2017 TECHNICAL SPECIFICATIONS

Matt Dann Cultural Centre

CENTRE FOR PERFORMING ARTS

Latrobe Performing Arts Centre

Technical Specifications

Yan Yean Theatre Technical Specifications

Esso BHP Billiton Wellington Entertainment Centre

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

John Leslie Theatre. Technical Specifications. Updated July 2018

Technical Specification

DEREHAM MEMORIAL HALL

Main Stage Technical Specs - Hall #2

RPAC REDLANDS PERFORMING ARTS CENTRE

Dr JOHN GALLAGHER CONCERT CHAMBER

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Technical Information

Access to back stage is off Fletcher St on the eastern side of the building

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Arcadia Performing Arts Center Technical Specifications and Information

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

Theatre Technical Specifications

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Monash Academy of Performing Arts

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

INFORMATION FOR VISITING COMPANIES

Monash University Academy of Performing Arts

Don Russell Performing Arts Centre

Mildura Arts Centre. Mildura Arts Centre Theatre. Technical Specifications. Updated 23/6/06

Technical Specification for the Alley Theatre, Strabane

THE STREET THEATRE. Technical Specifications

Technical specifications Main theatre. Sound

Technical Specifications

New Theatre Royal Lincoln Technical Information

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Main House Technical Specification

BANYULE THEATRE TECHNICAL INFORMATION. 10 Buckingham Drive Heidelberg VIC Page 0 of 10

Sandusky State Theatre Technical Specifications

Orange Civic Theatre

HIRE AND TECHNICAL INFORMATION

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Access door to stage from scene dock - 2.9m by 2.9m.

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Technical Specifications

UNIVERSITY CONCERT HALL. Technical Specification

Technical Specification Pavilion Dance

Theatre Technical Specifications

Dinkelspiel Auditorium - Technical Specifications

THEATRE Technical Specifications

ISLAND HALL TECHNICAL INFORMATION

TECHNICAL SPECIFICATIONS

Technical Data Sheet

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Technical Services and Specification

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Powerhouse Theatre technical information and general specifications 2017

JERWOOD VANBRUGH THEATRE

Technical Specification. Updated: April 2016

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

D A R E B I N A R T S & E N T E R T A I N M E N T C E N T R E

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Visy Theatre technical information and general specifications 2019

Summary. Access and Parking

Rhodes Arts Complex Bishops Stortford. Technical Specifications

Technical Specification

Technical Specifications

Technical Specifications and Inventory Spring 2018

Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel

Technical Pack. Attenborough Arts Centre

VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

Concert Hall Technical Specifications

Project manager (PM): Pamela Næss Mail: Phone:

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

TECHNICAL SPECIFICATIONS RIVERSIDE THEATRE

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

A red velvet front of house curtain closes off the main stage leaving only the apron visible to the audience.

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

Gosford City Council

MONASH University Academy of Performing Arts

Technical Information

Concert Hall Technical Specifications

Patriots Theater at the War Memorial Technical Data

Technical Specifications Nov 2016

Theatre Technical Specifications

Marjorie S. Deane Little Theater

THEATRE EQUIPMENT DECEMBER 2017

TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE

Hopgood Theatre NOARLUNGA CENTRE

Parking for cars, busses and tractor/trailers available on the east side of building. Handicapped parking available on the north side of building

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

Queensland Performing Arts Centre

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

The Haymarket Basingstoke Technical Specifications

Transcription:

2016 www.goldfieldsartscentre.com.au 1

Venue Technical Specifications General information Address 35 Cheetham Street Kalgoorlie WA 6430 Postal Address Goldfields Arts Centre C/- PO Box 2042 Boulder WA 6432 Contacts Venue Box Office +61 8 9021 0999 Venue Manager, Goldfields Arts Centre +61 8 9021 0998 Donna Malec gacmanager@ckb.wa.gov.au Venue Production Coordinator +61 8 9021 0993 David Ellers gactech@ckb.wa.gov.au www.goldfieldsartscentre.com.au 2

