CONSUMER UPS SINGLE PHASE UPS UP TO 3000 VA THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

Similar documents
MASTER DIALOG ERM 8-20kVA three/single phase ERT kVA three/three phase

FN Series Scalable N+1 UPS 3kVA to 40kVA Tower

Chloride EDP Series Three-Phase UPS ( kva): The EDP Series UPS is designed

LED Driver Linear / area fixed output

LED Driver Compact fixed output

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

LED Driver Compact fixed output

Programmable Power Supplies 188 W 384 W R&S HMP Series

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

Rack mounted telephone- and leased line modem for industrial applications

1/3 RACK-MOUNTED BLOCK CONVERTERS

Fluke 279 FC True-rms Thermal Multimeter

LED control gear Compact fixed output

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Model KT 53 Cooling incubators with thermoelectric cooling

IP Roombox. Hotel Room Management

Indoor Linear 80W Driver SI-C215280N2KR

Innovation in Magnetic Field Measuring Instruments. Magnetometer Power Supplies

R-1580A Microwave Downconverter. Product Brochure

Clamp 200 A AC/DC (+ V AC/DC + Ω)

LED Driver Compact fixed output

10 PDUs 19 PDUs Zero-U PDUs

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

EMC Solutions Noise filtering

DA E: Series of Narrowband or Wideband Distribution Amplifiers

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

1 Power Protection and Conditioning

Catalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web:

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

Model KT 115 Cooling incubators with thermoelectric cooling

WyreStorm NetworkHD HD Over IP with HDMI Pass-through, RS232

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Innovation in Magnetic Field Measuring Instruments. Magnetometer Power Supplies

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Model KBF 1020 Constant climate chambers with large temperature / humidity range

We bring quality to light. SNT 10 DC Power Supply

Process Transmitter RMA 422

BS36 Waveform TDR (Time Domain Reflectometry) Cable Fault Locator

Re-defining the utility-scale inverter

Converters Series Tri-Band Frequency Converters. Back to Multiband. Specifications Upconverters Downconverters Phase Noise Options Rear Panel

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

A Perfect Solution for Digital Signage in Commercial Areas CDE4600-L

Product Brochure. June M5 Series. Metal Detector

INSTALLATION & USER GUIDE

P Output Ratings. Dimensions and Weights. Prime Rating

Certificate of Calibration

P Output Ratings. Dimensions and Weights. Prime Rating

P88-3. Output Ratings. Dimensions and Weights. Prime Rating

MULTIBAND 1/3 RACK-MOUNTED

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

Synthesized Block Up- and Downconverter Indoor / Outdoor

HDMI over CAT5 HDBaseT Extender - Power over Cable - IR - RS232-10/100 Ethernet - Ultra HD 4K ft (100m)

P65-5. Output Ratings. Dimensions and Weights. Prime Rating

Operating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface

LED Driver Compact dimming

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

MAP110 AC-DC Series Data Sheet

Catalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web:

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

P Output Ratings. Dimensions and Weights. Prime Rating

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Ratings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage.

P1000P1/P1100E1 50Hz

P Output Ratings. Dimensions and Weights. Prime Rating

P800P1/P900E1. Output Ratings. Dimensions and Weights. Prime Rating

Satellite Up- and Downconverter Indoor / Outdoor

P Output Ratings. Dimensions and Weights. Prime Rating

Model KBF 115 Constant climate chambers with large temperature / humidity range

OPTICAL POWER METER WITH SMART DETECTOR HEAD

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

P1350P1/P1500E1 50Hz

S0 Radio Broadcasting Mixer. June catalogue. Manufacturers of audio & video products for radio & TV broadcasters

Per computer/workstation: Computer Connectors per device: 2 With optional cable sets on the device Interfaces

L-Band Block Up- and Downconverter Indoor / Outdoor

R&S ZN-Z154 Calibration Unit Specifications

Marshall Electronics. Pro A/V Communications VMV-402-SH. 3G/HD/SD-SDI Quad-viewer/Switcher with Audio Meter Display. User Manual.

