A Modified Protocol for Color Vision Screening Using Ishihara

Similar documents
M. Marechal, M. Delbarre, J. Tesson, C. Lacambre, F. Froussart-Maille Percy Military Hospital, Clamart, FRANCE

VISUAL MILL LAB. SECTION 1: Complete the following tests and fill out the appropriate sections on your Visual Mill Color Deficit Worksheet.

ROY G BIV COLOR VISION EXPLORED

Historically, the development of colour vision tests

City, University of London Institutional Repository

JOURNAL OF PHARMACEUTICAL RESEARCH AND EDUCATION AUTHOR GUIDELINES

620 Rejwrts Investigative Ophthalmology

Guide to contributors. 1. Aims and Scope

Characterization and improvement of unpatterned wafer defect review on SEMs

Manuscript Submission Guidelines

Monitor QA Management i model

Astigmatic axis and amblyopia in childhood

Manuscript Submission Guidelines

Understanding PQR, DMOS, and PSNR Measurements

Predicting of Uncorrected Astigmatism from Decimal Visual Acuity in Spherical Equivalent

Guidelines for Manuscript Preparation for Advanced Biomedical Engineering

Everything You Wanted to Know About Color Vision

Astigmatism in Children: Changes in Axis and Amount from Birth to Six Years

NAA ENHANCING THE QUALITY OF MARKING PROJECT: THE EFFECT OF SAMPLE SIZE ON INCREASED PRECISION IN DETECTING ERRANT MARKING

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

NOTIFICATION OF A PROPOSAL TO ISSUE A CERTIFICATION MEMORANDUM

AMD+ Testing Report. Compiled for Ultracomms 20th July Page 1

User s Manual Color Vision Recorder version 4

INTRODUCTION TO GRAPHICS. Color Vision Simulator Examples

APP USE USER MANUAL 2017 VERSION BASED ON WAVE TRACKING TECHNIQUE

This set of slides were used by Professor Cole in his talk on the occasion of the 60th anniversary of CIE Australia.

Computer-Guided Harness Assembly

Official Journal of the European Union L 82/3 DECISIONS COMMISSION

Viewers and Voters: Attitudes to television coverage of the 2005 General Election

Prevalence of Color Vision defects (CVD) Among Adult Human Population of District Gilgit, Gilgit-Baltistan, Pakistan.

UNDERSTANDING TINNITUS AND TINNITUS TREATMENTS

Optometry in Practice The continuing professional development journal of the College of Optometrists

1. General principles for injection of beam into the LHC

Mental Health Status and Perceived Tinnitus Severity

STAT 113: Statistics and Society Ellen Gundlach, Purdue University. (Chapters refer to Moore and Notz, Statistics: Concepts and Controversies, 8e)

Equipment Quality Control for Digital Radiography February 22, Imaging Physics CancerCare Manitoba

EFFECTS OF HMD BACKLIGHT BLEED-THROUGH IN LOW-LIGHT AUGMENTED REALITY APPLICATIONS

SYNCHRO REPLA:Y SYNCHRO REPLA:Y. NEW: ALEX at 3 Hz! MEDICINE AND AESTHETICS. The First Alexandrite Laser Working at 3 Hz

LED-Strip C12 MK2.6. Product Sheet

MEDICAL COMMAND CODER STUDY. Lee B Smith, MD, JD, Theodore Avtgis, PhD, David Kappel, MD, Alison Wilson, MD,

MSF1000. MSF Radio Time Code Receiver. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

LED-Strip C25 MK2.6. Product Sheet

Peer Review Process in Medical Journals

The Taiwanese Journal of Psychiatry (Taipei)

GROWING VOICE COMPETITION SPOTLIGHTS URGENCY OF IP TRANSITION By Patrick Brogan, Vice President of Industry Analysis

Brand Guidelines. A quick guide to using the British Shooting Show brand correctly.

RESOLUTION MSC.95(72) (adopted on 22 May 2000) PERFORMANCE STANDARDS FOR DAYLIGHT SIGNALLING LAMPS

Semi-automating the manual literature search for systematic reviews increases efficiency

Automatic Testing of Color Blindness

AOC ADVANCED OPHTHALMIC CHART. Professional. Intuitive. Stylish. ...the ultimate solution for your acuity charts needs!

