DICKSON ES120/ES120A DICKSON. Electronic Signal Data Logger. Specifications. Applications, Features, & Getting Started. Instructions / Operating

Similar documents
AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

On-screen display signal strength meter Version 1.02

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Quick Release Roof-Mount Kit MB700

SCALE & WEIGHT DISPLAYS

Field Test 2. Installation and operation manual OPDAQ Installation and operation manual

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)

EZ-LIGHT K30L Series With Independent Push Button Contact

PulseFlow FP100 Pulse to 4 20mA Flow Converter (Flow Rate Transmitter / Totalizer / Indicator)

TALKBACK INTERCOM SYSTEM VC-2927 CLOCK CONTROL CARD FOR THE VC-24

Instruction Manual DV5000 AV/ Component Bi-Directional DV- Video to Analog Converter

AES Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter

User Manual. Model 1372A and 1374A HDMI Switchers. 1T-SX-632 Model 1372A 2X1 Switcher. v1.3 2x1 SWITCHER. v1.3 INPUT ENHANCE POWER

CrossLine Generator Operation Manual

LED Series Sealed Backlights

EZCOM-1. PLC - to - AMS MESSAGE DISPLAY INTERFACE INSTALLATION AND OPERATING INSTRUCTIONS. Rev March, 2001

CS x1 RS-232 Computer Controlled Video Switcher. Instruction Manual

CardModule. Reference Manual. Series C DA Channel SDI to CVBS Converter. Version 1.0

Omnidirectional TV/FM Antenna

User Manual. Model 1351 DVI Repeater with HDCP

User s Manual. 4X1 HDMI Switcher Part #: DL-HDS41

Low Voltage Multifunctional LED Controller / DMX Decoder. Specification

TALKBACK INTERCOM SYSTEM V-2927 CLOCK CONTROL CARD FOR THE V-2924A

MS2540 Current Loop Receiver with RS485 Communication

4x1 HD Analog Audio Switcher

LBC-H2CS-T/R-Lite LINK BRIDGE TM HDBASET HDMI 2.0 EXTEDER 4 PLAY

MaxView Cinema Kit Quick Install Guide

True RMS AC/DC Mini Clamp Meter

Model R177M and R177S Baseband Switch

Warranty and Registration. Warranty: One Year. Registration: Please register your product at Port, or. or Windows.

Metal Electrode Meter

6x2 HDMI Switcher USER MANUAL.

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R. EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual

HDMI Extender over UTP Cable

DVI to HD-SDI Conversion Box

The smart valve with 3 Independent programs + 2 extra modes

Master Time Clock MTC Users Manual

45LM Series Modules. Features. Specifications. Plug-in Logic and Display Modules for Q45 Series Photoelectric Sensors

DUAL/QUAD DISPLAY CONTROLLER Operation Manual

INSTRUCTION MANUAL V Barometric Pressure Sensor. May Copyright 2007 Campbell Scientific (Canada)Corp.

1:4 VGA Hub EXT-VGA-144 USER S MANUAL.

BENESTON USER MANUAL AHD-ER03H. AHD to HDMI & VGA & AV Converter AHD-ER03H

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

EZ-LIGHT S18L Color General-Purpose Indicators

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

WaveRider Trouble Shooting Guide

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

4x1 HDTV Switcher USER MANUAL.

GeniSys Display. Contractor s Tool. Description / Applications. for the GeniSys Advanced Burner Control

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

BASIC PH METER BASIC PH METER KIT

VideoEase HDMI 3x1 Switcher Kit (110V) Installation Guide

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

3x1 HDMI Switcher USER MANUAL.

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

User Guide. HDMI Active Cable Extender. DVI-7370c

Introduction Congratulations and thank you for purchasing W Box Technologies 0E-HDMISPL2.

OPERATIONAL MANUAL EMZS CH Speaker Zone Selector. Version 1.6

VHF + UHF Amplified HDTV Antenna Model OA8000 & OA8001 Installation Instructions Reception Frequencies

4X1 Gefen TV Switcher GTV-HDMI N. User Manual

Operation Manual VMS 3.0 Video System

DVI-D Fiber Optic Cable

Model Number Structure

ARIS EXPLORER 1200 GETTING STARTED

VLHDMIEXTFIB_2017V1.0

Expand Your Factory Radio add Satellite Radio Harness Connection

Please read this manual before using the C961 Display. Suzhou Bafang Electric Motor Science-Technology Co., LTD

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

Chapter 1 : FCC Radiation Norm...3. Chapter 2 : Package Contents...4. Chapter 3 : System Requirements...5. Chapter 4 : Hardware Description...