ABB i-bus EIB Universal dimmer 6155 EB for Installation

Kingstar MIG/MAG. Kingstar 400 TS Kingstar 520 TS KINGSTAR MIG

VIDEO ALARM VERIFICATION UNIT VIVER

VIDEO MATRIX SWITCHES HDMI 2.0

DANGER. DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING

RadioRA 2 Enhancement and Interface, 120V main repeater with MHz to MHz or MHz to MHz

LandRake HYC V 4006-MIMO Series 4GHz PTP / NATO Mobile Mesh Series

REGO Start&Go USER MANUAL

R&S ZN-Z85 Switch Matrix Specifications

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

Wall Plate HDMI over CAT5 Extender with Power Over Cable 1080p 165ft (50m)

Model KBF 720 Constant climate chambers with large temperature / humidity range

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Sphinx II. Owner s Manual. Tube Hybrid Integrated Power Amplifier. Rogue Audio, Inc. 3 Marian Lane Brodheadsville, PA Issue date: 08/01/16

DIN Power Module - Phase Adaptive

L-Band Block Upconverter

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

HDMI Over IP Extender Kit - 4K

TOSHIBA Industrial Magnetron E3328

Transcription:

CONSUMER SINGLE PHASE UP TO 3000 VA THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

KEOR Multiplug Multi outlets from 600 and 800 VA for (digital) homes, shops, hotels. This is the perfect solution to ensure a safe and high quality energy supply to modem, router, Smart TV, home entertainment systems, POS, cash machine. It s equipped by a USB charger to recharge smartphone or tablet. 2

Keor Multiplug Single phase VI Keor Multiplug Single phase VI n Characteristics 3 100 83 Automatic start-up: when there is no mains supply or it is of poor quality, the continues working using a battery and switches off if the network breaking time exceeds the back-up time. Technical characteristics - Replaceable fuse for fine protection in case of short-circuits - LED indicators - Internal AVR (Automatic Voltage Regulator) - USB Charger - Available outputs in German or French type Pack Cat. No. Multi-socket French standard German standard 4 backup with protection from voltage surges 2 with protection from voltage surges (VA) (W) Back-up time (1) 1 3 100 83 3 100 81 600 360 up to 15 4+2 1 3 100 84 3 100 82 800 480 up to 15 4+2 NOTE: The stated back-up times in minutes are estimated and may vary according to the load characteristics, operating conditions and environment. General characteristics 3 100 83 3 100 81 3 100 84 3 100 82 (VA) 600 800 (W) 360 480 Technology Line Interactive VI Waveform Simulated SineWave Input characteristics Input voltage 230 V Input frequency 50-60 Hz +/- 5Hz Input voltage range 170 V-290 V Output characteristics Output voltage 230 V ± 10% Output frequency (nominal) 50/60 Hz +/-1 Hz USB charger/voltage Type A female/5 V Mechanical characteristics Dimensions W x H x D (mm) 190 x 89.5 x 296 Net weight (kg) 5 5,5 Ambient conditions Ambient operating temperature ( C) 0 to 40 C Relative humidity (%) < 95% non-condensing Noise at 1 m (dba) < 40 Certifications Reference product standards EN 62040-1, EN 62040-2 WWW..LEGRAND.COM CONSUMER 3

KEOR SP for offices and IT applications from 600 up to 2000 VA The innovative LED bar makes easy to understand if everything is ok. The Legrand design will allow you to install Keor SP everywhere. The integrated AVR will guarantee a stable energy supply to your IT equipment to get the best performance from it. Complete protection: discharge, overload, short-circuit, thermal protection. 4

