Multi-step Independent Component Analysis for Removing Cardiac Artefacts from Back SEMG Signals

Similar documents
Muscle Sensor KI 2 Instructions

Brain-Computer Interface (BCI)

Single Channel Speech Enhancement Using Spectral Subtraction Based on Minimum Statistics

Independent Component Analysis Methods to Improve Electrocardiogram Patterns Recognition in the Presence of Non-Trivial Artifacts

Motion Artifact removal in Ambulatory ECG Signal using ICA

Appendix D. UW DigiScope User s Manual. Willis J. Tompkins and Annie Foong

Department of Electrical & Electronic Engineering Imperial College of Science, Technology and Medicine. Project: Real-Time Speech Enhancement

Keywords Separation of sound, percussive instruments, non-percussive instruments, flexible audio source separation toolbox

DATA! NOW WHAT? Preparing your ERP data for analysis

Learning Joint Statistical Models for Audio-Visual Fusion and Segregation

POST-PROCESSING FIDDLE : A REAL-TIME MULTI-PITCH TRACKING TECHNIQUE USING HARMONIC PARTIAL SUBTRACTION FOR USE WITHIN LIVE PERFORMANCE SYSTEMS

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad.

ECG Denoising Using Singular Value Decomposition

Pre-Processing of ERP Data. Peter J. Molfese, Ph.D. Yale University

Lesson 1 EMG 1 Electromyography: Motor Unit Recruitment

Removal Of EMG Artifacts From Multichannel EEG Signal Using Automatic Dynamic Segmentation

Music Source Separation

A Novel Video Compression Method Based on Underdetermined Blind Source Separation

m RSC Chromatographie Integration Methods Second Edition CHROMATOGRAPHY MONOGRAPHS Norman Dyson Dyson Instruments Ltd., UK

Research Article. ISSN (Print) *Corresponding author Shireen Fathima

DELTA MODULATION AND DPCM CODING OF COLOR SIGNALS

BASE-LINE WANDER & LINE CODING

Detection and demodulation of non-cooperative burst signal Feng Yue 1, Wu Guangzhi 1, Tao Min 1

Digital Correction for Multibit D/A Converters

Reconstruction of Ca 2+ dynamics from low frame rate Ca 2+ imaging data CS229 final project. Submitted by: Limor Bursztyn

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio

2. AN INTROSPECTION OF THE MORPHING PROCESS

WAVELET DENOISING EMG SIGNAL USING LABVIEW

Identification of Motion Artifact in Ambulatory ECG Signal Using Wavelet Techniques

Chapter 1. Introduction to Digital Signal Processing

TERRESTRIAL broadcasting of digital television (DTV)

DETECTING NOISE IN SURFACE ELECTROMYOGRAPHY RECORDINGS

Investigation of Digital Signal Processing of High-speed DACs Signals for Settling Time Testing

Design of effective algorithm for Removal of Ocular Artifact from Multichannel EEG Signal Using ICA and Wavelet Method

Reinhard Gentner, Susanne Gorges, David Weise, Kristin aufm Kampe, Mathias Buttmann, and Joseph Classen

Object selectivity of local field potentials and spikes in the macaque inferior temporal cortex

University of Tennessee at Chattanooga Steady State and Step Response for Filter Wash Station ENGR 3280L By. Jonathan Cain. (Emily Stark, Jared Baker)

ECG ARTIFACT REMOVAL FROM SURFACE EMG SIGNALS BY COMBINING EMPIRICAL MODE DECOMPOSITION AND INDEPENDENT COMPONENT ANALYSIS

Study of White Gaussian Noise with Varying Signal to Noise Ratio in Speech Signal using Wavelet

COMP Test on Psychology 320 Check on Mastery of Prerequisites

Hidden Markov Model based dance recognition

OSL Preprocessing Henry Luckhoo. Wednesday, 23 October 13

A Parametric Autoregressive Model for the Extraction of Electric Network Frequency Fluctuations in Audio Forensic Authentication

