LENS Operating Experience

Similar documents
The PEFP 20-MeV Proton Linear Accelerator

RF plans for ESS. Morten Jensen. ESLS-RF 2013 Berlin

Pulsed Klystrons for Next Generation Neutron Sources Edward L. Eisen - CPI, Inc. Palo Alto, CA, USA

ESS: The Machine. Bucharest, 24 April Håkan Danared Deputy Head Accelerator Division. H. Danared Industry & Partner Days Bucharest Page 1

The ESS Accelerator. For Norwegian Industry and Research. Oslo, 24 Sept Håkan Danared Deputy Head Accelerator Division Group Leader Beam Physics

Performance of a DC GaAs photocathode gun for the Jefferson lab FEL

DELIVERY RECORD. Location: Ibaraki, Japan

STATUS OF THE SWISSFEL C-BAND LINEAR ACCELERATOR

Workshop on Accelerator Operations August 6-10, 2012 Glen D. Johns Accelerator Operations Manager

Oak Ridge Spallation Neutron Source Proton Power Upgrade Project and Second Target Station Project

IOT RF Power Sources for Pulsed and CW Linacs

High Brightness Injector Development and ERL Planning at Cornell. Charlie Sinclair Cornell University Laboratory for Elementary-Particle Physics

RF Solutions for Science.

Linac 4 Instrumentation K.Hanke CERN

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

Upgrading LHC Luminosity

2 Work Package and Work Unit descriptions. 2.8 WP8: RF Systems (R. Ruber, Uppsala)

Evaluation of Performance, Reliability, and Risk for High Peak Power RF Sources from S-band through X-band for Advanced Accelerator Applications

DESIGN AND PERFORMANCE OF L-BAND AND S-BAND MULTI BEAM KLYSTRONS

The Construction Status of CSNS Linac

BEAM DYNAMICS AND EXPERIMENT OF CPHS LINAC *

3 cerl. 3-1 cerl Overview. 3-2 High-brightness DC Photocathode Gun and Gun Test Beamline

THE OPERATION EXPERIENCE AT KOMAC*

RF Power Generation II

Detailed Design Report

Operating Experience and Reliability Improvements on the 5 kw CW Klystron at Jefferson Lab

Development of High Power Vacuum Tubes for Accelerators and Plasma Heating

TITLE PAGE. Title of paper: PUSH-PULL FEL, A NEW ERL CONCEPT Author: Andrew Hutton. Author Affiliation: Jefferson Lab. Requested Proceedings:

DESIGN OF 1.2-GEV SCL AS NEW INJECTOR FOR THE BNL AGS*

RF Power Klystrons & 20 Year Look. R. Nelson 7/15/15

Development of Multiple Beam Guns for High Power RF Sources for Accelerators and Colliders

PRESENT STATUS OF J-PARC

4.4 Injector Linear Accelerator

INFN School on Electron Accelerators. RF Power Sources and Distribution

Design, Fabrication and Testing of Gun-Collector Test Module for 6 MW Peak, 24 kw Average Power, S-Band Klystron

ILC-LNF TECHNICAL NOTE

The European Spallation Source

STATUS OF THE SwissFEL C-BAND LINAC

Proton Engineering Frontier Project

Present Status and Future Upgrade of KEKB Injector Linac

A HIGH POWER LONG PULSE HIGH EFFICIENCY MULTI BEAM KLYSTRON

Solid State Modulators for X-Band Accelerators

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

Diamond RF Status (RF Activities at Daresbury) Mike Dykes

Commissioning of Accelerators. Dr. Marc Munoz (with the help of R. Miyamoto, C. Plostinar and M. Eshraqi)

Pseudospark-sourced Micro-sized Electron Beams for High Frequency klystron Applications

LIGHT PROTON THERAPY PROJECT

Status of RF Power and Acceleration of the MAX IV - LINAC

Low-Energy Electron Linacs and Their Applications in Cargo Inspection

High-power klystrons. The benchmark in scientific research. State-of-the-art RF sources for your accelerator

OPERATIONAL EXPERIENCE AT J-PARC

The Cathode Ray Tube

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

Karin Rathsman, Håkan Danared and Rihua Zeng. Report from RF Power Source Workshop

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16]

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

EPJ Web of Conferences 95,

Recent developments in cyclotrons for proton therapy at IBA

Photo cathode RF gun -

Design of the linear accelerator for the MYRRHA project

The Elettra Storage Ring and Top-Up Operation

CHAPTER 4: HIGH ENERGY X-RAY GENERATORS: LINEAR ACCELERATORS. Jason Matney, MS, PhD

CPI Gyrotrons For Fusion EC Heating

NEW HIGH POWER 201 IEGAWERTZ RADIO FREQUENCY SYSTEM FOR THE LANSCE DRIFT TUBE LINAC. John Lyles. Carl Friedrichs Jr. Michael Lynch

