Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Access door to stage from scene dock - 2.9m by 2.9m.

Similar documents
Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

Latrobe Performing Arts Centre

Matt Dann Cultural Centre

John Leslie Theatre. Technical Specifications. Updated July 2018

Esso BHP Billiton Wellington Entertainment Centre

2017 TECHNICAL SPECIFICATIONS

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

Yan Yean Theatre Technical Specifications

Mildura Arts Centre. Mildura Arts Centre Theatre. Technical Specifications. Updated 23/6/06

Monash Academy of Performing Arts

Monash University Academy of Performing Arts

MONASH University Academy of Performing Arts

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

RPAC REDLANDS PERFORMING ARTS CENTRE

THE STREET THEATRE. Technical Specifications

D A R E B I N A R T S & E N T E R T A I N M E N T C E N T R E

CENTRE FOR PERFORMING ARTS

Orange Civic Theatre

Dr JOHN GALLAGHER CONCERT CHAMBER

Technical Specifications

Technical Specifications

Don Russell Performing Arts Centre

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Main House Technical Specification

DEREHAM MEMORIAL HALL

The Haymarket Basingstoke Technical Specifications

THEATRE Technical Specifications

Technical Specifications

Alexander Theatre. Technical Specifications. Monash University VIC enter via Wellington Road

Monash Academy of Performing Arts (MAPA) Alexander Theatre. Technical Specifications

Technical Specification Pavilion Dance

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Darebin Arts & Entertainment Centre. Theatre

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Technical Services and Specification

Queensland Performing Arts Centre

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Technical Specification

Theatre Technical Specifications

Gosford City Council

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Theatre Technical Specifications

Technical Specifications

TECHNICAL SPECIFICATIONS RIVERSIDE THEATRE

Powerhouse Theatre technical information and general specifications 2017

HIRE AND TECHNICAL INFORMATION

ISLAND HALL TECHNICAL INFORMATION

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

Technical Informa on.zack Theater

Sandusky State Theatre Technical Specifications

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.

Visy Theatre technical information and general specifications 2019

TECHNICAL SPECIFICATIONS: STICKS STONES BROKEN BONES Company: Bunk Puppets, contact :Jeff Achtem,

Bathurst Memorial Entertainment Centre Theatre Technical Specifications 2014

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

CHELSEA THEATRE. Technical Specifications

TECHNICAL PACKAGE.

Technical Specification for the Alley Theatre, Strabane

VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

Access to back stage is off Fletcher St on the eastern side of the building

Technical Facilities Description. Egyptian Theatre. 135 N. Second Street DeKalb, Illinois 60115

Technical Information

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Technical specifications Main theatre. Sound

Amarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101

Technical Information

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

TECHNICAL SPECIFICATIONS

Patriots Theater at the War Memorial Technical Data

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Project manager (PM): Pamela Næss Mail: Phone:

Concert Hall Technical Specifications

There are 10 dressing rooms in Theatre Kerkrade.

Dr. Fred Speckeen Theatre. Information and Technical Specifications

Summary. Access and Parking

Technical Specifications. Taylor Little Theater

New Theatre Royal Lincoln Technical Information

Darlington Hippodrome Technical Specification

BANYULE THEATRE TECHNICAL INFORMATION. 10 Buckingham Drive Heidelberg VIC Page 0 of 10

Technical Specification

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Facility Information

Generated from the APACA Technical Specifications Template. For more details visit Clocktower Centre.

Technical Specifications

Technical Pack. Attenborough Arts Centre

TECHNICAL RIDER. STAGE 32 m wide x 13 m deep (from setting line / mid point)

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Technical Specifications

Technical Specifications and Inventory Spring 2018

Arcadia Performing Arts Center Technical Specifications and Information

Pleasance London Main House Visiting Company Information Pack May 2017

Transcription:

