MAJESTIC (Circus Tent)

Similar documents
MAJESTIC (Circus Tent)

National Folk Festival PA Specs 2018 MARQUEE

The Standard Bank Studio is a music venue made from the choir stalls and the stage of the Cape Town City Hall Auditorium. It

Little River Band Production Rider 2018

Artist: Michael and Amy

TECHNICAL REQUIREMENT FORM

Theatre Royal Pre-Production Requirements

VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

Capacity: 60 2 Roxburgh Place, EH8 9SU. Assembly Roxy - Downstairs

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Visy Theatre technical information and general specifications 2019

YOUR TOOLKIT TO AMPLIFY YOUR SHOW

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

ISLAND HALL TECHNICAL INFORMATION

Matthew Flinders Theatre

Not Fade Away. The Ultimate Buddy Holly Experience. TECHNICAL RIDER Video Projection is Recommended

Treefort Music Fest- March Festival Information Main Stage

ROSE THEATRE MAIN THEATRE

New Theatre Royal Lincoln Technical Information

Rider Part1: Technical Requirements, A Cappella Show

SECREST AUDITORIUM TECHNICAL PACKAGE

ROSE THEATRE BASEMENT

Please carefully read this entire form before completing any information.

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Irish Heartbeat TECHNICAL RIDER. Video Projection Requested

SIMON & GARFUNKEL THROUGH THE YEARS TECHNICAL INFORMATION PACK

Technical requirements & conditions for hirers

DANCE BASE TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Matt Dann Cultural Centre

Health & Safety. For your Event.

DEREHAM MEMORIAL HALL

Section A: Front of House (FOH) Public Address (PA) Speaker System

City of Villa Rica 2016 Sound and Lighting. THE MILL amphitheater

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Technical Specification for the Alley Theatre, Strabane

Dr JOHN GALLAGHER CONCERT CHAMBER

VCE VET MUSIC TECHNICAL PRODUCTION

TOWER THEATRE TECHNICAL INFORMATION & GENERAL SPECIFICATIONS 2014 PLEASE DIRECT ALL ENQUIRIES TO THE OPERATIONS MANAGER:

Technical Rider Vocal Point Season Performing Arts Management

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Hospitality & Production Rider Artist: Dead Floyd General Terms: Billing- Support- Complimentary Tickets- Security- Insurance-

Get Funked Compact 6-piece. Technical Rider 2017/18. Contents Page 1/2 Technical Rider Page 3 Channel List Page 4 Monitor List Page 5 Stage Diagram

Technical Pack. Attenborough Arts Centre

Amarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101

The Willoughby Brothers

Paradiso (ch. Václav Kuneš) (30min) Technical requirements / List of light equipment Focus sheet on demand - (standard focusing)

THEATRE INFORMATION PACK

Gilded Balloon s Basement Theatre is a brand new 120 capacity theatre space in the heart of Edinburgh s West End.

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

Technical Information

BPM KREW 2013 Technical and Hospitality Rider For Large College/ University Performances

INFORMATION PACK & SCHEDULE OF RATES 2015

PSYCHIC SALLY PRODUCTION RIDER & FOH REQUESTS (UPDATED 2016)

REQUEST FOR QUOTE SOUND & LIGHTING for Volunteer Awards Banquet and July 3 rd Fireworks. PROPOSAL NUMBER: Q17-001PR ISSUE DATE: February 1, 2017

Marist Auditorium. Facility Guide

JERWOOD VANBRUGH THEATRE

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Our History. Clara Hughes Brott Music Festival Gail Vaz-Oxlade Jimmie Vaughan CBC Townhalls Hamilton Philharmonic Youth Orchestra Wild Kratts

VENUE TECHNICAL REQUIREMENTS

Atlanta Audio Services Information Sheet

UNIVERSITY CONCERT HALL. Technical Specification

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

CHELSEA THEATRE. Technical Specifications

Peacock Theatre. Industry Learning in Action. Salamanca Arts Centre

The Breen Center for the Performing Arts Saint Ignatius High School

RHAPSODY & RHYTHM Technical Rider

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Centre Stage and City Room at Surrey City Hall Venue Information

BITUSA 2019 General DRESSING ROOMS

Production Advance Information

Stephen Roy s. Black & White. On-Site Requirements Stage Setup. Ideal Performance Space Set-up Other Practical Considerations Load In Show Control

Lighthouse Theatre Technical Specification

Analog General Information West End Ave. Nashville, TN, Time Zone: CST

Meeting Room Packages

Where performance matters

Barney Simon Theatre Technical Specifications

SHUT DOWN FILM INSTALLATION TECHNICAL SPECIFICATION

Technical Specifications

Main Stage Technical Specs - Hall #2

Laura Turner Hall Overview. Sound System Overview

Kenny Rogers Productions, Inc Production Requirements Indoor and Outdoor and Small Venue Performances

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

Technical specifications Main theatre. Sound

2,085 seat Colden Auditorium is $ seat LeFrak Concert Hall is $2500.

