Multi Channel Programmable Filter-Amplifier. User Manual I-II III V-U SAT. Stop Channel SAT Slope Start Channel SAT ON / OFF.

Similar documents
UK. Multi Channel Programmable Filter-Equalizer. User Manual FEATURES. - Designed for both digital and analogue channels,

Multi Channel Programmable Filter-Equalizer. Use Manual. Digital. Terrestrial. Ref. : 6505

User Manual. Profiler Revolution Ref PATENT PENDING. SW Version 1.3.0

User Manual. SCR Multiswitch Ref. 9744SKY, 9746SKY, 9748SKY

User Manual. dcss/dscr Multiswitch 9732

User Manual. dcss/dscr Multiswitch 9733PL 9734PL

User Manual. HDMI Modulator Ref & SW Release

Multi channel programmable Filter-Amplifier

DMOD1200MS. HDMI Modulator. User Manual PLEASE READ THE MANUAL COMPLETELY BEFORE USE V.17.09

user manual Colosseum 8500D

ATS50SAW Programmable Selective Amplifier

AT450SAW Programmable Selective Amplifier

AT47SAW Programmable Selective Amplifier

HDMI 1-in 1-out Extender via CAT-5e/ CAT-6

USER MANUAL DUX-TX DUX-RX HDMI EXTENDER

User guide. Stand alone Multiswitches SMC Cascadable Multiswitches SMU Amplifiers. Multiswitches

LINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1

LINK EXT40-4KUHD 4:4:4 HDR HDBaseT Extender. User Manual. Version: V1.0.1

User Manual. UNIVERSE Ref. 8600

User Manual. UNIVERSE Ref. 8600

Single cable multiswich programmer PC102W

User Manual CS-HDBTLPOER m HDBaseT Extender with Bi-directional PoE. Version: V1.0.0

Operating Instructions

SAT IF distribution system

MAX T200 HD QUICK INSTALLATION GUIDE

beyond your expectations

FD Trinitron Colour Television

Bring High-Definition to your life!

4KEX70-L. HDBase-T Lite Extender. User Manual

MX-DIGITAL COAXIAL CONVERTER MX-1226

HDTV Supply Inc. reserves the right to make changes in the hardware, packaging and any accompanying documentation without prior written

HDBaseT Extender Over Single Cat5e/6 cable

Operating Instructions

Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-CP-12 (13/12) P.160-CP-16 (13/16)

ZVOX AccuVoice TV Speaker Model AV203

ZVOX AccuVoice TV Speaker Model AV203

TFT-LCD TV USER MANUAL W102T READ CAREFULLY BEFORE OPERATION W102T

Operating Instructions

Grandbeing. HDMI Splitter(Asynchronous Switching Method) Operating Instructions(P/N of this Instructions is INSGB07SW0102)

User Manual. UNIVERSE Ref SW Release

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

Evolution Digital HD Set-Top Box Important Safety Instructions

Grandbeing. HDMI Matrix. Operating Instructions(P/N of this Instructions is INSMX0404-HH1) FEATURES

Johansson Catalogue EDITION 2013

Register your product and get support at SDV5122/27. EN User manual

DM-1CH SD DVB-T MODULATOR INSTRUCTION MANUAL

HDTV Supply. Mega Scaler. Operating Instructions FEATURES

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

HD Digital Set-Top Box Quick Start Guide

SquareLED - Aura Bar & Matrix Beam Light 100

IMPORTANT SAFETY INSTRUCTIONS

Grandbeing. HDMI Convertor. Operating Instructions(P/N of this Instructions is INSMS A) FEATURES

ZVOX AccuVoice TV Speaker MODEL AV150.

