POWER CBM-175 Ref.3546 Terr -Sat Multiband Amplifier SAT IF UHF2 UHF1 DAB BI/FM DISTRIBUTION ELEMENTS UDU Series. Splitters - 2450 MHz 2-, 3-, 4-, 6- and 8-way shielded inductive splitters. Frequency range: 5-2450 MHz. Wall fixing, nickle-plated zinc diecast housing (2 screws attached). Grounding facilities. All ports F female connector. Unidirectional DC transit (max +24 VDC, 0.5 A) on all ports. The Splitter has a 9mm Pathway underneath to allow cable distribution. MODEL UDU-205 UDU-307 UDU-408 UDU-612 UDU-813 REF. 5350 5351 5352 5353 5354 No. of ways 2 3 4 6 8 3,6 6,8 8,1 11,8 11,9 Insertion loss 950-1550 MHz 4,1 8,5 9,1 13,5 14,1 1551-2300 MHz 4,8 9,7 10,4 15,1 15 35 25 24 28,5 26 Output isolation 301-862 MHz 34 21 22 25,5 28,4 950-2300 MHz 20 21 22,5 25 28 12 10 10 10 10 Dimensions mm 55x50x25 78x50x25 76x58x25 120x58x25 120x58x25 UDU-205 UDU-408 UDU-813 UDU-612 5353 IN UDU-408 Ref. 5352 4-WAY SPLITTER 5-2450 MHz 8.7 mm IN UDU-408 Ref. 5352 4-WAY SPLITTER 5-2450 MHz 110
Diverse Indoor Passive Elements with 65VAC/1A ing Directional Couplers (10 and 16 ) Two-way Splitter Power Inserter. Frequency range: 5-2150 MHz. Power passing (65 VAC / 1A) through all ports. Nickle-plated zinc diecast housing. Wall-fixing (2 screws attached). All ports: F female connector. Grounding facilities. 10 Directional Couplers MODEL CIS-110 CIS-116 REF. 3374 3375 2.0 1.6 950-1550 MHz 2.3 1.8 1551-2300 MHz 2.5 2.2 10.5 (±1.5) 16.0 (±1.5) Tap loss 301-862 MHz 10.5 (±1.5) 16.0 (±1.5) 950-2300 MHz 11.0 (±2.0) 16.0 (±2.0) Tap-to-Output isolation 15 18 Power passing through every port max 65 VAC / 1A CIS-110 2-way Splitter MODEL SIS-102 REF. 3376 No. of ways 2 4.2 Insertion loss 950-1550 MHz 5.0 1551-2300 MHz 5.8 5-47 MHz 12 Output isolation 48-862 MHz 20 950-2150 MHz 15 Power passing through every port max 65 VAC / 1A SIS-102 Power Inserter MODEL IIS-100 REF. 3377 0.8 Insertion loss 950-1550 MHz 1.0 1551-2150 MHz 1.3 12 950-2150 MHz 10 Voltage/Current of insertion max 65 VAC / 1A IIS-100 111
1-, 2-, 4- and 8-way shielded directional tap-offs. Frequency range: 5-2300 MHz. Wall fixing, nickle-plated zinc diecast housing (2 screws attached). Grounding facilities. All ports F female connector. DC tansit (max +24 VDC, 0.5 A) on the main line. UDL-100 Series. 1-way Tap-offs MODEL UDL-110 UDL-115 UDL-120 REF. 3226 3227 3228 Tap loss (± 0.7 ) 10 15 20 Dimensions (mm): 54x58x26 1.1 1.0 0.9 950-1550 MHz 1.7 1.7 1.6 1551-2300 MHz 2.3 2.2 2.1 29 28 31 301-862 MHz 29 27 28 950-2300 MHz 19 23 19 15 (TV) UDL-110 UDL-200 Series. 2-way Tap-offs MODEL UDL-210 UDL-215 UDL-220 REF. 3244 3245 3232 Tap loss (± 0.7 ) 10 15 20 Tap-to-tap isolation Dimensions (mm): 54x58x26 2.3 1.6 1.1 950-1550 MHz 3.0 2.0 1.9 1551-2300 MHz 3,7 2.6 2.6 26 29 31 301-862 MHz 26 27 29 950-2300 MHz 20 22 26 38 39 46 301-862 MHz 35 37 42 950-2300 MHz 28 37 39 12 (TV) 14 (TV) 12 (TV) UDL-215 UDL-400 Series. 4-way Tap-offs MODEL UDL-410 REF. 3235 3236 3237 Tap loss (± 1 ) 10 15 20 Tap-to-tap isolation Dimensions (mm): 76x58x26 4.0 1.9 0.9 950-1550 MHz 4.4 2.8 1.5 1551-2300 MHz 4.6 3.5 2.1 35 30 37 301-862 MHz 33 30 33 950-2300 MHz 29 23 25 29 30 29 301-862 MHz 26 28 26 950-2300 MHz 24 28 24 10 (TV) 10 (TV) 12 (TV) 112
UDL-800 Series. 8-way Tap-offs 10 MODELO UDL-816 UDL-820 REF. 3366 3367 Tap loss (± 1 ) 16 20 Tap-to-tap islolation 4.0 1.8 950-1550 MHz 4.4 2.0 1551-2300 MHz 4.8 2.2 30 30 301-862 MHz 30 30 950-2300 MHz 27 23 34 30 301-862 MHz 32 28 950-2300 MHz 25 28 10 (TV) UDL-816 Dimensions (mm): 120x60x20 UDL-410 UDL-410 Telefonía Registro Operador CATV 113