User s Manual. Model Digital Sound Level Meter

User Guide. HDMI Fiber Optic Extender. DVI-7350a

VGA Extender LR EXT-VGA-141LR. User s Manual

User s Guide MWTC-REC6/UWTC-REC6. Wireless Transceiver. Shop online at omega.com SM

Warner Photoscanner MCS-500 Series LED Photoelectric Control

Electronic M.O.P Card. Instruction Manual Model D

Digi-Wave DLR-50. Digital Receiver. user guide MAN156D

USB-TG124A Tracking Generator User Manual

ZIG-POEPRO-70A. HDBaseT HDMI Extender

WINEGARD INSTALLATION MANUAL. Model GM Carryout Ladder Mount for mounting pipes with outer diameters between 1 to 1-1/8

ASKING FOR ASSISTANCE

5 Port DVI Splitter VIDEO WALLS VIDEO PROCESSORS VIDEO MATRIX SWITCHES EXTENDERS SPLITTERS WIRELESS CABLES & ACCESSORIES

Kramer Electronics, Ltd. USER MANUAL. Model: VA-14. 4x1 Balanced Audio Mixer

RS232 settings are internally definable via jumper blocks, to accommodate interfacing with a wide range of control products.

RS232 settings are internally definable via jumper blocks, to accommodate interfacing with a wide range of control products.

VideoStamp 8 TM. Eight channel on-screen composite video character and graphic overlay with real-time clock. Version 1.01

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

COMPOSITE VIDEO (BNC) TO VGA VIDEO FORMAT CONVERTER AND SCALER AT-RGB110

1x8 DVI DA USER MANUAL.

ZIG-POC-100. HDBaseT HDMI Extender

Model /29S RF Splitter

1x4 DVI Monitor Switcher

SyncGen. User s Manual

Instruction Manual RT-91600D-SL RR-91600D-SL Sixteen Channel Video Multiplexer With Remote Diagnostic Interface

MT03A Electronic converter for flow rate transmitters

User Manual DV-HDSS-41-TX. 4x1 4K Scaling Presentation Switcher with Dual Outputs. NOTE: See FSR LIT1628 API manual for serial commands.

USB Smart Power Sensor

User s Manual. Digital Media Converter Package Part #: DL-HDCAT

Satellite Receiver. Chapter REMOTE CONTROL USING THE MENUS USING TEXT FIELDS. About Your Satellite Receiver. What you ll find in this chapter:

Kramer Electronics, Ltd. USER MANUAL. Models: 6808, SDI-AES De-Embedder 6809, SDI-AES Embedder

For use with QED and hardwired control panels ONLY!

Transcription:

/A Electronic Signal Data Logger Contents: Product Applications and Useful Features Product Transmitter / DicksonWare Software Product Frequently Asked Questions Warranty / Software & FAQs &

Product Applications The Dickson sets a new standard in accurate, easytouse, affordable PC based recording. The will allow simultaneous monitoring of multiple variables with one data logger. With little effort, pressure, air movement, flow, fluid level, electrical properties, moisture, gas concentrations and much more can be monitored. Due to its small size and rugged design, the can be placed just about anywhere! The is ideal for researchers, building operators, test & equipment engineers and quality control personnel. DicksonWare makes reading recorded data on your PC easy! Importing data into a Word document, Excel spreadsheet or PowerPoint presentation is a snap. Product Features Simultaneous monitoring of multiple variables with one data logger Monitor pressure, air movement, flow, fluid level, electrical properties, moisture gas concentrations and much more 5 year battery life Stores 32,000 sample points (16,000 per channel) 2 user selectable channels Other Useful Features Delayed Start: Program how many Days, Hours and Minutes must expire before your unit begins logging. Real Time Monitoring: Monitor and graph your process as it happens and print and save from real time screen. (This feature should be used sparingly as it causes the battery to drain quicker) Customize Graphed Data: DicksonWare calculates Min, Max and Average of all data collected. Customize data by highlighting specific data points which will recalculate MIN, MAX and Average for highlighted information. Export Data: A snapshot of your graph or a realtime graph of points can be easily exported to other programs such as Excel or PowerPoint. CLICK ON THE FEATURES BUTTON IN THE SOFTWARE FOR DETAILED INSTRUCTIONS ON HOW TO USE ABOVE FEATURES AND MORE. Product A Range (unit only): 40 to 176 F (noncondensing) 40 to 176 F (noncondensing) Input: 0 to 5V, 0 to 20mA, 4 to 20mA, or 1 to 5V (user selectable) 0 to 15V Total Channels: 2 2 Input Connection: Screw Terminal Block Screw Terminal Block Sample Interval: 10 sec. to 24 hr. interval 10 sec. to 24 hr. interval Storage Capacity: 32,000 div. by 2 32,000 div. by 2 Resolution: 0.1 F 0.1 F Dimensions: 3.1 x 2.1 x 0.9 (79mm x 53mm x 23mm) 3.1 x 2.1 x 0.9 (79mm x 53mm x 23mm) Weight: 2 oz (56.7 g) 2 oz (56.7 g) Software FAQs & &

