GYFTY TECHNICAL SPECIFICATIONS FOR GYFTY CABLE

Similar documents
Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

Micro duct Cable with HDPE Sheath for Installation by Blowing

TECHNICAL SPECIFICATION

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

Revision No. 4 Page No. Page 1 of 7

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Standard FTTH Drop Cable. FTTH DROP - nb6a1/g657a1

Number of Fiber 12 Core 24 Core 48 Core. Part Number

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS)

1. Scope OUTDOOR OFC-ADSS, SM(0.9) LOOSE TUBE BLACK

TENDER SUMMARY. Tender Title:

1. General. 1. Scope. 2. Quality Assurance

Number of Fiber 6 Core 12 Core. Part Number

Number of Fiber 6 Core 12 Core 24 Core 48 Core

FIBER OPTIC CABLES. Models GYXTC-8SS GJFJV

SPECIFICATION. Optical Fiber Cable

1. Scope OUTDOOR OFC-DW-(Twisted), SM (0.9) LOOSE TUBE BLACK

Detailed Specifications & Technical Data

LD Series High Performance Loose Tube Fiberoptic Cables

OPTICAL FIBRE CABLE NETWORK 2004/1

Ø 1000 * 588 mm 50 kg

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

Material Description Quantity UOM

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference

GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information.

ETSI ES V1.1.1 ( )

HERA RETICULATION FIBRE CABLE PRODUCT REQUIREMENTS

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

Mining and Petrochemical Fiber Optic Cables

FREEDM Loose Tube Interlocking Armored Cables

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

OPTICAL CABLE FIBER-LAN INDOOR

Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7

SOLO ADSS Short-Span Cables, Fibers

SPECIFICATION FOR FIBER OPTIC SPLICE CLOSURE

DOME OPTIC SPLICE CLOSURE

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

The BRU-SF10 supports single mode optical fiber cable ensuring 2,000m transmission at maximum.

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET

Sumitomo Cable Specification SE-*DB. 100% Dry - Armored Central Tube Ribbon Cable with Fibers. Issued: January 2014

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Non-metallic Aerial Distribution Optical Cables for FTTH Networks

Bharat Heavy Electricals Limited HIGH PRESSURE BOILER PLANT, TIRUCHIRAPPALLI CONTROLS AND INSTRUMENTATION/FB

Product Catalogue. Fibre Optic Cable

Empowering businesses through innovative network solutions.

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

How to Speak Fiber Geek Article 4: Single-Mode Optical Fiber Geometries

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Table of Contents. Open Matrix System (OMS) 1-2

SPECIFICATION. Spec No : VSS-1402-CS603B

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12)

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

TECHNICAL SPECIFICATION

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

FIBRE OPTIC CABLE SOLUTIONS

for FOSTEC INC. 1/ 15

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

Public Works Division Lighting District Fiber Optic Specifications April 2009

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

Content. 1.4 Fiber Cable Assembly

We design, build, and manage web-scale networks for the needs of tomorrow. System Integration SERVICES

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

Cables for robot applications

PRO SERIES FIBRE-150M

SECTION 4 TABLE OF CONTENTS

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

The advantages of using reduced coating diameter optical fibers (200µm) in ADSS cables for deployment in FTTx networks

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

Mar11 Rev E

The World Of Professional Fiber Optics. safe flexible reliable

PM Couplers (Polarization Maintaining Couplers)

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications

INDUSTRY SOLUTIONS: MINING

Assembly code page 46. Cable code page 47. Assembly classes page 48. Polarization maintaining assemblies page 52

Cable installation guidelines

Industry solutions: Broadcast

Linear encoders without bearings incremental System for linear motion feedback

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Fiber Optic Cable System

Specification DNA Tracking Resistant ADSS Cable AC024AP6821BD0

BendBright XS Single Mode Optical Fibre

Recommended Changes to Optical PMD Proposal

THE INFORMATION GATEWAY FIBRE OPTIC CABLES

ANSI/ICEA S STANDARD FOR OPTICAL FIBER OUTSIDE PLANT COMMUNICATIONS CABLE

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

The LGBF900 products are of high quality, dual window

Introduction to Fiber Optic Cable Technology Jerry Bednarczyk, PE Course Content

HI-DEX PRODUCT SET DATASHEET

Gear up for the future.

STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE. Publication S First Edition - June 2012

A IR-BL O W N SOLUTION C O D. M I C R O C O D. M I C R O D U C T

DIAS power supply and DIC 221 fibre optic cable coupling module

Transcription:

TECHNICAL SPECIFICATIONS FOR GYFTY CABLE 1

1. Product Description This specification covers the general requirements and performance of cable, which FOC offered including optical characteristics, mechanical characteristics and geometrical characteristics and etc. 2. OPTICAL FIBER Category Optical Optical fiber characteristics (FPC G.652D FIBER) Attenuation Attenuation discontinuity Description Attenuation vs. Wavelength Zero Dispersion Wavelength Zero Dispersion Slope Dispersion @1383nm @1625nm 1285~1330 1525~1575 G.652D 0.35dB/km 0.35dB/km 0.22dB/km 0.30dB/km 0.05 db 0.05 db/km 0.05 db/km 1300~1324nm 0.092ps/(nm 2.km) 3.5 ps/nm.km 18 ps/nm.km Polarization Mode Dispersion(PMD) 0.2ps/km 1/2 Cable Cutoff Wavelength(λcc) Effective Group Index of Refraction Mode Field Diameter 1260nm 1.4675 1.4681 9.2±0.6μm 10.4±0.8μm Geometric Cladding Diameter Cladding Non-Circularity Coating Diameter 125±1μm 1.0% 245±7μm Coating/Cladding Concentricity Error 8μm Core/Cladding Concentricity Error 0.8μm Mechanical Proof Test level Fiber Curl Radius Peak Coating Strip Force 1.0% 4.0m 1.3~8.9N 2