STAT 113: Statistics and Society Ellen Gundlach, Purdue University. (Chapters refer to Moore and Notz, Statistics: Concepts and Controversies, 8e)

Getting started with Spike Recorder on PC/Mac/Linux

Noise Cancellation in Gamelan Signal by Using Least Mean Square Based Adaptive Filter

DAT335 Music Perception and Cognition Cogswell Polytechnical College Spring Week 6 Class Notes

Optimum Frame Synchronization for Preamble-less Packet Transmission of Turbo Codes

Analysis of Packet Loss for Compressed Video: Does Burst-Length Matter?

homework solutions for: Homework #4: Signal-to-Noise Ratio Estimation submitted to: Dr. Joseph Picone ECE 8993 Fundamentals of Speech Recognition

Environmental Controls Laboratory

Re: ENSC 370 Project Physiological Signal Data Logger Functional Specifications

Identification, characterisation, and correction of artefacts in electroencephalographic data in study of stationary and mobile electroencephalograph

BER MEASUREMENT IN THE NOISY CHANNEL

Lab 1 Introduction to the Software Development Environment and Signal Sampling

Noise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0

User Guide EMG. This user guide has been created to educate and inform the reader about doing EMG measurements

Music Similarity and Cover Song Identification: The Case of Jazz

A Parametric Autoregressive Model for the Extraction of Electric Network Frequency Fluctuations in Audio Forensic Authentication

Experiment 7: Bit Error Rate (BER) Measurement in the Noisy Channel

Agilent PN Time-Capture Capabilities of the Agilent Series Vector Signal Analyzers Product Note

ISCEV SINGLE CHANNEL ERG PROTOCOL DESIGN

DIGITAL COMMUNICATION

Instrument Recognition in Polyphonic Mixtures Using Spectral Envelopes

Nnyanzi, L.A. (2012) The national child measurement programme: its value and impact. Unpublished PhD Thesis, Teesside University

Supervision of Analogue Signal Paths in Legacy Media Migration Processes using Digital Signal Processing

PROCESSING YOUR EEG DATA

Broadcast Television Measurements

Precision testing methods of Event Timer A032-ET

Artifact Removal from Biosignal using Fixed Point ICA Algorithm for Pre-processing in Biometric Recognition

HBI Database. Version 2 (User Manual)

Heart Rate Variability Preparing Data for Analysis Using AcqKnowledge

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

Soundprism: An Online System for Score-Informed Source Separation of Music Audio Zhiyao Duan, Student Member, IEEE, and Bryan Pardo, Member, IEEE

Iterative Direct DPD White Paper

LOCOCODE versus PCA and ICA. Jurgen Schmidhuber. IDSIA, Corso Elvezia 36. CH-6900-Lugano, Switzerland. Abstract

System Identification

MUSI-6201 Computational Music Analysis

Microwave Counter, Power Meter and DVM in One Portable Package

ADINSTRUMENTS. making science easier. MA3300 Audio Monitor. Owner s Guide

Frame Synchronization in Digital Communication Systems

Reduction of Device Damage During Dry Etching of Advanced MMIC Devices Using Optical Emission Spectroscopy

Pitch. The perceptual correlate of frequency: the perceptual dimension along which sounds can be ordered from low to high.

Predicting the Importance of Current Papers

Psychophysiological measures of emotional response to Romantic orchestral music and their musical and acoustic correlates

Supplemental Material for Gamma-band Synchronization in the Macaque Hippocampus and Memory Formation

ni.com Digital Signal Processing for Every Application

Tutorial on Technical and Performance Benefits of AD719x Family

EEG Eye-Blinking Artefacts Power Spectrum Analysis

OBJECTIVE EVALUATION OF A MELODY EXTRACTOR FOR NORTH INDIAN CLASSICAL VOCAL PERFORMANCES

Using the new psychoacoustic tonality analyses Tonality (Hearing Model) 1

Optimization of Multi-Channel BCH Error Decoding for Common Cases. Russell Dill Master's Thesis Defense April 20, 2015

EE391 Special Report (Spring 2005) Automatic Chord Recognition Using A Summary Autocorrelation Function

MindMouse. This project is written in C++ and uses the following Libraries: LibSvm, kissfft, BOOST File System, and Emotiv Research Edition SDK.