Instructions 1. 2. Install the DicksonWare Software. Connect the cable (supplied with the software) to the logger and to a working serial port on your computer. Setup Ensure dip switch settings. Remove the screw on the back of the case and position the switch for each channel according to the type of signal being supplied, ON for 0 to 20mA Current signal and OFF for 0 to 5Vdc signal. Connect your 0 to 5Vdc and/or 0 to 20mA transmitter(s) using the channel polarity indicated on the front label. A Setup Connect your 0 to 15Vdc source or transmitter(s) using channel polarity indicated on the front label. DO NOT CHANGE DIPSWITCH SETTINGS FOR A. 1. 2. Click the Setup button. When the setup window appears, all fields should be automatically filled in, this will confirm that DicksonWare has recognized the logger. Should all fields remain blank, refer to No Communication in the Trouble Shooting section of this manual. Once DicksonWare recognizes the logger, select the channels tab. Press the adjust button next to the desired channel which will bring up a channel adjustment window with two categories, ENABLE and USER DEFINED. In the Enable section, the Enable box should be deselected. If a channel is not going to be used, this will allocate all storage capacity to the active channel. You may also choose to change the label for that channel to reflect the actual variable being measured such as Temperature, Pressure or Flow. Following Setups Are For Models Only In the User Defined section, set the MIN and MAX input signal being supplied by your transmitter, units should show ma or V depending on what type of signal that channel is setup to receive. Now set the MIN and MAX range that applies to the programmed input signal. Changing these parameters in the A model will cause the logger to operate improperly. You may also want to type a variable in the units field that represents what is being measured such as F for Fahrenheit, PSI for pressure or gpm for gallons per minute. You may set the units for model A as well. To start logging, press the Clear button. This will delete all data currently stored. The logger is now sampling and ready for use. The default sample interval is 1 minute. Verify that the indicator light is flashing every 10 seconds. You may choose to change Default settings for sample interval and startdate and time. When changing these settings, the logger will automatically go through the clear process to accept your changes. NOTE: To conserve battery life when storing unit, press the Setup button and select the shortest Sample Interval and Stop When Full in the Samples section. Software FAQs & &

Transmitter / A powered transmitter is required to operate the /A.Any powered transmitter with a 420mA, 020mA, 05Vdc, 15Vdc or 0 to 15v (A) output signal may be used. To connect a transmitter to the logger, locate the terminal block on the side of the logger. Connect the positive wire of the transmitter to the positive terminal and the negative wire of the transmitter to the negative terminal of the appropriate channel. Tighten screws in terminal block to hold in transmitter wires. Repeat steps with second transmitter. Typical Setup, Current (ma) Power Supply Transmitter 1 Transmitter 2 Typical Setup, Voltage (V) Power Supply Transmitter 1 Transmitter 2 Software FAQs & & A Typical Setup, Voltage (V) Power Supply Transmitter 1 A Transmitter 2

DicksonWare Software Microsoft Windows compatible Allows for simple viewing and zooming of logged data Easy setup of Dickson Data Loggers including: User selectable sample intervals from 10 seconds to 24 hours Display temperature in C or F Delayed logger start times Logger data capacity can be set to wrap data or stop when full Allow for real time monitoring and graphing. Effortless exporting of data and graphs to other software Data can be viewed in tabular (numeric/table) or graphical formats Fast downloading of logged data 30 seconds (typical) from full logger Even shows battery power status for battery operated loggers : Compatible With: Microsoft Windows 95, 98, 2000, NT & XP PC Requirements: PC with 386 MHz or better microprocessor, 4 M RAM, 1 free COM (serial) port, CD drive Cable Type/Length: 9 pin male Dshell to male 2.5mm stereo plug, 6 long Computer Interface: RS232 COM (serial) port DicksonWare Version Required (minimum): See Specific Model for Version Requirement (for current pricing go to www.dicksondata.com or call 18003232448) Software Order # DicksonWare Software and Serial Download Cable A015 Cases Order # Locking Wall Mount Case Waterproof Pouch A715 A713 Other Order # Certificate of Validation N520 Software FAQs & &

