Pixelated Positron Timing Counter with SiPM-readout Scintillator for MEG II experiment

Similar documents
Design and test of an extremely high resolution Timing Counter for the MEG II experiment: preliminary results

An extreme high resolution Timing Counter for the MEG experiment Upgrade

An extreme high resolution Timing Counter for the MEG Upgrade

Liquid Xenon Scintillation Detector with UV-SiPM Readout for MEG Upgrade

Systematic study of innovative hygroscopic and non-hygroscopic crystals with SiPM array readout

Scintillation Tile Hodoscope for the PANDA Barrel Time-Of-Flight Detector

Time Resolution Improvement of an Electromagnetic Calorimeter Based on Lead Tungstate Crystals

A prototype of fine granularity lead-scintillating fiber calorimeter with imaging read-out

PoS(PhotoDet 2012)018

Production and Development status of MPPC

THE TIMING COUNTER OF THE MEG EXPERIMENT: DESIGN AND COMMISSIONING (OR HOW TO BUILD YOUR OWN HIGH TIMING RESOLUTION DETECTOR )

CAEN Tools for Discovery

arxiv: v1 [physics.ins-det] 1 Nov 2015

The Scintillating Fibre Tracker for the LHCb Upgrade. DESY Joint Instrumentation Seminar

Updates on the Central TOF System for the CLAS12 detector

arxiv:hep-ex/ v1 27 Nov 2003

Silicon PhotoMultiplier Kits

Sensors for precision timing HEP

Spectroscopy on Thick HgI 2 Detectors: A Comparison Between Planar and Pixelated Electrodes

Imaging TOP (itop), Cosmic Ray Test Stand & PID Readout Update

Studies of large dynamic range silicon photomultipliers for the CMS HCAL upgrade

Status of the CUORE Electronics and the LHCb RICH Upgrade photodetector chain

Status of the Timing Detector Plastic+SiPM Readout Option

Production of quasi-monochromatic MeV photon in a synchrotron radiation facility

THE WaveDAQ SYSTEM FOR THE MEG II UPGRADE

TitleLarge strip RPCs for the LEPS2 TOF. Author(s) Chu, M.-L.; Chang, W.-C.; Chen, J.- Equipment (2014), 766:

li, o p a f th ed lv o v ti, N sca reb g s In tio, F, Z stitu e tests o e O v o d a eters sin u i P r th e d est sezio tefa ectro lity stem l su

A flexible FPGA based QDC and TDC for the HADES and the CBM calorimeters TWEPP 2016, Karlsruhe HADES CBM

TORCH a large-area detector for high resolution time-of-flight

Design of a Gaussian Filter for the J-PARC E-14 Collaboration

Beam test of the QMB6 calibration board and HBU0 prototype

NEW PARTICLE POSITION DETERMINATION MODULES FOR DOUBLE SIDED SILICON STRIP DETECTOR AT DGFRS

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Review of the CMS muon detector system

STUDY OF ANODE SELF-TRIGGER ABILITY OF ME1/1 CMS ENDCAP CATHODE STRIP CHAMBER

Tests of Timing Properties of Silicon Photomultipliers

Solid State Photon-Counters

Results on 0.7% X0 thick Pixel Modules for the ATLAS Detector.

R&D on high performance RPC for the ATLAS Phase-II upgrade

The Time-of-Flight Detector for the ALICE experiment

HAPD and Electronics Updates

TIMING COUNTER: status report. Flavio Gatti - Lecce, Sept 23, INFN Genova, Pavia, Roma1

SPE analysis of high efficiency PMTs for the DEAP-3600 dark matter detector

A fast and precise COME & KISS* QDC and TDC for diamond detectors and further applications

PoS(EPS-HEP2015)525. The RF system for FCC-ee. A. Butterworth CERN 1211 Geneva 23, Switzerland

SciFi A Large Scintillating Fibre Tracker for LHCb

Pseudospark-sourced Micro-sized Electron Beams for High Frequency klystron Applications

A new Scintillating Fibre Tracker for LHCb experiment

Large photocathode 20-inch PMT testing methods for the JUNO experiment

A Large-Area Timing RPC

... A COMPUTER SYSTEM FOR MULTIPARAMETER PULSE HEIGHT ANALYSIS AND CONTROL*

Investigation of time-of-flight PET detectors with depth encoding

Institute of Electrical and Electronics Engineers (IEEE)

Commissioning and Performance of the ATLAS Transition Radiation Tracker with High Energy Collisions at LHC

