Soft x-ray optical diagnostics, concepts and issues for NGLS

Similar documents
Future Performance of the LCLS

Digital BPMs and Orbit Feedback Systems

Current status of XFEL/SPring-8 project and SCSS test accelerator

Photo cathode RF gun -

Beam Instrumentation for X-ray FELs

Simulations on Beam Monitor Systems for Longitudinal Feedback Schemes at FLASH.

Demonstra*on of Two- color XFEL Opera*on and Autocorrela*on Measurement at SACLA

Design Studies For The LCLS 120 Hz RF Gun Injector

Compact, e-beam based mm-and THzwave light sources

TWO BUNCHES WITH NS-SEPARATION WITH LCLS*

EUROFEL-Report-2007-DS EUROPEAN FEL Design Study

Spontaneous Emission High Gain Harmonic Generation Free Electron Laser

TESLA FEL-Report

Beam Instrumentation for CTF3 and CLIC

Overview of the Stanford Picosecond FEL Center DUV-VEL

RF considerations for SwissFEL

The basic parameters of the pre-injector are listed in the Table below. 100 MeV

THE PHYSICS AND APPLICATIONS OF HIGH BRIGHTNESS BEAMS: WORKING GROUP C SUMMARY ON APPLICATIONS TO FELS *

THE FIRST ANGSTROM X-RAY FREE-ELECTRON LASER

Experience with the Cornell ERL Injector SRF Cryomodule during High Beam Current Operation

Status of Elettra, top-up and other upgrades

Report on the LCLS Injector Technical Review

sflash First Seeding at FLASH On behalf of the sflash team Jörn Bödewadt Hamburg University

Diamond RF Status (RF Activities at Daresbury) Mike Dykes

The Elettra Storage Ring and Top-Up Operation

Summary of the 1 st Beam Line Review Meeting Injector ( )

RECENT PROGRESS IN UPGRADE OF THE HIGH INTENSITY THzzz zz-fel AT OzSAKzA UNIVERSITYzzzz

Femto second FEL Generation with Very Low Charge at LCLS

LCLS Injector Technical Review

High Brightness Injector Development and ERL Planning at Cornell. Charlie Sinclair Cornell University Laboratory for Elementary-Particle Physics

LCLS RF Reference and Control R. Akre Last Update Sector 0 RF and Timing Systems

TITLE PAGE. Title of paper: PUSH-PULL FEL, A NEW ERL CONCEPT Author: Andrew Hutton. Author Affiliation: Jefferson Lab. Requested Proceedings:

The FLASH objective: SASE between 60 and 13 nm

STATUS OF THE SWISSFEL C-BAND LINEAR ACCELERATOR

Technical Document 1 attached to the European XFEL Convention

Photoinjector Laser Operation and Cathode Performance

Performance of a DC GaAs photocathode gun for the Jefferson lab FEL

P. Emma, et al. LCLS Operations Lectures

Drive Laser Operations

Linac-Beam Characterizations at 600 MeV Using Optical Transition Radiation Diagnostics *

Suppression of Timing drift between laser and electron beam driven photo-cathode RF gun

Activities on FEL Development and Application at Kyoto University

PROJECT DESCRIPTION. Longitudinal phase space monitors for the ILC injectors and bunch compressors

Polygon Scanners Capabilities, Applications and System integration. considerations

GFT Channel Digital Delay Generator

RUNNING EXPERIENCE OF FZD SRF PHOTOINJECTOR

STATUS REPORT ON THE COMMISSIONING OF THE JAPANESE XFEL AT SPRING-8

Industrial Diode Laser (IDL) System IDL Series

Summary report on synchronization, diagnostics and instrumentation

Status of RF Power and Acceleration of the MAX IV - LINAC

SIMULTANEOUS OPERATION OF THREE LASER SYSTEMS AT THE FLASH PHOTOINJECTOR

SPEAR 3: Operations Update and Impact of Top-Off Injection

Status of the X-ray FEL control system at SPring-8

G0 Laser Status Parity Controls Injector Diagnostics

3 cerl. 3-1 cerl Overview. 3-2 High-brightness DC Photocathode Gun and Gun Test Beamline

Recent APS Storage Ring Instrumentation Developments. Glenn Decker Advanced Photon Source Beam Diagnostics March 1, 2010

IOT OPERATIONAL EXPERIENCE ON ALICE AND EMMA AT DARESBURY LABORATORY

SUMMARY OF THE ILC R&D AND DESIGN

Lasing with Long Bunch Trains

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

STATUS OF THE SwissFEL C-BAND LINAC

30 GHz Power Production / Beam Line

Linac 4 Instrumentation K.Hanke CERN

AN OPTICAL AND TERAHERTZ INSTRUMENTATION SYSTEM AT THE FAST LINAC AT FERMILAB*

Detailed Design Report

Experimental environment with optical lasers in 2020

CLIC Feasibility Demonstration at CTF3

CBF500 High resolution Streak camera

Status of the Jefferson Lab Polarized Beam Physics Program and Preparations for Upcoming Parity Experiments