How to write an article for a Journal? 1

The Diagnosis of Small Solitary Pulmonary Nodule:

Quantify. The Subjective. PQM: A New Quantitative Tool for Evaluating Display Design Options

Psychological wellbeing in professional orchestral musicians in Australia

Kindly refer to Appendix A (Author s Checklist) and Appendix B (Template of the Paper) for more details/further information.

CESL Master s Thesis Guidelines 2016

Editorial Policy. 1. Purpose and scope. 2. General submission rules

ECE 5765 Modern Communication Fall 2005, UMD Experiment 10: PRBS Messages, Eye Patterns & Noise Simulation using PRBS

Instructions to Authors

Exploratory Analysis of Operational Parameters of Controls

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

Journal of Food Health and Bioenvironmental Science. Book Review

THE ANGMERING SCHOOL CCTV POLICY. The Angmering School CCTV Code of Practice Version 1, 15/02/12, Created by Marc Ginnaw.

Images for life. Nexxis for video integration in the operating room

APPLICATION AND EFFECTIVENESS OF THE SEA DIRECTIVE (DIRECTIVE 2001/42/EC) 1. Legal framework CZECH REPUBLIC LEGAL AND ORGANISATIONAL ARRANGEMENTS 1

GUIDELINES FOR THE PREPARATION OF A GRADUATE THESIS. Master of Science Program. (Updated March 2018)

~AM> P. v. SIEGEL, M.D.

INSTRUCTIONS TO CONTRIBUTORS

VAR Generator Operation for Maintaining Network Voltage Schedules

READ THIS FIRST. Morphologi G3. Quick Start Guide. MAN0412 Issue1.1

Kramer Electronics, Ltd. USER MANUAL. Model: VA-14. 4x1 Balanced Audio Mixer

AMERICAN NATIONAL STANDARD

21. OVERVIEW: ANCILLARY STUDY PROPOSALS, SECONDARY DATA ANALYSIS

ABB i-bus EIB Universal dimmer 6155 EB for Installation

LED-Strip C50 MK2.6. Product Sheet

LIGO Inspiral Veto Studies

VivoSense. User Manual Galvanic Skin Response (GSR) Analysis Module. VivoSense, Inc. Newport Beach, CA, USA Tel. (858) , Fax.

Infrastructure, regulatory and financial information for the antenna-siting community

DESIGN!!GUIDELINES!!!!!

Course Report Level National 5

General Instructions of the Program

DISPLAY WEEK 2015 REVIEW AND METROLOGY ISSUE

Cycloplegic Refractions of Infants and Young Children: The Axis of Astigmatism

Farnsworth F100 Hue Test Instructions

Request for Proposal Questions and Responses. Request for Proposal: Software Based CMED Radio Console and Associated Equipment

Standardization of Field Performance Measurement Methods for Product Acceptance

Instructions for Manuscript Preparation

Journal of Japan Academy of Midwifery Instructions for Authors submitting English manuscripts

AREA CODE EXHAUST AND RELIEF. Questions and Answers

ESCORT & ESCORT AGENCY DOING BUSINESS IN WINNIPEG BY-LAW NO. 91/2008

Evaluation of Female Patients Motivating Factors for Aesthetic Surgery

AGE AND THE PERCEPTION OF A MODULATING TRAFFIC SIGNAL LIGHT IN A FIELD LOCATION

Experiment 4: Eye Patterns

INSTRUCTIONS FOR AUTHORS

In-Line or 75 Ohm In-Line

LINK-MI LM-WHD05B. Wireless HDMI AV Transmission System. User Manual

SceneStyle2 User Guide

MX Compliance Test System System Administrator MXCTSH / MXCTSL. Revision B 1

White Paper. Uniform Luminance Technology. What s inside? What is non-uniformity and noise in LCDs? Why is it a problem? How is it solved?