Spatial Response of Photon Detectors used in the Focusing DIRC prototype

Status of GEM-based Digital Hadron Calorimetry

3-D position sensitive CdZnTe gamma-ray spectrometers

The CALICE test beam programme

MCP Signal Extraction and Timing Studies. Kurtis Nishimura University of Hawaii LAPPD Collaboration Meeting June 11, 2010

Test beam data analysis for the CMS CASTOR calorimeter at the LHC

Hall-B Beamline Commissioning Plan for CLAS12

Drift Tubes as Muon Detectors for ILC

A very brief review of recent SiPM developments

SLAC Cosmic Ray Telescope Facility

Single Photoelectron timing resolution of SiPM

arxiv: v1 [physics.ins-det] 2 Dec 2008

Hamamatsu R1584 PMT Modifications

3 EXPERIMENTAL INVESTIGATIONS Caroline Robson. 3.1 Aims and Objectives. 3.2 Experimental Method Set Up of the Test Stand

The 20 inch MCP-PMT R&D in China

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Prospect and Plan for IRS3B Readout

The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications

4.4 Injector Linear Accelerator

Development of an Abort Gap Monitor for High-Energy Proton Rings *

Commissioning and Initial Performance of the Belle II itop PID Subdetector

Calibration of photomultiplier tubes for the large-angle beamstrahlung detector at CESR

Front End Electronics

Diamond detectors in the CMS BCM1F

Nuclear Instruments and Methods in Physics Research A

The hybrid photon detectors for the LHCb-RICH counters

Study of the performances of the ALICE muon spectrometer

Front End Electronics

Tests of AGATA preamplifiers and hints to improve their performance

Realization and Test of the Engineering Prototype of the CALICE Tile Hadron Calorimeter

Report from the 2015 AHCAL beam test at the SPS. Katja Krüger CALICE Collaboration Meeting MPP Munich 10 September 2015

Imaging diagnostico in Sanità Stato attuale e prospettive

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

Performance of the MCP-PMT for the Belle II TOP counter

Citation Review Of Scientific Instruments, 1996, v. 67 n. 1, p

A pixel chip for tracking in ALICE and particle identification in LHCb

PMT Gain & Resolution Measurements in High Magnetic Fields

Trigger-timing signal distribution system for the KEK electron/positron injector linac

Performance and aging of OPERA bakelite RPCs. A. Bertolin, R. Brugnera, F. Dal Corso, S. Dusini, A. Garfagnini, L. Stanco

CGEM-IT project update

Reading a GEM with a VLSI pixel ASIC used as a direct charge collecting anode. R.Bellazzini - INFN Pisa. Vienna February

Study of Timing and Efficiency Properties of Multi-Anode Photomultipliers

Compact, e-beam based mm-and THzwave light sources

TITLE PAGE. Title of paper: PUSH-PULL FEL, A NEW ERL CONCEPT Author: Andrew Hutton. Author Affiliation: Jefferson Lab. Requested Proceedings:

ARDESIA: an X-ray Spectroscopy detection system for synchrotron experiments based on arrays of Silicon Drift Detectors.

ABORT DIAGNOSTICS AND ANALYSIS DURING KEKB OPERATION

Transcription:

Pixelated Positron Timing Counter with SiPM-readout Scintillator for MEG II experiment Miki Nishimura a, Gianluigi Boca bc, Paolo Walter Cattaneo b, Matteo De Gerone d, Flavio Gatti de, Wataru Ootani a, Giulio Pizzigoni d, Massimo Rossella b, Naoya Shibata a, Marcello Simonetta bc, Yusuke Uchiyama a, Kohei Yoshida a The University of Tokyo a, INFN Pavia b, Dipartimento di Fisicà dell Università di Pavia c, INFN Genova d, Università degli Studi di Genova e E-mail: nmiki@icepp.s.u-tokyo.ac.jp In this paper, we introduce the positron timing counter (TC) for the MEG II experiment as an application of Silicon PhotoMultipliers (SiPM) to high-resolution timing measurement. MEG II will search for the µ eγ decay and needs a precise measurement of the positron timing. The TC is segmented in 512 counters, composed of a scintillator plate readout by SiPMs, to obtain multiple hit positron timing simultaneously such to achieve an excellent overall timing resolution of 3 ps. We performed single counter R&D to optimize the choice of the SiPM manufacturer, the number of the SiPMs, and their connection. To obtain the best resolution, we decided to employ AdvanSiD SiPMs, six of which are attached at both ends connected in series. Moreover we carried out beam tests with 8-9 counters prototypes, where we proved that positron multiple hits improve the resolution according to expectation. The desgin phase of the TC is almost finished and is under construction. International Conference on New Photo-detectors PhotoDet215, 6-9 July 215 Moscow, Troitsk, Russia Speaker. c Copyright owned by the author(s) under the terms of the Creative Commons License Attribution-NonCommercial 4. International. Attribution-NonCommercial-NoDerivatives 4. International License (CC BY-NC-ND 4.). http://pos.sissa.it/ http://pos.sissa.it/

