PERFORMANCE SPECIFICATION SHEET CIRCUIT BREAKERS, MAGNETIC, LOW-POWER, SEALED, TRIP-FREE THREE-POLE, AUXILIARY CONTACTS

Similar documents
INCH-POUND MIL-PRF-55629/21G 10 March 2010 SUPERSEDING MIL-PRF-55629/21F 21 September 2005 PERFORMANCE SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET CONNECTORS, RECEPTACLE, ELECTRICAL, SOLDER OR WELDED FLANGE MOUNT, BAYONET COUPLING, SOLDER PIN CONTACT, CLASS H, SERIES 2

DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, CIRCULAR, RECEPTACLE, THREADED, JAM-NUT MOUNTING, REMOVABLE CRIMP CONTACTS, SERIES III, METRIC

PERFORMANCE SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, CIRCULAR, RECEPTACLE, THREADED, JAM-NUT MOUNTING, REMOVABLE CRIMP CONTACTS, SERIES III, METRIC

DETAIL SPECIFICATION SHEET CONNECTORS, PLUG, ELECTRICAL, RFI SHIELDED, SERIES 2, CRIMP TYPE, BAYONET COUPLING, CLASSES A, D, L, T, W AND K

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL, RADIO FREQUENCY (SERIES SMA (CABLED) - PLUG, PIN CONTACT, CLASS 2)

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL RADIO FREQUENCY, (SERIES TNC (CABLED), PIN CONTACT, RIGHT ANGLE, CLASS 2)

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL RADIO FREQUENCY, (SERIES BNC (CABLED), PIN CONTACT, CLASS 2)

INCH-POUND MIL-PRF-39012/29H w/amendment 3 25 January 2018 SUPERSEDING MIL-PRF-39012/29H w/amendment 2 21 November 2016

INCH-POUND MIL-PRF-39012/28H w/amendment 4 25 January 2018 SUPERSEDING MIL-PRF-39012/28H w/amendment 3 15 April 2017

MILLITARY SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, CIRCULAR, RECEPTACLE, THREADED, DUMMY STOWAGE, SERIES III, METRIC

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL RADIO FREQUENCY, (SERIES BNC (CABLED), PIN CONTACT, CLASS 2)

MILITARY SPECIFICATION SHEET

The requirements for acquiring the product described herein shall consist of this specification sheet and FF-N-836.

Magnetic and Hydraulic-Magnetic Circuit Breaker

Pendant Light Fitting IEC Series 6470/2

Series CDP2 Definite Purpose Contactors

PERFORMANCE SPECIFICATION SHEET

Series CDP2 Definite Purpose Contactors

For Sales & Information, Call Toll Free: (888)

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, CATHODE RAY TYPE 7AGP19

bmam connectors DIVIDER PAGE

GR circuit breaker - hydraulic magnetic, Datasheet

PERFORMANCE SPECIFICATION SHEET SWITCHES, PUSHBUTTON, ULTRA-COMPACT, LED ILLUMINATION, NVIS, SEALED

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

GR circuit breaker - hydraulic magnetic, Datasheet

HDRFI Series Tensolite High-Performance Cable & Interconnect Systems. High Density RF Interconnect

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

SMA One Piece Semi-Rigid Connectors

DEPARTMENT OF DEFENSE STANDARD PRACTICE

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71.

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

Panel-mounting thermostats, type series EM

3 Cleaning. 4 Technical data

Single Point Flow Monitor SW118 SW119

SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION

Selection matrix for electronic pressure switches

Bimetal Temperature Switch

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Panel-Mounted Thermostat

TE Connectivity DEUTSCH DL Series MIL-DTL Series III Connectors

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

ATC 600S Series Ultra-Low ESR, High Q, NPO RF & Microwave Capacitors

Definite Purpose Contactors

MCX - 75 Ohm Connectors

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Type "N" Connectors. Type "N" Interface Dimensions

ATC 600S Series Ultra-Low ESR, High Q, NPO RF & Microwave Capacitors

LW Series offer flexibility in space-saving package

Model Number Structure

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Parameter Input Output Min Typ Max Diode Option (GHz) (GHz) Input drive level (dbm)