Technical specifications STAGE Brief stage description Stage one: The Cube is a flat floor, multipurpose space with a retractable seating bank and balcony seating. There is no proscenium arch or fly tower (10 meter ceiling). The surface is hardwood floor covered with Masonite sheets. There is a removable seating/orchestra pit, which seats an additional 69 patrons or space for an orchestra. (Manual pit lid removal) The venue has a front of house curtain, mid tab and rear tab curtains, as well as side leg curtains, with all lighting bars on motors, spare lines on hand winches. Stage point load limit: Stage point load of 700kg Stage two: Modular staging 1m x 2m sections total of 80m 2. Stage height 500 to 800mm with disabled access ramp. These staging units are covered in grey carpet. Stage rake: No Stage dimensions Non-proscenium stage Theatre stage: Width 14m Depth 10m Modular stage: 80m 2 of modular staging at two heights of 500mm to 800mm. Access door to stage from scene dock - 2.9m by 2.9m. Setting line 200mm upstage from the fire curtain. Distance from (SL = Setting line, CL = Centre line) SL to DS edge of orchestra lift/pit 800mm SL to first fly line 350mm SL to last upstage fly line 8.7m SL to rear wall 9.7m CL to OP wall (or obstruction) 9.4m CL to PS wall (or obstruction) 9.4m Stage to underside of grid 7m PLEASE NOTE: This may be different to the batten drift measurement.overhead obstructions N/A thecubewodonga.com.au 1 of 11

AUDITORIUM The auditorium consists of a retractable seating system with a level one balcony. Seating capacity with additional seating pit installed and balcony - 410 Seating capacity without seating pit and seats added on the flat floor with a reduced stage can see a seating capacity 550. ORCHESTRA LIFT/PIT Orchestra pit The venue has a dual purpose seating/orchestra pit. It can be used to seat up to 25 orchestra members, but will reduce the seating capacity of the venue by 69 patrons. Depth of pit is 1.5m Width of pit is 17m Length of pit is 3m DRAPERY Type Material Colour Width Height Quantity House curtain Wool, 50 per cent / 500gsm Black 10.3m 9.5m One pair Borders Legs Valance Travellers Wool, 50 per cent / 500gsm Wool, 50 per cent / 500gsm Wool, 50 per cent / 500gsm Wool, 50 per cent / 500gsm Black 14.8m 3.5m Five Black 2.4m 7.8m Three pair Black 20m 3.5m Two Black 7.5m 7.8m Two pair thecubewodonga.com.au 2 of 11

HANGING PLOT SL: Setting line as indicated previously Line type: SP = Single purchase, DP = Double purchase, MW = Motor winch, HW = Hand winch, HL = Handline W.L.L.: Maximum distributed load including bar weight PLEASE NOTE: All legs are dead hung. Line no Distance from SL (mm) Line type W.L.L Venue allocation 1 DH Front of house (FOH) curtain 2 100 Fixed NA Border 3 500 MW 45kg/m LX one 4 1100 MW 500 Sq truss (5m) 5 1700 DH NA Web Truss (dead hung) 6 1800 DH NA Legs two 7 2000 HW 420 Border 8 2800 MW 500 Sq truss (5m) LX three 9 3600 DH NA Border 10 3750 DH NA Legs three 11 3900 HW 420 Mid-stage traveller 12 4350 MW 500 LX four 13 5100 MW 500 Sq truss (5m) 14 5800 HW 420 Web truss 15 6900 DH NA Border 16 7000 DH NA Legs four 17 7100 MW 500 LX five 18 7900 HW 420 Rear traveller 19 8100 HW 420 Web TR 20 8200 HW 420 CYC ACCESS EQUIPMENT Elevated: work platform Snorkel s3246e Scissor Lift. (1.5m x 2.5m) Maximum drive speed (extended).8km/h Maximum drive speed (stowed) 3.2km/h Maximum reach is: Platform height is 9.75m Maximum reach is 11.8m EWP restrictions Use is at the discretion of The Cube technical co-ordinator. Ladders: Six foot A frame aluminium ladder Lift pod - working height of 4.2 meters thecubewodonga.com.au 3 of 11

