Farnsworth F100 Hue Test Instructions

Similar documents
ROY G BIV COLOR VISION EXPLORED

Everything You Wanted to Know About Color Vision

User s Manual Color Vision Recorder version 4

620 Rejwrts Investigative Ophthalmology

Historically, the development of colour vision tests

M. Marechal, M. Delbarre, J. Tesson, C. Lacambre, F. Froussart-Maille Percy Military Hospital, Clamart, FRANCE

VISUAL MILL LAB. SECTION 1: Complete the following tests and fill out the appropriate sections on your Visual Mill Color Deficit Worksheet.

Go! Guide: The Notes Tab in the EHR

Most advanced, portable, high-power 532nm Diode-Pumped Solid-State Photocoagulator

Scotchal Translucent Graphic Film Series 2630

INSTRUCTION BOOK FOR. Fast-Fold NXT

INSTRUCTION BOOK FOR. Deluxe Insta-Theater

This set of slides were used by Professor Cole in his talk on the occasion of the 60th anniversary of CIE Australia.

Automatic Testing of Color Blindness

LED Display Product Data Sheet LTP-1557TBE Spec No.: DS Effective Date: 06/16/2010 LITE-ON DCC RELEASE

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

UNDERSTANDING TINNITUS AND TINNITUS TREATMENTS

Standard Operating Procedure of nanoir2-s

PSM-003. Micro Polarization Controller/Scrambler. User Guide

LED Display Product Data Sheet LTS-4817SW-P Spec No.: DS Effective Date: 10/04/2011 LITE-ON DCC RELEASE

Kindly refer to Appendix A (Author s Checklist) and Appendix B (Template of the Paper) for more details/further information.

MICROPLATE LUMINOMETER. Operating Manual. Dated: 3/7/2002 Version: C Part Number:

ZX-44XL Liquid Fuel Analyzer. User s Manual Version 1.2

Library and Information Science (079) Marking Scheme ( )

QUICK REFERENCE GUIDE TO ENDNOTE Raymond Chong, PhD. January 10,

WCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12)

LED Display Product Data Sheet LTC-5623SW Spec No.: DS Effective Date: 04/11/2013 LITE-ON DCC RELEASE

Through Hole Lamp Product Data Sheet LTW-2S3D7 Spec No.: DS Effective Date: 10/06/2012 LITE-ON DCC RELEASE

LED Display Product Data Sheet LTS-2306CKD-P Spec No.: DS Effective Date: 07/20/2013 LITE-ON DCC RELEASE

Cie L*55 a* b* Keeping Color in Fashion. Solutions for textile color consistency

D-901 PC SOFTWARE Version 3

Estimation of inter-rater reliability

Cover Page for Lab Report Group Portion. Boundary Layer Measurements

FOR MEDIA SAMPLING INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

A Modified Protocol for Color Vision Screening Using Ishihara

UNIVERSITY OF MASSACHUSETTS Department of Biostatistics and Epidemiology BioEpi 540W - Introduction to Biostatistics Fall 2002

Approved by Principal Investigator Date: Approved by Super User: Date:

SIDRA INTERSECTION 8.0 UPDATE HISTORY

Using Endnote advanced features

JOURNAL OF PHARMACEUTICAL RESEARCH AND EDUCATION AUTHOR GUIDELINES

NIHR Southampton Biomedical Research Centre

American Chemical Society Publication Guidelines

COLOUR CHANGING USB LAMP KIT

Do the near computerised and non-computerised crowded Kay picture tests produce the same measure of visual acuity?