Frequently Asked Questions Sample Interval: The Sample Interval determines how frequently the data logger will save a reading. Using DicksonWare Software, the user can set a Sample Interval ranging from 10 seconds to 24 hours in 10 second increments. A temperature logger with data storage of 32,512 set at a 10 second Sample Interval will record for 3.75 days, while the same logger set at a 1 minute Sample Interval will record for 22.5 days. Data Storage: Data Storage is the number of Sample Points a data logger can hold. You will find models that range from 7,680 samples to 32,512. A temperature logger with Data Storage of 32,512 and a sample interval set at 30 seconds would record for 11.25 days, while a temperature logger with Data Storage of 7,680 and the same sample interval would record for only 2.6 days. Does it have to stay connected to a PC in order for it to work? No. Unless you re viewing data in realtime you only connect the logger to a PC when you want to view / retrieve data. What happens when all the storage space is taken up? Do I have to throw it away? After you have downloaded the data, you simply clear the logger and it is ready to log more data. What happens if I leave it monitoring somewhere too long? The Data Loggers have two user selectable modes, Stop and Wrap. In Stop mode, they will quit logging data when the memory is full. In Wrap mode, the Logger will begin to overwrite the oldest data in its memory. Where can I put them? Depending on the Dickson model, just about anywhere. We have waterproof units, stainless steel models, units with probes, and units that handle extreme temperatures. Our wide selection of instruments should fit about any application. What is the biggest advantage of a Data Logger? Its data is logged, stored on a microchip inside the Data Logger. Data in electronic memory takes advantage of the power of a PC and software. * Store the data as you would store any document on your PC. * Retrieve archived data as easily as opening a file on your PC. * Share the data as you would any PC file, email, copy and paste. * Data can be imported into spreadsheet software and word processing documents. * Easily import data from multiple data loggers onto a single graph. How are they mounted? The smallest ones, about the size of a pager, can be wallmounted with Velcro or simply set anywhere you need to monitor. The larger units have keyhole slots for wall mounting and can also stand on their own. Software & For troubleshooting information, click here for the technical support page. FAQs &

Warranty Dickson warrants that the products it sells will be free from defects in material and workmanship under normal use and service for a period of twelve months after delivery. In the event of a claim under this warranty, the product or part must be returned to the factory for repair or replacement (shipping prepaid) with a Return Authorization Number (see Return Information above). It will be repaired at Dickson s option without charge. This warranty DOES NOT cover routine calibration, pen, chart and battery replacement. The foregoing warranty and remedy are exclusive and in lieu of all other warranties either expressed or implied. Dickson shall not be liable for consequential or incidental damages resulting from failure or malfunction of its products. Dickson makes no warranty for products not manufactured by it or for any products modified by buyer, or subject to misuse or neglect. Contact the factory (6305433747) for a Return Authorization (RA) Number before returning any instrument. The model number, serial number and a purchase order number will be requested before an RA number is issued. Carefully repack the instrument, label the outside of the box with the RA# and return the instrument (freight prepaid) to Dickson. All instruments that do not have the RA# clearly marked on the outside of the box will be refused. When returning instruments for credit, please include all accessories in shipment. Calibration/Freight charges are nonrefundable. NOTE: Dickson shall not be liable for consequential or incidental damages resulting from failure or malfunction of its products. Customer Satisfaction: Dickson takes pride in providing you, the customer, with the highest quality instrumentation. We welcome the opportunity to help you in any way possible. Whether it be a question or a new idea in documentation, the Dickson Company would like to hear your response. Please call our Customer Service Department at 18003232448 or (630) 5433747 (in Illinois). Software Return Policy: IMPORTANTRead your Software License Agreement carefully before installing software. DIckson will accept returns for replacement of defective disks and CDs only. Software & FAQs & 930 South Westwood Avenue Addison, Illinois 60101 Phone: (630) 5433747 Email: DicksonCSR@dicksondata.com