Vehicle Access Stage Access & Car Parking Vehicle entry is via Hanbury Street. Seven car spaces are available near the loading dock and allocated at the discretion of the Presenter. Back Stage Door is located between the Hanbury Street car park and loading dock door. Loading Dock Truck access is via Hanbury Street. There is sufficient space to park one semi-trailer up to the stage loading door. Only end loading is available and ramps to the trailer are required. Dock is at stage /ground level. The Loading Bay is situated on the PS (SL) side of stage with the following dimensions. Maximum Door Height 5.700m Maximum Door Width 2.400m Auditorium and Seating information The seating area comprises 20 rows. With a total of 700 seats available. First 3 rows are removable (51 seats). If seats are to be removed costs will apply. A seating plan is available via the website or on request. Access into the auditorium is via 4 doors. Access to the stage from the auditorium is done on either side through pass doors. Stairs cannot be placed in front of stage for direct stage access. www.goldfieldsartscentre.com.au 3

Stage Details Brief Stage Description The stage is non raked with proscenium and flying facilities. Timber floor board covered with Masonite sheets. Screwing into the floor may be permitted with authorisation from the Technical Manager. Stage Dimensions Proscenium 12m (W) x6m (H) Main stage area without drapes 18.4m (W) x10m (D) Main stage area with legs in & rear tabs 8.8m (W) x 9.6m (D) Wing Prompt 2.40m Wing Opposite Prompt 4m Maximum floor loading - Surface painted plywood (low sheen black) Distance From FOH light & sound control to front of stage 20.00m Bio Box to front of stage 24.00m Setting Line to Down Stage edge 1.145m Setting Line to Fire Curtain 0.35m Setting Line to House Curtain (Line 1) 0.65m Setting Line to the back wall 11.00m Setting Line to LX1 (Line 3) 1.03m Setting Line to LX2 (Line 12) 2.84m Setting Line to LX3 (Line 21) 4.87m Setting Line to LX4 (Line 32) 7.28m Setting Line to the last line (line 42) 9.28m Distance from Stage Front C to Bridge 1 C 10.70m Distance from Stage Front C to Bridge 2 C 19.10m When the Fire curtain is fully retracted it is still 0.75m with in either side of the Proscenium Arch. The house P.A. is Located on the front corners of the stage in front of the Fire Curtain www.goldfieldsartscentre.com.au 4

EWP The Arts Centre has one 6m single man EWP available. Maximum load is 132Kg this is for operator and tools required. This is a non-motorised unit and requires the use of outriggers. Ladders (1) 1.5m A frame ladder (1) 2m A frame ladder (1) 4m A frame ladder Basement Area 80sq/m (12m x 7m on arc) Access Hoist 2.3m (wide) x 1.7m (deep) Through to Pit 1.8m (wide) double doors Stairs (P/S) 1.0m (wide) single door Please Note - Hoist travels from Stage height down to the Basement. Flying Facilities Fly System The fly system is a single purchase Hemp fibre handline system. Fly system Details Operating position OP at stage level Total number of Lines 39 lines Batten Type 52mm O/D pipe Batten spacing 200mm centres (approx.) Batten W.L.L. 450Kg even distribution Travel from Proscenium 7.4m Cradle Capacity 396kg www.goldfieldsartscentre.com.au 5

Standard Hanging Plot SL : Setting Line Line # Distance From SL W.L.L Standard Venue Allocation Intended Use (hiring company use) HC 35cm Fire Curtain Retractable, Fixed 1 65cm House Curtain 2 85cm 3 105cm LX1 Fixed 4 125cm 5 145cm 6 165cm 7 185cm 4X4 Rear Pro Screen Please Confirm Current Location 8 205cm Border 9 225cm Legs 10 245cm 11 265cm 12 285cm LX2 Fixed 43cm space 13 330cm 14 350cm 15 370cm 16 390cm 17 409cm Border 18 429cm Projector Please Confirm Current Location 19 450cm Legs 20 469cm 21 489cm LX3 Fixed 22 510cm 23 530cm 24 550cm Half Stage Border 25 570cm Burgundy Curtain Fixed 26 590cm 27 609cm 28 630cm 29 649cm 30 669cm Border 31 688cm Legs 43cm space 32 731cm LX4 Fixed 33 751cm 34 Decommissioned 35 791cm 36 811cm 37 Decommissioned 38 Decommissioned 39 871cm Tabs 40 901cm 41 911cm Cyclorama Fixed 42 931cm Old Cyclorama Fixed www.goldfieldsartscentre.com.au 6