Pixelated Positron Timing Counter with SiPM-readout Scintillator for MEG II experiment Miki Nishimura 1. Introduction Recently Silicon PhotoMultipliers (SiPMs) have been developed as new photo detectors and are utilized by many experiments. We also employed scintillator counters based on SiPM readout for precise measurement of positron timing in the MEG II experiment. The MEG II experiment is an upgrade program of the MEG experiment [1] and aims to explore new physics beyond the standard model of particle physics by searching for µ + e + + γ with a world highest sensitivity. The decay is practically forbidden in the Standard Model, while it is predicted by many new physics scenarios beyond the Standard Model. The decay is a simple twobody decay, in which the positron and the γ-ray are emitted simultaneously back-to-back with the same energy of 52.83 MeV, equal to half of the muon mass, in the rest frame of the muon. In contrast the dominant background is an accidental coincidence of a positron from Michel muon decay and an uncorrelated γ-ray. Therefore a search for µ + e + γ decay requires high precision measurements of time, energy and emission angle for both the positron and the γ-ray. Thus positron timing counter (TC) is one of the main detectors for the MEG II experiment. In the MEG experiment we used PMTs for the TC, while in MEG II we will use SiPMs, whose compact size allows us to make smaller counters and finer segmentation. As a result, we can realize positron timing measurement with high precision. In this paper we introduce the detector concept at first and then show several results of counter R&D including beam test. 2. New Positron Timing Counter The TC is composed of 512 small counters each of which consists of a fast plastic scintillator plate, of two different sizes 12x4(5)x5 mm 3, with 6 SiPMs at both ends, while in the MEG experiment the TC consists of 15 scintillator bars (8x5x5 mm 3 ) with 2 PMTs (HAMAMATSU R5924). This innovative "pixelated" design of the TC allows simultaneous measurements of positron time to obtain a better overall resolution. The overall resolution can be written as a function of a number of hits as following: σtotal(n 2 hit ) = σ single 2 + σ inter pixel 2 + σ N hit N MS(N 2 hit ), (2.1) hit where N hit is number of hits, σ single is the single counter resolution, σ inter pixel is inter-counter jitter from electronics chain. σ MS is the effect of the multiple scattering. Increasing the number of hits improves the overall resolution as demonstrated in Fig. 1 showing the number of counters hit by positrons in MC and the overall resolutions as a function of the number of hits. On average, the positrons hit nine counters and the overall timing resolution is expected 3 ps. 3. Single Counter R&D The first step in optimizing the TC performance is achieving the ultimate timing resolution with single counter [2, 3]. The key is in Fig.2 which is from beam test results discussed in Sec. 4. It shows the energy deposit dependence of the resolution and the energy deposit is proportional to the number of detected photo-electrons. Since the single counter resolution strongly depends on the number of detected photo-electrons, what we should do is to detect as many scntillation photons 2

(ps) Pixelated Positron Timing Counter with SiPM-readout Scintillator for MEG II experiment Miki Nishimura Figure 1: Left: Number of the hit counters (MC). Right: Overall resolution as a function of the number of the hit counters. as possible. To realize it we carried out several single counter tests with prototypes. In this section, we will show the results focusing on SiPM study. The simplest idea to collect many scntillation photons is to put SiPMs as much as possible. On the other hand, SiPM cannot be readout individually to avoid increasing the number of output channels. We tested single counters with two options to connect several SiPMs: the series and the parallel connections. Time resolution (ps) 2 1 9 8 7 6 5 4 ASD HPK 1 6 1 1 2 E TC (MeV) Figure 2: Dependence on the deposit energy of the time resolution. Red markers show HAMAMATSU (S1943-2547(X)) SiPM results. Blue markers show AdvanSiD (NUV type) SiPM results. Scintillator is 9x4x5 mm 3 of BC418. The set up for a single counter test is shown in Fig. 3. We measured electrons from β-decay of 9 Sr with prototype counter. For trigger and collimation a small counter (5x5x5 cm 3 BC422, one HAMAMATSU 3x3 SiPM) was put behind the prototype counter. All signals are transported to amplifier through 7.4 meter cables and shaped with pole zero cancellation to obtain sharp and short tail signals. Finally signals are digitized by DRS4 [4] at 1.6-5 GHz sampling speed. In Fig. 4, the signals from a counter, which has 3 HAMAMATSU SiPMs (S1362-33-5C) at the each side, are 3