For the SIA. Applications of Propagation Delay & Skew tool. Introduction. Theory of Operation. Propagation Delay & Skew Tool

Hybrid Wavelet and EMD/ICA Approach for Artifact Suppression in Pervasive EEG

APPLICATION OF A PHYSIOLOGICAL EAR MODEL TO IRRELEVANCE REDUCTION IN AUDIO CODING

MEE 1000A. For more than 50 years, healthcare. Neuromaster MEE-1000A Intra-Operative Monitoring System

EDDY CURRENT IMAGE PROCESSING FOR CRACK SIZE CHARACTERIZATION

AUDIOVISUAL COMMUNICATION

Transcription:

Multi-step Independent Component Analysis for Removing Cardiac Artefacts from Back SEMG Signals D Djuwari SECE, RMI University RMI City Campus, Swanston Street s3001068@student.rmit.edu.au D K Kumar SECE, RMI University RMI City Campus, Swanston Street dinesh@rmit.edu.au SC Ragupathy SECE, RMI University RMI City Campus, Swanston Street s2116958@student.rmit.edu.au B Polus LS, RMI University RMI Bundoora West Campus barbara.polus@rmit.edu.au Abstract he Electromyogram (EMG) signals recorded from the back muscles often contain large electrocardiogram (ECG) artefacts. For better interpretation of these SEMG signals, it is essential to remove ECG artefacts. his paper reports research conducted to address the problem of removing ECG artefacts from SEMG recordings using new approach of Independent Component Analysis (ICA) called Multi-step ICA. he technique isolates the ECG artefact first and then removes the ECG artefact from each channel and solves permutation problem simultaneously. he results have been validated using standard deviation reduction of the normalised RMS amplitude of the data after separation process. he results demonstrate that this new proposed technique is successful in removing ECG artefacts from SEMG signals. 1. Introduction Electromyogram (EMG) is the recording of the electrical activity of muscles. he EMG is usually recorded using monopolar or bipolar needle electrodes or surface electrodes. With needle EMG, it is possible to examine the activity of individual motor units while surface EMG (SEMG) is useful for examining the gross activity of a muscle or a group of muscles [6]. SEMG is a non-invasive technique and provides knowledge of the activation of the muscle of interest for a specific activity or posture and the relative strength of contraction [10]. One difficulty with SEMG is cross talk among the signals from adjacent electrodes and the recording of electrical activity from other sources. For accurate information of the activity of muscles it is important to ensure that SEMG is noise and artefact free and the recording represents the activity of the selected muscles. SEMG of lumbar erector spine muscles (LESM) has been used frequently in applied physiology for the assessment of back muscle function during various activities [9]. Researchers have attempted to use the magnitude of the SEMG for the analysis of the relative

