Micro-DCI 53ML5100 Manual Loader

Similar documents
SCALE & WEIGHT DISPLAYS

LAUREL ELECTRONICS, INC.

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

263 Series LED Bargraph Indicator and Controllers

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

QRF5000 MDU ENCODER. Data Sheet

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

SQM40/41 Actuators for air and gas dampers

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

DCP100 Digital Control Programmer Specifications

CARLO GAVAZZI Automation Components

DUAL/QUAD DISPLAY CONTROLLER Operation Manual

Process Transmitter RMA 422

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Single Axis Position Controller

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

Model IQ4-PC User Manual Revision Date:

multi-function meters

Capacitance Level Measurement Electronic insert FEC 12

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

DATA SHEET Panorama Rudder Indicator, TRI-2

Typical applications:

Process transmitter RMA422

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

Model Number Structure

AC182A 8 Input x 8 Output S-Video Matrix Switch with Audio

Mains Supply. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length 300 m (with 1.5 mm² cable). Example: Belden 8471.

Safety Light Curtains GuardShield

Intelligent Security and Fire Ltd

High Performance Outdoor Test Translators

Wall-/Pipe-Mount Level Indicator

Technical data. General specifications. Indicators/operating means

Electronic converter for level transmitters MT03L Instructions manual

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Single-Output 2000 W

Section C Recorders. DPR mm Digital Strip Chart Recorder

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

SYNTHESIZED COMMUNICATION CONVERTERS

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

Product Guide. Analog Panel Meters for use in Electrical Engineering Systems. M Series. Instruments clamping to 35 mm DIN rails W/P/ LSP BWQ BGQ

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Standard signal metering in wall-mounting case

AX 345. Process Indicator with Two Analogue Inputs, Calculations and Programmable Analogue Output. Operating Instructions for Model AX 346

Multiple Band Outdoor Block Up- and Downconverters

Nikon s DigiMicro Position Encoders Nanometer Resolution with Sub-Micron Accuracy

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

SXT SXGA TFT NEMA 4/12 Flat Panel Monitor. User s Guide

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

VM-100R. 1 RU HEIGHT PROGRAMMABLE 70 AND 140 MHz HIGH-PERFORMANCE VIDEO/AUDIO MODULATOR

Data Pattern Generator

DPM 942-FPSI 4-20mA Loop Meter with Programmable Backlighting

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Quad Video Switching Box User Manual

HS-509 VIBRATION TRIP MODULE

AF-300 E11 Adjustable Frequency Drive

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Kuhnke Technical Data. Contact Details

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

DELV-2LCD-7XLPRO DELV-2LCD-7XLRM DELV-2LCD7XLS (SDI) USER MANUAL

Quick-Start for READ30

Gamma instabus. Technical product information

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

Standard RS232 RS ma

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

EVF 300 series. Controllers for electric bread and pizza ovens, with touch-keys, in split version and which can be integrated into the unit.

APPLICATIONS. Automatic warehouse. Trasportation lines

R-1580A Microwave Downconverter. Product Brochure

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Micro-Machined Silicon Transducers

Lt DELTA USA, Inc

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

28 To 48 Rugged UltraWide Industrial Displays

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

Condition Monitoring Custom Products

MT03A Electronic converter for flow rate transmitters

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal

Modular Lube Lubrication Systems System Controls

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

Hybrid Chart Recorder 250 mm (10")

0.56" 4 Digital Blue LED Panel Meter (rescalable) User s Guide

Pen and Multichannel Recorder: Digital Display

Transcription:

Micro-DCI 53ML5100 Manual Loader Two process variable inputs Two manually controlled current outputs Multiple Display Formats: Dual Channel Manual Loader, Single Channel Manual Loader, Manual Loader with Analog Input, Analog Input w/manual Setpoint Configuration via the front display Password Security 53ML5100 Manual Loading Station Specification Sheet S-DCI-53SL5100_1