4.4 Injector Linear Accelerator

Beam Losses During LCLS Injector Phase-1 1 Operation

Focus of efforts. ILC 2010, Mar/27/10 A. Seryi, BDS: 2

RF Power Generation II

HP 70950B OPTICAL SPECTRUM ANALYZER

JLab 10kW FEL Driver Beam Diagnostics

Screen investigations for low energetic electron beams at PITZ

GFT Channel Slave Generator

Observation of Transverse-Longitudinal Coupling Effect at UVSOR-II

BUNCH-COMPRESSOR TRANSVERSE PROFILE MONITORS OF THE SwissFEL INJECTOR TEST FACILITY

Beam Loss Detection for MPS at FRIB

SABER A Facility for Accelerator Physics and Test Beam Experiments Roger Erickson SABER Workshop March 15, 2006

An Overview of Beam Diagnostic and Control Systems for AREAL Linac

High Rep Rate Guns: FZD Superconducting RF Photogun

Start to End Simulations

ModBox-850nm-NRZ-series

Large-Scale Polysilicon Surface Micro-Machined Spatial Light Modulator

Leica TCS CARS. Live Molecular Profiling Technical Documentation. Living up to Life

Advanced Sensor Technologies

Paul Scherrer Institut

The FLASH Facility: Advanced Options for FLASH2 and Future Perspectives

KARA and FLUTE RF Overview/status

Flash Single Color Datasheet

reported by T. Shintake KEK / RIKEN Japan Summary of C-band R&D for Linear Collider at KEK New soft-x-ray FEL Project at RIKEN/SPring-8

The PEFP 20-MeV Proton Linear Accelerator

LaserPXIe Series. Tunable Laser Source PRELIMINARY SPEC SHEET

The extremely compact laser head is approximately 480 mm long and can

Supplementary Figure 1. OLEDs/polymer thin film before and after peeled off from silicon substrate. (a) OLEDs/polymer film fabricated on the Si

Beam Line Optics at SSRL

MPX and MPZ series Low frequencies to 40 GHz Phase Modulators

ModBox-1310nm-1550nm-28Gbaud-PAM nm & 1550 nm, 28 Gbaud PAM-4 Reference Transmitter

Transcription:

Soft x-ray optical diagnostics, concepts and issues for NGLS Tony Warwick (for the NGLS project team) EuroXFEL user meeting 2013 Satellite workshop on photon beam diagnostics 24 January 2013

NGLS approach Beam spreader High brightness, high rep rate gun and injector NGLS offers : CW superconducting linac, laser heater, bunch compressors Array of independent FELs X ray beamlines and endstations CW pulse train More energy per unit bandwidth More photons per second Shorter pulses Controlled trade off between time and energy resolution

NGLS plans three FELs initially expands later to nine Three FEL Strategy proposed by Paul Emma and LBNL CBP team 10 μs 100 fs 10 μs 1 μs 5 250 fs ~1 25fs ~50 250 fs High resolution Trade-off time/energy resolution 10 11 10 12 ph/pulse 10-3 5x10-5 bandwidth Ultra-fast fs pulse capability 2 color 10 8 ph/pulse Highest rep rate High flux 10 11-10 12 ph/pulse 100 W

FEL-1: Self-seeded mono SASE up to ~ 15 MW Monochromator 10-5 rel bw Coherent und quad 11 undulators 4 60 kw going in 12 undulators 2 undulators polarization control Undulator length 3.3 m (magnetic) 1.1 m gaps # undulators includes contingency for beam quality & undulator errors Aggressive bandwidth goal Self-seeding monochromator reduces photons by 10 3 Factor 100 in reduced BW, factor 10 in losses in monochromator P. Emma, M. Reinsch, G. Penn

FEL-2: 2-Stage HGHG (100-600 ev) Ti:Saph 200 MW 200 nm 200 nm 150 mm modulator 16.7 nm 50 mm radiator fresh bunch 16.7 nm 50 mm modulator 2.08 nm 20 mm radiator 1 nm upgrade: 3 rd stage Reconfigure to Echo Seed stage 2 with HHG 2.08 nm 200 nm 16.7 nm 2.1 nm 60 MW 0.7 GW M. Reinsch, G. Penn

FEL-3: Chirped SASE 2-Color (250eV-1000 ev?) Carrier envelope phasestable 15.7 fs (2 cycle) 70 μj pulses at 2.1 μm wavelength, or less? 5 GW 2.1 m N p = 2 u = 10 cm B = 1.6 T L 50 m? 250-1000 ev? 5 GW 2.1 m 10 10 ph/pulse ~1 GW A. Zholents, NGLS Tech Note 0025

3 concepts: SXRSS + HGHG + Chirped SASE Nb3Sn planar superconducting undulator technology Config. #1 HGHG Config. #2 Chirped SASE Bunch charge = 300 pc Bunch length = 250 fs (100 fs in HGHG) ß u = 15 m min._gap = 7.5 mm Current = 600 A Emittance (norm.) = 0.6 micron Energy spread = 100 kev