Site Installation Model MP-8433

Magnecraft Power Relays

Distributed Design Series

WLC60 Heavy Duty LED Light - PWM Dimmable

PERFORMANCE SPECIFICATION SHEET

SPECIAL SPECIFICATION 2344 TMC Support Equipment

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

MICROLITHIC DOUBLE-BALANCED I/Q MIXER


Sensor technologies Proximity sensors Series ST4. Brochure

GaAs MMIC Double Balanced Mixer

AMERICAN NATIONAL STANDARD

P2-HSI High-Speed Isolated Sinking/Sourcing Input. Connector Specifications

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

MS2540 Current Loop Receiver with RS485 Communication

Solid-State Digital Timer

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

Kulka Military Class (A-A-59125) / (MIL-T-55164*)

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

Installation Instructions for SBII 800 MHz Filter Conversion Kit Part# 89-89A /5/10/15/18/10-18/15-18

GaAs MMIC Double Balanced Mixer

Ultra-Grip 2 Crimp Connector Hand Tool Kit for Coaxial Cable Connectors, Powerpole Connectors, Insulated and Non-Insulated Crimp Terminals

Site Installation Model MP-8424

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Kuhnke Technical Data. Contact Details

Non Magnetic Connectors

I1000M Rough-In Instructions

Ribbon Cable connector Compliant with MIL Standard

Ribbon Cable connector Compliant with MIL Standard

AC1036. Definite Purpose Contactors

Ribbon Cable connector Compliant with MIL Standard

Transcription:

INH-POUND MIL-PRF-39019/6H 14 May 0 SUPERSEDING MIL-PRF-39019/6G 27 ugust 1997 PERFORMNE SPEIFITION SHEET IRUIT REKERS, MGNETI, LOW-POWER, SELED, TRIP-FREE THREE-POLE, UXILIRY ONTTS This specification is approved for use by all Departments and gencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-39019. (SEE NOTE 11) (SEE NOTE 13) 3 UXILRY ONTT TERMINLS (SEE NOTE 14) NO N FIGURE 1. ircuit breaker configuration. MS N/ FS 5925

FIGURE 1. ircuit breaker configuration - ontinued. 2

Inches mm Inches mm Inches mm Inches mm Inches mm.005 0.13.125 3.18.325 8.26.392 9.96.687 17.45.015 0.38.138 3.51.332 8.43.493 12.906 23.01.030 0.76.140 3.56.375 9.52.507 12.88 62 39.67.060 2.188 4.78.380 9.65.610 15.49 1.828 46.43.062 7.240 6.10.382 9.70.625 15.88 1.937 49.20.063 1.60.250 6.35.391 9.93.641 16.28 1.950 49.53 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is ±.031 (0.79 mm). 4. The shape of the circuit breaker is shown for information only. Slight deviations from this outline drawing, which do not alter the functional aspect of the device, are acceptable. 5. Hex mounting nut.375-32 UNEF-2 thread,.093 ±.005 (2.36 ±0.13 mm) thick or equivalent MS25082-20, -20. 6. Internal tooth lockwasher,.507/.493 O.D.,.392/.382 I.D.,.025 ±.005 (0.64 ±0.13mm) thick, stainless steel or equivalent MS35333-134. 7. The effective bushing thread length (not including mounting hardware) is.280 (7.11 mm) minimum. 8. Marking may appear on any surface except the mounting surface. 9. Lock ring not required if on-off plate has locking tab. 10. Numerical marking optional on circuit diagram. 11. Sealscrew,.138-32 UN-2 x.312 (7.92 mm) long, stainless steel number 18-8 (type 347) MS35265-25 or equivalent with appropriate O-rings. O-rings should be chosen to enable the circuit breaker to meet the performance requirements of this specification. Possible source: MP Hexseal orporation. 12. Use of panel screws will enhance circuit breaker shock and vibration characteristics. 13. Threaded inserts exceed height of bushing by.005 to.015 (0.13 mm to 0.38 mm). 14. uxiliary contact terminals shall be located on the back side of the circuit breaker (same surface as main terminals), but otherwise their location, style, and form shall be optional, consistent with dimensional or other specified requirements. uxiliary contact terminals shall accommodate two number 20 WG wires. 15. For configuration 2 add "S" at end of dash number for screw terminals with insulating block (see table I). When circuit breakers are subjected to the resistance to solvents test, the insulating block shall be removed and shall not be tested. Main terminal screw MS35265-26 or equivalent. FIGURE 1. ircuit breaker configuration - ontinued. 3

