Fisher Dachs Associates 11/29/16

Similar documents
Invitation to Bid ITB #USL Utah Shakespeare Festival Theatrical Lighting Fixtures

Altman Lighting Spectra Cyc 50 Specification

Altman Lighting AP-150 RGBW Par Specification

Small System Packages. Strand Dimming Systems

Small System Packages. Strand Dimming Systems

PL PROFILE 1 MKII LED

L5-C LED Fresnel L I G H T I N G - P R O D U C T S P E C I F I C A T I O N V2.2

Color mixing or White-light LED (Light Emitting Diode) ERS-style product

Selecon LED Fixtures. PLPROFILE4 LED Luminaire

Church Layout Medium Advanced

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

Yoke Safety cable loop. Up Light Bulb

Selecon LED Fixtures. PLPROFILE4 MKII LED Luminaire

Selecon LED Fixtures. PL3 LED Luminaire. Features SPECIFICATION SUBMITTAL

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION.

SHOWLINE SL BEAM 100 LED LUMINAIRE SPECIFICATIONS.

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

AWT150C/AWT150CS/ AWT151C CCD Camera

Selecon LED Fixtures. PL3 LED Luminaire. Features SPECIFICATION SUBMITTAL

Catalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web:

ETC. Source Four LED Series. General information. Source Four LED Studio HD Light Engine with Shutter Barrel

SUPER LED F4.7 VW Vari-White INSTRUCTION MANUAL

ETC Quick Guide. Source Four LED Profile

2014 Product Catalog

Church Layout Small. Specifier Product Information

CITY OF TAMPA ADDENDUM NO. 4. DATE: May 19, 2015

SHOWLINE SL PAR 155 LED LUMINAIRE SPECIFICATIONS.

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

Selecon LED Fixtures. PLPROFILE4 LED Luminaire. Features SPECIFICATION SUBMITTAL. PLPROFILE4 LED Luminaire

Liner Quattro AC XB RGBW

The features shown in the following graphics may not appear on all Desire Series fixtures. LCD Power In DMX In

Model Material Lamp type LED color Voltage Distribution Lens

SHOWLINE SL NITRO 510C LED STROBE LUMINAIRE SPECIFICATIONS.

Master Electrician Handbook

SHOWLINE SL NITRO 510 LED STROBE LUMINAIRE SPECIFICATIONS.

Catalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web:

S30-C LED Soft Light LIGHTING - PRODUCT SPECIFICATION V1.0

SHOWLINE SL epar 180 LUMINAIRE SPECIFICATIONS.

General 64E4 Cultural Center is a flexible black box theater that holds 72 people including cast and crew

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

SHOWLINE SL PUNCHLITE 220 LED LUMINAIRE SPECIFICATIONS.

The following products are used in these packages:

complete, versatile and cost effective

Chroma-Q Studio One 100 D

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

thinpar 38

Lighting Information

pixelpatt Light source 7x 30W RGBW multichips Effects Individual control of each RGBW pixel, Tungsten lamp emulation

microvision FX Lighting control system Version 1.33

PRO PAR HEX 12. User Manual

SECTION 686 VIDEO DECODER DESCRIPTION

The ideal replacement solution to the VL3500 Series (profile) spot or any other 1,000W to 1,500W lamped professional moving profile light.

ELECTRICAL LEGEND NOTES AND FIXTURE SCHEDULE

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

2X2 Panel. 1X2 Panel

OWNERS MANUAL. Revision /29/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA

Source Four LED ETC. Source Four LED Series. General information. Source Four LED Light Engine with Shutter Barrel. Source Four LED Light Engine Body

HDBaseT HDMI Extender

USER MANUAL Table of Contents

S30-RP LED Soft Light

VIP-35 Manual. Video Inspection Probe

photo by courtesy of Christiaan Beukes - Sphere Custom Design, RSA FORCE SERIES XXL HOME THEATRES VIDEO-PROJECTORS FOR

ADDENDUM TO REZAC AUDITORIUM LIGHTING RFP P1617-M-5

March 4 th, Addendum No. 1. Brooklyn College Systems Integrator Broadcast Television Equipment Project No: BY019/