Please take a few minutes to read this manual so that you will better understand the featues and capabilities of your MF80. MF80 Owner s Manual 1

USER MANUAL Version 1.5.2

ALTOS LITE Loose Tube, Gel-Free Cables with FastAccess Technology, Fibers

INSTRUCTIONS TO THE AUTHORS FOR PUBLICATION IN BJ KINES-NATIONAL JOURNAL OF BASIC & APPLIED SCIENCE

Through Hole Lamp Product Data Sheet LTW-42NDP4-HF Spec No.: DS Effective Date: 08/23/2011 LITE-ON DCC RELEASE

common available Go to the provided as Word Files Only Use off. Length Generally for a book comprised a. Include book

CABLE TESTER User Manual

ANNALS OF OTOLOGY, RHINOLOGY & LARYNGOLOGY

CardioChek TM Analyzer

Baylor College of Medicine The Graduate School of Biomedical Sciences

Astigmatic axis and amblyopia in childhood

INTERNATIONAL STANDARD

Real-time ph and Conductivity Data Acquisition with the ACQUITY UPLC H-Class Bio System, Auto Blend Plus, and the GE Healthcare Monitor ph/c-900

Water blocking tape. Locator ridge HPA-0486

STAT 113: Statistics and Society Ellen Gundlach, Purdue University. (Chapters refer to Moore and Notz, Statistics: Concepts and Controversies, 8e)

User s ManUal NON-CONTACT TACHOMETER. Please read this manual carefully and thoroughly before using this product.

Metal Electrode Meter

Cie L*48.57 a* b* Covering the World. Solutions for paint and coatings color management

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Features. Applications. Part Number Color Package Description

ABSTRACT SUBMISSION GUIDELINES 2018 Oral or Poster Communications

HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA

Creative Suggestions & Billboard Installation

The Diagnosis of Small Solitary Pulmonary Nodule:

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

Visiolite Master PC-based Virusscreener

The Washington Manual Of Medical Therapeutics, Print + Online PDF

Instructions to authors

Koester Performance Research Koester Performance Research Heidi Koester, Ph.D. Rich Simpson, Ph.D., ATP

Course Outline Cover Page

PROGRAMMING GUIDE. Accurate Targeting. Precise Control.

Peer Review Process in Medical Journals

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

Asian Journal of Occupational Therapy Author s Guide

Part III: How to Present in the Health Sciences

VT VGA TFT NEMA 4/12 Flat Panel Monitor. User s Guide

SE-SMD0603-PW65 SMD 0603 purweiss, wasserklar

SCRIPT INNOVATIONS INC. C- RAY PILL COUNTER OPERATORS MANUAL

INSTRUCTIONS TO CONTRIBUTORS

RULES AND REGULATIONS FOR THE NCSRT, INC. SCIENTIFIC PAPERS

Flat-Bed Module Recorders

Operating Instructions

Installation Guide. Table of Contents: HotLok Full Rack Blanking Panel Kit. Mounting Extrusion. HotLok Blanking Panel. HotLok Blanking Sheet

NAA ENHANCING THE QUALITY OF MARKING PROJECT: THE EFFECT OF SAMPLE SIZE ON INCREASED PRECISION IN DETECTING ERRANT MARKING

MONO AMPLIFIER KIT ESSENTIAL INFORMATION. Version 2.2 CREATE YOUR OWN SPEAKER DOCK WITH THIS

Common Spatial Patterns 2 class BCI V Copyright 2012 g.tec medical engineering GmbH

Siemens Industry Online Support

TC3301. User's Manual

MedicaLight SURGICAL AND EXAMINATION LIGHTING

HBI Database. Version 2 (User Manual)

HEARING SOLUTIONS JAN 2013 MONTHLY MEETING TINNITUS PRESENTED BY DR KUPPERMAN

Korean Journal of Ophthalmology Instructions for Authors

ISS New Audio & Visual installations Design and Physical install guidelines v1.5

TC3005(LED/ELED/LASER) User's Manual

LCD Colour Analyser, PM 5639/06, handheld LCD Colour Analyser, PM 5639/26, industrial LCD Colour Sensor, PM 5639/94

Simulation Lab MediaSite Training Workshop

Transcription:

Introduction Farnsworth F100 Hue Tests For Congenital and Acquired Color Vision Defects - Color Discs, developed in the 1940 s The Farnsworth-Munsell 100 Hue Test examines hue discrimination ability and is intended for use in vocational and diagnostic applications. The Farnsworth 100 Hue test has been shown to be useful in classifying those with normal color vision into aboveaverage, average and poor hue discrimination. Research studies have recommended that practitioners administer a battery of color vision tests to identify people with color vision defects rather than rely exclusively on the Farnsworth 100 Hue test. However, the Farnsworth 100 Hue test remains the most comprehensive color vision test. The test result is based on a total error score. Using the Farnsworth 100 Score Template available for download on good-lite. com, the patient s arrangement of the 100 Hue discs is entered and errors are scored. Hue discrimination ability is estimated from the total error score and the type of color deficiency is determined from the graphical representation of the results. Characteristic 100 Hue plots for congenital protan, deutan and tritan defects show concentrations of errors in well-defined positions nearly opposite in the polar diagram representing the circle of hues. Results can be graphed using other methods, which are described in various scholastic research papers referenced at the end of this manuel. Contents Each Good-Lite Farnsworth 100 Hue Test set consists of: 93 colored discs arranged in four rows (numbered on the bottom) Four (4) Clear ABS Cases (with tops) 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 Note: The first two discs of each case are duplicated from the previous case. Storage The Farnsworth 100 Hue test should be stored in a cool dry place. The set should be kept wrapped in the shipping container or other enclosure to protect from light as exposure to light will affect the color discs Precautions Each color disc is mounted without any protection of the color sample to insure correlation to other color tests. Consequently, it is very important to insure that no one touches the color sample to avoid the damage of fingerprints. This is the reason that it is very important that the examiner and the patient wear some sort of protection of the fingertips. Individual color discs that become dis-colored or smudged can be replaced as needed. See the section entitled Replacement Parts below. Test Environment Lighting The test is intended to be administered on a black background to prevent surroundings from affecting the color perception by the patient. Further, it is very important to administer these tests under consistent conditions so that each subsequent retest over time can be judged properly. The illumination should provide approximately 6280 Kelvin at 25 foot-candles or greater (Illuminant C) or daylight. Good-Lite s Color Test Daylight Illuminator (612600) provides the recommended illumination and a flat tray directly under the light for optimum illumination. ABS Black Plastic Tray with Lid to hold the Four Cases Farnsworth F100 Test Instructions 100 Hue Score Sheet (laminated) The four cases include the following color discs: Case 1 = 24 discs 84 85 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Case 2 = 23 discs 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 Case 3 = 23 discs 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 The Good-Lite Color Test Daylight Illuminator (612600) comes with Universal Power Supply adapting to any combination of 50 or 60 Hz and 110 or 220 volt Case 4 =23 discs www.good-lite.com 1.800.362.3860 1.888.362.2576 fax 1

