readout or pixel readout are for use upstream of the beam scan magnets, for measurement of beam trajectory and shape. In this application, a construction with absolute minimal beam energy degradation and scattering is vital. Chambers like the PX-1 with pixelated readout provide significant extra information about the beam. Treatment plans typically assume symmetric beams with Gaussianlike profiles. If beamline setups are incorrect, the actual beams may be elliptical and inclined, or have extended halos, multiple peaks or other pathological conditions. The Pyramid pixelated imagers reveal these cases and allow the user to trace and eliminate the underlying problem. Pixelated chambers also allow the ultimate low scattering designs to be created. The water equivalent thickness of the electrodes in the Pyramid PX-3 chamber is less than 50 µm.

Beam Position Monitors The BPM16-38 beam position monitor comprises a robust, small ionization chamber with two-axis strip readout integrated with a pneumatic actuator that can move the chamber completely clear of the beam when it is not being used. It may be used for beam trajectory checking before the scan magnets in a nozzle system, and also generally along a high-energy beam transport line to aid beam tuning. The whole assembly is high-vacuum compatible, and is available with alternative vacuum flanges. It can operate in any orientation.

Ionization Chamber Summary Specifications The Pyramid ionization chamber designs listed here cover many customer requirements. However, if you need something a little different, we are happy to propose a new design which can be created quickly using our in-house facilities. Device Sensor Active Area Readout Elements Active Gap Types # Gaps Active Gap Size (mm) Max HV (V) Strip/pixel pitch (mm) IC128-25 25 cm sq 128 by 128 strips Strip 2 10.00 3000 2.00 Dose plane Dose 1 10.00 (a) IC32-20 20 cm sq 32 by 32 strips Strip 2 10.00 2000 6.25 Dose planes with density spot Dose/Dose density 2 10.00 (a) IC64-16 16 cm sq 64 by 64 strips Strip 2 5.00 3000 2.50 Dose planes Dose 2 3.00 (a) IC16-5 5 cm sq 16 by 16 strips Strip 2 3.00 1500 3.00 PX-3 4.2 cm dia 120 pixels Pixel 1 5.00 1500 3.80 (a) PX-1 4.2 cm dia 120 pixels Pixel 1 10.00 1000 3.80 (a) PX-2 4.2 cm dia 120 pixels Pixel 1 7.62 1000 3.80 (a) BPM16-38 3.8 cm sq 16 by 16 strips Strip 2 6.00 2000 2.534 (a) Notes (a) HV loopback feature

Ionization Chamber Summary Specifications (continued) Device Insertion length (mm) Gas fill Water equivalent (e) thickness (um) Environment sensors? Desiccant? Materials in beam path IC128-25 44.0 (a) Atm or flow 180 Yes Yes Polyimide, Al 50.4 (b) Other features IC32-20 56.6 (a) Atm or flow 210 Yes Yes Polyimide, Al Compatible with IBA IC2/3 63.0 (b) IC64-16 44.0 (a) Atm or flow 195 Yes Yes Polyimide, Al 50.4 (b) IC16-5 32.0 (a) Atm or flow 150 Yes Yes Polyimide, Al IC1 application 37.0 (b) PX-3 14.6 (b) Atm or flow 100 Yes Yes Polyimide, Al IC1 application 24.0 (c) PX-1 32.0 (b) Atm 120 No No Polyimide, Al 36.6 (c) PX-2 32.0 (b) Atm 390 No No Polyimide, Al, 36.6 (c) FR4, Cu BPM16-38 34.2 (b) Atm or flow 1030 No No FR4, Cu, St.Stl Pneumatic actuator 152.4 (d) (0 if out) Vacuum housing Notes (b) Window to window (c) Face to face (d) Flange to flange Notes (e) Calculated equivalent proton energy degradation including all electrodes, windows and air gaps

Scanning Magnet Systems The scanning magnet system must allow the beam to reach any point in the scan field at the isocenter plane at the highest specified beam energy. It must move quickly between spot positions, occupy as little space as possible in the beam path, and must not significantly distort the beam shape. The matching scan amplifier system must be able to provide the current to maintain the beam spot precisely in position, then drive the magnet load to the next spot position at high slew rate with minimal settle time. The Pyramid MPM8-500 scan magnet system, together with the SX-500 amplifier, is a novel, patented solution to the beam scan requirement. The unique octopole structure allows the dipole magnet field to be rotated to any angle; in the standard configuration the maximum deflection angle is 6 degrees in any direction at proton energies up to 230 MeV. The result is a scanning magnet system that has no preferred axis, so the patient does not have to be rotated to align a physiological feature with the magnet scan direction. The dipole field quality is good, so the beam shape is maintained over the scan field. The complete magnet is 500 mm long, less than most conventional scan magnet solutions. A further exciting property of the octopole magnet, if eight individual amplifiers are connected, is the ability to alter the beam spot shape as fast as it moves from spot to spot. Future treatment planning systems can use this novel feature to improve conformal delivery of dose