strength of contraction of the paraspinal muscles for the diagnosis of lumbar back ailments [1]. However, SEMG of lumbar paraspinal muscles may record the activity from several different muscles during static postures. Before the clinical and research utility of the SEMG for this task can be assessed, it is essential that issues of reliability and validity of the SEMG of lumbar paraspinal muscles be addressed. he ability of the SEMG to reliably record the relative strength of contraction of specific lumbar paraspinal muscles during the maintenance of a specific static posture is an important preliminary step in the validation procedure. During SEMG recordings of multifidus muscle activity in different static postures the reliability of the SEMG signal is a major concern with issues such as electrode placement and high noise content in the recordings needing to be addressed. he development of a reliable objective measure of muscle activity would allow investigation into treatment outcomes and the role of muscle dysfunction in the maintenance or generation of LBP [9]. Recordings of SEMG from the back and abdomen muscles are contaminated by strong ECG signals making the raw signal unsuitable for analysis, confirming the findings of other researchers [11]. herefore a technique to remove ECG artefact from SEMG recordings of the back is essential. he commonly used techniques to remove noise such as high-pass filtering [13], spectral filtering [8], gating and cross-correlation subtraction [3] are not suitable. Each of these techniques has drawbacks that make them unsuitable for this application. Due to spectral overlap between ECG and SEMG, frequency filtering is unsuitable for this purpose. Gating, removing or deleting part of the SEMG that contains ECG adds discontinuities and makes the output unreliable since there must be some discontinuity in the joint point. Further, this technique is based on removing the QRS complex from the signal, often not the only source of contamination. ECG and SEMG are statistically independent signals. hus Independent Component Analysis (ICA) can be used to remove ECG artefact from SEMG recordings. ICA is a technique used to estimate two independent signals from a mixture of the two signals based on their independence to each other. It has been used to estimate and separate breathing artefacts from ECG recordings and results demonstrate the enhancement of cardiac signal quality with the use of ICA technique [16]. It has also been used to estimate and separate ECG artefact, noise and pure SEMG signal from synthetic mixture signals (one pure ECG signal and any two EMG signals that were linearly combined using 3x3 mixing matrix) using fixed-point algorithm but not with the real raw EMG signals from the recording [15]. A recently published paper reports success in the application of ICA to detect the underlying functional muscle activations during swallowing and successfully detect the presence of ECG and exclude it from the analysis. ICA was used to separate the 8 largest principle components of raw SEMG to obtain the signals representing each of the independent sources [11]. he ICA techniques described above were used in situations where the number of sources and recordings were the same. hese methods are suitable where the prior knowledge of the type of independent component is known (such as pure ECG, abrupt signal and white noise) [14]. he other shortcoming of ICA is the ambiguity in permutation and amplitude [5]. hus, ICA in the conventional form is not suitable for removing the ECG artefact from pre-recorded data where there is no extra channel that has simultaneously recorded ECG along with SEMG. his paper presents a modification of ICA to overcome the shortcomings mentioned above. his technique successfully removes the ECG artefact from SEMG recordings from the muscles of the lumbar back. It overcomes the ambiguity of the permutation and amplitude and does not require an extra channel recording of ECG in parallel with SEMG. his is important for the analysis of the muscle activation for posture control. 1.1 Independent Component Analysis (a brief) ICA was originally developed to deal with problems that are similar to the cocktail party problem. In a simplified situation, imagine 4 people are sitting together and talking to each other in a room that is equipped with 4 randomly distributed microphones. Each microphone will record a mixture of the 4 voices but with a different composition based on the relative location. he objective of ICA is to estimate the individual voice of each person, given only the recorded signals from those 4 microphones without having any knowledge about their location or their speech properties. Using ICA, the four recordings are separated to provide four sound signals that are independent to each other and thus are from each of the four speakers by suitably remixing the recordings. ICA is based on some fundamental assumptions. Some of these have been listed below: he first assumption is that the number of mixtures is greater than or equal to the number of independent sources. he mixtures are linear combinations of the sources and there is no delay or external noise included. he sources are stationary and are not moving during the recording process.