Drapes & Curtains Drape Quantity Width (m) Height (m) Colour Material Comments Fire Curtain 1 14 8 Blue Fire Retardant Line HC Non-Flyable Linear travel on motor House Curtain 1 14 8 Black Wool Line 1 Flyable Tabs 1 14 8 Black Wool Line 39 In Front of Cyc Legs 3 4 8 Black Wool Line 9, 19, 31 Borders 4 14 3 Black Wool Line 8, 18, 25, 30 Cyclorama 1 14 8 White Line 41 Curtain 1 14 8 Burgundy Line 25 Not moveable Lighting Facilities Control System Dimmers ETC Ion 20 Fader, 1024 channels, touch screen Strand Palette Classic 250 channels DMX NOTE: The GAC Theatre has only 1 physical universe currently running from the Lighting Position to the Dimmer gallery located DS PS above the SM Area. There is no 5pin DMX cable in the Venue Quantity Type Protocol Capacity 10 Jands HPC-AZ100 DMX 2.4kw 2 Jands DD-8 Distribution DMX N/A Dimmers are located above Stage Managers position DMX outlets are all 5pin XLR DMX Distribution is on all LX bars and selected areas on stage & on the bridges. Contact the Technical Manager for more information. www.goldfieldsartscentre.com.au 7

Stage Lanterns Type Quantity Beam Angle Power Selecon Fresnel 1200 22 1.2kw Par 64 12 MED/VN 1kw/240v Selecon Mini-Fresnel 8 650w Selecon Mini-PC 6 Strand SL 20 15-32 600w Strand SL 8 23-50 600w Selecon ZS1200N 6 8-16 1.2kw Selecon ZS1200M 10 16-32 1.2kw Selecon ZS650 12 16-30 650w Selecon ZS650 7 24-40 650w Strand SL 8 10 600w Colortran Top Cyc Units 4 1250W Selecon Performer MSR (Follow Spot) 2 1.2kw NOTE: Selecon 650w Fresnels 7 Barn doors Selecon 1200 Fresnels 22 Barn doors Barn Doors for the 650w units are suited to both the Mini PC s and Mini Fresnels. www.goldfieldsartscentre.com.au 8

Special FX Quantity Type 1 1500w Geni Giga Strobe 1 18 Motorized Mirror Ball 1 Jem zr44 Hi Mass Fogger NOTE: Prior Notice must be given when using Atmospherics Dimmable Outlets Front of House FOH1 Continuous slot - 6m from proscenium (approx) 27 outlets (201-227) FOH2 Three slots - 17m from proscenium (approx) P, C, OP 19 outlets (245-264) Apron Perch OP (228-231) & P (240-243) On Stage Lighting bars are fixed and cannot be swung LX Bar 1 40 outlets [~line 3] (1-40) LX Bar 2 40 outlets [~line 12] (41-80) LX Bar 3 30 outlets [~line 21] (81-110) LX Bar 4 30 outlets [~line 32] (111-140) (6) Stage boxes with 2-3 in each on P and OP in the wings (4) outlets far Prompt wall (4) outlets far OP walls downstage www.goldfieldsartscentre.com.au 9

Audio Facilities FOH Console & Processors Quantity Make & Model Comments 1 Midas Pro 2 Digital Mixing System, Midas DL251 48/16 I/O Midas DL153 16/8 I/O Klark Technik Network Bridge AES50 DANTE 64 ch converter 64 simultaneous input processing channels 8 VCA 16 mix buses 8 matrix buses Left, Right & Mono buses 1 Soundcraft GB8 32ch analog desk Only 4 graphics for Foldback sends when this is used 3 Klark Teknik DN 370 dual EQ 1 DBX PA+ Driverack System Controller 1 Yamaha SPX100 Multi-FX Processor 1 24 channel analogue multicore to mix position and Bio Box 24 channels includes the returns to stage Gender changes needed for returns to stage Sources Quantity Make & Model Comments 1 Tascam MD CD1 Player 1 Yamaha Multi-disk CD Player Front of House P.A. Quantity Make & Model Powered 2 L Acoustics 115XT HiQ L Acoustics LA8 Bi-amp d 2 L Acoustics SB18i Subs L Acoustics LA8 Passive 2 L Acoustics 12XTi L Acoustics LA8 Stereo In-Fill NOTE: Both the FOH and In-Fill speakers are located far down stage prompt and opposite prompt. Please keep this mind as microphone placement may need to be considered. www.goldfieldsartscentre.com.au 10