Scanning Magnet Systems Scanning magnets often need to be designed to match a particular system, subject to constraints of space, weight, beamline optics, and of course the performance specification. Pyramid can offer a design service for scanning magnets and associated magnets such as fast focus quadrupoles. Static and transient analysis using the leading electromagnetic 3D modeling software, thirty years experience in mechanical design of electromagnets and a close working relationship with one of the world s most successful magnet manufacturers adds up to a fast and cost-effective design and manufacturing service.

Scan Amplifier Systems Pyramid controls can interface to all commercial scan amplifier systems. International Electric Company Oy of Helsinki has established a strong reputation in particle therapy. Pyramid has developed interfacing to two-channel IECO amplifiers which integrates inside the amplifier cabinet. The system is proven in use, and it includes redundant readback of the amplifier output current for added security during map execution. The Pyramid SX-500 is a compact water-cooled unit rated at 400A continuous, 400V. It is designed to match the MPM8-500 octopole magnet, but is also able to run a wide variety of other loads.

Helium Beam Path The particle beam must leave the vacuum line before it can be delivered to the patient. This may be through a small area vacuum window before the scanner, or a large area window after the scanner. There are advantages to using a small window. It can be made of thin material for low scattering, and window failure, should it occur, is more remote from the dosimetry ionization chambers and the patient. Pyramid has developed specially metalized polyimide window assemblies on standard CF and KF vacuum flanges that have negligible leak rate from permeation (< 1e-8 mbar l s-1). A helium-filled beam pipe takes the beam through the scanning system up to the final dosimetry and beam tracking ionization chambers. The scattering and energy degradation due to helium is less than one-fifth of that due to the same distance in air. The Pyramid helium beam path system comprises a transparent PVC flared beam pipe with replaceable thin polyimide windows. A mass-flow controller-based gas control system provides automatic control of flush and maintain input flow rates, and an oxygen sensor checks that helium has displaced all the air.

Electronics Solutions The Pyramid product range includes multi-channel electrometers for ionization chamber readout, interface units for scan magnet control and general applications and realtime controllers for map execution and interlocking. They can be used with Pyramid ionization chambers, magnet systems and other nozzle equipment, or with devices from other suppliers. Multichannel electrometers I3200 The most successful multi-channel electrometer on the market, with over three hundred units sold. Thirty-two parallel gated integrator channels. Dynamic range from 100 μa down to 100 fa. Multiple integration modes, external trigger input, precision internal calibration current source. External continuity test signal. Pneumatic actuator control output. HV bias output. PT applications: ionization chamber readout, profile grid readout, multilayer Faraday collector readout. I6400 Sixty-four parallel gated integrator channels plus separate dose plane input. Dynamic range from 100 μa down to 100 fa. Multiple integration modes, external trigger input, precision internal calibration current sources. Pneumatic actuator control output. I/O port for environmental sensors or other uses. HV bias output with loopback check. Full real-time controller capability including map execution, slave device control and interlocking. PT applications: ionization chamber readout, profile grid readout, multilayer Faraday collector readout, treatment map real-time processing. I128 One-hundred and twenty eight parallel integrator channels plus separate dose plane input. Dynamic range from 550 na down to 1 pa. Multiple integration modes, external trigger input, precision internal calibration current sources. Pneumatic actuator control output. I/O port for environmental sensors or other uses. HV bias output with loopback check. Full real-time controller capability including map execution, slave device control and interlocking. PT applications: ionization chamber readout, profile grid readout, multilayer Faraday collector readout. treatment map real-time processing.

Electronics Solutions F3200E Thirty-two parallel fast I-V converter channels. Dynamic range from 10 ma down to 100 pa. Time resolution down to 4 μsec. Multiple integration modes, external trigger input, precision internal calibration current source. Pneumatic actuator control output. HV bias output. PT applications: fast ionization chamber readout, profile grid readout. Other electrometers IC101 Single channel gated integrator. Dynamic range from 200 μa down to 1 pa. Multiple integration modes, external trigger input, precision internal calibration current source. HV bias output. PT applications: beam collector and beam stop readout. I400 Four channel gated integrator with biased inputs, Dynamic range from 100 μa down to 100 fa. Multiple integration modes, external trigger input, internal calibration current source. Pressure and temperature compensation inputs. PT applications: miniature ion chamber readout, quadrant BPM readout. F460 Four-channel current to voltage converter with four independently adjustable current ranges on each channel, 1 ma, 100 µa, 10 µa, 1 µa). Dynamic range 1 ma to 100 pa. 250 khz digitization. Precision internal calibration current sources. Optional bias high voltage output. Optional servo controller. PT applications: fast ion chamber readout, quadrant BPM readout, general fast current measurement.

