LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Similar documents
LAUREL ELECTRONICS, INC.

SCALE & WEIGHT DISPLAYS

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

263 Series LED Bargraph Indicator and Controllers

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

DPM OWNERS MANUAL Website: Phone: (800)

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

TABLE OF CONTENTS. Instructions:

Process Transmitter RMA 422

Wall-/Pipe-Mount Level Indicator

DCP100 Digital Control Programmer Specifications

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

6-DIGIT FREQUENCY METER, TACHOMETER, RATE METER, TIMER, PULSE TOTALIZER, PROCESS METER & TOTALIZER WITH RS-232 PENTA P6000

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

SNAP Analog Input Modules. SNAP Analog Input Modules. Features. Description. Part Number

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Signal Stability Analyser

Pen and Multichannel Recorder: Digital Display

Process transmitter RMA422

MICRO SERIES COUNTERS & TIMERS LARGE DIGIT MODEL

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling!

2 MHz Lock-In Amplifier

AX 345. Process Indicator with Two Analogue Inputs, Calculations and Programmable Analogue Output. Operating Instructions for Model AX 346

DATA SHEET Panorama Rudder Indicator, TRI-2

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

High Performance Outdoor Test Translators

Hybrid Chart Recorder 250 mm (10")

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Multiple Band Outdoor Block Up- and Downconverters

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

Micro-DCI 53ML5100 Manual Loader

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

16-BIT LOAD CELL/DUAL STATUS INPUT

Set Point Controller OC557. Operator s Manual

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

DPR100 C/D Pen and Multichannel Recorder: Digital Display

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

AF-300 E11 Adjustable Frequency Drive

TempScan/1100 & MultiScan/1200

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

ProVu PD6000 Process Meter

4 MHz Lock-In Amplifier

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

CERTIFICATE of EU TYPE-EXAMINATION

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

OPTICAL POWER METER WITH SMART DETECTOR HEAD

MT32 Telemetry Multi channel telemetry system for rotating application

Preset counters, electronic

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Part-Turn Electric Multi-Turn Electric

VIDEO MATRIX SWITCHES HDMI 2.0

X-Band Redundant LNB Systems

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

medlab One Channel ECG OEM Module EG 01000

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

02/11/2015

CLOCKAUDIO. MR88 Automatic Microphone Mixer. Version 4.2

Calibration of U127 series weight indicators. Date: B (9)

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

Photoelectric Sensors E3F2

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

FOM-9010, FOM-9011 and FOM-9012

SIL-2 8-Ch Analog Input Series Thermocouple, High Level, Low Level

Satellite Up- and Downconverter Indoor / Outdoor

SY-MS121 SY-MS121-AP

Ku-Band Redundant LNB Systems

Advanced Test Equipment Rentals ATEC (2832)

C-Band Redundant LNB Systems

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Modular Lube Lubrication Systems System Controls

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

HOBO H Energy Logger

Amplifier Systems. 1:1, Dual 1:1 and 1:2 Redundant Low-Noise. Back to

Operating instructions Electronic preset counter Type series 717

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

DUAL/QUAD DISPLAY CONTROLLER Operation Manual

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors DATA SHEET

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Sensopress LCD Special English

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

Transcription:

Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999 Selectable fixed right-hand zero with rounding Isolated 10 Vdc supply to power up to four 350-ohm load cells in parallel 4- or 6-wire hookup to avoid lead resistance effects 1 Gohm input impedance Up to 60 conversions per second Peak or valley display Auto-tare with tare value stored in memory Universal AC power, 85-264 Vac 1/8 DIN case sealed to NEMA-4X from front panel Optional serial I/O: Ethernet, USB, RS232, RS485, Ethernet-to-RS485 converter Optional relay output: dual or quad relays, contact or solid state Optional isolated analog output: 4-20 ma, 0-20 ma, 0-10V, -10 to +10V Optional low voltage power: 10-48 Vdc or 12-32 Vac The Laureate load cell & microvolt meter is a highsensitivity monitor and controller for use with load cells, strain gauges and microvolt input signals where high accuracy and stability are required. DC microvoltmeter operation provides sensitivity down to ±20 mv full scale with 1 µv resolution. A display span of 99,999 counts with sensitivity of 0.2 µv per count can be obtained by applying a digital multiplier of five. A moving average digital filter assures quiet readings in electrically noisy environments. Load cell operation allows six-wire hookup and scaling for direct readout in engineering units, such as pounds, kilograms or PSI. Scaling can be via front panel pushbuttons or a computer. Zero may be set from -99,999 to +99,999. Range may be scaled from 0 to ±99,999. Digital scaling and calibration eliminate drift caused by potentiometers in nonmicrocomputer based meters. Meter accuracy is 0.01% of full scale ± 2 counts with an ideal load cell. Custom curve linearization, which is available with the optional Extended main board, can extend the working range of real-world load cells. Custom curve linearization also allows high accuracy to be achieved with lower cost, less linear load cells. A built-in isolated 10 Vdc excitation supply can provide up to 120 ma of current at 10V to power four 350-ohm load cells in parallel. The meter operates in a ratiometric mode to eliminate errors due to supply variations. When excitation sense inputs are used in 6-wire connection, the meter compensates for variation in resistance of the transducer leads to allow long cable runs. High read rates at up to 60 or 50 conversions per second while integrating the signal over a full power cycle are provided by Concurrent Slope (US Pat 5,262,780) analog-to-digital conversion. High read rates are ideal for peak or valley capture, realtime computer interface, and control. Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or control signal at the rear connector, or be transmitted as serial data. Digital filtering is selectable for electrically noisy environments, including a batch averaging filter and an adaptive moving average filter which provides a choice of 8 time constants from 80 ms to 9.6 s. When a significant change in signal level occurs, that filter adapts by briefly switching to the shortest time constant to follow the change, then reverts back to the selected time constant. In a selectable Auto filter mode, the filter time constant is automatically selected based on detected signal noise. Easy scale and offset are provided by Laureate DC, process and load cell meters by either of two selectable methods: With the coordinate reading method, the meter reads the high and low signal values, and the user enters the desired high and low reading values. The meter then calculates the span multiplier and offset. This method is ideal if an external calibration reference is available. With the manual coordinate method, the user enters the high and low input values in Volts plus the desired high and low reading values. This method is suitable if no external calibration reference is available. Auto-tare is standard for weighing applications to subtract the weight of an empty container and may be controlled by an external pushbutton contact closure or a logic signal. Additional capabilities for weighing applications are provided by the Laureate weight & scale meter. Designed for system use. Optional plug-in boards include Ethernet and other serial communication boards, dual or quad relay boards, and an isolated analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with red or green LEDs. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A builtin isolated 5, 10, or 24 Vdc excitation supply can power transducers and eliminate the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs. LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 1

Specifications DC Microvolt Input Input Range, mv Resolution Input Resistance Error at 25 C Load Cell Input ±20.000 ±50.000 ±100.00 ±250.00 ±500.00 1 µv 1 µv 10 µv 10 µv 10 µv 1 GΩ 0.01% FS ± 2 counts Full-Scale Input, mv Zero Adjust Span Adjust Input Resistance Error at 25 C ±20.000 ±50.000 ±100.00 ±250.00 ±500.00 DC Microvolts & Load Cell -99,999 to +99,999 0 to ±99,999 1 GΩ 0.01% FS ± 2 counts Accuracy Error at 25 C Span tempco Zero tempco Load cell linearization Noise Rejection CMR, DC to 60 Hz NMR at 50/60 Hz A-to-D Conversion Technique A-to-D rate Output update rate Display update rate Display Readout Range Indicators Power Voltage, standard Voltage, optional Frequency Power isolation Excitation Output (standard) Selectable levels Output isolation Analog Output (optional) Output Levels Current compliance Voltage compliance Scaling Resolution Isolation Relay Outputs (optional) Relay types Current ratings Output common Isolation 0.01% FS ± 2 counts 0.0015% of reading/ C 0.1 µv/ C Provided by Extended meter version 130 db 90 db with min filtering Concurrent Slope (Pat 5,262,780) 60/s at 60 Hz, 50/s at 50 Hz 56/s at 60 Hz, 47/s at 50 Hz 3.5/s at 60 Hz, 3/s at 50 Hz 5 LED digits, 7-segment, 14.2 mm (.56"), red or green. -99999 to 99999 or -99990 to 99990 (count by 10) Minus sign, 2 red LED lamps 85-264 Vac or 90-300 Vdc (DC operation not UL approved) 12-32 Vac or 10-48 Vdc DC or 47-63 Hz 5 Vdc ± 5%, 100 ma; 10 Vdc ± 5%, 120 ma; 24 Vdc ± 5%, 50 ma 50 Vdc to meter ground 4-20 ma, 0-20 ma, 0-10V, -10 to +10V (jumper selectable) 2 ma at 10V ( > 5 kohm load) 12V at 20 ma ( < 600 Ohm load) Zero and full scale adjustable from -99999 to +99999 16 bits (0.0015% of full scale) 2 Form C contact relays or 4 Form A contact relays (NO), 2 or 4 Form A, AC/DC solid state relays (NO) 8A at 250 Vac or 24 Vdc for contact relays 120 ma at 140 Vac or 180 Vdc for solid state relays Isolated commons for dual relays or each pair of quad relays LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 2

