Pin setup: 1 (EXC+) 2 (EXC-) 3 (SIG+) 4 (SIG-) Pin setup: 2 (TXD) 3 (RXD) 5 (GND) others (NC)

Similar documents
OMEGA SERIES COUNTING SCALE

Weighing Scale. 10key&12key User manual

TABLE OF CONTENTS. Instructions:

COMPLETE MANUAL For Personal Scale AV-200-EC-P Baby Scale AV-20-EC Chair Weigher VEH-200-EC.

Manual Weightbridge PCE-EP Series

QUICK COUNT /EASY COUNT TECHNICIAN S GUIDE. (C) Copyright 1992 Setra Systems, Inc. All rights reserved

Twin Beam Scale Operation Manual. April Specialists in Industrial Weighing

5024 WEIGHING TERMINAL

OPERATION MANUAL MODEL DF3000 DIGITAL WEIGHT INDICATOR REVISION A-1

Agilent FieldFox RF Analyzer N9912A

Operators Manual. TeleWeigh Wired. Model: by Fairbanks Scales, Inc All rights reserved Revision 1 09/07

ET-REMOTE DISTANCE. Manual of ET-REMOTE DISTANCE

Version 1.3. Table of contents

OPERATION MANUAL OF MULTIHEAD WEIGHER

Ranger Simplifying Even the Most Complex Industrial Applications. Compact Bench Scales. Standard Features Include:

WEIGHING INDICATOR SERIE IPE 50

Sample BD Tech Concepts LLC

Keysight FieldFox Microwave Analyzers

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Hardware & software Specifications

T UNITS Appendix II Setup Functions PRINT FORMAT FORMATTING MINIMUM SAMPLE SIZE FORMATTING MINIMUM ACCURACY...

Service Manual. Eclipse Scale Series. Model: PPI-HR5000 HR by Fairbanks Scales Inc. All rights reserved. Issue #8 7/03

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

DiD. LCD Video Monitor & Video Wall Universal User Manual. Digital Information Display

Signal Stability Analyser

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

JLC-BB150 JLC-BB200 JLC-BB300 JLC-BB500 JLC-BB600 JLC-BB1200

Installation and User Manual version WDOS-S Unload 2014/30/EU EN55022:2010 EN :2005 EN :2007 SYSTEM IDENTIFICATION

SWS-PS Series Parcel Scale

Quick Start Operating Instructions

ST-4000 SIGNAL LEVEL METER

TRIMBLE GPS / 10MHz REFERENCE MONITOR DISPLAY V January 2015

Ford AMS Test Bench Operating Instructions

ST-4000D SIGNAL LEVEL METER

Instruction manual for 5024 Weighing Terminal

FRQM-2 Frequency Counter & RF Multimeter

Installation and User Manual version 1.00 WDESK-G WINOX-G/2G. Load 2014/30/EU EN55022:2010 EN :2005 EN :2007 SYSTEM IDENTIFICATION

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Installation and User Manual version WDOS-C Load 2014/30/EU EN55022:2010 EN :2005 EN :2007 SYSTEM IDENTIFICATION

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

RS232 Connection. Graphic LCD Screen. Power Button. Charger Adapter Input LNB Output. MagicFINDER Digital SatLock Operating Manual

Sample BD Tech Concepts LLC

AP30 MkII Postal Scale TECHNICAL MANUAL

Visit to see the full line of Ohaus Balances. Valor 3000 Series Instruction Manual. Serie Valor 3000 Manual de instrucciones

Quick Operation Guide of LTN7700/7600 Series NVR

Ford AMS Test Bench Operating Instructions

Service Manual. NexWeigh. Weight Instrument by Fairbanks Scales, Inc. Revision 3 03/10 All rights reserved

Operator s Manual. Ultegra. Health Scale. Fairbanks Scales by Fairbanks Scales Inc. All rights reserved. Revision 5 06/07

Ezecal MK3 User Manual

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

INT-X-P and INT-X-L Programming instructions

Agilent Technologies. N5106A PXB MIMO Receiver Tester. Error Messages. Agilent Technologies

(B) EL BACK LIGHT Press button S1 for EL back light with 3 seconds auto light up. (C) BASIC OPERATION OF BUTTONS

Omni Ultimate Quick Start Guide. 120V AC or 230V AC.