SECQ Test Method and Calibration Improvements

Transcription:

TECHNICAL NOTE A Modified Protocol for Color Vision Screening Using Ishihara Adrian C. Chorley INTRODUCTION: The Ishihara plates are commonly used as an initial occupational screening test for color vision. While effective at detecting red-green deficiencies, the color deficient subject can learn the test using different techniques. Some medical standards such as the European Aviation Safety Agency (EASA) require plate randomization and apply a stricter pass/fail requirement than suggested by Ishihara. This has been reported to increase the false positive rate up to ;50%. METHOD: Two modifications to the Ishihara protocol are investigated. These involved allowing subjects a second attempt where one or two reading errors were made and the presentation of rotated Ishihara plates. RESULTS: A reduction of false positive rate to 5.9% was found. Correct identification of certain rotated Ishihara plates was not affected. DISCUSSION: By using a modified Ishihara protocol, fewer color normal subjects would require unnecessary advanced color vision examination. Further, additional safeguards would be in place to ensure that no subject with a color vision deficiency could pass the Ishihara test. KEYWORDS: color vision assessment, false positive, Ishihara 24 plate edition. Chorley AC. A modified protocol for color vision screening using Ishihara. Aerosp Med Hum Perform. 2015; 86(8):747 751. IP: 5.10.31.210 On: Fri, 14 Sep 2018 21:40:24 The prevalence of congenital red-green Copyright: color vision Aerospace deficiencies in the European Caucasian male population Delivered is by between Ingentathe severity of a color vision deficiency and the number Medical can be Association regarded as normal. A poor correlation is reported reported at around 8%. 3 The Ishihara test for color deficiency of errors made on the Ishihara plates. 12 is a widely used screening tool in aviation medical exami- It is recognized that the method of administration of a nation and has a high sensitivity in detecting the presence of a screening test such as Ishihara should not allow individuals congenital red-green color vision deficiency. 2 The European with abnormal color vision to pass without further color vision Aviation Safety Agency (EASA) medical requirements for pilot examination. These would be classed as false negative errors. certification state, in EASA MED.B.075(b) Acceptable Means of This could potentially occur if the plates were not randomized Compliance, that for color vision testing: The Ishihara test (24 and the subject had learnt the order by plate number. Randomization plate version) is considered passed if the first 15 plates, presented is recommended by Ishihara if it is suspected that there in a random order, are identified without error. 9 However, a is a deliberate deception on the part of the subject and is number of previous studies have reported that individuals with required in EASA MED.B.075(b). 9 However, it is also possible normal color vision can fail this strict criterion. A conservative for a color deficient subject to correctly state the number within figure of 9.7% of normal trichromats failing the 24 plate edition each plate by learning the unique patterns of dots on each plate. has been reported, 12 although other studies report this to be as high as 44.6% 11 and up to 75.8% in children. 8 These types of error From the UK Civil Aviation Authority, West Sussex, United Kingdom. are classed as false positives. A number of causes for these errors This manuscript was received for review in January 2015. It was accepted for publication have been suggested and include digit confusion error where the in May 2015. number is seen but incorrectly interpreted. Digit confusion Address correspondence to: Dr. Adrian Chorley, B.Sc. (Hons.), M.Sc., Ph.D., F.C.Optom., errors are usually a misinterpretation of 3 and 8, or 7 and 2. 11 UK CAA Medical Department, Safety Regulation Group, Aviation House, Gatwick The Airport South, Sussex RH6 0YR, United Kingdom; adrian.chorley@.caa.co.uk. Ishihara guide to interpretation of results states that if 13 of the Reprint & Copyright by the Aerospace Medical Association, Alexandria, VA. first 15 plates (up to 2 errors) are read normally, the color vision DOI: 10.3357/AMHP.4257.2015 AEROSPACE MEDICINE AND HUMAN PERFORMANCE Vol. 86, No. 8 August 2015 747

