Collimation and Light Field Brightness

Similar documents
QUALITY CONTROL AND PATIENT DOSES FROM X-RAY EXAMINATIONS IN SOME HOSPITALS IN THAILAND

FFDM Quality Control in Canada - a Vendor Neutral Approach

Equipment Quality Control for Digital Radiography February 22, Imaging Physics CancerCare Manitoba

Assessment of the Impact of Dark Signal on Image Quality in Computerized Mammography. Introduction

Overview. ACR Accreditation Update in Mammography. ACR Topics. Requirements Today. What s Coming For Tomorrow

The American College of Radiology Mammography Accreditation Program Screen-Film: Frequently Asked Questions (Updated: March 16, 2018)

Ride the Lightning. A Review of Radiographic Physics

Breast Imaging Essentials

Understanding CT image quality

CARESTREAM VITA/VITA LE/VITA SE CR System Long Length Imaging User Guide

FDA MAMMOSCAN FULL FIELD DIGITAL MAMMOGRAPHY SYSTEM MAMMOGRAPHY

World First Slim Cassette Type Digital Mammo. Upgrade Solution

Scope: All CT staff technologist

Performance Evaluation of Industrial Computed Radiography Image Display System

Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

Creating room. for your visions

Tutorial Cathode Rays Year 12 Physics - Module 9.3 Motors and Generators

Dental Line. High frequency intraoral x-ray unit. radiology ahead

Imaging solutions for any size patient and any size budget.

Intra-oral X-ray unit with high frequency DC generator. Product Data

MPKOMNP. kéï=~ë=çñw== d^ifiblp. j~áåíéå~ååé=fåëíêìåíáçåë=d^ifiblp=`çãñçêí=mirp. båöäáëü. Cover page

UArm. Series. Analog or Digital U-Arm System

Essentials of Digital Imaging

Startup and Shutdown (AeroDR Detector)

Quality Assurance Implementation at the Roberts Proton Therapy Center. James McDonough 3 August 2013

GUIDELINES ON THE USE OF DISPLAY SCREEN EQUIPMENT

DRAFT. Proposal to modify International Standard IEC

Comed Medical Systems Co., Ltd. Office 707, Woolim Lion s Valley I, 311-3, Sangdaewon-dong, Seongnam-si, Gyeonggi-do, Korea Tel:

Display Systems. Viewing Images Rochester Institute of Technology

G635. APPLIED SCIENCE Working waves ADVANCED GCE. Wednesday 27 January 2010 Morning. Duration: 1 hour 30 minutes

RAY-2000A Product Manual

Practix. Mobile Radiography. All a Bucky station needs plus mobility. Practix 400

Introduction. Edge Enhancement (SEE( Advantages of Scalable SEE) Lijun Yin. Scalable Enhancement and Optimization. Case Study:

-Technical Specifications-

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)

Television brian egan isnm 2004

Remote Control. degraded, causing unreliable operation. The recommended effective distance for remote operation is about 16 feet (5 meters).

Financial disclosure statement. Fluoroscopic Equipment Design: What s s Different with Flat Panel? Concept of flat panel imager

Corrigendum-II. Up to 30 th October 2018 till 17:00 Hrs. 31 st October 2018 till 17:00 Hrs. 2 nd November 2018 till 14:00 Hrs.

OPTICAL POWER METER WITH SMART DETECTOR HEAD

RSNA 2006 November 26 to December 1 Chicago. Guest author for ImPACT Dr. Koos Geleijns, Medical Physicist, Leiden University Medical Center.

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

2

ITS-I. Test station for evaluation of image quality of image intensifier tubes. Fig. 1. Photo of the ITS-I test station: a)photo, b)block diagram

Extender for HDMI over one CAT5

The Black Piranha Easy & Fast X-ray Quality Control

The Versatile and Powerful ACLxy. ACLxy

Entry Level Assessment Blueprint Audio-Visual Communications Technology

Prof. Greg Francis 1/3/19

Madero Ote. 686, Centro Histórico, C.P Morelia, Michoacán México. #300, Col. Cuauhtémoc, C.P Morelia, Michoacán, México

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

... A COMPUTER SYSTEM FOR MULTIPARAMETER PULSE HEIGHT ANALYSIS AND CONTROL*

JEFFERSON COLLEGE. Image Intensification & Equipment

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

Guidelines for Quality Assurance in Radiation Protection for Diagnostic X-Ray Facilities: Large X-Ray Facilities

FNP3 Series Tri-Lens for Nichia NS6x083 and NS6x183 LEDs

JEM 3010 Manual (2011 Edition)

In recent years, CT technology has undergone profound

Revised Textbook Edition Digital Radiography & PACS

What do we mean by workload? Number of scans Type of scans/mix of scans? Total mas Total dip

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

ziehm imaging ... dedicated to clinical innovation Ziehm Vista. TECHNICAL SPECIFICATIONS Most Versatile C-arm.