Keor SP Single phase VI Keor SP Single phase VI n Characteristics 3 101 83 3 101 92 Technical characteristics - 3 colors LED bar - Mute button - Internal AVR (Automatic Voltage Regulator) - USB Port - Available outputs in IEC, German or French type Pack Cat. Nos. international socket VA W Back-up time IEC Communication ports 1 3 101 80 600 360 up to 15 4 USB HID 1 3 101 83 800 480 up to 15 4 USB HID 1 3 101 86 1000 600 up to 10 6 USB HID 1 3 101 89 1500 900 up to 10 6 USB HID 1 3 101 92 2000 1200 up to 10 6 USB HID with IEC+ German socket VA W Back-up time IEC+GER Communication ports 1 3 101 81 600 360 up to 15 1+1 USB HID 1 3 101 84 800 480 up to 15 1+1 USB HID 1 3 101 87 1000 600 up to 10 2+2 USB HID 1 3 101 90 1500 900 up to 10 2+2 USB HID 1 3 101 93 2000 1200 up to 10 2+2 USB HID with IEC+ French socket VA W Back-up time IEC+FR Communication ports 1 3 101 82 600 360 up to 15 1+1 USB HID 1 3 101 85 800 480 up to 15 1+1 USB HID 1 3 101 88 1000 600 up to 10 2+2 USB HID 1 3 101 91 1500 900 up to 10 2+2 USB HID 1 3 101 94 2000 1200 up to 10 2+2 USB HID 3 101 80 3 101 83 3 101 86 3 101 89 3 101 92 General characteristics 3 101 81 3 101 84 3 101 87 3 101 90 3 101 93 3 101 82 3 101 85 3 101 88 3 101 91 3 101 94 (VA) 600 800 1000 1500 2000 (W) 360 480 600 900 1200 Technology Line Interactive VI Waveform Simulated SineWave Input characteristics Input voltage 230 V ± 10% Input frequency 50-60 Hz +/- 5Hz Input voltage range 170 V-290 V Output characteristics Output voltage 230 V ± 10% Output frequency (nominal) 50/60 Hz +/-1Hz USB charger/voltage - Type A female / 5 V Communication and management Screen and signalling Remote control Two buttons and LED bar for real-time control of the status of the Available Mechanical characteristics Dimensions W x H x D (mm) 120 x 138 x 330 148 x 173 x 380 Net weight (kg) 5 5,5 9 10,5 11,8 Ambient conditions Ambient operating temperature ( C) 0 to 40 C Relative humidity (%) < 95% non-condensing Noise at 1 m (dba) < 40 Certifications Reference product standards EN 62040-1, EN 62040-2 IEC Socket French socket NOTE: The stated back-up times in minutes are estimated and may vary according to the load characteristics, operating conditions and environment. German Socket NOTE: The pictures refer to Keor SP 800 model WWW..LEGRAND.COM CONSUMER 5

NIKY S Single-phase VI-SS from 1 up to 3 kva 6

IN OUT USB RS232 IN OUT USB RS232 NIKY S Single phase VI-SS NIKY S Single phase VI-SS n Characteristics 3 100 06 Technical characteristics - Sinusoidal output - Microprocessor control - MODEM/LAN telephone protection - RS232 or USB interface - Cold start function - Protection against voltage peaks - Integrated self-diagnostics - Intelligent battery management - Overload and short-circuit protection - Excellent voltage regulation Pack Cat. Nos. with IEC socket VA W Back-up time IEC Communication ports 1 3 100 06 1000 600 5 6 USB-RS232 1 3 100 20 1500 900 5 6 USB-RS232 1 3 100 07 2000 1200 5 6 USB-RS232 1 3 100 08 3000 1800 5 6 USB-RS232 NOTE: The stated back-up times in minutes are estimated and may vary according to the load characteristics, operating conditions and environment. General characteristics 3 100 06 3 100 20 3 100 07 3 100 08 (VA) 1000 1500 2000 3000 (W) 600 900 1200 1800 Technology Line interactive VI-SS Waveform Sinusoidal Input characteristics Input voltage 230 V ± 10% Input frequency 50-60 Hz +/- 3Hz Input voltage range 160 V-290 V Output characteristics Output voltage 230 V ± 10% Output frequency (nominal) 50/60 Hz +/-0.2% THD of output voltage < 3% with linear load Communication and management Screen and signalling LCD Display with three buttons and three LEDs for real-time control of the status of the Telephone protection RJ 11/RJ 45 Remote control Available Mechanical characteristics Dimensions H x W x D (mm) 247x173x369 247x173x465 Net weight (kg) 13 15 22 24 Ambient conditions Ambient operating temperature ( C) 0 to 40 C Relative humidity (%) 0 to 95% non-condensing Noise at 1 m (dba) < 40 Certifications Reference product standards EN 62040-1, EN 62040-2, EN 62040-3 1000-1500-2000 VA 3000 VA WWW..LEGRAND.COM CONSUMER 7

World Headquarters and International Department 87045 Limoges Cedex - France : + 33 (0) 5 55 06 87 87 Fax : + 33 (0) 5 55 06 74 55 AD-EXLG/-CO18B/GB - 01/2018 In accordance with its policy of continuous improvement, the Company reserves the right to change specifications and designs without notice. All illustrations, descriptions, dimensions and weights in this catalogue are given as a guide only.