COVER PAGE FOR TEST REPORT

Similar documents
COVER PAGE FOR TEST REPORT

SPECIFIC TECHNICAL CRITERIA

File E64388 Vol. 1 Sec. 106 Page 1 Issued: and Report Revised:

File E Vol. 1 Sec. 89 Page 1 Issued: and Report

Electrical Specifications

POWER. DA10-M Series. 10 Watts. Data Sheet. Total Power: 10 Watts Input Voltage: Vac # of Outputs: Single, 5 Volts SPECIAL FEATURES

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS

File E Vol. 1 Sec. 88 Page 1 Issued: and Report Revised:

File E Vol. 1 Sec. 75 Page 1 Issued: and Report Revised:

with type designation(s) ECO38, -40, -43, -46 and ECP32, -34, 3 phases, 4 poles, single or double bearings, brushless A.C. generator.

Secto Design Oy Kauppalantie Kauniainen Finland tel fax

llen-bradley 194R-HM4-NFPA3

Australian and New Zealand Energy Performance and Marking Requirements for External Power Supplies

Model Number Structure

DC-to-DC Technology. 135 mm LOW-NOISE FAN FEATURES

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

KRF EMC Filters Installation, Operation and Maintenance Manual

Test Report. Measurement of Low Power Consumption of Electric and Electronic Appliances. Tested by (name + signature)...

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

4 Wiring Brochure Wiring and installation of specific control

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Instructions. P MHz 1X/10X Passive Probe

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS

MILLITARY SPECIFICATION SHEET

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

CERTIFICATE of EU TYPE-EXAMINATION

OPERATING MANUAL FIXED FLOW PUMP DRIVES

LED Driver Compact fixed output

XT-17M-B relay - Delay-off, 1 C/O, 16 A

LED Driver Linear / area fixed output

Product Data Sheet 4656 EZ

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

ALLEN BRADLEY TIMING RELAY

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

LED Driver Compact fixed output

IK10 IP68. Specifications. White (4 300 K typical) Warm white (3 000 K typical) Blue (470 nm) Other colors by request

Photoelectric Sensors E3F2

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Air Flow Static Pressure Characteristics MU1238A MU1238B MU1238L. Static Pressure. Static Pressure. Speed [r/min] [Pa] Speed

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

DT100 family (12 V, 24 V, 48 V) TDK-Lambda. TDK-Lambda UK Ltd. Kingsley Avenue, llfracombe, Devon, EX348ES, UK

File E Vol 1 Auth. Page 1 Issued: Revised: FOLLOW-UP SERVICE PROCEDURE (TYPE R)

Toronto Hydro - Electric System

Series CT7N Bimetallic Overload Relays

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

TEST REPORT COMMISSION REGULATION (EU) No 1194/2012 Ecodesign requirements for directional lamps, light emitting diode lamps and related equipment

Type Contact form Model

Modular Lube Lubrication Systems System Controls

02/11/2015

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

HXi High Performance Power Supply Series Corsair HX1000i Power Supply

3G-SDI Extender via Single Mode Fiber LC Simplex Connector Extends 3G-SDI Link Up To 20 Kilo Meters

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

OT 100/ /700 P5

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

Certificate of Compliance

Safety Codes Council Conference Banff C Panel Discussion

AS/NZS :2011

FCC Part 15 Subpart B Test Report. FCC PART 15 Subpart B Class B: 2014

Specifications. Reference Documentation. Performance Conditions

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

Indoor Linear 80W Driver SI-C215280N2KR

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LED Driver Compact fixed output

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

A V 50Hz / V 60Hz

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

Nessie Coils for VDH and VDHT valves

Circuit-Breakers for Motor Protection Series 8523/8

Bulletin 190 IEC Modular Starter System

Selection table SITOP power supplies

Product Data Sheet 4656 ZW

CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. STV-4101: V 30A (18) IEC C13 + (6) IEC C19 Outlets

SUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL

Linear flow controls VFC Linear flow controls with actuator IFC

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

GR circuit breaker - hydraulic magnetic, Datasheet

Procedure And/Or Report Material

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Product Data Sheet 8506 VW-691