Serial Data I/O (optional) Board selections Protocols Data rates Digital addresses Isolation Signal Connections Ethernet, Ethernet-to-RS485 server, USB, USB-to-RS485 server, RS485 (dual RJ11), RS485 Modbus (dual RJ45), RS232. Modbus RTU, Modbus ASCII, Laurel ASCII protocol 300 to 19200 baud 247 (Modbus), 31 (Laurel ASCII), Environmental Operating temperature Storage temperature Relative humidity Protection 0 C to 55 C -40 C to 85 C 95% at 40 C, non-condensing NEMA-4X (IP-65) when panel mounted Load Cell Meter Connections In 4-wire connection, the excitation and sense lines are tied together. The meter can make ratiometric corrections for supply voltage variations, but not compensate for variations in lead resistance. This connection is often used with short cable runs. In 6-wire connection, the sense lines are separate from the excitation lines, thereby eliminating effects due to variations in lead resistance. This allows long cable runs in outdoor environments with temperature extremes. For large scales, up to four 350 ohm load cells can be powered by a single Laureate, whose excitation output is rated 120 ma at 10 V. The excitation and sense points of the four bridges are connected in parallel through a summing box. LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 3

Seat belt tensile strength testing using Laureate digital panel meters. The three meters display Force, Displacement and Speed. Sample Applications Auto-Tare To read the net weight of an object, the empty container is first weighed, and an external button is pushed to zero out the display. The meter will then read net weight when an object is added to the empty container. The tare value is stored in memory for subsequent readings. Determining Volume Using Load Cells An easy way to determine volume of an irregularly shaped tank with no need for linearizing is to weigh the tank using load cells. The meter will automatic- ally tare out the weight of the empty tank and then scale the load cell signals to units of volume, such as liters or gallons. Peak Capture for Tensile Strength of Wire Peak readings are automatically captured at rates up to 60 per second, while the display updates at a legible 3.5 per second. The peak reading can be recalled at the push of a button or be always displayed. It can also be transmitted to a computer via RS232, RS485., USB, or Ethernet. LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 4

Mechanical LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 5

Ordering Guide Create a model a model number in this format: L10000WM, IPC DPM Type Main Board L Laureate Digital Panel Meter 1 Standard Main Board, Green LEDs 2 Standard Main Board, Red LEDs 3 Extended Main Board, Green LEDs 4 Extended Main Board, Red LEDs Note: Extended capability is only required for custom curve linearization or for display of time rate of change, such as flow rate from changing tank weight. Power Relay Output Analog Output Digital Interface Signal Input 0 85-264 Vac 1 12-32 Vac or 10-48 Vdc 0 None 1 Two 8A Contact Relays 2 Two 120 ma Solid State Relays 3 Four 8A Contact Relays 4 Four120 ma Solid State Relays 0 None 1 Isolated 4-20 ma, 0-20 ma, 0-10 V, -10 to +10V 0 None 1 RS232 2 RS485 (dual RJ11 connectors) 4 RS485 Modbus (dual RJ45 connectors) 5 USB 6 USB-to-RS485 device server 7 Ethernet 8 Ethernet-to-RS485 device server Load Cell (6-wire ratio) WM Field Scalable. Default scaling is 0-20 mv = 0-100.00 WM1 Custom Scaling. In the write-in field of your order, specify min input, min reading; max input, max reading. Full-scale input is 20-500 mv. Excitation is 10 V for up to four 350-ohm load cells. Add-on Options BL Blank Lens without Button Pads CBL01 RJ11-to-DB9 Cable CBL02 USB-to-DB9 Adapter CBL05 USB Cable, A to B IPC Splash-proof Cover BOX1 NEMA-4 Enclosure BOX2 NEMA-4 Enclosure plus IPC LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 6