Level Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB

Similar documents
Installation instructions Cable transit device Roxtec RS ES Ex

Installation instructions Roxtec RS ES Ex

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

Installation instructions Ex frames

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Inductive sensor NI3-EG08K-Y1-H1341

Eddy Current Probe System

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor NI10-M18-Y1X-H1141

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Inductive sensor BI1.5-EG08K-Y1

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

3 Cleaning. 4 Technical data

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

Capacitance Level Measurement Electronic insert FEC 12

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

7 Lighting Technology

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

PMG. Vibration Energy Harvesters

Model /29S RF Splitter

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

TUC: Universal thermostat

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Instructions. P MHz 1X/10X Passive Probe

MKH 8060 Directional studio microphone

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

PROPORTIONAL VALVES Sentronic plus

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Pressure transmitter For applications in hazardous areas Model IS-3

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

GaAs MMIC Double Balanced Mixer

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Operating instructions

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

PRO Mixer Distro User Guide

Colour Explosion Proof Video Camera USER MANUAL VID-C

Process Transmitter RMA 422

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual Model # Block Upconverter

Manual. USP-mini. icroflown Technologies. Address: PO Box CE Arnhem The Netherlands Charting sound fields

Instruction Manual Model BlockUpconverter

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

EZ-LIGHT S18L Color General-Purpose Indicators

Level Measurement silometer FMC 420, FMC 423

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Installation instructions Roxtec RM ES B

KHT 1000C HV-Probe Calibrator. Instruction Manual

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

INSTRUCTION MANUAL PULSUS PHONO PRE-AMPLIFIER. Extended 5-Year Warranty

Manual. USP-regular. icroflown Technologies. Address: PO Box CE Arnhem The Netherlands Charting sound fields

Mechanical flow switch for On/Off control

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Explosion Proof Audible Signal db(a) Series YA60

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

Connecting cables for valves, round plug connectors Product range overview

Installation instructions Roxtec RM ES

MT03A Electronic converter for flow rate transmitters

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

Installation instructions Roxtec CM PE systems

EZCOM-1. PLC - to - AMS MESSAGE DISPLAY INTERFACE INSTALLATION AND OPERATING INSTRUCTIONS. Rev March, 2001

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Linear Array with Intensity Adjustment

WLS27 Multicolor LED Strip Light with EZ-STATUS

Garmin GC 10 Marine Camera Instructions

GaAs MMIC Double Balanced Mixer

User Guide. HDMI Fiber Optic Extender. DVI-7350a

PKT 512A-RO. High impedance passive cable divider. Features: BNC to BNC connection. 500 MHz system bandwidth. Double HF adjustment

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

PKT 512A-RO. High impedance passive cable divider. Features: BNC to BNC Connection. 500 MHz System Bandwidth. Double HF Adjustment

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

User Manual. Adjustable Speed Vortex. Fixed Speed Vortex

GaAs MMIC Double Balanced Mixer

INSTRUCTION MANUAL PELLAR PHONO PRE-AMPLIFIER. Extended 5-Year Warranty

VK-P10SE WARRANTY REGISTRATION FORM

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

Photovoltaic Module Installation Manual (IEC)

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

Transcription:

Level Switch LS Ex KS Ex RS Ex Manual

Level Switch Ex Manual version 3.0 March 2013 2

1. Table of contents 1. Table of contents...3 2. Manufacturer information...4 Manufacturer Declaration of Conformity...4 Limited Warranty...4 Returning the Level Switch Ex...4 Warning...4 3. Introduction...5 4. Mode...5 5. Level Switch Mode...5 6. Level Sensor Mode...5 7. Gluing the Level Switch Ex...6 8. Connecting the Level Switch Ex...6 Choosing a barrier...6 Ex-barriershields...7 Intrinsically Safe Barrier...7 Connecting Level Switch & Level Sensor via barrier to D72 or DP72...9 Connecting Level Switch & Level Sensor via barrier to D128... 10 Technical data... 11 Dimensions... 12 9. Manufacturer information... 13 Label information... 13 Intrinsic parameters... 13 EX description... 13 3 Level Switch Ex Manual