here is a constant effort by research groups to overcome the limitations of these assumptions. A basic formulation of ICA can be expressed mathematically as [5]: x x 1 () t = a11s1( t) + a12s2 ( t) () t = a s ( t) + a s ( t) 2 21 1 22 2 (1) If the contrast function g(u) = tanh(u) then: H ( y) W W W = [ I + 2 tanh( u) u ] W (5) W his is the learning rule used in the ICA algorithm to separate different sources from mixed recordings. or in general form (matrix notation) x = A*s, (2) where x is the vector of the mixtures, A is the unknown mixing matrix, and s is the vector of unknown independent components. he goal of ICA is finding an unmixing matrix W=A -1 using neural networks. Bell and Sejnowski have proposed a simple ICA algorithm based on an information maximization approach or minimization of mutual information among the outputs of neural network [4]. Mutual information is a natural measure of the dependence between random variables. he greater the mutual information, the more dependent are the variables. For this purpose, it is important to determine a suitable contrast function g(u) for the neurones of the network because the high density part of the probability density function (pdf) of x should be aligned with highly sloping part of g(u). Mutual information of the output vector y is defined as [5]: I( y1, y2,..., yn ) = H ( yi ) H ( y) n i= 1 Bell and Sejnowski have shown that minimizing mutual information I(y) among the output components is equal to maximizing their joint entropy H(y) with respect to the weighting matrix, W. he learning ruled derived by maximizing this joint entropy with respect to W is [7]: (3) H ( y) W W W = [ I + pu ] W (4) W 1.2 Multi-step ICA he ICA technique has certain limitations such as lack of certainty of permutation and amplitude of the independent components. When applied to remove biosignal artefacts, the need for ICA to have as many channels as sources becomes a major limitation, as it requires an extra recording channel that would provide the information of the artefact. hus it is not possible to apply ICA directly to remove the ECG artefact from 4 raw SEMG signals with the goal to obtain 4 clean SEMG signals. If the input of ICA algorithm is 4 raw EMG signals, the output will be 4 independent components where one of them is the ECG component while the other three are mixtures of the 4 EMG signals and are unsuitable for further analysis. herefore, a new approach is needed in this situation to solve the problem. he technique proposed here is called Multi-step ICA since it uses more than one step to get the clean EMG signals. he rationale of this is based on the fact that ECG is an independent signal that appears in each channel and identifying this would provide us information for the fifth channel. he detail description of this method is shown in figure 1. In the first step, the four raw SEMG signals from each channel are given as the input of ICA algorithm. he output of this separation process is 1 pure ECG signal and 3 SEMG mixture signals. Because of permutation problem of ICA, a short algorithm was used to get the pure ECG part for further processing. his algorithm discards the peak amplitude of abrupt noise by applying a 10-point moving average filter, detects the R-S value of the ECG that is much higher than any other part of the separated signals and gets the index of ECG signal. he ECG now becomes the first independent component that obtained from this ICA step. where yi p = ln and u = W*x. ui ui

#1 EMG 1 st step #2 #3 ICA EMG ECG #4 EMG Raw EMG Unclean EMG and pure ECG ECG 2 nd step #N Raw EMG and pure ECG ICA #N ECG Clean EMG and pure Figure 3: One ECG and three mixed SEMGs as the output of the first step ICA Figure 1: Cardiac artefact removal procedure by Multi-step ICA Figure 4: Four clean SEMGs as the output of the second step ICA Figure 2: Four raw SEMG signals as an input to the first step ICA he second step has one raw SEMG signal from a single channel and the ECG signal obtained from the previous process as the input to the ICA algorithm. he output of this process is 1 pure ECG and 1 clean SEMG for the particular channel. A similar algorithm as used in the previous step was used to detect the clean SEMG signal. his process is repeated for all the channels. Figure 2, 3 and 4 illustrate the waveform of the raw signals, first and second step ICA outputs respectively. 2. Materials And Methods 2.1 SEMG Recordings SEMG recording was done using a 4-channel PowerLab data acquisition system (ADInstrument, Castle Hill, NSW, Australia) on 11 subjects on 2 days. he subjects were healthy males and females with ages ranging from 20 to 60 years old. he sampling rate was selected at 1000 sample/second and with antialiasing, high pass and notch filters having cut-off at 200 Hz, 3 Hz and 50 Hz respectively. he 4 channels were connected to 4 surface electrodes attached on the back muscles located on the left (ch.#3 and ch.#4) and right (ch.#1 and ch.#2) sides of the