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

SPECIFICATIONS: Model: Supply Voltage: LED: Weight: Size: Fuse: Power Consumption: Working Position: Duty Cycle: DMX Channels:

LED Thunder S-150 Code 1097

ETC. Source Four LED Series ORDERING INFORMATION GENERAL INFORMATION. Source Four CE LED Series 2 Lustr. Light Engine with Shutter Barrel

Optical Distribution Box 300 Installation Guide. Version : R0.0

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

Source Four LED Series 2 ETC. Source Four LED Series GENERAL INFORMATION ORDERING INFORMATION

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

Michigan State University Construction Standards EXTERIOR FIBER OPTIC CABLE SYSTEM PAGE

ELECTRICAL LEGEND NOTES AND FIXTURE SCHEDULE

ZIG-POEPRO-70A. HDBaseT HDMI Extender

PROJECT DATE LENS SF FLANGE FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

Studio 180. Electronic and Print versions of the venue ground plan are available from the Technical Director.

User Manual. AtlonA. Passive VGA Extender with Wall Plate or Box options up to 330ft over 1 x CAT5/6/7 Cable AT-VGA100-SR and AT-WPVGA-SR AT-WPVGA-SR

Technical Data Sheet

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R. EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual

About The Innovator PART I: GETTING STARTED 1

IP-LINX. Installation Guide

APOLLO DESIGN TECHNOLOGY 4130 Fourier Drive Fort Wayne, IN USA Phone: Fax:

National Wire and Cable and National Cable Molding Headquarters Los Angeles California

SOFT LED 4 Vari-White INSTRUCTION MANUAL

Melrose Veteran s Memorial Middle School Auditorium 250 Lynn Fells Parkway, Melrose, MA, 02176

Industries, Inc. 402 Meco Drive Wilmington, DE Phone: (302) Fax: (302) Rental Catalog

ETC. ColorSource Series ORDERING INFORMATION GENERAL INFORMATION. ColorSource PAR

Dell Wyse 5030 PCoIP Zero Client

OPERATING MANUAL. DMX / DSI / DALI Dekoder 3004B-H Mk2

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

ETC. ColorSource Series ORDERING INFORMATION GENERAL INFORMATION. ColorSource PAR

LED IP65 Slimline Par RGBWA +UV 7x12W

Nila light fixtures are intended for indoor use only (unless clearly specified for outdoor use).

Transcription:

SECTION 265561 THEATRICAL LIGHTING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. This section specifies loose stage lighting equipment, including the following: 1. Stage Lighting Fixtures 2. Fixture Accessories 3. Lamps 4. Lighting Control Console & Accessories 5. Portable Dimming & Power Distribution 6. Cable Assemblies 7. Stage Hardware 8. Tools, Storage & Supplies B. Work not included: 1. Theatrical Lighting Controls 2. Installation of fixtures shall be by Owner 1.3 ACCEPTABLE VENDORS A. The equipment specified herein shall be supplied by only one of the following: 1. Texas Scenic 2500 Central Parkway, Ste. M Houston, TX 77092 Tel: +1 800 272 7490 3. Mainstage Theatrical Supply 15340 Vantage Parkway East, Suite 260 Houston, TX 77032 Tel: +1 281 725 1448 1.4 SUBMITTALS A. Submit a complete bill of materials for each product listed herein. 2. Stagelight 3355 West 11 th Street Houston, TX 77008 Tel: +1 713-942-0555 B. Submit product data sheets for all items for approval prior to shipment. 1.5 QUALITY ASSURANCE AND STANDARDS A. Instruments shall be fabricated according to the standards of Underwriters Laboratories, Inc. and shall be labeled to attest UL listing. B. Warrant the equipment to be free to defects in materials and workmanship for a period of one year from the date of acceptance by the Owner. The warranty shall specifically include, but not be limited to, lamp sockets, lenses, shutters, and clamps. If any item proves defective within the warranty period it shall be replaced at no cost to the Owner. PART 2 - PRODUCTS 2.1 GENERAL FABRICATION REQUIREMENTS A. Instruments shall be free of light leaks and spurious reflections adjacent to their fields. THEATRICAL LIGHTING FIXTURES 265561-1