Do we need spectral diagnostics?... FLASH and FERMI have diagnostic grating spectrometers on experiment floor that pass zero order to experiment

Diagnostic spectrometer source: σ=38µm σ =5µrad 50m 250eV to 600eV 300 lines mm 1 0.065 lines mm 2 α β 10m Internally water cooled silicon deformation at 0.025 mj cm 2 @1MHz

1mm 100me V 20µm Figure 8. Ray trace of operation at 500eV showing the image on the focal plane scintillator i) with no heat, ii) with thermal load corresponding to 100kHz operation and an internally water cooled silicon grating and iii) the same, with the focal plane shifted downstream 58mm to recover the focus as far as possible. Beyond this is the possibility of a cryogenic silicon grating with negligible thermal deformation.

Gratings should be long with blazed groove profile, and blaze angles shallow blaze angle grating period stripe groove density (lines/mm) blaze angle coating G101a 100±0.2% 0.2±0.02 Gold G101b 100±0.2% 0.4±0.04 Gold G102a 300±0.2% 0.4±0.04 Gold G102b 300±0.2% 0.3±0.03 Rhodium

Spectral diagnostic is certainly required to measure performance. But is this measurement required shot by shot as part of the data stream? Answer: please, no.

Do we need timing diagnostics? Spectral encoding of x-ray/optical relative delay Mina R. Bionta, H. T. Lemke, J. P. Cryan, J. M. Glownia, C. Bostedt, M. Cammarata, J.-C. Castagna, Y. Ding, D. M. Fritz, A. R. Fry, J. Krzywinski, M. Messerschmidt, S. Schorb, M. L. Swiggers, and R. N. Coffee Vol. 19, No. 22 / OPTICS EXPRESS 21855 Panel (a) shows the transmitted single shot spectra, stacked so that the abscissa and ordinate correspond to the spectrum and shot number respectively. The delay between the xrays and the laser was scanned in 500 fs steps, twice the full width at half maximum (FWHM) natural jitter of the FEL [8]. Panels (b) and (c) incrementally zoom as indicted by the white lines in previous panels. Panel (d) shows lineouts of panel (c) shots, but for both of the correlated signal traces, top = t1 and bottom = t2.

FEL-1: Self-seeded 50fs< >36meV mono SASE up to ~ 15 MW Monochromator 10-5 rel bw Coherent und quad 11 undulators 4 60 kw going in 12 undulators 2 undulators polarization control Undulator length 3.3 m (magnetic) 1.1 m gaps # undulators includes contingency for beam quality & undulator errors Aggressive bandwidth goal Self-seeding monochromator reduces photons by 10 3 Factor 100 in reduced BW, factor 10 in losses in monochromator P. Emma, M. Reinsch, G. Penn

FEL-2: 2-Stage HGHG (100-600 ev) Ti:Saph 200 MW 200 nm 200 nm 150 mm modulator 16.7 nm 50 mm radiator fresh bunch 16.7 nm 50 mm modulator 2.08 nm 20 mm radiator 1 nm upgrade: 3 rd stage Reconfigure to Echo Seed stage 2 with HHG 2.08 nm chicane jitter ~10fs?? 200 nm 16.7 nm 2.1 nm 60 MW 0.7 GW M. Reinsch, G. Penn

FEL-3: Chirped SASE 2-Color (250eV-1000 ev?) Carrier envelope phasestable 15.7 fs (2 cycle) 70 μj pulses at 2.1 μm wavelength, or less? chicane jitter ~10fs?? 5 GW 2.1 m N p = 2 u = 10 cm B = 1.6 T L 50 m? 250-1000 ev? 5 GW 2.1 m 10 10 ph/pulse ~1 GW A. Zholents, NGLS Tech Note 0025

Synchronizing Lasers Over Fiber by Transmitting Continuous Waves R. B. Wilcox and J. W. Staples Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley CA 94720 Phone: 510 495 2704, FAX: 510 486 7981, E mail: rbwilcox@lbl.gov Abstract: We have developed an interferometric method of delivering optical phase information over kilometers of fiber with sub 10fs long term stability. This enables temporal synchronization of pulsed lasers by transmission of CW signals. Relative phase delay stability between 2km and 2m stabilized fibers in femtoseconds (blue) and room temperature variation in degrees (red).

Being optimistic.. Self seeding may be synchronized to ~50fs, depending on electron bunch length. No better than SASE, except the bandwidth is controlled and may be narrow (>50meV). Laser seeding synchronization could be as good as ~10fs. Cross correlation diagnostic is required to measure (and confirm) this performance. But is this measurement required shot by shot as part of the data stream? Answer.depends on the performance

Soft x-ray optical diagnostics, concepts and issues for NGLS Tony Warwick (for the NGLS project team) EuroXFEL user meeting 2013 Satellite workshop on photon beam diagnostics 24 January 2013