LUMIGEN INSTRUMENT CENTER X-RAY CRYSTALLOGRAPHIC LABORATORY: WAYNE STATE UNIVERSITY

Gouvernement du Canada. Government of Canada. Wireless. Communication and. Health. An Overview

CHAPTER 4: HIGH ENERGY X-RAY GENERATORS: LINEAR ACCELERATORS. Jason Matney, MS, PhD

Indoor/Outdoor 8MP 4K H.265 WDR PoE IR Bullet Network Camera

Cosmos2 The Economical X-ray Solution with the Best Image Quality and High Reliability

K Service Source. Apple High-Res Monochrome Monitor

PI MANUFACTURING Powered by Infinite Solutions

Mechanical aspects, FEA validation and geometry optimization

Azatrax Model Railroad Track Signal Control - Single Track

SPECTRO Series SPECTRO-3-50-UV-JR. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-UV-JR (incl. software SPECTRO3-Scope)

Staff dose and good prac/ces in CT guided IR procedures. Jonas Andersson Medical Physicist, Ph.D.

Australian/New Zealand Standard

STX Stairs lighting controller.

High Frequency X-Ray Technology. Wide Screen Control with Touch-Technology

Processing. Electrical Engineering, Department. IIT Kanpur. NPTEL Online - IIT Kanpur

Summer Grocery Shopping Assistant for the Visually Impaired(Grozi) Joo Byoung (Ave) Park Client: National Federation of the Blind.

FS3 Series Tri-Lens for SEOUL SEMICONDUCTOR Z-POWER P4 TM LEDs

X-ray Tube Housing Assembly H1076X H1076Y Print No.HA Release Date:

Promises and Perils of Proton Therapy Beam Delivery (Implications) or Towards Cost Effective Particle Therapy

NEMA XR 25 COMPUTED TOMOGRAPHY DOSE CHECK

Computer Graphics Hardware

How to use and maintain survey meters and a personal digital dosimeter - Materials for explaining radiation measurement equipment and devices -

decodes it along with the normal intensity signal, to determine how to modulate the three colour beams.

Hi! Let s get started.

HDMI to VGA Converter

Radiological Imaging. Software Version 3.6

CARESTREAM DIRECTVIEW Elite CR System

Technical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework

CytoFLEX Flow Cytometer Quick Start Guide

Graphing Your Motion

CARESTREAM DIRECTVIEW Elite CR System

Introduction. Characteristics (Note 1, 2) Parameters Typical Value Units Conditions

Confocal Application Notes Vol. 2 May 2004

Standard. Substitute Test or Procedure. Required Test or. 1 Scan Increment Accuracy. Initially and Annually Initially and Annually

THE OPERATION OF A CATHODE RAY TUBE

Data. X-ray Image Intensifier HIDEQ 23-3 ISP

Shad-o-Box X-Ray Camera Hardware Manual

K Service Source. Apple High-Res Monochrome Monitor

Transcription:

Collimation and Light Field Brightness

Physics and Reasoning

Principle 1: Primary X Ray beam is blocked by breast support table. Principle 2: Need to properly imageas as much breast tissue as possible. Note: Try to get as much chest wall tissue as possible. X rays must extend to edge. Detection as close to edge as possible. Pi Principle i 3: Rd Reduce extraneous light in image. Note: Exposing entire detection area will not increase dose or scatter.

Physics and Reasoning

Principle 4: Light field should indicate what area is being imaged. Note: Paddle can interfere with chest wall edge and can push patient away.

Test Procedure For Film Screen and CR Systems Cassette in holder and on top of breast support table, with scales placed as indicated, zeros at light field boundary. 18x24 cassette in holder and 24x30 on top. 24x30 cassette in holder and 24x30 on top at angle.

Test Procedure For DR (and CR) Digital Systems Please ensure that the free QuickTime Player from Apple is installed in order to play to movie: leadscalesetup_18x24.mov Note that current procedure is to support the compression paddle at 45mmand use manual control at 28kVp and 100mAs.