RECENT PROGRESS IN UPGRADE OF THE HIGH INTENSITY THzzz zz-fel AT OzSAKzA UNIVERSITYzzzz

Design Studies For The LCLS 120 Hz RF Gun Injector

IOT OPERATIONAL EXPERIENCE ON ALICE AND EMMA AT DARESBURY LABORATORY

A Brief History of High Power RF Proton Linear Accelerators

What can be learned from HERA Experience for ILC Availability

Screen investigations for low energetic electron beams at PITZ

OF THIS DOCUMENT IS W8.MTO ^ SF6

GA A26497 SOLID-STATE HIGH-VOLTAGE CROWBAR UTILIZING SERIES-CONNECTED THYRISTORS

SRS and ERLP developments. Andrew moss

Sep 09, APPLICATION NOTE 1193 Electronic Displays Comparison

HIGH POWER BEAM DUMP AND TARGET / ACCELERATOR INTERFACE PROCEDURES *

4.9 BEAM BLANKING AND PULSING OPTIONS

TECHNICAL SPECIFICATION Multi-beam S-band Klystron type BT267

DISCLAIMER. Portions of this document may be illegible in electronic image products. Images are produced from the best available original document.

PEP II Design Outline

Status and Plans for PEP-II

TESLA FEL-Report

DEVELOPMENT OF A 10 MW SHEET BEAM KLYSTRON FOR THE ILC*

E2V Technologies CX2668A, CX2668AX Air-Cooled, Hollow Anode, Two-Gap Metal/Ceramic Thyratrons

Pulses inside the pulse mode of operation at RF Gun

High Power ARNS/IFF Limiter Module: Ultra Low Flat Leakage & Fast Recovery Time

Spear3 RF System Sam Park 11/06/2003. Spear3 RF System. High Power Components Operation and Control. RF Requirement.

Recent ITER-Relevant Gyrotron Tests

A New 4MW LHCD System for EAST

Production of quasi-monochromatic MeV photon in a synchrotron radiation facility

This work was supported by FINEP (Research and Projects Financing) under contract

Requirements for the Beam Abort Magnet and Dump

DEVELOPMENT OF X-BAND KLYSTRON TECHNOLOGY AT SLAC

Klystron Tubes. Two forms of such a device, also called linear beam klystron, are given in the following figure.

Yet Another KW Amplifier for 432

ESS Linac WP8 Radio Frequency Systems and Test Facilities

Lecture 17 Microwave Tubes: Part I

III. Proton-therapytherapy. Rome SB - 3/5 1

Activities on FEL Development and Application at Kyoto University

Karin Rathsman. Calculations on the RF Source and Distribution

3-D position sensitive CdZnTe gamma-ray spectrometers

Transcription:

Available online at www.sciencedirect.com Physics Procedia 26 (2012 ) 161 167 Union of Compact Accelerator-driven Neutron Sources I & II LENS Operating Experience T. Rinckel *a, David V. Baxter a,b, J. Doskow a, Helmut Kaiser a,b, R. Pynn a,b, P. E. Sokol a,b, and T. Todd a a Center for the Exploration of Energy and Matter, and b Dept. of Physics, Indiana University, Bloomington, IN 47405, USA Abstract Indiana University is operating a Low Energy Neutron Source which provides cold neutrons for material research and neutron physics and MeV energy for the neutron radiation effects studies. Neutrons are being produced by a 13 MeV proton beam incident on a Beryllium target. The LENS Proton Delivery System (PDS) is routinely operating at 13 MeV and 25 ma at 1.8% duty factor. The RF system, consisting of three Litton 5773 klystron RF tubes at 425 MHz and 1 MW each, power the AccSys Technology PL-13 LINAC. The proton beam delivers up to 6 kilowatts of power to the Beryllium target. Details of the beam spreading system, target cooling system, and accelerator operations will be discussed. 2012 2011 Published by Elsevier Ltd. B.V. Selection and/or peer-review under responsibility of of UCANS. Keywords: Neutron Source; Klystrons; neutron target 1. LENS Overview The Low Energy Neutron Source (LENS) at Indiana University is the first university-based pulsed neutron source in the U.S. The facility utilizes low energy (p,n) reactions in a beryllium target coupled to a light water reflector and cold methane moderator, to produce time-averaged thermal neutron fluxes suitable for neutron scattering and development of instrumentation. LENS has a threefold mission to perform research with neutrons, educate students in neutron science, and develop new neutron instrumentation and technology. LENS will also provide a test bed in the development of very-cold neutron sources [1,2]. In this paper we provide a brief overview of the facility and discuss some of the most significant operational issues that have arisen during its first several years of operation. LENS has two instrumented neutron beam lines, with two more available for future expansion. At present, the instrumentation suite is directed toward large-scale structure measurements with a conventional Small Angle Neutron Scattering (SANS) instrument and Spin Echo Scattering Angle Corresponding author: Tel 1-812-855-5197 E-mail address: trinckel@indiana.edu 1875-3892 2012 Published by Elsevier B.V. Selection and/or peer-review under responsibility of UCANS doi:10.1016/j.phpro.2012.03.021