spinal cord. he recording was done while the subjects were in specified normal sitting and standing positions. It was observed that most of the SEMG recordings were a mixture of SEMG and ECG. It was also observed that often the ECG (the artefact) strength was much greater than SEMG signal. A total of 31 recordings (containing 4 channels) were used for this experiment. 2.2 Signal Analysis All SEMG recordings were saved in a *.txt format and then transferred to Matlab (Mathworks.Inc) for further processing. he ICA algorithm developed by Bell and Sejnowski [4] was used in the first and second step ICA calculation. he proposed technique Multi-step ICA explained above was applied to each SEMG recording to remove the ECG artefact. he outputs of this artefact removal process were saved again in the text format for further statistical analysis. 2.3 Validation of Results SEMG, based on changes in amplitude and frequency, is a useful indicator for the strength of muscle contraction and muscle status. Comparison of SEMG magnitude from different locations of the back has been considered as a useful indicator of the relative contraction of the lumbar muscles and for information regarding posture control of the subject. Root Mean Square (RMS) is considered to be a good indicator of the strength of contraction of the muscles. he RMS amplitude (energy) of a signal x(n) is defined as [2]: 1 N { ( )} = 1 2 x n x ( n) RMS (6) N 1 0 With the presence of ECG in the SEMG, the RMS of SEMG may have a very strong dependence on ECG and the information from this may not be reliable. But Melaku and Kumar have demonstrated that the RMS magnitude of the SEMG varies between subjects and between different recordings for the same subject and hence is not a suitable measure for improved reliability [12]. hus, to determine any improvement in the reliability of the recordings using modified ICA for ECG removal, the reduction in the interrecording variation is a suitable measure. 3. Results And Discussion 3.1 Results RMS values of all raw SEMG recordings and clean SEMG signals after ECG artefact removal were calculated using (6). hese values were then normalised by the value of the first channel of each recording to observe the relative muscles contraction for different postures. he mean, standard deviation and the ratio between standard deviation and mean of those normalised values were calculated. hese are displayed in table 1 and tabel 2. able 1. Mean, SD and SD/mean values of the normalised data before and after separation for standing posture Raw SEMG signals Multi-step ICA output Ch1 Ch2 Ch3 Ch4 Ch1 Ch2 Ch3 Ch4 µ 1.0000 0.5425 0.7342 0.4225 1.0000 1.0100 1.0169 1.0562 σ 0.0000 0.0870 0.2207 0.1299 0.0000 0.0558 0.1141 0.1077 σ /µ 0.0000 0.1603 0.3006 0.3075 0.0000 0.0552 0.1122 0.1019 able 2. Mean, SD and SD/mean values of the normalised data before and after separation for sitting posture Raw SEMG signals Multi-step ICA output Ch1 Ch2 Ch3 Ch4 Ch1 Ch2 Ch3 Ch4 µ 1.0000 0.5698 0.9199 0.5593 1.0000 1.0111 0.9895 1.0041 σ 0.0000 0.3806 0.4459 0.2686 0.0000 0.0580 0.0502 0.1004 σ /µ 0.0000 0.6680 0.4848 0.4803 0.0000 0.0573 0.0507 0.1000 3.2 Discussion he analysis above provides evidence that ECG artefact removal using this new approach of ICA gives a convincing result. he decrease of standard deviation shows that after ECG artefact removal the variance of the signal is less then the raw SEMG. he ratio between standard deviation and mean demonstrates that the output of the separation has less Gaussian distribution. his means that the output signals are independent to each other.