B. Instrument fields shall be visually uniform and without hot spots, holes, stripes, or rings. Fields shall be adjustable to a cosine distribution. C. Lenses shall be water white, heat resisting, boro-silicate glass. Unless specifically excepted, ellipsoidal reflector spotlights shall have plano-convex lenses. D. Instruments shall be ventilated and/or conductively cooled to maintain temperature ratings set by lamp manufacturers. E. Exterior finishes shall be matte black high temperature enamel. F. Manufacturer s nameplates shall be inconspicuous, with letters not exceeding 1/2" (13mm) high. G. Pigtails shall be 3-0 inches (1M) long unless otherwise noted. H. Pipe clamps shall be C-Clamp type for 1.9 (48mm) O.D. pipe unless otherwise noted. Pipe clamps shall be fitted with a spacer between clamp and yoke to permit 360 rotation. I. Color frames, safety cables, top hats, donuts, barn doors, clamps and other similar accessories shall be finished in matte black high temperature paint. 2.2 STAGE LIGHTING FIXTURES A. Furnish the following stage lighting fixtures: 1. Description: 19 Ellipsoidal Reflector Spotlight Manufacturer: Electronic Theatre Controls #419 2. Description: 26 Ellipsoidal Reflector Spotlight Manufacturer: Electronic Theatre Controls #426 Quantity: 20 3. Description: 36 Ellipsoidal Reflector Spotlight Manufacturer: Electronic Theatre Controls #436 4. Description: 25-50 Ellipsoidal Reflector Spotlight Manufacturer: Electronic Theatre Controls #42550 THEATRICAL LIGHTING FIXTURES 265561-2

5. Description: 7 Fresnel Manufacturer: Electronic Theatre Controls #FRES7 Quantity: 20 6. Description: LED Cyc Light Manufacturer: Altman #SSCYC100-RGBW-B, FT Accessories: Pipe Clamps, Safety Cables (2), Floor trunion Connector: 220A Stage Pin to PowerCon Quantity: 7 7. Description: LED Zoom PAR Manufacturer: Philips #SL PAR 155 Zoom, to PowerCon Quantity: 35 2.3 FIXTURE ACCESSORIES A. Furnish the following fixture accessories 1. Description: 70 Lens Tube for Ellipsoidal Reflector Spotlight Manufacturer: ETC #470LT 2. Description: A-Size Template Holder for Ellipsoidal Reflector Spotlight Manufacturer: City Theatrical #2150 3. Description: Donut for Ellipsoidal Reflector Spotlight Manufacturer: City Theatrical #2250 4. Description: Drop-In Iris for Ellipsoidal Reflector Spotlight Manufacturer: City Theatrical #2180 5. Description: Stackable Top Hat for 19-50 Ellipsoidal Reflector Spotlight Manufacturer: City Theatrical #2840 6. Description: Stackable Half Hat for 19-50 Ellipsoidal Reflector Spotlight Manufacturer: City Theatrical #2841 7. Description: Barndoor for 7 Fresnel and Showline PAR Manufacturer: City Theatrical #2488 Quantity: 40 8. Description: Spare Color Frame for 19-50 Ellipsoidal Reflector Spotlight Manufacturer: City Theatrical #2350 Quantity: 20 THEATRICAL LIGHTING FIXTURES 265561-3