Test Procedure Lead scales used to mark light field edges and measure extent of x ray field. Phosphorstrips strips are for digital testing. Light field edge Phosphor strip placed at 13mm outside light field (2% SID) Chest wall A hold over from film screen which should be changed to 10mm Phosphor strip placed at 5mm from breast support edge for testing x ray field extent past chest wall.

Test Procedure Zero of four scales placed on light field edges. Note light field shining on breast support table. Fifth scale placed with zero at chest wall edge and phosphor at 5mm beyond. Scales may need to be taped in position. Scales establish light fieldposition relative to detector. Phosphors on scales establish tolerance of x ray field position relative to light field.

Test Procedure Compression paddle at standard height (45mm) should be supported. Scale taped to bottom of paddle with zero at chest wall edge. Phosphor on paddle scale is in x ray field as control test for glow.

Test Procedure Physics DPMA phantom in addition to an MTF tool, also contains a missing tissue tool. This phantom will already be imaged in large and mag views by a different test.

Test Procedure The light meter in collimation tests. The field light needs to be tested for brightness. The light used in small and large fields of view is measured. Background light (field light off) is also measured. The measurements are in lux.

Test Procedure As described in Digital Mammography Quality Control for the Mammographic Physicist, Revision 3.1 Tape four phosphor strips around breast support and cover with foil as in diagram 4. Add 45mm PMMA with scale at chest wall edge. Tape four scales with zero at light field edge Tape scale to compression paddle bottom, zeroed at chest wall edge. Lower paddle to make light contact. Measure background lightand field lightin in luxfor both small and large detector sizes.

Test Procedure Diagram 4

Example Test Image Digital Collimation Image (GE Essential 18x24 central) Zero at Edge of Paddle Zero at Chest Wall Light Field

Example Test Images Zero at Edge of Paddle Collimation test of 24x30 size on GE Essential

Example Test Image Collimation test of mag stand (1.4x) for Siemens Inspiration. i Zero at Edge of Paddle

Example Test Image IMSGiotto (non mag) DMPA phantom contains missingtissue scale which should show less than 7mm tissue pushed out.

Example Test Image GE Essential (non mag) Pushed out tissue is at border line condition.

Example Test Image DMPA phantom on GE Essential Mag Stand (1.5x)

Pitfalls of Test Be sure to avoid overlaps or ensure properly visible image. Tape scales to avoid shifts when compression paddle reattached. hd Take care to properly establish the light field edge.

Pitfalls of Test All image receptor sizes need to be tested. Be sure light field brightness and background have been measured. Be sure to observe phosphors in digital testing in darkened room.

Machine Specific Tips and Tricks GE Essential will reset light field to central position on paddle connection. Must position light field just before image. Please ensure you have the free QuickTime Player installed from Apple to play the included movie: GE_Essential_18x24_autoshift.movEssential autoshift

Machine Specific Tips and Tricks Note: Simple webcams require no additional software. They can be taped in position observing phosphors p while the physicist stays protected. As an option, webcams can capture video of phosphor. Wb Webcam taped dbeside tube port See QuickTime movie of central phosphor lighting: phosphorglow.mov.

Pass/Fail Criteria Detector and light field edges within 10mm Missing tissue at the chest wall: Achievable: 5 mm Acceptable: 7 mm Radiation field covers detector with extending past breast support, except possibly at chest wall by less than 5 mm Paddle extends no more than 5mm beyond chest wall. Light field intensity more than 160 lux above background. Must be corrected within 30 days.

Film Screen Spread Sheet Pass/ Fail criteria Onlyone smallrelevant section to complete. Sum of misalignments must be less than 13 mm Paddle edge not beyond chest wall by more than 7 mm.

Digital Spread Sheet (GE Essential) Acquisition sheet documents images. Pass/Fail Criteria Note Light Field Intensity

Pass/Fail Criteria DigitalTestingRev3.1: Collimation7 Light Field Intensity (GE Essential)

Pass/Fail Criteria DigitalTestingRev3.1: Collimation7 Light Field Dt Detector t Congruence (GE Essential)

Pass/Fail Criteria DigitalTestingRev3.1: Collimation7 X Ray Field Exceeds Limits (GE Essential) Thistest result isonly observable fromthe reaction This test result is only observable from the reaction of the phosphor strips during x ray exposure.

Pass/Fail Criteria DigitalTestingRev3.1: g Collimation7 Missing Tissue, Coverage and Compression Paddle (GE Essential)

For more information please refer to Digital Mammography Qualtity Control for the Mammographic Physicist, Revision 3.1