HDMI Extender Via One MPO Fiber MPO Connector Extends HDMI Link Up To 200 Meters

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

Immersion Pumps HCT (High Chem) sealless

American National Standard for Lamp Ballasts High Frequency Fluorescent Lamp Ballasts

Panel-Mounted Thermostat

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

74F273 Octal D-Type Flip-Flop

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Gear Pump Units For single-line centralized lubrication systems

Data Sheet Definite Purpose Contactors Ex9CK Series

RF CONNECTORS RFC SERIES

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Transcription:

Issue Date: 2009-04-28 Page 1 of 3 Report Reference # E132002-A94-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): Power Supplies for Information Technology Equipment Including Electrical Business Equipment QQGQ, QQGQ7 Listing AC to DC Adaptor DP4012N3M, DP4012N2M DP4009N3M, DP4009N2M DP4015N3M, DP4015N2M DP4018N3M, DP4018N2M DP4024N3M, DP4024N2M DP4048N3M, DP4048N2M For Models DP4012N3M, DP4012N2M: Input:100-240 Vac, 50/60 Hz, 1.0A, 49W Max. Output:12 V, 3.33A Max For Models DP4009N3M, DP4009N2M: Output:9 V, 4.44A Max For Models DP4015N3M, DP4015N2M: Output:15 V, 2.67A Max For Models DP4018N3M, DP4018N2M: Output:18 V, 2.22 A Max For Models DP4024N3M, DP4024N2M: Output:24 V, 1.67A Max For Models DP4048N3M, DP4048N2M: Output:48 V, 0.84A Max Standards: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03 (Information Technology Equipment - Safety - Part 1: General Requirements) Applicant Name and Address: ASTEC INTERNATIONAL LTD 16TH & 17TH FL, LU PLAZA, KWUN TONG, 2 WING YIP ST, KOWLOON HONG KONG Copyright 2009

Issue Date: 2009-04-28 Page 2 of 3 Report Reference # E132002-A94-UL-1 This Report includes the following parts, in addition to this cover page: 1. Specific Inspection Criteria 2. Specific Technical Criteria 3. Clause Verdicts 4. Critical Components 5. Test Results 6. Enclosures Copyright 2009

Issue Date: 2009-04-28 Page 3 of 3 Report Reference # E132002-A94-UL-1 This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. Any information and documentation provided to you involving UL Mark services are provided on behalf of Underwriters Laboratories Inc(ULI) or any authorized license of ULI. Test Report By: Reviewed By: Steve Chiu Associate Project Engineer UL International Limited Brian Wong Project Engineer UL International Limited Copyright 2009

Issue Date: 2009-04-28 Page 3 of 34 Report Reference # E132002-A94-UL-1 SPECIFIC TECHNICAL CRITERIA UL 60950-1:2005 (2nd Edition) Information technology equipment - Safety - Part 1: General requirements Report Reference No... : E132002-A94-UL-1 Compiled by... : Steve Chiu Reviewed by... : Brian Wong Date of issue... : 2009-04-28 Standards...: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03 (Information Technology Equipment - Safety - Part 1: General Requirements) Test procedure...: Listing Non-standard test method... : N/A Test item description... : AC to DC Adaptor Trademark... : EMERSON Network Power Model and/or type reference...: DP4012N3M, DP4012N2M DP4009N3M, DP4009N2M DP4015N3M, DP4015N2M DP4018N3M, DP4018N2M DP4024N3M, DP4024N2M DP4048N3M, DP4048N2M Rating(s)...: For Models DP4012N3M, DP4012N2M: Input:100-240 Vac, 50/60 Hz, 1.0A, 49W Max. Output:12 V, 3.33A Max For Models DP4009N3M, DP4009N2M: Output:9 V, 4.44A Max For Models DP4015N3M, DP4015N2M: Output:15 V, 2.67A Max For Models DP4018N3M, DP4018N2M: Output:18 V, 2.22 A Max For Models DP4024N3M, DP4024N2M: Output:24 V, 1.67A Max For Models DP4048N3M, DP4048N2M:

Issue Date: 2009-04-28 Page 4 of 34 Report Reference # E132002-A94-UL-1 Output:48 V, 0.84A Max Particulars: test item vs. test requirements Equipment mobility... : transportable Connection to the mains... : pluggable A Operating condition... : continuous Over voltage category... : OVC II Mains supply tolerance (%)... : +10%, -10% Tested for IT power systems... : Yes IT testing, phase-phase voltage (V)... : N/A Class of equipment...: Class I (earthed) for models DP4012N3M, DP4009N3M, DP4015N3M, DP4018N3M, DP4024N3M, DP4048N3M; Class II (double insulated) for model DP4012N2M, DP4009N2M, DP4015N2M, DP4018N2M, DP4024N2M and DP4048N2M Mass of equipment (kg)...: <0.5 Kg Pollution degree... : PD 2 IP protection class... : IP X0 Possible test case verdicts: - test case does not apply to the test object... : N / A - test object does meet the requirement... : Pass - test object does not meet the requirement...: Fail (acceptable only if a corresponding, less stringent national requirement is "Pass") General remarks: - "(see Enclosure #)" refers to additional information appended to the Test Report - "(see appended table)" refers to a table appended to the Test Report - Throughout the Test Report a point is used as the decimal separator

Issue Date: 2009-04-28 Page 5 of 34 Report Reference # E132002-A94-UL-1 GENERAL PRODUCT INFORMATION: CA1.0 CA1.1 Report Summary N/A CB1.0 CB1.1 Product Description AC Power Adapter intended for Information Technology Products, switch mode construction with plastic enclosure. CC1.0 CC1.1 Model Differences Models DP4048N3M, DP4024N3M, DP4018N3M, DP4012N3M, DP4009N3M and DP4015N3M are identical to each other except output ratings, transformer T1, and ratings of some non-critical components. The Model DP40XXN2M is identical to Model DP40XXN3M except for the class of production. The Model DP40XXN2M are class II production, Model DP40XXN3M are class I production. (XX can be 09, 12, 15, 18, 24, 48) CD1.0 CD1.1 Additional Information The label is a draft of an artwork for marking plate pending approval by National Certification Bodies and it shall not be affixed to products prior to such an approval. This Test Report is re-issued with the original report number: E132002-A94-CB-1 issued 2009-05-05, with CB Certificate No. (DK-15733) issued 2009-05-07 This Report were deemed to amended, due to: 1. Add model nos. - Models DP4009N2M, DP4009N3M: Input: 100-240 Vac, 50/60 Hz, 1.0 A, 49W Max. / Output: 9 V, 4.44A Max - Models DP4015N2M, DP4015N3M: Input: 100-240 Vac, 50/60 Hz, 1.0 A, 49W Max. / Output: 15 V, 2.67A Max 2. Correct TMP testing location name from "Astec Power Supply (Shenzhen) Co Ltd" to "Astec International Ltd". This Test Report is re-issued with the original report number: E132002-A94-CB-2 issued 2009-06-23, with CB Certificate No. (DK-16081) issued 2009-06-24 This Report were deemed to amended, due to: 1. Add model nos. - Models DP4018N2M, DP4018N3M: Input: 100-240 Vac, 50/60 Hz, 1.0 A, 49W Max. / Output: 18 V, 2.22A Max - Models DP4024N2M, DP4024N3M: Input: 100-240 Vac, 50/60 Hz, 1.0 A, 49W Max. / Output: 24 V, 1.67A Max - Models DP4048N2M, DP4048N3M: Input: 100-240 Vac, 50/60 Hz, 1.0 A, 49W Max. / Output: 24 V, 0.84A Max 2. Add alternate Output Cord style 1185. 3. Correct Transformer manufacturer from Emerson (E209189) to Astec Internation Limited

Issue Date: 2009-04-28 Page 6 of 34 Report Reference # E132002-A94-UL-1 (E94225) CE1.0 CE1.2 CE1.3 CE1.4 CE1.5 CE1.7 Technical Considerations The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer s specification of: 40 C at full load, 60 C at half load. The means of connection to the mains supply is: Pluggable A The product is intended for use on the following power systems: IT, TN The equipment disconnect device is considered to be: Appliance inlet The product was investigated to the following additional standards: EN 60950-1:2006 (which includes all European national differences, including those specified in this test report). CE1.8 The following accessible locations (with circuit/schematic designation) are within a limited current circuit: Secondary Output CE1.13 The following are available from the Applicant upon request: Installation (Safety) Instructions / Manual