This was successfully demonstrated at the UK Civil Aviation Authority (CAA) AeroMedical Centre by photocopying plates 2-13 of the 24-plate edition and removing the plate numbers in order to eliminate any other identification cues. A member of staff learnt differences in the patterns of dots and was able to correctly identify every plate presented randomly within 3 s. In order to reduce both false positives and the potential for false negatives while maintaining the zero error pass requirement, two modifications to the Ishihara testing protocol are investigated. Part 1 describes the results of an audit using a modified protocol which aims to lower the false positive rate and which allowed subjects making up to two errors to retake those misread plates after having been shown a sample of the Ishihara typeface style numbers. Part 2 describes the results of rotating selected Ishihara plates in order to minimize any false negative results due to a learning effect. These modifications can be combined into a single testing protocol described within the discussion section. PART 1: MODIFIED PROTOCOL TO REDUCE FALSE POSITIVE RATE METHODS Subjects The subjects were applicants for initial aeromedical examination at the UK CAA AeroMedical Centre. Color vision screening with Ishihara is required as part of this medical exam and an audit of color vision results was conducted which conformed to the World Medical Association s Declaration of Helsinki. and passing the CAD screen may have either normal color vision Equipment IP: 5.10.31.210 On: Fri, 14 or a Sep degree 2018 of color 21:40:24 vision deficiency within certificatory limits. The first 15 plates from the 24-plate edition Copyright: of Ishihara Aerospace are Medical Association examined under a GretagMacBeth (New Windsor, Delivered NY) Sol by Ingenta Source D65 daylight lamp. The book is presented normally to the line of vision at approximately 75 cm and a 3-s maximum response time per plate is allowed. Applicants failing Ishihara undergo further color vision assessment using the Color Assessment and Diagnosis (CAD) test. This is a computer based color vision test using a calibrated display screen which is reliably able to detect, 13 diagnose, and quantify color vision deficiencies. 5 7 The CAD protocol involves the use of an initial screening test at 6SN (standard CAD units). If this quick test is passed, a full red-green threshold is not required. Those applicants failing the CAD screening test would have a degree of color vision deficiency 13 and would require full threshold examination. Up to certain degrees of color vision deficiency are considered acceptable for unrestricted aeromedical certification. 6 Procedure Six Ishihara plates from a 38-plate edition were selected using, where possible, plates with different numbers from the 24-plate edition. Each dot within the number was colored black and the plates were photocopied, laminated, and placed above the Ishihara testing area. Three plates had two-digit numbers and three had single-digit numbers and together represented samples of numbers from 1-9. Where a subject made up to two errors, they were shown these sample typeface numbers with particular attention paid to the numbers which were confused. The subject was then allowed a second attempt at identifying those numbers initially misread. Using this technique, it was found that most subjects then correctly identified the Ishihara plate(s) when shown them for a second time. In order to quantify the effect, an audit of the result of all color vision assessments carried out as part of an initial medical examination at the UK CAA AeroMedical Centre from 1 January 30 June 2013 was conducted. This included assessment of the results from all applicants within the audit period of the screening and any advanced color vision tests conducted as part of the initial medical examination. Using data saved on the CAD laptops, all CAD tests carried out as part of an initial medical within the audit period were identified. It was anticipated that all CAD test results would fall into one of four categories: those with color vision deficiencies who would not be considered color vision safe following full red-green threshold testing; those with color vision deficiencies who would be considered color vision safe following full redgreen threshold testing; those making greater than two errors using the modified Ishihara protocol, but who passed the CAD screening test; and, finally, those making one or two errors using the modified Ishihara protocol who passed the CAD screening test. For the purposes of the audit, those subjects who made one or two errors using the modified Ishihara protocol and who passed the CAD screen were considered to have normal color vision in the absence of a full red-green CAD threshold being carried out. Those making more than two errors on Ishihara RESULTS A total of 694 initial subjects were examined from 1 January 2013 to 30 June 2013. This resulted in a total of 40 CAD tests being carried out ( Table I ). The CAD test is able to definitively diagnose the presence of a color vision deficiency once a full threshold test has been completed. If the subject passes the CAD screening test, it can only be concluded that if a color vision deficiency is present, it would be sufficiently mild such that it would be within standards and considered color safe for aviation medical certification. Of the six subjects who passed the CAD screening test and who made greater than two Ishihara errors, four made three errors, one made four errors and one made eight errors. All 11 subjects who undertook full CAD threshold testing were diagnosed with a degree of color vision deficiency. If all those who passed the CAD screen were assumed to have normal color vision, a total of 11 (1.6%) subjects were considered to have some degree of color vision deficiency and, therefore, 683 of the subjects who were examined had normal color vision, of which 29 were considered to have normal color vision, but required a CAD test. This resulted in a 4.2% false 748 AEROSPACE MEDICINE AND HUMAN PERFORMANCE Vol. 86, No. 8 August 2015