Operating Instructions ACX-Series Digital Aircraft Cable Tension Meter

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

DPM 942-FPSI 4-20mA Loop Meter with Programmable Backlighting

2070 PROFINET MODULE

Digital Compass. Package Contents. Hardware Overview. Basic Operation. Article: CNS-DC3 Quick Guide v1.0

SCALE & WEIGHT DISPLAYS

Model IQ4-PC User Manual Revision Date:

Service and Technical Support PLEASE CONTACT YOUR NEAREST DISTRIBUTOR If unknown then fax: 44 (0)

Noise Detector ND-1 Operating Manual

4X50 ETHERNET SYSTEM

LAUREL ELECTRONICS, INC.

POL-200 Semiautomatic Polarimeter. Instruction Manual BANTE INSTRUMENTS CO., LTD

ZIRCONIA OXYGEN ANALYZER CONVERTER

PMED 操作手冊 User s Manual

LCD display module. graphic 61x16 dots

D R M A X - 2 DDS FREQUENCY SYNTHESIZED DRM MW TRANSMITTER. User s Guide (Please read carefully before using for the first time!)

Intelligent Security and Fire Ltd

CARLO GAVAZZI Automation Components

Digital Video Wall Control Box

EN Wireless programmable thermostat

4x50 User s guide Modbus TCP

Show Designer 3. Software Revision 1.15

4X70 PROFINET SYSTEM

Operating Instructions BTX-1 Series Digital Band Tension Meter

Ambient NOx monitor APNA-370 Operation Manual CODE:GZ D

2x50 ETHERNET MODULE

10MHz Source/Inserter

LG Digital Signage *MFL * Easy Setup Guide (MONITOR SIGNAGE)

Absolute volume control is also possible with SP Controls option Audio Follow Video Preamplifer.

USER & ENGINEER INSTRUCTION MANUAL

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6.

Globalmediapro SMR-650

DGC-1000A CLAMP-ON GROUND RESISTANCE TESTER

Engineer Spec of LK-VT-W22ONDW

LCD display module. graphic 122x32 dots

ZU 252. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface

DINOX&Digital&Video&Recorder&

Ambient NH 3 monitor APNA-370 Instruction Manual CODE:GZ

OTS-300 Express Series Power Meters/Sources and Testers

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

BLUNIK II ACCESSORIES SPORT DRIVE SPORT CALCULATOR... 49

Quick-Start for READ30

Kramer Electronics, Ltd. USER MANUAL. Model: 900xl. Power Amplifier

User's Manual. CFM/CMM Thermo Anemometer 94204

Transcription:

Load Cell connection (Male) Pin setup: 1 (EXC+) 2 (EXC-) 3 (SIG+) 4 (SIG-) RS232C Connection: DB-09 (Male) Pin setup: 2 (TXD) 3 (RXD) 5 (GND) others (NC) Bi-directional RS232C Setting Baud Rate The ADC Series scale supports RS 232 configuration is 9600-8-N-1. Print out format (weight string) STA SIGN W 5 W 4 W 3 W 2 W 1 W 0 U 1 U 0 CR LF STA: U (55h) indicates it s an unstable weight. S (53h) indicates it s a stable weight. SIGN: - (2Dh) means it s a negative weight. (20h) space char indicates it s a positive or zero weight. W 5 W 0 : Weight data, decimal point included. U 1, U 0 : K (4Bh) g (67h) indicates that the Unit is kilo-gram. CR: 0Dh LF: 0Ah Command print out COMMAND Actions Response <ENQ> (05h) the weight string CS<CR><LF> Clear Sample. W<CR><LF> PW<CR><LF> PCS<CR><LF> the weight string Piece weight(xxxx.xxxuu<cr><lf>) Pieces (xxxxxxx<cr><lf>) T<CR><LF> Txxx<CR><LF> Tare operation. Preset tare given weigh=xxx (g) 19