Pre-test Considerations The examiner must determine if the test will be accomplished using binocular vision or separately for each eye. Past history of trauma, disease or potential toxicity are acquired defects that warrant monocular testing. Testing for congenital color defects is usually accomplished binocularly because monocular variations of congenital defects are rare. The score sheet should be marked according to whether the test was monocular or binocular. The examiner should also determine the approximate amount of time the patient will be permitted for the test. Children over the age of 5 often can perform the test adequately. For patients with limited dexterity, the procedure indicated where each color disc selection is placed in the corral may be altered with the patient requested to indicate each selection for line-up by the examiner. It is important that the patient be able to view the lineup as it builds for review. The Farnsworth F100 Hue test is not effected by mild to moderate visual acuity loss. The test is engineered to be conducted at a working distance of 19.5 inches (50 cm). For low vision patients, an abbreviated test, the Farnsworth D-15 Color Test, comes with color discs that are increase by almost three times in size, is available from Good-Lite (730022). Testing Procedure The test procedure that follows is to be used in conjunction with the Farnsworth 100 Score Template available on good-lite.com for Scoring. If using this scoring method one duplicated disc from each case must be re- moved. From Case 1 remove number 22, Case 2 remove number 43, Case 3 remove number 64 and Case 4 Remove number 85. Save these removed discs as other scoring methods my require use of these duplicated discs. Start with Case Number 1. Remove the sliding top to one of the Plexiglas Cases, tip one end of the case and carefully slide all of the color discs onto a black surface. The examiner then selects the first reference disc (# 84 in Case 1) and places the disc into the appropriate Plexiglas Case to the end. The examiner then mixes up the remaining discs(color side up) before beginning the test. The patient is then instructed to select the color disc from those remaining which most closely matches the reference cap and slide it into the Plexiglas Case next to the reference cap. The patient then continues to select the next closest color disc and places each in sequence in the Plexiglas Case. The patient should be given a reasonable time to arrange the discs and may be permitted to alter the sequence prior to completion. However, the time should be about 2 minutes per case and should not be unlimited. At the completion of the test for Case 1, the examiner should slide the lid into place to secure the test discs. To open the ABS clear plastic box, press the circular label in the center of the top and lift up one end. Keeping the top and bottom together (but still open) tip the color discs into the top so they are upside down. Now tip the top (with the discs) onto the surface selected for the test. It is recommended that the surface be black in color. The examiner then selects the reference cap (# 84 in Case 1) and places that cap into the box bottom, to one end. Wearing gloves, the patient is then instructed to select the color disc, which most closely matches the reference cap and place in the bottom of the box and slide next to the reference cap. The patient then continues to select the next closest color disc and places each in sequence in the bottom of the box. The patient should be given a reasonable time to arrange the discs and may be permitted to alter the sequence prior to completion, however, the time should be about 2 1/2 minutes and should not be unlimited. At the completion of the test, the examiner should slide the lid into place to secure the test chips. The test is then repeated for each of the other three cases. Scoring Scoring for each case is accomplished by reading the color chip numbers on the reverse side of the case through the clear ABS box and recording the sequence selected by the patient on a copy of the score sheet. Attachment 1 shows a reduced sample of the Good-Lite Farnsworth 100 Hue Score Template. Note: The last disc of each case is repeated as one of the reference discs in the next case, but is not rescored. To determine a score and obtain a graphic representation of the outcomes, you may choose to use the Farnsworth 100 Score Template available on good-lite.com which is enclosed. Farnsworth 100 Score Template The Farnsworth 100 MS-Excel Scoring template found on our website is used to build an analysis of the scores for each patient. 1. Download file from web under P/N 730024 2. Create Patient File: From the Explore application, create a folder with the patient s name (such as DoeJohn02). From Excel, go to File, then Save as then use the dialog box to find the patient s folder. In the Save as dialog box, change the Save as type to Microsoft Excel Workbook. Note: Changing the file type to Microsoft Excel Workbook is a very important step to insure that the patients results are uniquely saved under that patient s name. Complete the Save as process giving the file the name of the patient and date (or whatever convention you have chosen. For example, use DoeJohn092102 as the file name in the folder entitled DoeJohn02 ). www.good-lite.com 1.800.362.3860 1.888.362.2576 fax 2