Pixelated Positron Timing Counter with SiPM-readout Scintillator for MEG II experiment Miki Nishimura shown. Scintillator for the counter is 6x4x5 cm 3 of BC422. The waveform of the SiPMs in series connection becomes sharper than that in parallel connection because the overall capacitance in the series is smaller than that in parallel. As a result, the timing resolution with the series connection is better than that with the parallel connection as shown in Fig. 5. Therefore we employed the series connection for the TC. Digitizer Figure 3: The set up for a single counter test. Counters are inside a thermal chamber. The signals go through 7.4 m cables and amplifier, then they are digitized. 4 3 2-12 -6 [mv] [ns] 13-12 -6 Figure 4: Top: Waveform before shaping. Bottom: Waveform after shaping. Left: Waveform with parallel connection. Right: Waveform with series connection. SiPMs are HAMAMATSU S1362-33-5C. Scintillator is 6x3x5 mm 3 of BC422 4 3 2 [mv] [ns] We also compared several SiPM s manufacturers. All tested samples are 3x3 mm 2. They are HAMAMATSU old type (S1362-33-5C), HAMAMATSU new type (S12572-5C(X), S12572-2C(X)), HAMAMATSU trench type (S12652-5(X)), AdvanSiD (NUV type), KETEK (PM335 prototype-a), and SenceL (MicroFB-35-SMT B-Type). In these tests we used BC422 scintillator of 6x3x5 mm 3. The resolutions are summarized in Fig. 6. Since the PDEs of HAMA- MATSU SiPMs are higher than the others, the resolutions with HAMAMATSU are the best. However we can improve the resolution by increasing the sensor coverage with more SiPMs attached to a counter even if the single counter resolution is slightly worse. In Fig. 7 the timing 4

Time resolution (ps) Pixelated Positron Timing Counter with SiPM-readout Scintillator for MEG II experiment Miki Nishimura Resolution(ps) 12 Parallel Series Resolution (ps) 9 8 7 S1362 33 5C S12572 25C(X) PM335 prototype A MicroFB 35 SMT S12572 5C(X) 3X3MM5UMLCT B ASD NUV3S P 5 8 6 6 4 1 2 3 OverVoltage(V) Figure 5: The resolutions of the parallel connection and series connections versus the Over Voltages. SiPMs are HAMAMATSU S1362-33- 5C. Scintillator is 6x3x5 mm 3 of BC422. 5 4 3 2 4 6 8 Over voltage/sipm (V) Figure 6: Dependence of the timing resolution versus Over Voltage for different manufacturers. The counter has 3 SiPMs at both ends. Scintillator is 6x3x5 mm 3 of BC422. resolution versus Over Voltage for different numbers of SiPMs with 9x3x5 mm 3 BC422 scintillator for AdvanSiD SiPMs is shown. The more SiPMs are attached to the scintillator, the better the resolution is. Thus the resolution with 6 AdvanSiD counter (5 ps) is better than that with 3 HAMAMATSU counters (58 ps). From cost point of view, we decided to use AdvanSiD SiPMs and attach 6 SiPMs at both ends of a counter. Resolution (ps) 9 8 7 6 5 3 Series 4 5 Series 6 Series 3 3 3.5 4 4.5 5 5.5 6 Over voltage/sipm (V) 8 6 4 2 HAMAMATSU (3 series) σ(n) = 75. 2 /N +. 2 σ(n) = 64.6 2 /N + 8. 2 AdvanSiD (3 series) Expectation from Single Counter Resolution 1 2 3 4 5 6 7 8 N Figure 7: The resolutions with 3, 5, and 6 AdvanSiD SiPMs in series connection. Scintillator is 9x3x5 mm 3 of BC422 Figure 8: The resolutions as a function of the number of hits in a beam test at BTF. Red markers: HAMAMATSU (S1943-2547(X)). Blue markers: AdvanSiD (NUV type). Scintillator is 9x4x5 mm 3 of BC418 The design of single counter parameters was fixed after several tests to optimize the number of photo-electrons and a better resolution. Finally we decided to employ AdvanSiD SiPMs with BC422 scintillator of 12x4x5 mm 3 and 12x5x5 mm 3. With 12x4x5 mm 3 scintillator and 5