Precise Counting Scale ADC User Manual SNOWREX INTERNATIONAL CO., LTD. SRADC20080729

Table of Contents Specifications... 2 Basic specification... 2 Series specification... 2 Display and keypad... 3 LCD Display... 3 Keypad... 4 Sampling operation... 6 Setup piece weight by direct keypad input... 6 Setup piece weight by sampling, method 1... 6 Setup piece weight by sampling, method 2... 6 Setup piece weight by sampling, method 3... 7 Setup piece weight by sampling, method 4... 7 Auto re-sample operation... 7 PLU operation... 8 PLU Data setting... 8 Loading PLU... 9 Modify PLU... 9 Operation of ADD... 10 Operation of MR... 10 PLU & ACC Mode Description...11 More operations... 12 Alarm function... 12 Input Tare weight by keypad... 12 Notes on B scale(external load cell)... 13 Settings and Calibration... 13 General setting (CAL 1)... 13 External Load Cell setting (CAL 2)... 15 Calibration Procedure (CAL 3)... 16 Linearity Calibration Procedure (CAL 4)... 17 Load Cell connection (Male)... 19 RS232C Connection: DB-09 (Male)... 19 Bi-directional RS232C Setting... 19 1

2. Calibration by 1/3 of the maximum capacity XXXXX The first row shows AD Value, the second row shows the 2000 weight of 1/3 of the maximum (Unit: gram), and the third Pnt 1 row shows Pnt 1. Put on poise of the 1/3 weight by the maximum capacity. Wait until the AD value becomes stable, press key to go to the next step. 3. Calibration by 2/3 of the maximum capacity XXXXX The first row shows AD Value, the second row shows the 4000 weight of 2/3 of the maximum (Unit: gram), and the third Pnt 2 row shows Pnt 2. Put on poise of the 2/3 weight by the maximum capacity. Wait until the AD value becomes stable, press key to go to the next step. 4. Calibration by the maximum capacity XXXXX The first row shows AD Value, the second row shows the 6000 maximum weight (Unit: gram), and the third row shows Pnt Pnt 3 3. Put on poise of full capacity of the scale. Wait until the AD value becomes stable, press key to enter next step. Take off poise from pan, and the instrument will restart automatically. 18

3. Setup A scale stable control level StAbLE Setup the stable control level. XXX X: stable control level 1~10 1-10 Default is 5 4. Zero Point Calibration Display XXXXX 0 Pnt. 0 Explanation The first row shows AD Value, the second row shows 0, and the third row shows Pnt. 0 Make sure the weighing pan is empty. Wait until the AD value becomes stable, press key to go to the next step. 5. Setup calibration weight The first row shows AD Value, the second row is the XXXXX calibration weight (Unit: gram), and the third row shows XXXX Pnt.CAL Pnt.CAL The default calibration weight is 1/3 of scale capacity. Use the number keys to change the desired calibration weight. Put on poise of the calibration weight. Use the number keys to input the calibration weight in gram. Wait until the AD value becomes stable, press key and the calibration is done. Linearity Calibration Procedure (CAL 4) Note: This section can only be operated by engineers. Please have the jumper JP3 switch OFF before you start the calibration process. In Calibration menu, press to toggle among the menu options, and to confirm. 1. Zero Point Calibration Display XXXXX 0 Pnt 0 Explanation The first row shows AD Value, the second row shows 0, and the third row shows Pnt 0. Make sure the weighing pan is empty. Wait until the AD value becomes stable, press key to go to the next step. 17