For use in single-cable tree distributions and for single systems or star distributions. Sturdy injection-moulded zinc alloy housing. Flush mounting in box Ø56 mm. Dimensions of coverplate: 80x80 mm. Fast and easy connection of the coaxial cable. Surface mounting using the ABT-210 (Ref. 1460). Versions without coverplate available. Connectors: TV: male IEC RD: female IEC TV-RD Line Outlets MODEL ARTU201 ARTU251 REF. 2750 2763 Coverplate YES NO Frequency range MHz 5-862 input - TV 7.5 (±0.5 ) input - RD 27.5 Max through loss 2.5 output - TV > 26 Isolation output - RD > 44 TV-RD isolation > 20 TV-RD Stub Outlets MODEL ARTU001 ARTU051 ARTU002 ARTU000 ARTU050 REF. 2736 2766 2737 2735 2734 Coverplate YES NO YES YES NO Technology Resistive LC filters Bridged Frequency range MHz 5-862 TV: 5-68 and 118-1000 RD: 87.5-108 5-862 input - TV 3.5 1 input - RD 10 3 TV-RD isolation > 12.5 > 10 The ARTU001 and ARTU051 models may be also used respectively as final outlets for a cascade of ARTU201 or ARTU251 outlets. 114
For use in single-cable tree distributions and for single systems or star distributions. Sturdy injection-moulded zinc alloy housing. Flush mounting in box Ø56 mm. Dimensions of coverplate: 80 x 80 mm. Fast and easy connection of the coaxial cable. Surface mounting using the ABT-210 (Ref. 1460). Versions without coverplate or fixing hooks available. Connectors: TV/RD: male IEC SAT: female IEC DC transit through the SAT output (24V/350mA, plus 22 khz and DiSEqC signals). Easy elimination. TV/RD-SAT Line Outlets MODEL ARTU900 ARTU901 ARTU951 ARTU902 ARTU903 REF. 2474 2475 2479 2476 2477 Coverplate and fixing hooks YES YES NO YES YES Frequency range (±0.5 ) Max through loss MHz TV/RD: 5-862 SAT: 950-2300 input - TV/RD 4.5 11 15 19 input - SAT 5.5 11 15 18 2 1.3 1.3 950-2300 MHz 3 2.5 2.5 output - TV/RD > 23 > 26 > 25 Isolation output - SAT > 16 > 17 > 19 TV/RD - SAT isolation > 25 > 25 > 25 > 25 DC transit through the SAT output YES YES YES YES ARTU900 and ARTU950 are final outlets. 10 TV/RD-SAT Stub Outlets MODEL ARTU009 ARTU058 ARTU059 REF. 2472 2740 2473 Coverplate and fixing hooks YES NO NO Frequency range MHz TV/RD: 5-862 SAT: 950-2300 input - TV/RD 1.5 input - SAT 2 TV/RD - SAT isolation > 25 DC transit through the SAT output YES YES NO Coverplate MODEL REF. DESCRIPTION PBT-200 2469 Coverplate for ARTU95x and ARTU059. Dimensions: 80x80 mm. Surface Mounting Frame MODEL REF. DESCRIPTION ABT-210 1460 Mounting of the outlets without embedding the body in the wall. 115
NEW! TV-RD-SAT. 3 outputs Outlets For use in single-cable tree distributions and for single system or star distribution. Sturdly injection-moulded zinc a Ø 56 mm. Convenient and fast connection of coaxial cable. It incorporates a socket for wall mounting. Coverplate (80 x 80 mm) including. Connectors type, TV: IEC male; RD: IEC female; SAT: F female. DC transit through the SAT output (24V/350mA, plus 22 khz and DiSEqC signals). MODEL PSE-300 PSE-301 REF. 5360 5359 Frequency range MHz TV : 5-68 and 125-862 RD : 88-108 SAT : 950-2300 input - TV 2 13 input - RD 2 13 input - SAT 3 14 5-68 MHz & 12 2 Max. through loss 88-108 MHz 2 950-2300 MHz 3 TV-RD and TV-SAT isolation > 18 SAT-RD isolation > 18 DC transit through the SAT output YES Application example PSE-300 SAT TV R Final Outlet PSE-301 SAT Surface Mounting Frame including TV R Line Outlet PSE-300 PSE-301 116