Table I. Summary of CAD Results Against the Outcome of Ishihara Using the First Protocol Modification. ISHIHARA RESULT TOTAL PASS CAD SCREEN FAIL CAD SCREEN PASS CAD AFTER THRESHOLD TESTING FAIL CAD Zero errors 653 N/A N/A N/A N/A 1 or 2 errors 23 23 0 0 0 More than 2 errors 17 6 11 6 5 Total 694 29 11 6 5 Only those making errors on Ishihara went on to undergo Color Assessment and Diagnosis (CAD) testing. All subjects who underwent full CAD threshold testing had a degree of color vision deficiency. positive rate for Ishihara using the modified protocol. This is likely to be a conservative figure as it is possible that some of the six individuals making more than two Ishihara errors had a color vision deficiency and if these six were to be reclassified, a revised false positive rate of 3.4% would result. Chi-squared analysis revealed that the conservative calculation of the false positive rate is significantly lower than previous 12 fi ndings ( x 2 5 9.94, df 1, P 5 0.002) using the 24-plate Ishihara standard protocol with a zero error pass requirement. PART 2: MODIFIED PROTOCOL TO MINIMIZE FALSE NEGATIVES METHODS RESULTS During the first selection of rotated plates, a total of 64 assessments were carried out. All subjects had previously made no errors on Ishihara using the 24-plate edition with plates randomized and using the modified protocol described in Part 1. A total of 39 (61%) made errors on the second Ishihara book; 25 subjects made 1 error, 12 subjects made 2 errors, 1 subject made 3 errors, and 1 subject made 4 errors. It was, however, observed that all errors were made on double-digit rotated plates rather than single-digit rotated plates. For the second selection of rotated plates, a total of 90 assessments were carried out. Again, all subjects had previously made no errors on Ishihara using the protocol described in Part 1. A total of 28 (31%) subjects made errors on 1 or more plates of which 4 were on nonrotated plates (subjects were not offered a second opportunity to correct misread plates in this phase). A total of 29 errors were made on rotated plates. There were 10 errors that arose where the plate containing 6 was misread as 9 and had been rotated by 90. This is a vanishing plate and no number is visible to the color vision deficient subject. A further 18 errors were made with 3 being named as 8 when rotated (response by a color deficient would be 5 for this plate). Nei- Subjects Subjects were applicants for initial Class 1, 2, or 3 medicals at the UK CAA AeroMedical Centre and were tested, as part of the eye examination, using the 24-plate Ishihara edition with randomized plates and modified protocol as described in Part 1. Only those applicants who had passed Ishihara and did not ther of these plates were used in the original selection of rotated require CAD testing were included for IP: this 5.10.31.210 part of the On: study. Fri, 14 plates. Sep 2018 There 21:40:24 was one further error for a single-digit rotated Subjects were given details of the survey Copyright: and gave Aerospace informed Medical plate where Association 3 was named as 60. consent. The survey conformed to the World Medical Association s Declaration of Helsinki. Procedure Six plates (excluding plate numbers 1, 14, and 15) were randomly selected within a second 24-plate Ishihara book and were randomly rotated by 90 either clockwise or anticlockwise. These plates were reinserted into the book and were not changed between each assessment. The data collection period ran from 15 August to 31 October 2013. At the end of their eye examination, subjects undertook a further Ishihara test using the second book containing some rotated plates. Subjects were informed that the result of the second Ishihara book would not impact on their medical certification. Subjects were also informed that some pages presented would contain a number which would not appear in the normal orientation. Any errors made using this second Ishihara book were documented including the number of errors and the type of confusions made; however, no personally identifiable data was used. From 11 September onwards, a different selection of six Ishihara plates consisting of only single-digit numbers were randomly rotated. It was calculated that, if the five single-digit plates described in Table II were to be rotated, this would alter the overall false positive error rate to 5.9% using the combined modified protocol using randomized Ishihara with rotated plates. This rate remained significantly lower ( x 2 5 4.15, df 1, P 5 0.04) than the independently reported false positive rate of 9.7%, where 23 out of a sample of 236 color vision normals made error(s) on the Ishihara. 12 DISCUSSION The Ishihara test is known to be an extremely sensitive test at detecting congenital red-green color vision deficiencies. 2 The principle of allowing zero errors is likely to increase its sensitivity further, but at the detriment of its specificity, with high false positive rates reported. The modified testing protocol described in Part 1 should maintain high sensitivity while reducing false positive results to around 4%. It is recognized that as these data were collected retrospectively, no intraobserver measure of false positives between the standard and modified protocols AEROSPACE MEDICINE AND HUMAN PERFORMANCE Vol. 86, No. 8 August 2015 749