Specifications Basic specification Digital Display LCD, height 14.5mm 6/7/7(Weight/Piece Weight/ Total Pieces) Platter Size(mm) 245 x 355 (W x H) Dimensions(mm) 387x365x117(W x L x H) Net Weight(kg) 4.5kg(with pillar); 3.7kg(without pillar) Operating Temperature 0 to +40 Relative Humidity Less than 85% Power 9V / 500mA, AC adapter; Built in 6V Rechargeable Battery Interface RS-232C 9600-8-N-1 Series specification Model ADC-6 ADC-15 ADC-30 Capacity = 6kg 15kg 30kg Min = 20g 40g 100g e = 0.2g 0.5g 1g Accuracy 1/30000 1/30000 1/30000 2

Display and keypad LCD Display First row displays the Weight. Second row of digits displays the Piece Weight. Also used as keypad input indication. The third row of digits displays the Piece Counts (shorten as PCS). Indicates the battery power is low. A recharge/replace is required for further operation. Indicates the first row displays the Tare-ed weight. Indicates the weigh is stable. Indicates the weight is at zero. Displays the PLU number. Displays the accumulated counting in memory. Indicates that the upper bound of piece counts or weight is set. 3

0 b.pnt. 0 and the third row shows b.pnt. 0 Make sure the weighing pan is empty. Wait until the AD value becomes stable, press key to go to the next step. 5. Setup calibration weight The first row shows AD Value, the second row is the XXXXX calibration weight (Unit: gram), and the third row shows XXXX b.pnt.cal b.pnt.cal The default calibration weight is 1000g. Use the number keys to change the desired calibration weight. Put on poise of the calibration weight. Use the number keys to input the calibration weight in gram. Wait until the AD value becomes stable, press key to go to the next step. Calibration Procedure (CAL 3) Please remove the JP3 jumper before you start the calibration process. In Calibration menu, press to toggle among the menu options, and to confirm. 1. SEL maximum capacity Display LoAd 06 LoAd 15 LoAd 30 2. Zero tracking Display trace off trace on Maximum Capacity 6 kg 15 kg 30 kg Explanation Zero tracking disable Zero tracking enable 16

6. LO BEEP setting Display Lo.bEEP ALArn off Lo.bEEP ALArn Short Lo.bEEP ALArn LoNG Explanation Disable LO alarm sound. Set LO alarm sound as chain short beep sounds. Set LO alarm sound as chain long beep sounds. External Load Cell setting (CAL 2) During the exchange rate setting procedure, press to switch selection, and press to accept setting. 1. Setup B scale capacity b.load xxxxxxxx Setup the capacity of B scale by gram. If input 0 here, B scale will be disabled. GrAN 2. Setup B scale interval b.d= xxxxxxxx GrAN Setup the scale interval (d) of B scale by gram. Min. d is 1 gram. Max. d is 65535 gram. 3. Setup B scale stable control level b.stabl x Setup the stable control level. X: stable control level 1~10 Minimal level is 1. Level 1 allows the fastest stabilize time, but resulted in lowest noise filter. Max level is 9, allows best noise filter, but resulted in slowest stabilize time. Default stable level is 3. 4. Zero Point Calibration XXXXX The first row shows AD Value, the second row shows 0, 15

Indicates that the lower bound of piece counts or weight is set. Indicates the weighing is at A scale (main scale) or B scale (external Load Cell). Both and indicators Keypad Switch scale OFF. Switch scale ON. Zero operation Tare operation ~ numerical keypad Clear. For alarm control function. Accumulate piece counting. Recall total piece counting accumulated. For saving/loading/modifying preset piece weights. 4

Piece weight direct input. (see piece weight setup chapter for more detail) Sample key: multiple sample methods are available. See the sampling chapter for more details. Switch between A scale (main scale) and B scale(external scale). Display net weight, tare weight, and gross weight all together. Press to load preset piece weights. 5