V/L V/H H/L H/H. Satellite - Input. Programmable Cascadable switch. with 32 User Bands with Terrestrial input & 1 Legacy port


Operating Instructions

28 4K LED monitor. User Manual M284K

HDBaseT RECEIVER B-520-RX-330-IR INSTALLATION MANUAL

Operating Manual. DVB-T Meter MFK 16

Grandbeing. HDMI Matrix (Router Type) Features

Grandbeing. HDMI Splitter. Operating Instructions(P/N of this Instructions is INSSP )

Q-TV2. User Manual. for Screens

Grandbeing. HDMI Extender (By CAT-5E/6 cable) Operating Instructions(P/N of this Instructions is INSEX0101-U30/U31) FEATURES

Satellite B or D. Satellite Inputs (LNB Trunk)

HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL

User manual Transmodulators. Ref. 5103S/5103T/5103Q/5130

HDMI Converter. Operating Instructions(P/N of this Instructions is INSYH0101)

HDBaseT RECEIVER B-540-RX-330-IR INSTALLATION MANUAL

User s manual OLY 9X K OLY 9X OLY 9V. User s Guide. Headend cascade multiswitch OLY 9X K Cascade multiswitch OLY 9X. Cascade line amplifier OLY 9V

Bring High-Definition to your life!

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

Johansson Catalogue EDITION 2012

27'' Full HD LED Monitor KALED27MONSC Quick Start Guide

Utility Amplifier GA6A Model

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

Grandbeing. HDMI Converter. Operating Instructions(P/N of this Instructions is INSSH S) FEATURES

Installation Manual VIP 1003

Applications & Features of the SB- SDQM- 2130

Digi-Scart. Digital Terrestrial Receiver. Ref MET802

SATRI AMPLIFIER AMP-51R. Owner s Manual

OWNER S MANUAL HD-2CAT-1080P-130. Binary 2CAT Extender WELCOME TO THE BINARY BRAND OF PRODUCTS

NS-3 RF Noise Source Operation Manual

XO-231 USER S MANUAL. Crossover ENGLISH

Installation location

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s

Grandbeing. HDMI Splitter. Operating Instructions(P/N of this Instructions is INSSP0108)

Stratos Duo RGB. User Manual. Order code: EQLED371

2.0 Wall Mount TV Soundbar Instruction Manual

1812R Blues King 12. User Manual

Charlie Foxtrot Features include:

DIGITAL SET TOP BOX STB 7017 INSTRUCTION MANUAL

Model 1606 Super. User Manual

Technote 1: Setting up ZA- 431/331 processor modules


User Manual High Definition Digital Set Top Box DVBT9070 Please read this User Manual carefully to ensure proper use of this product and keep this man

PNP300 / PNP300UN / PNP350

Configuration and setting guide. ONE series ONESAT ; ONE118 ; ONEHOME. Programmable multichannel amplifiers

Catalogue. MDU Collective use. SFU Individual use. Edition 01/02/2010


Check our knowledge base at

Transcription:

R Ref. : 6602 Multi Channel Programmable FilterAmplifier User Manual Digital Terrestrial B III B III VHFUHF UHF1 24V 0 22 khz UHF2 24V 18V 24V 24V 13V 0V UHF3 III III VU GND R MULTI CHANNEL PROGRAMMABLE FILTERAMPLIFIER Digital Terrestrial Ref.: 6602 Stop Channel Slope ON / OFF Split UHF Auto Level Data Import Exit Data + 15V IN Output Test (30 db) FEATURES Designed for both digital and analogue Satellite and Terrestrial channels, 1 input + 6 Terrestrial inputs : B III / B III / VHFUHF and 3 UHF inputs splitted over 10 UHF programmable clusters, Each cluster can have 1 to 7 channels bandwidth, Easy programming by using one rotary / push button viewed on 2 digits display and LEDs for each cluster and each input, 'COPY' function in order to transfer all settlements from one unit to another reducing time of installation, High selectivity filters, Low noise figure amplifiers, High gain and output power, VHFUHF split band amplifiers with interstage attenuators for VHFUHF, Automatic leveling of signal or manual by attenuator with 1 db step for accurate equalization Selectable remote power on VHFUHF and UHF inputs, 0 13 18V / 0 22 khz remote power for LNB, 30 db Test output.