STAGING UNITS Power stage: 40 stage sections 1m by 2m, heights of 500mm for 40 square meters of stage area and 800mm for 80 square meters of stage area. LOADING DOCK Access: Truck access off Hovell St to loading dock at rear of building. Loading dock height - 4.5m Door dimensions - 4m (high) by 3.5m (wide) ADDITIONAL RIGGING NOTES LIGHTING 11 rigging points in auditorium floor and stage, request additional information from the venue if required. Positions On Stage LX bars: Fixed single bars and box truss. PLEASE NOTE: See hanging plot for standard LX bar locations. Orchestra bar Box truss Setting line to lighting bar: Distance is adjustable from setting line. Height of 8.5m. Usable bar width: 14.2m FOH bridge one - Moveable Setting line to lighting bar: 15.3m Usable bar width: 14.1m FOH perches (PS and OP) Setting line to FOH perch: LX bar runs horizontally around the balcony floor and handrail of second level. FOH booms (PS and OP) Setting line to FOH boom: LX bar runs horizontally around the balcony floor and handrail of second level. PLEASE NOTE: Distances are to the highest downstage point of boom or perch. thecubewodonga.com.au 4 of 11

Control Lighting desk: Primary desk Vista T2 Secondary desk: ETC Ion Control channels: Up to 8192 channels (16 universes) Signal output: 4 DMX outputs, 1 Ethernet/Network port Signal distribution: 2 DMX universes available at various locations on each level throughout auditorium. Remote riggers available onstage: Ipad controller. Dimmer racks Dimmer quantity: 120 (10 racks at 12 dimmers each) Dimmer locations: Dimmer room located at balcony level above stage OP side, two additional dimmer racks are available on request. These can be relocated to the stage or where required. Per dimmer Va : 2500 House lights Independent control: Dynalite LED house lights Control positions: Stage OP and P sides, bio box, rear of auditorium floor level, box office Fade time adjustable: Yes Profiles Make Model Angle Detail/ accessories ETC ETC Source four zoom spot Source four zoom spot Watt 15-30 750 12 25-50 750 24 Total thecubewodonga.com.au 5 of 11

Fresnels Make Model Detail/ Wat Total accessories t ETC Source four fresnel Barn doors 750 24 ETC Source four ParNel 575 10 Par cans Make Model Angle Detail/ accessories ETC LedTechnik pro par three Source four PAR LED pro PAR 64 tri-colour Watt Total 750 23 6 Movers Make Model Control Detail/ Wat Total channels accessories t Varilite VL1100TID 20 Gobo 1100 6 Terbly Rockwash 12 6 Followspots None on site. Available for external hire upon request. Patching Location QTY Numbering (PS to OP) Detail/accessories DS PS 12 47-59 Eight by 10amp GPOs available MS PS 4 43-46 US PS 12 31-42 Four by 10amp GPOs USC 4 29-30 Four by 10am GPOs OS OP 16 13-28 Eight by 10am GPOs DS OP 12 1-12 Eight by 10am GPOs available FOH (ground) 20 OP 111-118 10 by 10amp GPOs PS 101-108 FOH level one 36 OP 301-316 12 by 10amp GPOs PS 325-340 Level one mix 4 319-322 8 by 10amp GPOs position FOH level two 32 501-532 12 by 10amp GPOs PS FOH level two 32 537-568 12 by 10amp GPOs OP thecubewodonga.com.au 6 of 11

Level twomix position Gallery PS 4 533-536 12 by 10amp GPOs Four by 10amp GPOs Gallery US 16 465-480 Two by 10amp GPOs Gallery OP LX one 16 401-416 LX two 16 481-496 LX three 16 433-448 LX four 16 417-432 LX five 16 449-464 Two by 10amp GPOs POWER Three-phase outlets: Three by 40amp OS PS Three by 40amp plus one by 40amp Green OS OP Three by 40amp FOH level one Two by 40amp FOH level two Two by 40amp gallery CABLING 240v extension cable: The venue has a good stock of extension leads to accommodate the venue s standard lighting rig. Any additional equipment may require additional cable stock to be sourced. Looms: Theatre has a good stock of looms in various lengths. AUDIO Control positions Control room: Standard position is at Tech level (level 2) above balcony. But multiple sites available for operating audio, lighting and AV. Auditorium: At lower floor level, centre rear of auditorium, DSOP and DSP sides of stage middle of flat floor space. Other: Rear of audience balcony (level one). Control and amplification Primary mixer: Soundcraft Si Compact 32 channel FX: Lexi con MX400 Compression/limiter/gates: Yes/inbuilt in Si Compact. Speakers FOH speakers: JBL VRX 932 LAP JBL VRX 918 SP thecubewodonga.com.au 7 of 11