162 T. Rinckel et al. / Physics Procedia 26 ( 2012 ) 161 167 MEasurement (SESAME) for extending structural studies beyond the range of conventional SANS. The low proton energy used in LENS yields limited activation in the source, making this facility ideal for technical studies of neutron moderation and a variety of educational programs. The variable pulse length facilitates investigation of long-pulse instrumentation concepts. The low energy of the proton beam allows a lower moderator operating temperature (below 10K), giving a colder neutron spectrum. A second target station is also available for epithermal and fast neutron applications (primarily radiation effects in electronics and radiography). Fig. 1. Layout of the LENS facility, showing the cryogenic-moderator target station with scattering instruments (near the top of the figure) along with the radiation effects target station, the accelerator and the RF power systems. 2. The LENS Proton Accelerator The LENS proton accelerator provides a 25 ma (peak current), 13 MeV beam with up to 6 kilowatts of beam power, by utilizing a PL-13 LINAC. The proton beam has a variable pulse width ranging from 10 s to 1.0 ms and the facility has been run with repetition rates from 10 to 45 Hertz, although for scattering experiments it is most commonly run at 20Hz and a beam power of 3 to 4 kw. The PL-13 consists of a 3 MeV Radio Frequency Quadrupole (RFQ) followed by a 4 MeV drift tube LINAC (DTL) section and a 6 MeV DTL section for a total energy of 13 MeV.

T. Rinckel et al. / Physics Procedia 26 ( 2012 ) 161 167 163 Fig. 2. Oscilloscope traces showing the current through two of the three klystrons (top two traces), the mod-anode voltage controlling one klystron (second lowest trace), and the RFQ cavity power (lowest trace) for one 900 msec-long cycle). The LENS RF amplifier system uses the 1.25 MW, 425 MHz BMEWS klystrons to drive the RFQ / DTL structures. By utilizing a totem-pole modulator [3] with an on-deck and an off-deck, fast klystron beam switching and RF capability is obtained. The LENS installation has two klystron modulator systems, a single tube klystron system and a two tube klystron modulator system. The klystron beam current rise time of the single tube modulator is about a 30 s (top, or blue trace) and the 2 tube modulator has about a 75 s rise time (second, or violet trace) as noted in Figure 2. What can be noted from these traces is that the beam currents are flat-topped. The flat-topped beam in the klystrons maintains the RF characteristics of the tube. By coupling the capacitor bank droop into the klystron modulator on-deck electronics, a fixed mod-anode to cathode voltage results in the flat-topped klystron beam currents. This klystron mod-anode voltage is depicted by the red trace in the Figure 2. The green trace is the RFQ cavity RF power. The filling of the RFQ cavity is used to define the proton pulse width, and consequently the proton current pulse, which closely mimics this last trace, is shown in figure 3. At present, the peak beam current is limited to no more than 25mA by the relatively low injection voltage of the RFQ, so increased beam power is realized by lengthening the duration of the proton pulse. Figure 3 shows the proton beam pulse as measured by 2 current transformers, one at the accelerator exit (pink) and the other before the target (green). The pulse is also monitored by a RF time-of-flight pickup shown in light blue. We note the rapid rise and fall in the beam current with a relatively flat profile during the pulse. The beam current rise time is approximately 3 s, and the trailing edge is similarly short. This has been used to produce square beam profiles as narrow as 13 s in investigations of moderator emission time performance.