can be made. Additionally, the number of subjects who made 2010 and the edition with rotated plates was manufactured in one or two errors and who then correctly identified the Ishihara 2000. Although stored carefully away from direct sunlight, it is plates on the second attempt was not documented. However, possible that the plates in the older edition may have been it has been consistently reported in studies employing large affected by fading. 10 Additionally, although the plates in both cohorts that a percentage of normal trichromats make errors on books were randomized, the order of numbers was not the same. the Ishihara plates. 1,12 The lower the number of errors allowed It is not known what the effect that plate order has on outcome, to pass the test, the higher the incidence of a false positive result. but it is known that some numbers are easier to identify It was not possible in Part 1 of the study to determine than others. 4,8,11 However, previous studies have not assessed whether the small group of subjects who made three or more the effect of plate randomization on reading error rate. It is possible Ishihara errors but passed the CAD screening test do indeed that an early presentation of a more difficult number such have a color vision deficiency as further examination was not as 73 may cause a higher error rate than if presented after the warranted for certificatory purposes. It is reported that up to six single digit 3 and single digit 7 as in the original plate order. errors may be made (on the 38-plate edition) by color normal However, the use of the modified protocol allowing up to two subjects 4 and it has been recommended that up to four errors reading errors to be corrected at a second attempt should help be allowed so as not to disadvantage normal trichromats. 12 to counter this effect, if present. Where a limit of three errors or less are allowed, 10% of deutan It is also recognized that this study has not been able to quantify and 1% of protan subjects are reported to pass Ishihara. 12 As the effect of plate rotation on the false negative rate. This is five of these six individuals made four or fewer errors, it seems because it has always been assumed at the AeroMedical Centre likely that the majority of this group would likely have normal that those passing the Ishihara test have normal color vision and color vision; however, the false positive rate found in this study do not require, for certificatory purposes, further color vision remains significantly lower than even conservative figures previously examination. Therefore, it can only be concluded that plate rota- reported. 12 tion will reduce the likelihood of a subject obtaining a normal The Ishihara test may not be able to detect subjects with result by deceit while minimally affecting false positives. color vision deficiencies who employ other techniques in plate These findings indicate that employing the modified protocol recognition in order to obtain a normal result. This is more using some single digit rotated plates and allowing up to two likely to occur in environments such as aeromedical examination, errors to be corrected at a second attempt as described would where applicants are motivated to gain a favorable medical ensure that significantly fewer numbers of subjects would be outcome. It is seen occasionally using the randomized plates unnecessarily required to undergo further advanced color where a subject calls the correct numbers in the original order vision testing, saving time in a busy clinic environment. Additional of the book. It has also been shown that subjects with color measures would be in place to ensure that no individual vision deficiencies could potentially use dot pattern recognition with a color vision deficiency would be able to falsely obtain an to ensure they read all plates correctly. There is no means of Ishihara pass and avoid undergoing further detailed color assessing if color vision deficient subjects have achieved this to vision assessment. Finally, any effect to the time taken to administer Sep the 2018 Ishihara 21:40:24 test under this suggested protocol is likely to date as they would have been passed as IP: color 5.10.31.210 normal without On: Fri, 14 further color vision testing. Copyright: Aerospace be Medical minimal. Association The rotation of selected plates offers an addition safeguard against this strategy and these results indicate that it would only marginally affect the false positive rate if the plates were rotated as suggested in Table II. By having a zero error pass requirement for the Ishihara screening test, it would make it extremely unlikely that a color deficient subject could recognize rotated Ishihara plates by dot pattern recognition within the 3 s per plate test requirement. A modified testing protocol should include an explanation to the applicant prior to the test that not all the numbers would appear in the normal orientation. It should be noted that the two versions of the Ishihara plates used in this study were of a different age. The 24-plate edition with randomized plates used in Part 1 was manufactured in Table II. Suggested Rotation for Five Ishihara Plates. PLATE NO. COLOR NORMAL SEES SUGGESTED ROTATION 2 8 90 clockwise or anticlockwise 4 5 90 clockwise or anticlockwise 8 6 180 10 5 90 clockwise or anticlockwise 11 7 90 clockwise or anticlockwise ACKNOWLEDGMENTS Author and affiliation: Adrian C. Chorley, B.Sc. (Hons.), M.Sc., Ph.D., F.C.Optom., Medical Department, Safety and Airspace Regulation Group, Civil Aviation Authority, West Sussex, United Kingdom. REFERENCES 1. Belcher SJ, Greenshields KW, Wright WD. Colour vision survey using the Ishihara, Dvorine, Boström and Kugelberg, Boström, and American- Optical Hardy-Rand-Rittler tests. Br J Ophthalmol. 1958 ; 42 (6 ):355 359. 2. Birch J. Identification of red-green colour deficiency: sensitivity of the Ishihara and American Optical Company (Hard, Rand and Rittler) pseudo-isochromatic plates to identify slight anomalous trichromatism. Ophthalmic Physiol Opt. 2010 ; 30 (5 ):667 671. 3. Birch J. Worldwide prevalence of red-green color deficiency. J Opt Soc Am A Opt Image Sci Vis. 2012 ; 29 (3 ):313 320. 4. Birch J, McKeever LM. Survey of the accuracy of new pseudoisochromatic plates. Ophthalmic Physiol Opt. 1993 ; 13 (1 ):35 40. 5. Birch J, Rodriguez-Carmona M. Occupational color standards: new prospects. J Opt Soc Am A Opt Image Sci Vis. 2014 ; 31 (4 ):A55 A59. 750 AEROSPACE MEDICINE AND HUMAN PERFORMANCE Vol. 86, No. 8 August 2015