2. Manufacturer information operates a policy of on-going development and reserves the right to make changes and improvements to any of the products described in this manual without prior notice. Under no circumstances shall be held responsible for any loss or indirect damage howsoever caused. The contents of this document are provided as it is. reserves the right to revise this document or withdraw it at any time without prior notice. Manufacturer Declaration of Conformity Manufacturer: Sweden declares, that the product: Level Switch Ex marked with CE-label conforms with the following standards: IEC 60079-0:2011 (Ed. 6), IEC 60079-11:2011 (Ed. 6), EN 60079-0:2012 (Ed. 4), IEC 60079-11:2012 (Ed. 2) Level Switch Ex marked with conforms to WEEE, directive 2002/96/EC. When the Level Switch Ex is to be discarded it shall be sent back to for safe disposal. See Manufacturer Information for return address. Level Switch Ex is RoHS Compliant, directive 2002/95/EC. Limited Warranty warrants to the original end user that the Level Switch Ex is free from any defects in materials or workmanship for a period of one year from the date of purchase. During the warranty period, should the Level Switch Ex have indications of failure due to faulty workmanship or materials, AQ Elteknik AB will replace it with no charge. This warranty shall not apply if the Level Switch Ex is modified, misused or subjected to abnormal working conditions. Replacement as provided under this warranty is the only remedy of the purchaser. The purchaser pays freight to. shall in no event be held liable for indirect or consequential damages of any kind or character to the purchaser. Returning the Level Switch Ex If the Level Switch Ex is to be discarded it shall be sent back to for safe disposal. If the Level Switch Ex shall undergo a warranty commission it shall be sent back to AQ Elteknik AB. Before sending the Level Switch Ex to it must be clean and without any harmful contaminations. A certificate shall be attached with the Level Switch Ex that confirms the cleaning and shows following information: Who has cleaned the Level Switch Ex (company if other than sender) Who has checked and confirmed that the Level Switch Ex is clean (company and person) Who is sending back the Level Switch Ex (company) See Manufacturer Information for return address. Warning The Level Switch Ex is intended to be connected to the Ultrasound Controller manufactured by AQ Elteknik AB. takes no responsibility for any possible damage that could happen if the Level Switch Ex is connected to any other equipment. 4

3. Introduction When the Level Switch Ex is attached to the outside of a container or pipe it can sense liquid level inside. The Level Switch Ex senses trough the wall without any need for a hole in the container. The Level Switch Ex is made to be used together with the Ultrasound Controller. 4. Mode The sensor Mode setting of the Ultrasound Controller determines in which way the Level Switch Ex measures the level. In Level Switch mode the Level Switch Ex measures a single level from the side. In Level Sensor mode the Level Switch Ex measures a continuous level from the bottom. 5. Level Switch Mode In Level Switch Mode each Level Switch Ex measures a single level. It measures the presence or no presence of liquid behind the container wall or pipe wall. All types of Ex Level Switches can be used in Level Switch Mode but use different measuring techniques. There are two measuring techniques Echo and WR (see Ultrasound Controller manual). Level Switch KS Ex and Level Switch LS Ex should be used with the Echo technique and Level Switch RS Ex must be used only with the WR technique. The Level Switch Ex is attached on the wall of the container or pipe. For a cylindrical wall, a Level Switch with a diameter close to the diameter of the container should be chosen. The ultrasound must pass easy into the container or pipe; therefore there must be a tight ultrasound-connection without any air-gap between the Level Switch Ex and the wall. 6. Level Sensor Mode In Level Sensor mode the Level Switch Ex measures the continuous liquid level. The Level Switch Ex is attached under the container and measures trough the bottom. Level Switch KS Ex or Level Switch LS Ex should be used (Level Switch RS Ex cannot be used). A Level Switch Ex that fits the shape of the bottom should be chosen. The Level Switch Ex measures the echo that bounces at the liquid surface. It is important the echo goes straight back to the Level Switch Ex. If the Level Switch Ex and the bottom are not horizontal then the echo may bounce in another direction. If the bottom is not horizontal, metylmetacrylate glue can be used to glue the Level Switch Ex at an angle. In this case the Level Switch should be connected to Ultrasound Controller and be active measuring while being glued so that it can be adjusted for maximum echo. Sound has to be able to pass through the bottom. Most plastics let sound trough well except polypropylene and fiber reinforced plastics. For stainless steel, a bottom thickness of 5,8mm is the maximum recommended. Stainless steel 5,8mm 2,9mm and 1,45mm works well at 2MHz which is the optimal frequency for the Level Switch Ex. For other thicknesses other frequencies will be chosen by Ultrasound Controller. Sound velocity varies with liquids and temperatures. A Level Switch Ex placed low on the container wall can be used to measure and compensate for sound velocity changes. More information: Ultrasound Controller manual. 5 Level Switch Ex Manual