3. Enter the Patient s Name and Scores Back in the Excel application, click on the cell with the words Enter Name Here and type over this entry the actual name of the patient. Repeat this for the cells entitled Enter Date of Exam and Enter Tester s Name. Now, from the handwritten score sheet or the actual cases, enter the Actual Disc selection by the patient in the appropriate cell (likely cell C8). Enter the other selections in the column titled Actual Disc. Note: From the beginning, the column titled Error Score will have entries. As the Actual Disc selections are entered, Excel will automatically calculate the correct Error Score and place that result in the proper column. 4. Save the Patient s Scores: At the completion of the patient s selection entries, go to File, and then Save to insure that the entries have been archived. Replacement and Optional Parts P/N Description 443300 Replacement Color Discs (Specify Farnsworth 100 Hue Case number and disc number) 443600 Laminated Farnsworth 100 Hue scoring card (8 1 2 by 11 or 22 cm by 28 cm) 477900 Clear ABS Plastic Replacement Case for 24 Discs for Farnsworth 100 Hue set 478000 Black Plastic Tray with Lid to hold 4 P/N 477900 Cases for Farnsworth 100 Hue 481900 Pad of 100 score sheets (1 lb) for use instead of the Laminated Score Card for US$ 23.00 each 5. Printing the Patient s Results: Across the bottom of the Excel window, click on the tab entitled Patient Report. Review for Patients name and other pertinent data, then print. This page shows the Patient s name, test data, disc selections, line by line calculated scores and the total score. Now, across the bottom of the Excel window, click on the tab entitled Print Chart. Review for Patients name and other pertinent data, then print. This page shows the patient s name, and a graphic charting of the patient s scores with the Protan, Deutan and Tritan lines pre-marked. Interpretation of Results Interpretation of the error scores and graphic charting of the patient s scores is left to the physician. The appendix provides a list of textbooks and other materials, which can be used to develop a method of interpretation. Retesting As opposed to the D-15 test, which is a much shorter test to administer, retesting with the Farnsworth 100-hue test in the same session often yields somewhat different scores and is not deemed reliable. Interpretation of Scores Consultation of a textbook on this subject is suggested. www.good-lite.com 1.800.362.3860 1.888.362.2576 fax 3