53ML5100 Micro-DCI Manual Loading Station The 53ML5100 manual loading station provides manual adjustment of two independent current outputs. Each output is independently configurable as a 0-20 ma or 4-20 ma signal. The manual loading station can accept two input process variables that are each presented on separate displays. The two input process variables have independent configurable input current / voltage ranges (0-20 ma, 4-20mA, 0-5V, 1-5V), with square root signal extraction and smoothing selections from 0 seconds to 1638 seconds. (first order filtering) A digital readout located in the center quadrant of the two display segments indicates the percentage of control signal output. As shown in Figure1, the manual loading station contains a graphical dot matrix display; horizontal and vertical keypads; a MINI-DIN RS-232 configuration port connector concealed behind the front panel pull down door; terminals for signal input/output wiring and power wiring; and a compact instrument case that protects the instrument main printed circuit board and internal power supply A suite of six operator displays is used to monitor the two input process variables and the two manually controlled current outputs. The displays are a mix of dynamic bar graphs that include a dual channel manual loader (Channels 1 & 2), a single channel manual loader display (Channel 1 only), two manual loader with analog input displays (Channels1 & 2), two analog input indicator with setpoint displays (Channels1 & 2 ). The presentation order of the six operator displays is configurable. The 53ML5100 has the ability to show individual tagnames, input range, and user specified engineering units for each channel. The descriptive displays allow you to observe the condition of the process at a glance. From the standard library of six preconfigured displays you can use one (or a group of displays) that best represents your application. Push buttons on the front panel allow access to all the datapoints in the instrument. This ensures quick, easy, and low cost configuration of the parameters. Dual Channel Manual Loader Display - (Channels 1 & 2) - Figure 1 shows a 53ML5100 with its standard two channel horizontal bar graph display. Both channels outputs are presented as horizontal bar graphs with tagnames and digital readouts of the output percentage. Channel 1 (Analog Output 0, ANO-0) occupies the lower half of the display. A thick border shown around the perimeter of the upper or lower display half indicates a selected channel for manual output control. Figure1. Two Channel Horizontal Bar Graph Manual Loading Display The thick border alternately appears on the upper or lower display halves each time the 3 push button is pressed. 2

Figure 2. Single Channel Horizonal Bar Graph Manual Loader Single Channel Manual Loader Display - Figure 2 ( Channels 1 & 2 ) - Both channel outputs are presented as a horizontal bar graph with a tagname and digital readout of the output percentage. The display has a permanent thick border surrounding it to indicate selection for manual output control. This display is used when a single output is required and focuses attention on that output. Manual Loader with Analog Input Displays - Figure 3 (Channels 1 & 2) - Each display has a vertical bar graph for analog input process variable (PV) indication and a horizontal bar graph for analog output manual control. The vertical bar graph has a 50 segment axis and the horizontal bar graph has a 40 segment axis. The vertical bar graph has a numeric range (zero and span) and the horizontal axis has the forward /reverse valve indicators (C for close, O for open). An input channel tag name appears in the upper left corner of the display. Figure 3. Vertical Bar graph Manual Loading Function with the analog input being indicated A digital readout with measured units for the analog input channel appears under the letters PV in the upper half of the display. A digital readout for the analog output channel appears under the horizontal bar graph. Analog Input Indicator with Setpoint Displays - Figure 4 (Channels 1 & 2) Each display has a vertical bar graph for analog input process variable (PV) indication and a setpoint (SP) arrowhead for analog output manual control indication. The vertical bar graph appears on the left side, parallel to a 50 segment vertical axis. The setpoint arrowhead appears on the right side of the vertical axis. The vertical axis has a numeric range (zero and span) an input channel tag name appears in the upper left corner of the display. A digital readout for the analog input measured units tagname in the middle of the display and beneath it a digital readout appears under the letters PV. 3