164 T. Rinckel et al. / Physics Procedia 26 ( 2012 ) 161 167 Fig. 3. Beam current measured in the LENS proton delivery line when operating in long-pulse mode for scattering applications. The klystron systems at LENS originally made use of a legacy modulation anode tube design (using Litton L-3408 injectron switch tubes). Although these tubes performed well, replacements are impossible to obtain, and as our supply of tubes diminished we were forced to consider a new design. In partnership with personnel from Los Alamos National Lab, we now employ a modern tube (CPI emac division Y- 847B). The first version of this new tube that was installed produced an unacceptably large number of klystron trips (several per day) due to sparking in the mod-anode, but after some modifications to the manufacturing process, this problem now appears to be under control with the most recent version of the tube that we have used. 3. Neutron Production The proton beam is spread out on the target using non-linear focusing devices consisting of two octupole magnets shown in Figure 4. These magnets, one for X and the other for the Y direction, along with standard quadrupole magnets, produce a beam that is approximately uniformly distributed across a 3 cm high by 4 cm wide area as seen in the Figure 5. The power density on the beryllium plate at our highest beam power to date is 500 Watts/cm 2 average (28 kwatts/cm 2 instantaneous). During the first several years of operation of the facility, target issues were a significant cause of down time and these are discussed in greater detail elsewhere in this volume [4]. Radiolysis in the water produced a buildup of corrosion products on the back of the target leading to insufficient cooling and target failure. In addition to this, our original target design was thick enough for the proton beam to range out within the target itself and the resulting hydrogen buildup in the target rapidly exceeded the mechanical limits of the material.

T. Rinckel et al. / Physics Procedia 26 ( 2012 ) 161 167 165 Fig. 4 Mechanical drawing showing one of the two octopole magnets used to spread the LENS proton beam on the target. The octopoles encircle the 4.0 diameter beam pipe containing the beam. The Beryllium target is a flat plate design that is directly cooled by water flowing across the back surface at 5 gpm. The water system, constructed of mostly Aluminum piping and has charcoal and deionizing filters to eliminate the build-up of corrosion products on the back side of the target The filters are used to maintain water conditions of resistivity >1M -cm and total dissolved solids below 0.5mg/l. The target is now only 1.2 mm thick, allowing the protons to stop in the cooling water. By stopping the protons in the cooling water, we eliminate the buildup of hydrogen in the Beryllium which causes the target to burst [4], although it should also be noted that this choice exacerbates the water chemistry problems, forcing more aggressive remediation than was needed with the thicker Be target. Fig. 5. View of the vacuum side of the LENS target showing the rectangular beam profile left on the target from cracking of residual gases in the vacuum system by the proton beam. The LENS thermal/cold TMR is designed as a source of cold and thermal neutrons that is both highly efficient and intense while minimizing background neutrons. The design, shown in figure 6, was optimized using the MCNP series of Monte Carlo codes, and has demonstrated an adequate flux for conducting materials research as well as the flexibility we had envisioned for neutron moderator development. The moderator and TMR shielding was designed to allow frequent changes to the moderator system facilitating a moderator research program [5]. This is facilitated primarily by keeping the proton beam

166 T. Rinckel et al. / Physics Procedia 26 ( 2012 ) 161 167 energy at 13 MeV or below, and by the use of Al alloys in the construction of the central hardware in the TMR. The key elements of the design are displayed in figure 6. Cryogenic Methane Moderator Water Reflector Water-Cooled Beryllium Target Polyethylene/ Borax/Epoxy/ Lead Composite Neutron Beam Lines Fig. 6. Section drawing of the LENS Target Moderator Reflector assembly, with a 50-cm diameter water reflector surrounding the target in the center. The closed-cycle refrigerator used to cool the methane is visible near the top as are the layers of lead and polyethylene/epoxy/borax shielding surrounding the source. The LENS facility at IU is operational and it provides neutron beams for neutron sciences. Although we have demonstrated the ability to run the accelerator at up to 6 kw of beam power, and the target design is suitable for power levels as high as 13 kw, for neutron scattering operations the facility has typically been run at 4kW of beam power to enhance reliability as we have worked through operational issues with the target and RF systems. Acknowledgements Construction of LENS was supported by the National Science Foundation grants DMR-0220560 and DMR-0320627, the 21 st Century Science and Technology fund of Indiana, Indiana University, and the Department of Defense. Operation of LENS is supported by Indiana University, and some of the experiments described in this paper were supported with funds from the US Department of Energy. The facility is currently operated within the Center for the Exploration of Energy and Matter at Indiana University with support from the IU Office of the Vice Provost for Research.

T. Rinckel et al. / Physics Procedia 26 ( 2012 ) 161 167 167 References [1] D.V. Baxter et al., Nucl. Instr. Meth. B241 209-212 (2005) [2] C. M. Lavelle, David V. Baxter, M. A. Lone, H. Nann, J. M. Cameron, V. P. Derenchuk. et al., Nucl. Instr. Methods, A587, 324-341 (2008). [3] Fast totem-pole grid-catch mod-anode modulator for the Indiana University LENS klystron RF amplifier system: W.A. Reass, W.T. Roybal, J.L. Davis, T. Rinckel, V.P. Derenchuk, 2008 IEEE International Power Modulators and High Voltage Conference, Las Vegas, NV, pp 235-237. [5] See the summary of LENS target performance by T. C. Rinckel elsewhere in these proceedings. [6] See reports from D. V. Baxter elsewhere in this proceedings.