6. Civil Aviation Authority. Minimum colour vision requirements for professional flight crew. Part III. Recommendations for new colour vision standards. Norwich (UK): The Stationary Office; May 2009. Report No: CAA Paper 2009/04. 7. Connolly DM, Barbur JL, Hosking SL, Moorhead IR. Mild hypoxia impairs chromatic sensitivity in the mesopic range. Invest Ophthalmol Vis Sci. 2008 ; 49 (2 ):820 827. 8. Cosstick M, Robaei D, Rose K, Rochtchina E, Mitchell P. Numerical confusion errors in Ishihara testing: findings from a population-based study. Am J Ophthalmol. 2005 ; 140 (1 ):154 156. 9. European Aviation Safety Agency. Notice of proposed amendment 2013-15. MED.B.075(b). Cologne (Germany): European Aviation Safety Agency; 2013. 10. Hyon JY, Lee JH, Wee WR. Shift of colorimetric values in Ishihara pseudoisochromatic plates with plate aging. Korean J Ophthalmol. 2005 ; 19 (2 ):145 148. 11. Miyahara E. Errors reading the Ishihara pseudoisochromatic plates made by observers with normal colour vision. Clin Exp Optom. 2008 ; 91 (2 ):161 165. 12. Rodriguez-Carmona M, O Neill-Biba M, Barbur JL. Assessing the severity of color vision loss with implications for aviation and other occupational environments. Aviat Space Environ Med. 2012 ; 83 ( 1 ): 19 29. 13. Seshadri J, Christensen J, Lakshminarayanan V, Bassi CJ. Evaluation of the new web-based Colour Assessment and Diagnosis test. Optom Vis Sci. 2005 ; 82 (10 ):882 885. IP: 5.10.31.210 On: Fri, 14 Sep 2018 21:40:24 Copyright: Aerospace Medical Association AEROSPACE MEDICINE AND HUMAN PERFORMANCE Vol. 86, No. 8 August 2015 751