The display is a 96 X 48 gas discharge dot matrix, contrasted orange on black to enhance visibility. The intensity of the instruments' display is adjustable from 0 to 7, with 0 being the brightest setting. The 53ML5100 has a built in 24Vdc transmitter power supply providing up to 80 ma. Terminals for the power supply are located on a rear terminal block. Configuration of the instrument is accomplished using the MicroMod Automation Micro-Tools configuration software, or by direct entry through the front panel vertical and horizontal keypads. Both keypads have functioning push buttons that are dependent on the instruments' mode of operation. Modes of operation are operator mode and engineering mode. Mode selection is made with the mode button ( ) push button on the horizontal keypad. Engineering mode is entered to make the necessary selections for the operator displays; otherwise, the instrument is left in operator mode for process applications. Figure 4. Analog Input Indicator with Setpoint display Each manual loading station contains a graphical dot matrix display, horizontal and vertical keypads; a MINI-DIN configuration port connector concealed behind the front panel pull-down door; terminals for signal input/output wiring and power wiring; and a compact instrument case that protects the instrument main printed circuit board and internal power supply. All of the selectable entries for the Manual Loading Station are parameter entries to the database. The databse is subdivided into modules composed of datapoints that are accessed by the instruction code as the instrument performs its functions. The database allows instrument functionality to be refined to specific process applications, as display attributes can be altered and input / output signal characteristics can be defined. A parameter can be any one of five data types. Each data type represents a specific data format: integers, alphanumeric text strings, floating point values with 15 bit resolution, and high resolution 31 bit floating point values. Each display has individually configurable tagnames and engineering units. You can select either forward or reverse (default) output reaction in relation to the final element. Each output channel can be configured as either a 0-20 ma or 4-20 ma output source. All of the selectable entries for the manual loading station are parameter entries to the database. The database of the instrument is divided into modules composed of datapoints that activate/ deactivate/enter operating characteristics for the instrument to use as the instrument performs its functions. The database allows instrument functionality to be refined to specific process applications. 4

ENGINEERING SPECIFICATIONS OPERATING CHARACTERISTICS Power Requirements: 24 Vdc +/ - 2 Vdc 120 Vac + / - 10% @ 50-60 Hz 220/240 Vac + / - 10% @ 50-60 Hz Power Consumption: AC operation: 15 VA Internal Power Supply Available Power Output for Transmitters: 24-26 Vdc, 80 ma, short circuit protected Output Ripple: 200 mv p-p maximum ENVIRONMENTAL CHARACTERISTICS Enclosed temperature controlled locations (class A and B per ISA S71.01 1985) Ambient Temperature Limits: 4 to 52 C ( 40-125 F ) Relative Humidity Limits: 10 to 90% maximum PHYSICAL CHARACTERISTICS Case: Steel Finish: Baked enamel, Lt. Gray - RAL9002 Circuit Boards: Glass epoxy Bezel: ULTEM 1000 UL-94 5 V Dimensions: DIN case (72 W x 144 H x 329 mm L ) (2.8 W x 6.6 H x 12.9 in L ) Electrical Connection: Rear of Case: Compression type screw terminals Display: 96 x 48 Pixel Push Buttons: 10 (Tactile membrane switches) MICROPROCESSOR SAMPLING & UPDATE Input Signal Sampling Rate Analog: Display Update: Analog Outputs Quantity: 2 50 ms for all inputs, outputs 100 ms Temp. Effect on Accuracy: +/- 0.28% per 28 C ( 50 F ) from reference temperature of 25 C( 77 F ) Analog Inputs Quantity: 2 Signal Range: 0-5 or 1-5 V linear or square root Input Impedance: 1 megohm minimum for voltage inputs; value of ranging resistor for current signals. Measurement Accuracy: + / - 0.1% of span Signal Range: Accuracy: Load Resistance: 0-21.84 ma dc (4-20 ma dc typically ) + / - 0.2% of span ( Current output is updated every 0.3 seconds. The output slew rate is 40 ma/sec. ) 0-750 ohms Note: The standard rear terminal board has the appropriate resistors on ANI0 and ANI1. If the input signal is voltage, the resistors should be removed. 5

Model Number Designation Power Requirements AC (120, 240 Vac 50, 60 Hz )... 1 DC (24 Vdc )... 2 Functional Requirements Standard... 1 Standard with Factory Configuration... 2 53ML51 A 2 1 A B Design Level... A Enclosure Type DIN 72 x 144 mm... 2 ( 2.844W x 6.656 H x 12.906 in. L ) Rear Terminal Board Standard Rear Terminal Board... 1 Chassis Standard Chassis...A Safety Classification Factory Mutual Class 1, Div. 2... B Conformal Coating None... X Required... A Product Summary Two independent output channels Six standard user selectable displays Intuitive Operator Interface Built in 24 Vdc 80 ma Transmitter Power Supply Selectable functions such as Forward or Reverse acting outputs DIN case Two Analog Inputs Two Analog Outputs Fully configurable Inputs & Outputs www.micromodautomation.com The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in USA (05.5.04) MicroMod Automation, Inc. 2004 MicroMod Automation, Inc. 75 Town Centre Dr. Rochester, NY 14623 USA Tel: (585) 321-9200 Fax: (585) 321-9291 Email: sales@micmod.com 6