F 100 Hue References: 1. Aspinall, P A (1974) Inter-eye comparison and the 100 hue test. Acta Ophthalmologica, 52, 307-16. 2. Birch, J (1993) Diagnosis of Defective Colour Vision. Oxford Medical Publications. 3. Dain, S J and Birch, J (1987) An averaging method for the interpretation of the Farnsworth-Munsell 100 hue test. British Journal of Physiological Optics, 7, 3, 267-80. 4. Farnsworth, D (1943) The Farnsworth Munsell 100-Hue and dichotomous tests for colour vision Journal Ophthalmology Society American 33:568-78. 5. Farnsworth D, An Introduction to the Principles of Color Deficiency Report No 254, Medical Research Laboratory, 8 Sept 1954. 6. Fukami, K. Evaluation of the Farnsworth-Munsell 100-Hue Test Japanese Journal of Clinical Ophthalmology 30:27-31, 1976. 7. Greenstein V, Sarter B, Noble K, and Carr R. Investigative Ophthalmology & Visual Science Vol. 31, 1008-1014. Hue discrimination and S cone pathway sensitivity in early diabetic retinopathy. 8. Hahn C, Evaluation of Hahn Double 15 Hue Test Poster Session 10th Japan-Korea Joint Meeting of Ophthalmology 9/21-23/2000. 9. Helve, J. A comparative study of several diagnostic tests of colour vision used for measuring types and degrees of congenital red-green defects. Acta Ophthalmology Supplement. 115:18, 1972. 10. Malone D, and Hannay H J. The Farnsworth-Munsell 100- Hue Test: A Question of Norms, Auburn University Perception and Motor Skills, 1977, 44, 1249-1250. 11. Nickerson D, Granville W. Hue Sensibility to Dominant Wavelength Change, Journal Opt. Soc Am 30, 159 (1940). 12. Smith VC, Pokorny J. Large-field trichromacy in protanopes and deuteranopes Journal Opt Soc Am 1977; 67:213-220. 13. Tasman W, Jaeger E.A. Duane s Clinical Ophthalmology, Vol 3, Chapter 6, Lippincott Williams & Wilkins, 2000. 14. Verriest G, van Laethem J, Uvijel A. A new assessment of the normal ranges of the Farnsworth-Munsell 100 hue test scores American Journal of Ophthalmology 1982; 93:635-642. 15. Vingrys AJ and King-Smith PE Investigative Ophthalmology & Visual Science Vol. 29, 50-53 A quantitative scoring technique for panel tests of color vision. Plaquenil Testing References: 1. Bernstein HN. Ophthalmic considerations and testing patients receiving long-term antimalarial therapy. AM J Med 1983;75(18):25-34. 2. Muirden KD. The use of chloroquine and D-penicillamine in the treatment of rheumatoid arthritis. Med J Aus 1986;144(1)32-7. 3. Cullen AP, Chou BR. Keratopathy with low dose chloroquine therapy. J Am Optom Assoc 1986;5(5):368-72. 4. Meischer PA. Treatment of systemic lupus erythematosus. Springer Sem Immunopathol 1986;9:271-82. 5. Bartlett JD, Jaanus SD. Ocular effects of systemic drugs. In: Bartlett JD, Jaanus SD, eds Clinical Ocular Pharmacology, 2nd ed. Boston: Butterworths, 1989: 901-42. 6. Finbloom DS, Silver K, Newsome DA, Gunkel R. Comparison of hydroxychloroquine and chloroquine use and the development of retinal toxicity. J Rheumatol 1985;12(4):692-4. 7. Johnson MW, Vine AK. Hydroxychloroquine therapy in massive total doses without retinal toxicity. 1987;140:139-44. 8. The Medical Letter on Drugs and Therapeutics. 1987;29(734):21-4. 9. Rynes RL. Ophthalmologic safety of long-term hydroxychloroquine sulfate treatment. Am J Med 1983:75(18):35-8. 10. Kastrup EK, et al., eds. Facts and Comparisons. St Louis. Lippincott, 1986:253e-g. 11. Bowman KJ. A method for quantitative scoring of the Farnsworth Panel D-15. Acta Ophthalmologica (Copenh) 1982;60:907-16. 12. Bowman KJ, Collins MJ, Henry CJ. The effect of age on performance of the panel D-15 and de-saturated D-15: a quantitative evaluation. In: Verriest G, ed. Colour Vision Deficiencies, VII. The Hague: Dr W Junk Publishers, 1984:227-31. 13. Cyert L. Eye and Vision Conditions in the American Indian. Pueblo Publishing Goss and Edmonson 1990:137-147. Web References: NZHTA Report 7 - New Zealand Health Technology Assessment (NZHTA) The Clearing House for Health Outcomes and Health Technology Assessment Department of Public Health and General Practice Christchurch School of Medicine Christchurch, N.Z. Colour vision screening A http://nzhta.chmeds.ac.nz/colour. htm#screening http://orlab.optom.unsw.edu.au/icvs/daltoniana.april98.html 16. McIntyre, Donald Colour Blindness - Causes and Effects Dalton Publishing, 2002 www.good-lite.com 1.800.362.3860 1.888.362.2576 fax 4

Appendix A Sample Good-Lite Farnsworth 100 Hue Score Sheet Note: The last disc of each case is repeated in the next but is not scored. FARNSWORTH 100 HUE SCORE SHEET Good-Lite P/N 443600 Name: Date of exam: Tester: (Make acopy and usethe copy) Case 1 85=0 Case 2 Case 3 Case 4 Disc # Actual Disc # Disc # Actual Disc # Disc # Actual Disc # Disc # Actual Disc # 85 22 43 64 1 23 44 65 2 24 45 66 3 25 46 67 4 26 47 68 5 27 48 69 6 28 49 70 7 29 50 71 8 30 51 72 9 31 52 73 10 32 53 74 11 33 54 75 12 34 55 76 13 35 56 77 14 36 57 78 15 37 58 79 16 38 59 80 17 39 60 81 18 40 61 82 19 41 62 83 20 42 63 84 21 www.good-lite.com 1.800.362.3860 1.888.362.2576 fax 5