REQUIREMENTS: Dimensions and configuration: See figure 1 and note 15. Weight: For reference only, approximately 150 grams. Mounting hardware: See figure 1. Terminals: See figure 1. Voltage and frequency rating: 50 V dc, maximum and 240 V ac, maximum at 60 Hz and 400 Hz. High inrush: 800 percent at 60 Hz and dc, 1,400 percent at 400 Hz (see table I). urrent rating: See table I. ircuit diagram: See figure 1. Time delay: See table I. Resistance or impedance: See table I. Part or Identifying Number (PIN): The PIN shall be M39019/06-(dash number taken from table I) (e.g., M39019/06-, M39019/06-S). ross reference: See table II. TLE I. ircuit breaker dash numbers and applicable characteristics. Dash number 1/ urrent rating (amps) Time delay Resistance or impedance (ohms - max) 2/ Standard delay 202 203 204 205 206 207 208 211 212 213 214 High inrush 300 301 302 303 304 305 306 307 308 309 310 0.05 0.05 0.05 0.1 0.1 0.1 0.5 0.5 0.5 D 60 Hz 400 Hz 680.0 680.0 680.0 150.0 150.0 150.0 5.4 5.4 5.4 1.35 690.0 690.0 690.0 170.0 170.0 170.0 2 2 2 2.7 2.7 2.7 710.0 710.0 710.0 180.0 180.0 180.0 27.0 27.0 27.0 6.6 6.6 6.6 2.8 2.8 2.8 1.61 See footnotes at end of table. 4

TLE I. ircuit breaker dash numbers and applicable characteristics - ontinued. Dash number 1/ urrent rating (amps) Time delay Resistance or impedance (ohms - max) 2/ Standard delay 217 218 219 220 221 222 223 226 227 228 229 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 250 High inrush 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 2.0 2.0 2.0 3.0 3.0 3.0 4.0 4.0 4.0 5.0 5.0 5.0 7.0 7.0 7.0 7.5 7.5 7.5 8.0 8.0 8.0 9.0 9.0 9.0 10.0 10.0 10.0 D 60 Hz 400 Hz 1.35 1.35 0.061 0.061 0.061 0.042 0.042 0.042 0.027 0.027 0.027 0.018 0.018 0.018 0.063 0.063 0.063 0.043 0.043 0.043 0.021 0.021 0.021 1.61 1.61 0.50 0.50 0.50 0.27 0.27 0.27 0.17 0.17 0.17 0.12 0.12 0.12 0.072 0.072 0.072 0.050 0.050 0.050 0.040 0.040 0.040 0.038 0.038 0.038 0.035 0.035 0.035 0.024 0.024 0.024 See footnotes at end of table. 5

TLE I. ircuit breaker dash numbers and applicable characteristics - ontinued. Dash number 1/ urrent rating (amps) Time delay Resistance or impedance (ohms - max) 2/ Standard delay 251 252 253 256 259 260 261 262 263 264 265 High inrush 334 335 336 337 338 339 340 341 342 343 1 1 1 15.0 15.0 15.0 1.25 1.25 1.25 D 60 Hz 400 Hz 0.012 0.012 0.012 0.9 0.9 0.9 0.65 0.65 0.65 0.013 0.013 0.013 0.70 0.70 0.70 0.015 0.015 0.015 0.010 0.010 0.010 0.007 0.007 0.007 1.1 1.1 1.1 1/ For configuration 2, add "S" at end of dash number. 2/ The corresponding maximum wattage losses, which in no case shall exceed 3.0 watts, may be calculated as I 2 R or I 2 Z. 6

7 TLE II. ross reference of superseded s. Superseded MIL--39019/6 M39019/6- New M39019/06- Superseded MIL--39019/6 M39019/6- New M39019/06- Superseded MIL--39019/6 M39019/6- New M39019/06-1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 218 219 218 219 218 219 227 228 227 228 227 228 233 234 233 234 233 234 236 237 236 237 236 237 242 243 242 243 242 243 245 246 245 246 245 246 251 252 251 252 251 252

The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. idders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. ustodians: rmy - R Navy - E ir Force - 85 DL - Preparing activity: rmy - R gent: DL - Review activities: (Project 5925-9-037) rmy - T, V, MI Navy - S, M ir Force - 19, 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the SSIST Online database at https://assist.daps.dla.mil. 8