9. Description: Spare Color Frame for 7 Fresnel and Showline PAR Manufacturer: City Theatrical #2487 10. Description: Spare C-Clamp Manufacturer: ETC #400CC 11. Description: Spare Safety Cable Manufacturer: ETC #400SC 0 2.4 LAMPS A. Lamps shall be shipped to the job site in their original packing, unless used for bench focusing. B. Defective lamps shall be replaced without cost to the Owner, including shipping cost. C. Furnish the following lamps; spares have been included: 1. Description: HPL 750W/115V long life Quantity: 200 2.5 LIGHTING CONTROL CONSOLE A. The lighting control console shall be a microprocessor-based system specifically designed to provide complete control of stage, studio, and entertainment lighting systems. 1. User interface shall be fully graphical with a command line. Control commands shall be accepted as either command line or direct entry. 2. The main control shall consist of a numeric keypad, dedicated control keys, context sensitive soft keys, level control wheel, and pointing device. 3. A blind display mode shall allow viewing and modification of all recordable attributes without affecting live stage levels. 4. A patch display mode shall be used to display and modify system control channels with their associated data. 5. Control and programming features for automated fixtures shall include: a standard library of fixture profiles, the ability to copy and edit existing profiles and create new profiles, patch displays including channel and output addressing, 16-bit fade resolution, color characterization allowing color mixing and storing in hue and saturation or native device values. 6. Control channel data shall be recordable as cues, groups, submasters, palettes, effects, macros, curves, and patch contained in non-volatile electronic memory and stored as show data to internal storage or to any USB storage device. 7. The console shall be capable of being placed in Tracking or Cue Only record mode by the user. 8. A freely available offline editing application shall be provided for creation and modification of show data on a personal computer. 9. A personal computer running a client software application shall be able to connect to a control system via the network and view current show data in a mirrored display environment. 10. The system shall allow remote control from a wireless handheld remote. 11. The system shall support configuration and operation of two consoles or a console and a dedicated processor as a main and fully tracking backup. 12. Lighting Network device control: a. Direct control of third party sacn/acn devices THEATRICAL LIGHTING FIXTURES 265561-4

b. DMX512 / RDM hardware interfaces c. Support MIDI, SMPTE and RS-232 interfaces B. Provide the following control console: 1. Electronic Theatre Controls Ion 1000 w/ 2x20 Fader Wing C. Provide two (2) external 22 or larger touchscreen LCD monitors, external keyboard, mouse, 6-0 (2m) power and data cables, dust covers, and littlelight task lights. D. Provide a Wireless Hand-Held Remote capable of setting individual channels and groups of channels to levels, raising and lowering the levels, stepping automatically to the next or last cue or channel, going to and playing back individual cues. E. All peripheral accessories such as remote monitors and hand-held remote units shall interconnect as a network. The facility shall be wired by the Electrical Contractor for this function with an Ethernet cabling system as specified herein. F. Furnish the following console accessories: 1. One (1) Portable uninterruptible power supply, APC Smart-UPS 750VA. 2. Four (4) IEC C13 to C14 power cords, 10-0 (3m) length. 3. Two (2) 8 GB capacity USB storage keys, ETC #I6209 or approved equal. 2.6 PORTABLE DIMMING & POWER DISTRIBUTION A. Furnish the following items: 1. Description: Source Four Dimmer Manufacturer: ETC # S4DIM, S4DIM-Jr, S4DIM-Par Accessories: Yoke Mount Bracket Connectors: 20A Stage Pin 10 2.7 CABLE ASSEMBLIES A. All cable assemblies shall be tested after fabrication to assure wire continuity and correct polarity of connections. B. All cable assemblies shall include shrink wrapped identification label with text Moody Center beneath shrink wrap. C. DMX512 (5-pin XLR) cable assemblies shall consist of ruggedized cable, terminating at each end to Neutrik XX-Series XLR5 connectors with black shell and color coded bushing to identify cable length. Assemblies shall be terminated in accordance with USITT (United States Institute for Theatre Technology) DMX512 specification. Furnish the following: 1. (80) DMX512 cable assemblies of 5-0 (1.5M) length, red color code. 2. (60) DMX512 cable assemblies of 10-0 (3M) length, green color code. 3. (40) DMX512 cable assemblies of 25-0 (8M) length, purple color code. 4. (2) DMX512 cable assemblies of 50-0 (15M) length, orange color code. D. Ethernet cable assemblies shall consist of ruggedized Category 6a cable, terminating at each end to Neutrik Ethercon CAT6a RJ-45 connectors with black shell and color coded bushing to identify cable length. Assemblies shall be terminated in accordance with TIA/EIA-568-B standards. Furnish the following: 1. (5) Ethernet cable assemblies of 5-0 (1.5M) length, red color code. 2. (5) Ethernet cable assemblies of 10-0 (3M) length, green color code. 3. (2) Ethernet cable assemblies of 25-0 (8M) length, purple color code. THEATRICAL LIGHTING FIXTURES 265561-5