Fold-Back System NOTE: 6 Individual amplified sends are available & located @ stage managers box Quantity Make & Model Powered 6 Turbosound wedges 600w Lab Gruppen IP 2100 in Stage Managers Box Microphones/DI Boxes Quantity Make & Model 2 Shure SM81 (instrument) 1 Shure SM58 Beta (vocal) 8 Shure SM58 (vocal) 7 Shure SM57 (Instrument) 1 Peavey PVM 520 (Bass) 4 Audio Technica Condenser s (with clips) 1 Shure Drum Kit Mic Set (x3 SM57 with clamps/x1 Beta 52A) 4 Crown PZM Plate Mic 2 Radial J48 active D.I. Wireless Microphones Quantity Make & Model 8 Sennheiser EW 300 G3 receiver 4 Handheld 935 transmitter 8 Beltpack transmitter 4 Sennheiser ME 4 Lavalier Cardidoid 4 Slimline skin tone single ear headset General Audio Quantity Type 1 24/4 Multicore 40m 13 Microphone Boom stands 2 Lectern Goosenecks 1 Lectern Light/power supply General Accessories Quantity Type 2 Steel Rostra (Black Carpet top + Skirt) 600mm(H)x2400mmx1200mm 2 Steel Rostra (Black Carpet top + Skirt) 300mm(H)x2400mmx1200mm 1 Baby Grand Piano (Movable) 1 Gold Lectern (600mmx1145mm) Chairs & Tables www.goldfieldsartscentre.com.au 11

NOTE: In regards to the Baby Grand Piano, THERE IS NO QUALIFIED PIANO TUNER IN TOWN A/V Equipment Bio Box Centrally located directly behind mix position Comms, 32A 3phase, Cat6 patch point, (2) Performer follow spots, curtain and house lights control. Rear Projection Screen Framed & Flyable (4m x 4m) Free Standing (3m x 3m) Data Projector Satellite Receiver Sony VPL-CX150 (Able to mount on Fly Bar) VGA and composite input only, standard def Native Res. 1024x768, 4:3, 3500 Ansi-Lumens. Projector to screen is 7.5m throw Vast receiver in Bio Box (set up for receiving simulcasts via the Westlink network). Audio is linked to the sound system using DBX db10 DI s NOTE: We do not have any video switching devices, This must be organized/paid for by the hirer GAC CAT5e, CAT6 Shielded & Single Mode Fibre Network The GAC has recently been upgraded with CAT5e, CAT6 and Single Mode Optical Fibre (SMOF). There are multiple termination points throughout the venue to connect via Pointto-Point. in the venue. Theatre Three Phase Power Quantity Location Amps/Outlet3Ø Connect 2 Stage Back wall 32A 3phase Connector 1 Bio-Box 32A 3phase Connector NOTE: All mains electrical connections & disconnections are only carried out by Arts Centre personal www.goldfieldsartscentre.com.au 12

Test and Tag All electrical appliances shall be tagged with an appropriate safety tag in accordance with AS 3760:2010 Stage Management Facilities Stage Managers Console The Recessed Stage Managers area is located on the Prompt side. The Stage Management Console contains all standard facilities including: Talkback Base Station (1) Jands EziComm Belt Packs (5) Headset Wireless Talk Back Positions (5) Beyer Dynamic N/A Stage managers Box, Fly System (on cable runner), Bio Box, Mix Position, Bridges 1 & 2, Gantry Back stage Back Stage Accommodation Dressing Rooms Quantity Type Details 2 Large Room 11 individual positions with lighted mirrors and 2 costume racks, 2 showers, 2 vanity basins and 2 toilets 2 Single Room 1 position with lighted mirror and costume rack, shower, toilet and vanity basin 1 Green Room Tea/Coffee, fridge & basin and comfortable seating NOTE: Access to Dressing Rooms is located upstage prompt and off prompt side. Dressing Rooms have access to A/V feeds from the stage including. Function Room access is located near loading dock. www.goldfieldsartscentre.com.au 13

Smoking There Are No Laundry Facilities at This Venue WIFI/Internet Access Available at This Venue please request passwords on arrival Smoking within the building and within 10m of doorways and air con intake ducts is strictly prohibited Food & Beverage In relation to catering the Arts Centre has standard layouts available upon request. Contact the Venue Manager for details. www.goldfieldsartscentre.com.au 14