7. Gluing the Level Switch Ex The Level Switch Ex is glued to the outside of the container and the gap between the Level Switch Ex and the container is filled with glue. If the container is cylindrical choose a Level Switch Ex with a diameter close to the diameter of the container. Important: Before gluing, make sure the echo will be reflected back to the sensor and that there is nothing inside the container blocking the echo. Also make sure the surface of the container under the Level Switch Ex is even and not a weld joint. The ultrasound can pass into the container only if there is an air-tight ultrasound-connection between the Level Switch Ex and the container. To make such a connection the Level Switch Ex can be glued with Metylmetacrylate glue or Electrolube HTC compound or Silicone. Gluing the Level Switch Ex with Metylmetacrylate glue: Put a mix of the two parts of Metylmetacrylate glue on the inner (container-facing) side of the Level Switch Ex and press it on to the container and hold it there until glue has cured (10 minutes). The metylmetacrylate glue should cover the gap. Metylmetacrylate glue is fast and easy to use. The gap thickness should be made as thin as possible. Temporary installing the Level Switch Ex with Electrolube HTC: Put Electrolube HTC on the inner (container-facing) side of the Level Switch Ex and press it on to the container. Use a clamp or cable ties to hold the Level Switch Ex in place. The Electrolube HTC compound does not get stiff. If the Level Switch Ex is removed it is recommended to wipe off the old compound and use new next time. NOTE! The connector must not be turned 8. Connecting the Level Switch Ex The connector on the cable fits the Level Switch Ex and the other end of the cable connects to the barrier (hazardous side). The maximum cable length is 40m. A similar screened cable connects the safe side of the barrier to the Ultrasound Controller. The cable-screen is important because it prevents external noise from entering. Therefore all cables must be screened and the screen must be connected to ground. The screen of the cable connected to the Level Switch Ex should be connected to the ground terminal of the barrier. NOTE! The unscreened part of the cable should be kept very short (< 30mm) and the screen must be connected to ground. The diagrams below show how to connect Ex Level Switches and Ex Level Sensors to Ultrasound Controller via intrinsically safe zener barriers. Please look at the correct diagram. In the diagrams, the cable type between Ultrasound Controller and the barriers is the same type as between the barriers and the sensors. Choosing a barrier The barrier must be chosen according to EN 60079-14, but there are also measurement considerations for choosing the barrier: 1. The barrier must use resistive current limitation. 2. The barrier must be made for AC current. 3. Zener diodes inside the barrier must not connect directly between channels. 4. The barrier voltage should be as high as can be allowed. (minimum ±8V AC) 5. The barrier resistance should be as low as can be allowed. (maximum 110Ω) 6. The barrier must attenuate 2MHz as little as possible. 7. The barrier capacitance to ground should be as low as possible. 6

Ex-barriershields The zener barriers are not shielded so noise can interfere when weak signals are being measured. To reduce noise interference, shielding aluminium plates should be placed outside each group of barriers belonging to each Ultrasound Controller, see picture. Shielding aluminium plate must be ordered separately, item no: Ex-barriershield. The Ex-barriershield snaps on to the DIN-rail next to the intrinsically safe zener barriers. Intrinsically safe barrier for Ultrasound Controller, No. 1 Intrinsically safe barrier for Ultrasound Controller, No. 2 7 Level Switch Ex Manual

Intrinsically Safe Barrier Notice that Ultrasound Controller is not EX certified and ia-classified barriers must be used to connect the Level Switch Ex to The Ultrasound Controller. Common regulations for installation and maintenance of explosive protected electrical equipment shall be observed. (EN 60079-14 and EN 60079-17 in European countries connected to CENELEC). Special conditions for use according to certificate SP13ATEX3645X concerning the Level Switch Ex: 1. The cable from the barrier to the Level Switch Ex shall be permanently installed, mechanically protected and protected from other environmental stress in order to ensure explosion protection. A person with the required knowledge should perform installation. 2. The current limitation of the intrinsically safe barriers connected to the Level Switch Ex must be resistive with linear characteristic. 3. External source of heating and cooling shall be considered so that the ambient temperature is kept in the range -15 C to +60 C. 8