2

15V + IN 24V III III VU ON / OFF Slope 24V 18V 24V 24V 13V 0V 0 22 khz R Digital Terrestrial GND SAFETY INSTRUCTIONS Read carefully these instructions before connecting the unit. The operating voltage is indicated on the adapter. To prevent fire, short circuit, shock hazard: Do not expose the unit to rain or moisture. Install the unit in a dry location without infiltration or condensation of water. Do not expose it to dripping or splashing. Do not place objects filled with liquids, such as vases, on the apparatus. If any liquid should accidentally fall into the cabinet, disconnect the power plug. Refer to qualified technician before it's further operation. To avoid any risk of overheating: Install the unit in a well aery location and keep a minimum distance of 15 cm around the apparatus for sufficient ventilation. Do not place any items such as newspapers, tablecloths, curtains... on the unit that might cover the ventilation holes. The unit must not be exposed to any source of heat (sun, heater,...). Do not place any naked flame sources, such as lighted candles, on the apparatus. Do not install the product in a dusty place. Pull out power plug to make the different connections of cables. To avoid electrical shock, do not open the housing of adapter. Cleaning : Only use a dry soft cloth to clean the cabinet. Do not use solvent. Servicing : For repairing and servicing refer to qualified personnel. Mounting 212.5 mm. (5) 0 22 khz B III B III 24VVHFUHF 24V UHF1 18V 24V UHF2 24V 13V 0V UHF3 (2) (3) III III VU Stop Channel Slope ON / OFF MULTI CHANNEL PROGRAMMABLE FILTERAMPLIFIER R Auto Level Data Import Digital Terrestrial Ref.: 6602 GND (1) 185 mm. (1) Earthing (2) Place the adapter in its holder (3) Connect the power supply to the amplifier (4) Plug the mains cable to the adapter (5) Click the adapter holder to the amplifier Split UHF Exit Data + 15V IN Output Test (30 db) (5) (4) 15 cm. 15 cm. B III B III VHFUHF UHF1 MULTI CHANNEL PROGRAMMABLE FILTERAMPLIFIER UHF2 UHF3 15 cm. Wall Ventilation 15 cm. IMPORTANT : this amplifier is equiped with a fan on the back side to improve cooling capacity. Leave a minimum space of 15 cm. around the product to guarantee a maximum ventilation. Ref.: 6602 Stop Channel Auto Level Data Import Split UHF Exit Data Output Test (30 db) 15 cm. Ventilation 3

DESCRIPTION BIFM BIII / DAB 0 13V 18V 0 22 khz UHFVHF UHF1 UHF2 UHF3 LEDs for Inputs and Clusters Grounding 2 Digit Display Mains 230V~ Rotary / Push Button DSUB9 Connector Mode / Function LEDs Output Test Output 4

OPERATION All parameters are set with the rotary push button. Each function and parameters are shown on 2 digits display and different LEDs. Programming Make all the necessary connections and connect amplifier to mains. The software version is displayed, followed by a dot. Push on the rotary button for more than 3 seconds to enter into programming mode. Enter programming mode 3sec. Turn the button to select the desired mode. Mode is indicated with a GREEN colored LED. = green LED = red LED Inside the mode, turn the button to select the parameter (input, cluster, channels, level...) III III VHFUHF Input and Cluster LEDs Display Push the button to confirm the parameter setting. LED returns to a GREEN color. Repeat this section to set all parameters Turn the button to select Exit mode. Exit A dot is displayed. Exit programming mode Note : The amplifier will go in "standby" and will display a dot after 1 minute if the rotary / push button is not activated. 5

CLUSTER PROGRAMMING Setting clusters / UHF input The amplifier has 3 UHF inputs which are splitted over 10 clusters. There are three possible configurations : Input Number of cluster(s) UHF1 2 2 2 UHF2 8 7 5 UHF3 0 1 3 UHF1 clusters are indicated by the YELLOW LEDs n 1 and 2. UHF2 clusters are indicated by the RED LEDs n 3, 4, 5, 6, 7, 8, 9 and 10. UHF3 clusters are indicated by the GREEN LEDs n 8, 9 and 10. To set the number of cluster(s) per input : Turn the button to select Split UHF mode. Split UHF Split UHF The LED is red. Turn the button to set one configuration : III III VHFUHF UHF1 cluster indicator UHF2 cluster indicator UHF3 cluster indicator Split UHF Notes : UHF1 is set for 2 clusters, UHF2 and UHF3 are set for different number of cluster(s). Each cluster can be switched off (Park function). For example if you only need one cluster for UHF1, set the second cluster on channel 00 to switch it off (see following paragraph "Setting channels / cluster"). 6