his approach of ICA is suitable when there are fewer channels than sources and in situations where the signal / artefact that needs to be removed appears in all channels. he permutation ambiguity was also solved by applying ICA to each channel in turn while the magnitude ambiguity was equalised by a post processing step that makes the separated sources have unit variance. hus, this technique gives more reliable SEMG signals for quality interpretation. With raw SEMG signals, it is hard to determine which muscles contribute more or less during a certain static posture. he disadvantage of this technique is the increased computational time required to accomplish the separation task because of multi-step processing. Further, this technique is dependent on the artefact having a distribution that differs from the rest in the mixtures. he extension of this technique is to estimate a greater number of sources than the number of sensing channels. 4. Conclusion From visual inspection of the output signals (Figure 4) and from the statistical analysis result, it is clear that this new approach of Multi-step ICA is able to remove the cardiac artefact from SEMG recording and give more reliable signal for clinical interpretation. 5. Acknowledgments he authors want to thank Ken Mei who has contributed much in the SEMG recording and all-fellow researchers in the Biomedical Laboratory, School of Electronics and Computer Engineering, RMI University for their support. 6. References [1] Ambroz C, Scott A, Ambroz A and albott EO, Chronic Low Back Pain Assessment Using Surface Electromyography, JOEM, 42 (6), 660-669, 2000. [2] Barney L and Gunnar A, Selected opics in Surface Electromyography for Use in the Occupational Setting: Expert Perspective, DHHS (NIOSH) Publication, Chapter 5, No. 91-100, 1992. [3] Bartolo A, C.R., R.Dz, and Goldman E, Analysis of Diaphragm EMG signals: comparison of gating vs. subtraction for removal of ECG contamination, American Physiological society, 1996. [4] Bell AJ and Sejnowski J, "An information-maximization approach to blind separation and blind deconvolution", Neural Computation, Vol. 7, No. 6, 1129-1159, 1995. [5] Hyvärinen A and Oja E, Independent component analysis: algorithms and applications, Neural Networks, 13 (4-5), 411-430, 2000. [6] Kimura J, Electrodiagnosis in diseases of nerve and muscle: principles and practice, 2 nd edition, Philadelphia: F.A Davis, 1989. [7] Lee W, Girolami M and Sejnowski J, Independent Component Analysis Using an Extended Algorithm for Mixed Subgaussian and Supergaussian Sources, Neural Computation, 11, 417-441, 1999. [8] Levine S, J.G., Weiser P, Gillen M and Kwatny E, Description and validation of an ECG removal procedure for EMG, Power Spectrum Analysis, Journal of Applied Physiology, 60, 1073-1081, 1986. [9] Marcarian D, Surface EMG: Static vs. Dynamic esting, Canadian Chiropractor, 32-33, 1999. [10] Marras W, Selected opics in Surface Electromyography for Use in the Occupational Setting: Expert Perspective, DHHS (NIOSH) Publication, Chapter 1, No. 91-100, 1992. [11] McKeown MJ, orpey DC and Gehm WC, Non-invasive monitoring of functionally distinct muscle activations during swallowing, J. Clinical Neurophysiology, 113, 354-366, 2002. [12] Melaku A, Kumar DK and Bradley AB, Influence of Inter-Electrode Distance on he RMS of SEMG signal, Electromyography and Clinical Neurophysiology, 41, 437-442, 2001. [13] Redfern MS, Hughes RE and Chaffin DB, High-pass filtering to remove electrocardiographic interference from torso EMG recordings, Clinical Biomechanics, 8 (1), 44-48, 1993. [14] aigang H, Clifford G and arassenko L, Application of ICA in Removing Artefacts from ECG, Neural Computing and Applications, 2002. [15] Wachowiak M, Smolikova R, ourassi GD and Elmaghraby AS, Separation of Cardiac Artefacts from EMG Signals with Independent Component Analysis, Biosignal, 2002. [16] Wisbeck JO, Barros AK and Ojeda R, Application of ICA in the Separation of Breathing artefacts in ECG Signals, Int. Conf. on Neural Information Processing (ICONIP 98), 1998.