Notes for Lighting and Sound Technicians

Boise State University Invitation to Bid CF Commencement Ceremony Production Services. Location: Boise State University Taco Bell Arena

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Hospitality & Production Rider Artist: Gang of Thieves General Terms: Billing- Support- Complimentary Tickets- Security- Insurance-

Powerhouse Theatre technical information and general specifications 2017

The Taal Inc. Rhythm Ensemble Tech Rider

Technical Services and Specification

Ed Blackwell Production Manager Mike Weller Head of Music

Darlington Hippodrome Technical Specification

PRELIMINARY TECHNICAL RIDER - LITTLE RED RIVER

Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

THE CLASSIC GRAND 18 JAMAICA STREET GLASGOW G1 4QD

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Transcription:

MAJESTIC (Circus Tent) Date Thursday 2 April - Monday 6 April 2015 Site Access Bump In: Bump Out: Concert Times from 9am Tuesday 31 March from 11pm Monday 6 April Friday 3 - Sun 5 April 10am - 1am Mon 6 April 11am - 7pm Venue Requirements Contractor to supply a PA system, drapes, lighting, looms, cabling, power distribution & multicores including delivery, set up & packdown Venue size is 20m x 20m outdoor Circus style marquee Staging will be provided (7.2m x 4.8m x 0.6m) Backline is required (drum kit, amps for guitar, bass & keyboard) Sufficient power outlets will be provided Stage Management Crews & Emcees will be provided This venue is not secure and cannot be locked Seating capacity = 400 (5-7 tier gallery in the round) General Info NO VEHICLES are permitted to move onsite between 8am - 4am each day of the festival. There will be NO exeptions to this rule. Bump in must be complete by Thursday 2 April 3pm and vehicles removed from site, or parked in a pre-approved area within the festival grounds Bump out cannot commence prior to 11pm Monday 6 April You must provide the Production Manager of your arrival time & how many vehicles will be entering the site from March 1st You must also provide a list of staff names, number of wristbands required and staff roster the Production Manager by March 1st Additional WHS compliance documentation and insurances must be submitted to the Operations Manager by March 1st, refer to WHS information below All contractors and their staff must complete the online induction prior to commencement of works. All quotes to include GST Page 1 of 5

FOH Control & Processing AUDIO 48 Channel Console Analogue or Digital 16 x Compressor/Gate 2 x Reverb/Delay Unit Cd Player 31 Band Graphic Eq across FOH 31 Band Graphic Eq across all monitor sends FOH Speakers System Must be Ground stacked 3 Way Line Array PA System, Ground Stacked Subwoofer s to suit Main system Full Range In-fill as required System shall be capable of producing 98dB Full Range, Clear Undistorted Audio across all seats in the venue MON Control & Processing 4 x Monitor Sends Pre Fader - Controlled from FOH Console MON Speakers 8 x Monitor Speakers 6 x Front Line, 1 x Drum Fill, 1 x Floating Wedge Source 8 x Vocal Microphone 10 x Instrument Microphone Dynamic 10 x Instrument Microphone Condenser 8 x Assorted Microphone for drum kit 12 x Active Di Box 2 x Hand Held Radio Microphone 2 x Headset Radio Microphone 15 x Tall Boom Stand 15 x Short Boom Stand Comms Other requirements/notes Several Stereo Post Mix FOH Feed required for potential OB use Page 2 of 5

LIGHTING Control Lighting Console capable of controlling all lighting fixtures Dimmers & Distribution Dimming and Distribution to suit lighting system Rigging 8m Truss (Rear Truss, Ground Supported) 2 x Seperate 15m Truss (Room Truss's, Flown) Page 3 of 5

Fixtures 4 x 2k Fresnel 16 x Par64 8 x Moving head spot (Stage LX) 8 x Led moving head wash (Stage LX) 10 x Led Moving Head Wash (Room LX) 10 x Moving head Spot (Room LX) Atmospheres & Followspots No Haze or Smoke machine to be used Other Requirements / Notes Please note that an allocation should be made for lighting of the stage and the floor. Circus acts utilize the floor space. Lighitng is also required for set pieces which are yet to be confirmed. LED or intelliegent wash lights can be used to allow for versatility of colour and focus. Drapes 2, 6m x 4m Dlack Drape - Stage Masking (Side of Stage to Big Top Walls) 1, Star Cloth Backdrop Page 4 of 5

Bump In & Out CREW As required including Loaders & Riggers Current Rigging Licences and White Cards will be required on site Labour - SHOW FOH Operator Lighting Operator/Stage Hand Additional Requirements/Work Health & Safety (WHS) Note that the above labour requirements specify minimum crew allocation at any given time. It is the contractors responsibility to ensure staff do not work excessive hours and are given adequate breaks. A proposed crew schedule must be included with your quotation Riggers may be required to fly & set LX Truss' All contractors must comply with current ACT WHS legislation to provide safe work practices & instructions to their employees. Relevant documentation including (but not limited to): Safe Work Method Statements, Job Safety Analysis/ Risk Management Plan, Engineering Certificates for Structural works, EH&S Management System are required upon request. Relevant insurances including (but not limited to): Public Liability, Workers Compensation and Professional Indemnity (if required) must also be submitted by March 1st to Operations Manager Contractor to provide fire extinguisher in case of equipment electrical fire All electical cords must be tagged and tested as per AS/NZS 3760:2010 Inservice safety inspection and testing of electrical equipment Page 5 of 5