E. Stage Pin Extension assemblies shall consist of 12/3 SOOW cables, terminating at each end with a 20A 2-pin & ground stage pin connector. Label cables at each end with shrink wrapped color- code to identify cable length. Furnish the following: 1. (40) Stage Pin Extension assemblies of 5-0 (1.5M) length, red color code. 2. (50) Stage Pin Extension assemblies of 10-0 (3M) length, green color code. 3. (40) Stage Pin Extension assemblies of 25-0 (8M) length, purple color code. 4. (5) Stage Pin Extension assemblies of 50-0 (15M) length, orange color code. F. Edison Extension assemblies shall consist of 12/3 SOOW cables, terminating at each end with a NEMA 5-15 connector. Label cables at each end with shrink wrapped colorcode to identify cable length. Furnish the following: 1. (3) Edison Extension assemblies of 25-0 (8M) length, purple color code. 2. (2) Edison Extension assemblies of 50-0 (15M) length, orange color code. G. PowerCon pass thru jumper assemblies shall consist of 12/3 SOOW cables, terminating at each end with a Neutrik PowerCon connector. Label cables at each end with shrink wrapped color- code to identify cable length. Furnish the following: 1. (40) PowerCon jumper assemblies of 5-0 (1.5M) length, red color code 2. (40) PowerCon jumper assemblies of 10-0 (3M) length, green color code. H. Stage Pin Two-Fer and Three-Fer assemblies shall consist of high temperature wire in molded sleeves, a 20A male stage pin plug, and dual or triple 20A female stage pin receptacles. Furnish the following: 1. (40) Stage Pin Two-Fer assemblies of 36 (1M) length. I. Adapter assemblies shall consist of 12/3 SJOW cables, terminating at one end with connectors as indicated below. Furnish the following: 1. (5) Female Edison to male stage pin Adapter assemblies of 36 (1M) length. 2. (5) Male Edison to female stage pin Adapter assemblies of 36 (1M) length. 3. (5) Male Edison to PowerCon Adapter assemblies of 5-0 (1.5M) length. 2.8 STAGE HARDWARE A. Furnish the following components: 1. Description: City Theatrical Track Tamer with Hex Nut, #520 2. Description: City Theatrical Track Tamer with Galvanized Clamp, #525 2.9 TOOLS, STORAGE, & SUPPLIES A. Furnish the following items: 1. Description: Heavy Duty 30 x 30 Cable Trunk w/ 4 Casters 2. Description: Fluke #179/1AC-II Multimeter Kit 3. Description: GamChek Stage Pin Circuit Tester THEATRICAL LIGHTING FIXTURES 265561-6

4. Description: Psiber LanMaster LM35 Power & Link Tester 5. Description: TMB ProTester DMX Tester 6. Description: 5-Pin DMX Terminator 7. Description: Stage Pin Connector Pin Splitter 8. Description: Spare 2 Pin & Ground Stage Pin Connectors (Male) 9. Description: Spare 2 Pin & Ground Stage Pin Connectors (Female) 10. Description: 2 x180 Black Gaffers Tape Quantity: 2 11. Description: 2 x75 Blacktak Masking Foil 12. Description: 3000 Spool 1/8 Black Cotton Unglazed Tie-Line 13. Description: Rip-Tie Cable Wrap, 1 x6 (10 pack) 14. Description: Rip-Tie Cable Wrap, 1 x14 (10 pack) PART 3 - EXECUTION 3.1 SHOP PREPARATION A. Stencil "MOODY" in one inch high characters on each stage lighting fixture body, lens barrel, top hat, barndoor, storage case, power distribution box, and other similar items and components using rust red paint. B. Install connectors and lamps for all fixtures prior to delivery. C. Bench focus all ellipsoidal reflector spotlights. D. Test all fixtures prior to packing for delivery. 3.2 DELIVERY A. Bidder is responsible for coordinating delivery times per the Owner s schedule; delivery FOB to Houston, TX. 3.3 PROTECTION OF EQUIPMENT A. Protect the equipment in this Section from damage and deterioration during all phases of the work, from the time of manufacture to the acceptance of the completed installation. END OF SECTION 265561 THEATRICAL LIGHTING FIXTURES 265561-7