Foldback: JBL PRX 512MI Stage monitor x6 Playback: Item Make Model Detail Total CD player Tascam SS-CDR200 2 Microphones: Make Model Detail/ accessorie Use Shure Beta 58A Vocal 4 Shure Beta 57 Instrument 4 Shure Beta 52 Dynamic 1 Shure ULX/S Radio mic lapel/ headset Shure MX202 Choir mic 4 Shure KSM137 Condenser mic Accessories: Item Model Detail/ accessories Mic stand - straight 4 Mic stand - boom 6 Mic stand - short 4 Line patching: Location Orchestra pit 10 Quantity Numbering Sends/Returns Detail Total 4 2 Total Eight sends, two returns Onstage 16 7-22/155-170 Eight sends, eight returns Level two OP 16 33-36/181- Eight sends, eight returns 184 Level two PS 8 37-40/185- Four sends, four returns 188 Level two seating 4 41-44/41-44 Four sends, four returns Cabling: Audio cable Venue has a selection of audio cables suitable for small events. Additional available on request. Audio notes Front of house speakers are dead hung and sit down stage of setting line, front fill speakers are available for use when seating pit is used.. thecubewodonga.com.au 8 of 11

AUDIO VISUAL Projectors: Type Model Detail/accessories Total Optima EH7500 WT91 1.45-1.94:1 1 Screens: Projection screen - front rear projection screen: 14m x 7.7m Portable screen - fast fold183 diagonal HDTV (16:9) format 8 2 x 13 11 Switcher scaler kramer VP747 Proscale Projector rigging points: Projector has a mounting assembly and can be rigged from most horizontal lighting bars. BACK STAGE Communications Stage manager s desk: Stage manager s desk can be positioned on either PS or OP side of stage. It can also be relocated to the technical position on either level one or level two. It is fitted with two monitors, lights, a clock, a timer, comms and paging microphone. Talkback: Master unit: Telex BTR 80N Total substations: 9 Wireless talkback sets: 5 Clearcom belt packs and headphones: 4 Paging /show relay: Paging to the dressing rooms is available from the stage manager s desk. Show relay is distributed to all dressing rooms and green room. Each room has an individual volume control. Stage monitor: Camera with inferred is located centre of the balcony bar. Monitor on stage manager s desk. Feed available to all areas. thecubewodonga.com.au 9 of 11

Dressing rooms Dressing room Dressing room one Capacity Toilets Showers Details Three Yes, accessible Yes Fully accessible dressing room Dressing room two Dressing room three Fifteen Fifteen Shower and toilet access across hallway Shower and toilet access across hallway Laundry/wardrobe Washing machines: One Dryers: One Drying rooms: N/A Iron/ironing board: One Clothes racks: Two Production facilities Production desk: Available upon request Production office: No Phone: Available on request. Fax: Available on request. Internet access: Free Wi-Fi is available throughout the venue. Green room Tea/coffee facilities: Yes, on request Fridge/freezer: Yes Microwave: Yes Running water: Yes Stage door Access: Stage door is located near the loading dock on Havelock St. Access to be negotiated through venue. thecubewodonga.com.au 10 of 11

VENUE Venue address The Cube, 118 Hovell St,, VIC 3690 Postal address The Cube, PO Box 923,, VIC 3689 Website thecubewodonga.com.au Staff contacts Technical co-ordinator Adrian Yates Phone: (02) 6022 9333 Mobile: 0403 601 946 Email: ayates@wodonga.vic.gov.au Team leader Rebecca Bennell Phone: (02) 6022 9223 Mobile: 0418 558 267 Fax: (02) 6022 9643 Email: rbennell@wodonga.vic.gov.au PLEASE NOTE: Document correct as at November 5, 2014. thecubewodonga.com.au 11 of 11