Pixelated Positron Timing Counter with SiPM-readout Scintillator for MEG II experiment Miki Nishimura 6-series-AdvanSiD we obtained the single counter resolution of 65 ps. 4. Beam Tests The main concept of the TC, obtaining an excellent overall resolution by simultaneous timing measurements with multiple counters, was proved by three beam tests. Two of them was carried out at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali di Frascati in Italy [5]. A monochromatic 48 MeV positron beam was used. We prepared 8-9 prototype counters in a background free environment where there are 1-3 positrons in a bunch at 5 Hz. Straight positrons without magnetic field impinge on the prototype counters. We also prepared a reference counter and the timing resolution was calculated by the difference between prototype and reference counters. In Fig. 8 the overall resolution as a function of number of hits is shown. We can see improvement of the timing resolution with 1/ N hit. For example a prototype counter with 3 HAMAMATSU (S1943-2547(X)) SiPMs has the resolution of 65 ps. The overall expected resolution with 8 counters is 23 ps. In fact we obtained consistent result, which is 25 ps with 8 counters. In these beam tests, we proved that multiple hits lead to a timing resolution improvement with the number of hit counters. In the other beam test the rate dependence of the multiple hit scheme was studied. It was carried out in Paul Scherrer Institut. The set up of the prototype counters is similar to previous beam tests. We used the same muon beam line as MEG II but without magnetic field. Prototype counters are hit by a positron generated by muon Michel decay. The positron rate for single counter in MEG II is calculated by Monte Carlo simulation, and is 7 khz on average. Therefore we adjusted the positron rate to be close to the one expected in MEG II. We tested prototype counters at the expected rate (53-166 khz), lower rate (18-64 khz), and higher rate (89-29 khz). Note that the hit rate depends on the position of the counter. The resolution improvement is visible at all rates in Fig. 9. Small degradation of the resolution compared to the expectation was observed at the higher rate. However at the expected rate it is negligible and the validity of the multiple hit scheme is confirmed at the MEG II environment. In this beam test we used positrons without magnetic fields. However we plan an engineering run in December 215 to study the detector performance in the magnetic field and rate of the MEG II experiment. Now we are already in the construction phase of the TC. We are making 512 counters and testing them toward the engineering run. 5. Summary We introduce the concept of the positron timing counter for MEG II in this paper. "Pixelated" design can be realized by small counters with SiPMs. Thanks to this novel design each positron hits several counters, as a result the overall resolution can be improved. To realize TC, we carried out a systematic R&D. First we optimized the single counter design such as the SiPM Manufacturer, the number of SiPMs and their connection. In addition, beam tests with 8-9 counters confirmed the expected resolution with multiple counter hits even at the rate expected in MEG II. Thus we confirmed the TC basic system and the construction is ongoing toward the engineering run in December 215 to confirm its performance in the experimental environment. 6

(ps) (ps) (ps) Pixelated Positron Timing Counter with SiPM-readout Scintillator for MEG II experiment Miki Nishimura Figure 9: The resolutions as a function of the number of hit counters at lower (18-64 khz), expected (53-166 khz), and higher (89-29 khz) rate. Red markers show data. Solid lines show the expectation from single counter resolution. Scintillator is 12x4x5 mm 3 and 12x5x5 mm 3 of EJ232. Each counter has 6 SiPMs (AdvanSiD NUV type) at both ends. Note: Since there was problem in the production of SiPMs in AdvanSiD, the obtained resolution of a single counter is worse then expected. References [1] J. Adam et.al., Phys. Rev. Lett.11.2181 (213). [2] M. De Gerone et al., J. Instrum. 9 (214) C235. arxiv:1312.871, [3] P.W. Cattaneo,M. et al., IEEE Trans. Nucl. Sci. 61 (5) (214) 2657-2666. arxiv:142.144. [4] S. Ritt et al., NIM-A, 623, pp. 486-488, Nov. (21). [5] G Mazzitelli, A Ghigo, F Sannibale, P Valente, G Vignola, Nucl. Instr. and Meth. A, 515(3):524, 23. 7