Setting channels / cluster Each cluster has a bandwidth which can be programmed from 1 to 7 channels : To set the channel(s) per cluster : In the following example cluster 1 is set for channel 22 to channel 26. Turn the button to select the mode. Mode is indicated with a GREEN colored LED. = green LED = red LED Inside the mode, turn the button to select the cluster to be set. III III VHFUHF LED n 1 Turn the button to select the mode. Turn the button to select the start channel Display Turn the button to select the Stop Channel mode. Stop Channel Stop Channel Turn the button to select the stop channel Display Stop Channel Repeat this section to set all clusters 7

Notes : Single channel mode : When the is selected, the Stop Channel is automatically set at the same value. Park function : to switch off the cluster, select and set 00. The Stop Channel goes automaticaly to 00. If there are overlapping clusters, the display dots will blink alternately. cluster 1 ch22 ch26 Cluster 1 = ch 22 to ch 26 Cluster 2 = ch 25 to ch 29 ch25 ch29 channel cluster 2 8

To check the channel settings of each cluster : Turn the rotary button to select. The LED is GREEN. Turn the button to choose the cluster to be checked. The display shows the channels which have been set. Examples : Cluster is parked. Cluster is set to channel 22. Blinking 22 and 26: cluster is set from 22 to 26. Push the button to exit. The LED is GREEN. 9

LEVEL ADJUSTMENT Levels are manually set for each input and / or automatically for the UHF clusters. Automatic level setting The levels of BIII / BIII / VHFUHF / are not processed in the Auto Level function. Turn the button to choose the Auto Level. Auto level The LED is GREEN. Push the rotary button for more than 3 seconds to start the Auto Level function. Auto level 3sec. The level of each cluster is set automatically. The actived LED indicates the cluster which is being processed. The display shows the value of attenuation. This procedure will take about 1 to 2 minutes, depending on the number of channels and clusters to be equalized. When the LED is GREEN, the procedure is finished. Auto level The LED is GREEN. Each cluster's LED shows the status of equalization. LED off : parked cluster LED on : correct level LED blinking slowly : signal is too weak LED blinking rapidly : signal is too strong Notes : The automatic level adjustment set the output level of the clusters at 100 dbµv (for an input level between 50 to 80 dbµv). If the input level is less than 50 dbµv, the LED will blink slowly after the automatic level adjustment. If the input level is higher than 80 dbµv, the LED will blink rapidly after the automatic level adjustment. Adjust the input level (attenuation or amplification) if necessary. The general attenuator is fixed to 0 after the automatic level adjustment. It can be adjusted from 9 to +10 to get a level between 91 to 110 dbµv (see "General UHF level setting"). The level of each cluster can be adjusted independently (see "manually level setting). IMPORTANT : the 10 LEDs indication will not be changed after setting the levels manually. 10

After automatic level setting procedure, the general level of the UHF signals (clusters and the UHF part of the VHFUHF input) can be adjusted from +10 db to 9 db in steps of 1 db. General UHF level setting Select all the clusters and VHFUHF. Turn the button to choose the mode. Turn the button to select all UHF. III III VHFUHF All LEDs are activated Turn the button to select the mode. Turn the button to set the general level, variable from +10 db to 9 db. 11

Manually level setting To set manually the level. Select the desired input or cluster. Example : setting the level of BIII Turn the button to choose the mode. Turn the button to select BIII. III III VHFUHF LED is activated Turn the button to select the mode. Turn the button to set manually the level, variable from 20 db to 0 db (30 db to 0 db for clusters). Repeat this section to set all levels 12

OPERATION Select the input. Turn the button to choose the mode. Turn the button to select. III III VHFUHF LED is activated Display shows the status ON or OFF 13

To set the Gain. Turn the button to select the mode. Turn the button to set the level, variable from 20 db to 0 db. To set the Slope. Turn the button to select the Slope mode. Slope Slope Turn the button to set the slope, variable from 0 db to 9 db. Slope Slope 0 db 9 db 950MHz Freq. 2300MHz 14