Aut.oFF 20 Aut.oFF 30 2. BL Backlight setting Display b.light off b.light on b.light AUto If no operation, shut down the scale in 20 minutes. If no operation, shut down the scale in 30 minutes. Explanation Disable the backlight function. Enable the backlight function. Automatic backlight 3. Repeat Tare operation ON/OFF re.tare Disable repeat Tare operation off re.tare Enable repeat Tare operation on 4. Auto re-sample ON/OFF re.sanp Disable auto re-sample operation off re.sanp Enable auto re-sample operation on 5. HI BEEP setting Hi.bEEP Disable HI alarm sound. ALArn off Hi.bEEP Set HI alarm sound as chain short beep sounds. ALArn Short Hi.bEEP Set HI alarm sound as chain long beep sounds. ALArn LoNG 14

Notes on B scale(external load cell) 1. button is used to switch A(main) scale and B(external) load cell. 2. The initial zero is the zero setup in calibration procedure. It means any loads on the weighing pan will exactly displayed after the scale start. 3. Zeroing range is 10% of capacity. Settings and Calibration 1. Press and hold any key while turning the scale ON. It will show CAL 1 on the LCD display. 2. Press key to toggle among the CAL 1, CAL 2, CAL 3, and CAL 4 menus. 3. Select CAL 1, press key to enter General setting menu. 4. Select CAL 2, press key to enter the External Load Cell (B scale) setting menu. 5. Select CAL 3, press key to enter Calibration procedure. 6. Select CAL 4, press key to enter Linearity Calibration menu. Note: To perform CAL 3/CAL 4 calibration, you must remove the JP3 jumper from the PCB first. Put the JP3 back after calibration is complete.. General setting (CAL 1) In the general setting menu, press key to toggle between the options, and key to confirm. 1. Aut.oFF Auto shutdown setting Aut.oFF Disable shutdown function. off Aut.oFF If no operation, shut down the scale in 5 minutes. 5 Aut.oFF If no operation, shut down the scale in 10 minutes. 10 13

Sampling operation Setup piece weight by direct keypad input 1. In weighing mode, press the white number keys on the right side to input the piece weight. The unit is in gram instead of kilo-gram. 2. Then, press button, and the piece weight has been changed. 3. The number input will be cleared after 4 seconds if is not been pressed. Setup piece weight by sampling, method 1 1. Put certain pieces of objects on to the scale pan. 2. In weighing mode, press the white number keys on the right side to input the piece count. 3. Press and the piece weight will be calculated accordingly. 4. The number input will be cleared after 4 seconds if is not been pressed. Setup piece weight by sampling, method 2 1. Make sure the piece weight is empty. 2. Press, the second row of LCD shows and the third row of LCD shows 100. 3. If the piece count 100 is not desired, press the white number keys on the right side to change it. 4. Then, put the objects of desired piece counts on to the weighing pan. 5. The sampling will be calculated automatically. Note: If the weighing is on B scale (external), after job will be continued on A scale automatically. is pressed, the sampling 6

Setup piece weight by sampling, method 3 1. Make sure the piece weight is empty. And there are certain objects on the weighing pan. 2. Press, the second row of LCD shows and the third row of LCD shows 100. 3. If the piece count 100 is not desired, press the white number keys on the right side to change it. 4. Then, remove the objects by desired piece counts on to the weighing pan. 5. The sampling will be calculated automatically. Note: If the weighing is on B scale (external), after is pressed, the sampling job will be continued on A scale automatically. Setup piece weight by sampling, method 4 If the piece weight is not empty, press and the piece weight will be re-calculated. Auto re-sample operation After a successful sampling operation, the scale will automatically sample again on the A scale for any new small weight. Either put on new weight or take off weight from the weighing pan will automatically sample again. Auto re-sample function can be set off during configuration. 7