Connecting Level Switch Ex & Level Sensor Ex via barrier to D72 or DP72 9 Level Switch Ex Manual

Connecting Level Switch Ex & Level Sensor Ex via barrier to D128 10

Technical data Level Switch LS Ex Fit container diameter (mm) Level Switch KS Ex Fit container diameter (mm) Level Switch RS Ex Fit container diameter (mm) LS46 Ex 44 47 LS49 Ex 47 51 LS53 Ex 51 56 LS65 Ex 57 70 LS75 Ex 70 79 LS85 Ex 79 91 LS100 Ex 91 106 LS115 Ex 106 123 LS135 Ex 123 146 LS165 Ex 146 180 LS200 Ex 180 240 LS300 Ex 240 370 LS500 Ex 370 700 LS1300 Ex 700 2000 LSF EX Flat container wall KS27 Ex 26-28 KS30 Ex 29-31 KS34 Ex 32-35 KS38 Ex 36-40 KS42 Ex 40-43 KS46 Ex 44-49 KS53 Ex 50-57 KS65 Ex 58-69 KS75 Ex 70-79 KS85 Ex 80-89 KS115 Ex 98-135 KS165 Ex 135-200 KS250 Ex 201-350 KS600 Ex 351-1000 KSF Ex 1000-Flat RS27 Ex 26-28 RS30 Ex 29-31 RS34 Ex 32-35 RS38 Ex 36-40 RS42 Ex 40-43 RS46 Ex 44-49 RS53 Ex 50-57 RS65 Ex 58-69 RS75 Ex 70-79 RS85 Ex 80-89 RS115 Ex 98-135 RS165 Ex 135-200 RS250 Ex 201-350 RS600 Ex 351-1000 RSF Ex 1000-Flat Mounting screws: Material: Operating temperature range: -15 C to 60 C Maximum temperature: 60 C Transport temperature range: -15 to + 60 C LS Ex M2,5x20mm. KS Ex M4x >15mm. RS Ex M4x>40mm. plastic and stainless steel 316L Cable with connector WB-cable-7m 7m blue, 4x0,14mm² + screen, diameter 4,5mm Maximum cable length WB-cable-20m 20m blue, 4x0,14mm² + screen, diameter 4,5mm WB-cable-40m 40m blue, 4x0,14mm² + screen, diameter 4,5mm 40m The sensors are intended to use at normal atmospheric pressure (0,8-1,1 bar), normal oxygen concentration (21 %). 11 Level Switch Ex Manual

Dimensions Cable 90 Level Switch LSF EX Level Switch LS EX Level Switch RS Ex Level Switch RSF Ex Level Switch KS Ex Level Switch KSF Ex Cable 0 Level Switch Dimensions Comment Level Switch KS Ex Level Switch KSF Ex Level Switch RS Ex Level Switch RSF Ex L = 15mm R = fit container diameter L = 20mm R = flat surface L = 40mm R = fit container diameter L = 40mm R = flat surface Can fit a depression 8mm deep Can fit a depression 8mm deep Level Switch LS Ex See drawings Old version, only spare part. For new design use Level Switch KS Ex Level Switch LSF Ex See drawings Old version, only spare part. For new design use Level Switch KS Ex Ultrasound Controller D72 / DP72 D128 12

9. Manufacturer information Manufacturer: Address: Alsikegatan 4 SE-753 23 Uppsala Sweden Phone: +46 (0)18-18 34 30 Fax: +46 (0)18-10 50 04 Web: www.aqelteknik.com E-mail: aqelteknik@aqg.se Label information Level Switch Made in Sweden Type see Technical data Ex Class II 2G Ex ia IIB T4 Gb SP No. SP13ATEX3645X Intrinsic parameters Max input voltage Ui: 10,0V Max current input Ii: 250mA Max power input Pi: 1,1W Inner capacitance Ci: 200nF Inner inductance Li: 0,05mH EX description The Level Switch Ex is made to be used in Apparatus-group llb and Equipment-group 2G. The Level Switch Ex is classified for zone 1. Notice that Ultrasound Controller model D72/DP72/D128 is not EX certified and ia-classified barriers must be used to connect the Level Switch Ex to the Ultrasound Controller. 13 Level Switch Ex Manual

14