To switch OFF the amplifier Turn the button to choose the mode. Turn the button to select. III III VHFUHF LED is activated Turn the button to select the ON/OFF mode. ON/OFF ON/OFF Turn the button to switch OFF the amplifier. ON/OFF 15

15V + IN III III VU ON / OFF 24V Slope 24V 18V 24V 24V 13V 0V 0 22 khz R Digital Terrestrial GND 15V + IN III III VU ON / OFF 24V Slope 24V 18V 24V 24V 13V 0V 0 22 khz R Digital Terrestrial GND COPY FUNCTION This function allows to transmit all settings from one unit to another unit. All actions have to be done on the SLAVE unit. The MASTER unit remains in Standby. B III B III VHFUHF UHF1 UHF2 UHF3 B III B III VHFUHF UHF1 UHF2 UHF3 MULTI CHANNEL PROGRAMMABLE FILTERAMPLIFIER MULTI CHANNEL PROGRAMMABLE FILTERAMPLIFIER Ref.: 6602 Ref.: 6602 Stop Channel Auto Level Stop Channel Auto Level Data Import Data Import Split UHF Exit Data Split UHF Exit Data Output Test (30 db) Output Test (30 db) SLAVE MASTER Connect master and slave unit with a DSUB9 male/male crossed cable. Then connect mains to the units. Data The software version is displayed, followed by a dot. Push on the rotary button for more than 3 seconds to enter into programming mode. Turn the button to select the Data Import mode. 3sec. Data Import Data Import AL is displayed Push the rotary button to confirm Data Import. The software version is displayed, followed by a dot. Note : If a problem occurs during data transmission the display will show an error message : Possible causes are : wrong type of cable, no cable, bad pin contacts. 16

15V 15V + IN + IN 24V III III VU ON / OFF Slope 24V III III VU ON / OFF Slope 24V 18V 24V 24V 13V 0V 0 22 khz R Digital Terrestrial 24V 18V 24V 24V 13V 0V 0 22 khz R Digital Terrestrial GND GND GENERAL RESET This function can reset all clusters and attenuators to zero. Disconnect the mains power. B III B III VHFUHF UHF1 UHF2 UHF3 MULTI CHANNEL PROGRAMMABLE FILTERAMPLIFIER Ref.: 6602 Stop Channel Auto Level Data Import Split UHF Exit Data Output Test (30 db) Keep on pressing the button, until the mains is connected again. B III B III VHFUHF UHF1 UHF2 UHF3 MULTI CHANNEL PROGRAMMABLE FILTERAMPLIFIER Ref.: 6602 Stop Channel Auto Level Data Import Split UHF Exit Data Output Test (30 db) The software version is now displayed followed by a dot. Release the button. 17

BLOCK DIAGRAM Att. 20 db BIII BIII VHFUHF UHF 1 UHF 2 UHF 3 DC DC DC DC Att. 30 db UHF TAP VHF TAP General Att. 20 db High Power UHF VHF OUT Auto Level Test 30 db 0/13/18 V 022 khz Att. 20 db Slope 9 db 18

TECHNICAL SPECIFICATIONS! " # $% " &' $% " (&' " ) #*+!,., / 0. + 1 / % BIFM 47108 BIII 174240 VHFUHF 47240 + 470862 UHF 1 470862 UHF 2 470862 856 (1 to 7 channels / cluster) UHF 3 470862 35 20 40 20 40 20 2 2 2 8 7 5 55 30 0 1 3 +10 db to 9 db 5 80 118 5 80 118 5 80 VHF:118 / UHF:123 6 80 123 10 db / 10 MHz >10 >10 >10 >10 >10 >10 24 V 24 V 24 V 24 V 100 ma in Total 30 DSUB9 connector 230 V~ / 15 V DC / 45 VA 5 to +50 265 x 220 x 95 9502300 40 20 9 9 90 116 / TERR. > 30 db TERR. / > 25 db >10 01318 V / 300 ma and 022 khz * TERR.: 54 db / IM3 : 35 db / IM3 19

R UNITRON n.v. Frankrijklaan 27 B8970 Poperinge Belgium TEL +32 5733 3363 www.johansson.be FAX +32 5733 4524 email: sales@johansson.be Specifications are subject to change without notice. 05/05