More operations Alarm function 1. Press. The PCS column displays 2. The piece weight column shows the PCS Upper Bound setting. Use the white keys to change. 3. Press again. Now the PCS column is. This is PCS Lower Bound setup. 4. Press again. Now the PCS column is. This is Weight Lower Bound setup. The unit is by gram instead of kilo-gram. 5. Press again. Now the PCS column is. This is Weight Lower Bound setup. The unit is by gram instead of kilo-gram. 6. Press again. And the scale back to normal weighing mode. And the Alarm function is ready to work. 7. While the pieces exceeds the upper bound of PCS Upper Bound, or lower than the PCS Lower Bound and is not zero, the scale will beeps for warning. 8. While the weights exceeds the upper bound of Weight Upper Bound, or lower than the Weight Lower Bound and is not zero, the scale will beeps for warning. Input Tare weight by keypad 1. In weighing mode, press the white number keys on the right side to input the Tare weight. The unit is by gram instead of kilo-gram. 2. Then, press button, and the Tare weight has been changed. 3. The number input will be cleared after 4 seconds if is not been pressed. Note: It s not allowed to set Tare weight greater than scale capacity. 12

PLU & ACC Mode Description Appearance Mode Description Neither nor light up or flash Weighing Mode Able to input piece weight or change to any other modes. light up, not flash. PLU preset piece weight indication PLU setting is completed. flashing PLU setting mode 1 During PLU setting, input the PLU number to be saved and press to finish. 1. light up, no flash. 2. The number below PLU keep flashing. Loading PLU mode During PLU reading, input the PLU number, and press to load the desired PLU. light up, no flash. Numbers in weight column. ACC accumulation indication Several sets of data have been saved. Press to enter Total PCS display mode. 1. light up, no flash. 2. The weight column is empty. 3. The piece weight column shows Total PCS display mode The number above ACC is the set of data. No weighing function at this moment. Total PCS column is the pieces summation of all the data. Press key to clear all data. Press to return to weighing mode. 11

PLU operation PLU Data setting Steps in setting PLU no. 1~24 1. Setup piece weight according to previous chapter. 2. Press key, and you should see the flashing. 3. Press the left number keys to select PLU number 4. Press key to save your setting. The PLU will stop flashing. Example: 1. Press, to enter piece weight as 0.5 gram. 2. Press key, now is flashing on LCD. 3. Press key, PLU digits shows 3, and now flashing. 4. Press key again, PLU digits shows 15 instead, and flashing. 5. Press key, after the beep, the piece weight for PLU 15 is done and set as 0.5 gram. Steps in setting PLU no.0~999 1. Setup piece weight according to previous chapter. 2. Press and you will see PLU flash on LCD. 3. Press the white number key to select PLU number. 4. Press to save your setting, PLU stop flashing on LCD. If the input isn t completed in 30 seconds, the setting will be suspended and back to normal weighing mode. 8

Loading PLU Steps in loading PLU no.1-32 In weighing mode, press any key from the left 16 number keys to access the PLU memory of the key s lower-right set at once. Press the same key again to access the PLU memory of the key s upper-left set. Example: 1. Press one time, the 3 th PLU is loaded. The LCD shows 3 below the PLU indicator. 2. Press again, the 15 th PLU memory is loaded. The LCD shows 15 below the PLU indicator. Steps in loading PLU no.0-999 1. In weighing mode, press and hold key until it emits a double beep then release key. 2. Use the white number keys to input the desired PLU number. 3. Press key again, and the reference PLU is loaded. Modify PLU 1. When the PLU indicator is shown on the display, press key and you will see the piece weight flashing. 2. Setup piece weight according to previous chapter. 3. Press to save your settings. The piece weight no longer flashing, and the new piece weight is updated. 9

Operation of ADD 1. When there is a load on the weighing pan and piece weight has been input, press key and after a beep sound, recorded. will light up on the LCD, indicating a data has been 2. Clear the load on the weighing pan and put another load on the weighing pan. Input the piece weight and then press key. After a beep sound, will light up on the LCD, indicating second data has been recorded. 3. After each recording, if the load on the weighing pan is not cleared, pressing will result in the long beep and the scale won t be able to record the next one. 4. The stored memory can memorize up to 199 weighing results. Operation of MR 1. In weighing mode, press key and the Weight column will be cleared. The Piece Weight column shows. The PCS column shows the total piece number of all memories. The number shown above the ACC indicates the number of weighing results stored. 2. Pressing will clear all the data in memory. 3. Pressing key will quit this mode without clearing the recorded data. 10