3. OPTICAL CABLE 3.1 Construction of cable Optical Fiber thixotropic Jelly Loose Tube non-metallic Central Strength Member (FRP) Jelly compound PE Outer sheath Structure Unit Parameter Fiber count Fibers 2~48 50~84 86~96 144 Max.Cores of per tube -- 6 12 12 12 Loose tube Diameter mm Nom.Ф1.8 Nom.Ф2.1 Nom.Ф2.1 Nom.Ф2.1 Element 8 7 8 12 Cable diameter mm Nom.10.2 Nom.10.8 Nom.11.6 Nom.14.3 sheath thickness mm Nom.2.0 Nom.2.0 Nom.2.0 Nom.2.0 Weight Kg/km Approx.94 Approx.117 Approx.129 Approx.194 Bending Radius Dynamic Static 25 Cable Diameter 15 Cable Diameter Operating Temperature -40 --- +60 4.2 Fiber coding,the color coding of the optical fiber shall be in accordance with Table 4.2.1 No. of fiber 1 2 3 4 5 6 Color of fiber Blue Orange Green Brown Grey White No. of fiber 7 8 9 10 11 12 Color of fiber Red Black Yellow Violet Pink Aqua Table4.2.2:Identification of optical tube No. of tube 1 2 3 4 5 6 Color of tube Blue Orange Green Brown Grey White No. of tube 7 8 9 10 11 12 Color of tube Red Black Yellow Violet Pink Aqua 3

Table4.2.3:Make-up of cable, No. of Fibers in each Tube No.of No.of Fibers Tube 1 2 3 4 5 6 7 8 9 10 11 12 4 1 Tube color Blue No. of fiber 4 F F F F F F F 8 2 Tube color Blue Orange No. of fiber 4 4 F F F F F F 12 2 Tube color Blue Orange No. of fiber 6 6 F F F F F F 24 4 Tube color Blue Orange Green Brown No. of fiber 6 6 6 6 F F F F 32 6 Tube color Blue Orange Green Brown Grey White No. of fiber 6 6 6 6 6 2 F F 48 8 64 6 Tube color Blue Orange Green Brown Grey White Red Black No. of fiber 6 6 6 6 6 6 6 6 Tube color Blue Orange Green Brown Grey White F No. of fiber 12 12 12 12 12 4 96 8 Tube color Blue Orange Green Brown Grey White Red Black No. of fiber 12 12 12 12 12 12 12 12 144 12 Tube color Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua No. of fiber 12 12 12 12 12 12 12 12 12 12 12 12 Note: F means the white filler 4. TEST REQUIREMENTS No Item Test standard Method Acceptance criteria 1 Tensile IEC-60794-1-E1 -Max. Tensile strength:1500n -Sample length:50 meters -Time: 1minutes; -Fiber strain at maximum Load: max. 0.33% increase 0.10dB 2 Crush IEC-60794-1-E3 -Load:1000N -Time: 1 minutes -Length: 100mm -No splits or cracks in the ; increase<0.10db, 3 Impact IEC-60794-1-E4 -Impact energy: 450g - Height:1 meter -Impact points: min.1 --Number of impacts: 5 -No splits or cracks in the increase 0.10dB(After the ) 4 Repeated bending IEC-60794-1-E6 -R=20 cable outer diameter -1m cable length with 150N weight,30 cycles increase 4

5 Torsion IEC-60794-1-E7 6 Bending IEC-60794-1-E11 7 Temperature cycling IEC-60794-1-F1 Water 8 penetration IEC-60794-1-F5 9 Drip IEC-60794-1-E14-1m cable length with 150N weight -±180 degrees, 10 cycles -Diameter of mandrel: 20 D -Number of turns/helix:10 -Number of cycles: 5 -Temperature step: +20-40 +60-40 +60 +20 -Time per each step: 12 hrs -Number of cycles: 2 cycles -Water height: 1m -Sample length:3m -Duration of : 24hrs -Five 0.3m samples suspended vertically in a climate chamber, raised temperature to +70 0.10dB(After the ) increase 0.10B(After the ) - No fiber break variation for reference value(the attenuation to be measured before at +20±3 ) 0.10dB/km, -No water leakage at the end of the sample -No filling compound shall drip from tubes after 24 hr 5. PACKING AND DRUM 5.1 The cable is wound on a non-returnable wooden drum. Both ends of cable are securely fastened to drum and sealed with a shrinkable cap to prevent ingress of moisture. The following information shall be marked on the outer sheath of the cable at an interval of about 1 meter. - Cable type and number of optical fiber - Manufacturer name - Month and Year of Manufacture - Cable length The sequential number of the cable length shall be marked on the outer sheath of the cable at an interval of 1meter ± 1%. 5.2 Drum marking, Each side of every wooden drum shall be permanently marked in a minimum of 2.5~3 cm high lettering with following: - Manufacture name and logo - Cable length - Cable type and number of fibers - Roll way - Gross and net weight -End of Specification- 5