Phil L. Thomas Performing Arts Center Shiprock, New Mexico Technical Specifications STAGE DIMENSIONS Proscenium 45-4 wide x 24 high Proscenium to up stage wall 29 6 (from back of proscenium opening wall) Proscenium to up stage edge of thrust stage 10 (from back face of 2 thick proscenium wall Stage right wing 13 4 wide x 29 6 long Stage left wing 23 4 wide x 29 6 long Wing to wing 82 0 Height of stage from the main floor 3 0 Fly Information see Hanging Plot (TBA) Stage floor to grid: 58 0 Locking rails stage left Stage level Counter weight house, single purchase 21 pipes 8" centers (3) leg sets 60' long (1) Mid-stage traveler 60' long (1) Upstage traveler 60' long (6) Spares 43' long Additionally, (3) electrics 43' long, Grand Valance (60 ), Grand Drape Traveler (60'), (3) Borders (60'), Cyclorama (60 ) and Projection screen (60 ) All pipes operated stage left only Arbor capacity 1100 lbs each (see hanging plot) House has 80% of total capacity for all arbors DRAPERIES Main Curtain 26 wide x 31 high, 22 oz. plum velour, bi-parting and flies (3) Teaser Borders - Flies only Legs 3 pair - 6 6 wide x 29 high Borders 3 each, 50 wide x 8 high Natural cyclorama (flat), 40 wide x 25 high PROJECTION SCREEN 20' high x 36' wide
LOADING DOCK / DOOR (1) dock, upstage, right South door - 12' wide x 16' high At pavement, levelers on each dock Door loads directly into Scenery Shop ORCHESTRA PIT No pit. First (3) rows of house seats removable Length 25' Width 11' - 6' LIGHTING Stage electrics wired with grounded stage pin connectors. Light Board: Strand 520i Dimmers: Strand SV (2) Strand SB Racks (136) circuits (8) Non-dims Strand SWC Houselights System 1000 Channel WYSIWYG Wireless IPAC Wireless Network (2) Control input stations (stage and booth) Front of House (L1) Distribution Strip 21 ft., 10 ckt. Floor Pocket (FB) w/ insert plate, 3 ckt., w/ pocket lid Stage electric No. 1 (S1) Distribution strip, 43 ft. long and 24 ckt. Stage electric No. 2 (S2) Distribution strip, 43 ft. long and 18 ckt. Stage electric No. 3 (S3) Distribution strip, 43 ft. long and 15 ckt. Tormentor Plg Box (T) Stage Drop Box (D1) Company Switch: N/A Sound Power: Inquire Technical Director or Facility Manager LIGHTNING INSTRUMENTS (12) 6" Fresnels (w/ 8-leaf barn doors & top hats), 1kW lamp (20) 23-50 Zoom Ellipsoidals w/ 575W lamp (10) 19 Ellipsoidals w/ 575W lamp (4) 26 Ellipsoidals w/ 575W lamp
3-Circuit, 3-Cell Cyclorama Light w/ 1000W Lamp Stage Electric Work Light w/ Edison Connector w/ 500W lamp For design purposes, assume 5% of every type are not usable. Do not design using all instruments. FOLLOW SPOTS (1) Lycian Super arc 400 #1267 - located in projection booth at rear of theater, 20' above stage - 80' throw to proscenium. GEL / GOBOS House supply limited. If gel or gobos are required, sufficient notice (4 weeks) must be given for the house to obtain them at the user s expense or the user must supply them. ELECTRICS (2) - electric (grid) drop boxes, 2 S.R., 2 S.R. FRONT OF HOUSE HANG POSITIONS #1 Rail 36'6 to proscenium line, 45-degree angle. 20 amp circuits, paired. #2 Box Booms House Left & Right - 6 circuits each, 24' above stage Level, 52' throw to proscenium line. #3 High Cove Plugs are grounded stage pin male, on 20 amp breakers. All FOH positions patchable to road boards at company switch. (dmx512) SOUND REINFORCEMENT AUDIO SPECIFICATIONS Front of House: (1) Soundcraft Spirit Live 4-2 40 channel console (3) Rane ME-15B Dual 15band Equalizers (1) Denon DRM-555P Cassette Deck (1) Denon DN-C550R CD Recorder MICROPHONES & INPUT DEVICES: (4) Audio Technica ATM-41HE Vocal Mics (4) Audio Technica ATM-29HE Instrument Mics (7) Audio Technica Pro45 Hanging Mics (1) Audio Technica AT835ST Stereo Mic (4) Audio Technica ATW-3110D Wireless w/mt830cw Lapel Mic (3) Crown PCC 160D Unidirectional Boundary Mics (1) Crown PZM 30D Omnidirectional Boundary Mic (3) CBI Proel Direct In Boxes (1) - Dean Markley Promag Acoustic Pick-Up
Left, Right, Center Mains (flown) (3) EAW MK-5164e (running passive with one channel of a QSC CX702 amp each) Left, Center, Right down Fills (flown) (3) EAW MK-2164e (running passive with one channel of a QSC CX702 amp each) Left, Center, Right Delays (flown in clouds) (3) EAW MK-2164e (running passive with one channel of a QSC CX702 amp each) Subwoofers (2) EAW SB-250 (flown in center cluster with two channels of a QSC CX702 amp each) Speaker Processor (1) BiAmp Audia Solo 4X12 Monitors (4) EAW SM129z (2) QSC CX702 Amps Interconnect (3) 8 Input Wall Panels (2) 8 channel Sub Snakes MUSICAL INSTRUMENTS (HOUSE) & ON-STAGE EQUIPMENT (1) Steinway 7 Piano Piano tuning arranged through the PAC Manager (1) Pearl Concert Bass Drum w/ Stand (40) Wenger Roughneck Music Stands (20) Wenger 19 NOTA Musician s Chairs FLATAGE & THEATRICAL SUPPORT SUPPLIES (10) 4 X 8 Standard Modular Flatage Units COMMUNICATION SYSTEM Two-channel Clear Com headset system with permanent receptacles in all possible production sites through out the theater. Sound Mix Position Position A - Sound Booth-Orchestra Level 2, Back of House Center - snake run, approximately ' from proscenium line. Sound Booth is?? Not?? Isolated from
house. Entire front of booth opens to house.?? House system is located in Sound Booth. Position B - Back of House Right - snake run, approximately ' from proscenium line.?? NOTE: CAST CALL OPERATES ONLY FROM STAGE LEFT DRESSING ROOMS Dressing rooms have lighted mirrors Separate available areas have lockers, clothes racks, toilets and shower facilities Dressing room is accessible stage left or stage right Star STAR DRESSING ROOM - Please inquire through Center Manager or PAC Technician PRODUCTION OFFICE Please inquire through either Center Manager or PAC Technician SCENERY / SET SHOP & WORKSHOP INVENTORY Please inquire through either Center Manager or PAC Technician