Electronics Solutions Pulse counting C400 Four-channel detector controller, suitable for fast scintillation detectors. 150 MHz bandwidth window discriminators, 100 MHz counters, HV and pre-amp power supplies. Gate input and output, monitor outputs and encoder input. Automated pulse height distribution measurement. PT applications: beam loss monitor readout. Real-time controllers A560 Real time controller with ten fiber optic loop ports, each supporting up to fifteen slave devices. High throughput Ethernet interface supporting TCP/IP and UDP. Peer to peer connection capability. Built-in interlocking. PT applications: system integration, map execution and interlocking. A360 Cost-effective loop controller. Two fiber optic loop ports, each supporting up to fifteen slave devices. High throughput Ethernet interface supporting TCP/IP and UDP. PT applications: small system integration, servicing, development. Magnetic field measurement H20 Two-channel Hall probe system with high precision +/- 2.8T MFP-30 probe. Fast monitor analog outputs and field control option. PT applications: scan magnet field measurement, general beamline magnet measurement, field control for hysteresis compensation.

Electronics Solutions General I/O M10 General-purpose precision I/O interface. M10C version with programmable 20 ma current source. PT applications: accelerator current control, scan amplifier control, general magnet power supply control, helium supply control, general distributed control purposes. M40 General-purpose high-density precision I/O interface. PT applications: accelerator current control, scan amplifier control, general magnet power supply control including multiple channel supplies, general distributed control purposes. X32 Interface to two-channel IECO scan amplifier and LEM current sensors. PT applications: scan amplifier control. Other products HVI-4 Four-channel hardware comparator system for confirmation that high voltage bias is being delivered to an ionization chamber. Selectable threshold voltages. Safety relay outputs, and monitor port suitable for an M40. PT applications: ionization chamber interlocking. N2400 Twenty-four-channel actuator driver (suitable for 24 VDC solenoid-driven pneumatic actuators) with full front-panel manual override capability. PT applications: beamline automation.

Isocenter Diagnostics Pencil beam scanning raises needs for new approaches to commissioning and quality assurance. Pyramid isocenter diagnostics systems enable automated QA sequences, independent verification of scan geometry and rapid periodic calibration. The isocenter diagnostic systems are independent of the main therapy system so that they can make independent measurements, but can be interfaced to it, so that measurement sequences can be automated, saving time and resource. Pyramid diagnostics systems are configured using dual ionization chambers, beam stop charge collectors and motion stages. The ionization chambers give information on beam position, shape, trajectory and divergence for any spots in an irradiation pattern. The beam collector gives a measurement of charge in the spot that is qualitatively different from an ionization chamber measurement. The reading is independent of beam energy, atmospheric pressure and temperature. A multilayer Faraday collector can be specified in place of the beam collector, allowing independent validation of beam energy also.

Commissioning Software Reducing system commissioning time is key to the widespread adoption of particle therapy. The Pyramid ScanDose Diagnostic software allows all aspects of the dose delivery system to be exercised long before overall software commissioning is complete. The user can check all hardware and connections associated with dose delivery, all interlocks, communications with the accelerator, map parsing and execution. Complete records of all parameters measured and computer during map execution can be stored with 1 msec resolution. The graphical display of the pattern of spots in a layer shows the dose, placement and sequence of the map. As the map is executed the actual placement and dose is displayed. A difference display allows the user to quickly identify if any errors occur.

Treatment Control Interface Pyramid software systems have been carefully designed to be highly reconfigurable and easily integrated into customer control systems. Pyramid provides top quality software system integration services and in-house expertise that enables delivery of a low risk system based on proven modules. The scope of supply can include remote and on-site installation and commissioning. The software has been designed using component-based architecture and performs all aspects of pencil-beam scanning (Step-Shoot method) and provides several benefits: Communication interfaces using industry standards (RPC, DDS, etc.) Custom API to integrate into propriety control systems DICOM Ion Plan parser Conversion algorithms from DICOM to equipment units Complete diagnostics/ service GUIs In daily use for patient treatments worldwide

Pyramid Technical Consultants, Inc. 1050 Waltham Street Suite 200 Lexington MA 02421 USA www.ptcusa.com +1 781 402 1700 (US) +44 1273 492001 (UK) sales@ptcusa.com / support@ptcusa.com