Detailed Specifications & Technical Data

Similar documents
Detailed Specifications & Technical Data

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data

Product Description. Product Specifications. Technical Specifications. Construction and Dimensions. Conductor: Insulation: Color Chart 1:

Detailed Specifications & Technical Data

Part Number: 7940A Cat 6 DataTuff, (4 pr) 23 AW G Solid BC, PO/PVC, EtherNet/IP, CMR, CMX-Outdoor

Detailed Specifications & Technical Data

GenSPEED Category 5e Cables 3

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

1672A. Product Description. Product Specifications. Technical Specifications. Conductor. APAC Standard. Bend Radius.

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

Part Number: 7965ENH Category 6 Nonbonded-Pair ScTP Cable

STRUCTURED CABLING SYSTEMS (SCS)

SHIELDED DIGITAL CABLES (1249C SERIES)

PREMIUM 5e F/UTP PRODUCTS

GenSPEED 10 MTP Category 6A Cable An Unshielded 6A Cable with Superior Protection Against Alien Crosstalk

GIGALAN AUGMENTED CABLE CAT6A F/UTP 23AWGX4P LSZH

CATEGORY 6 CABLING SOLUTIONS

CATEGORY 6A CABLING SOLUTIONS

Bus Cables & Industrial Ethernet Cables

Table of Contents. Open Matrix System (OMS) 1-2

Mohawk Master Catalog

IBDN Plus 25-Pair Cat5 UTP Cable

Continuous Flex Data Cable

NEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

10G 6A F/UTP SYSTEM PRODUCTS 10G 6A F/UTP

Dimensions. Electrical Specifications. Environmental Specifications. General Specifications. Mechanical Specifications.

Combining Value and Performance Like No One Else

NEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables

COLORED CATEGORY 5e BULK CABLE, SOLID-CONDUCTOR PATCH CABLE, & CATEGORY 5e BACKBONE CABLE

GIGALAN CAT.6 U/UTP 23AWGx4P - LSZH (EXP)

CONTENTS. Product Guide 1. Multi Conductor Cable 11. Paired Cable 20. RS-232 Application Cable 27. RS-422 Application Cable 28

CATEGORY 6A CABLING SOLUTIONS

Frequency ASRL(db) Attenuation Max. NEXT Power Sum (MHz) Minimum db/100m db/1000ft Minimum db/100m Minimum db/100m

ACOM General Cable General Cable Canada

CATEGORY 5e CABLING SOLUTIONS

ENTERPRISE COPPER SOLUTIONS

Solarstar Electronics Industrial Co.,Ltd. 3/F,58,Junxin Rd.,Guanlan,Longhua,Shenzhen,China

PATCH CORDS, PLUGS & CABLES

Compact Module. Category 6 FTP Cabling System

Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

1 1/2 13.5, 625 JCASS)

17 Bulk Cables INSTRUMENT CABLES SS/ONE CS/535 CS/ SS/ONE SONIC SOLUTIONS HIGH DEFINITION INSTRUMENT CABLE MADE IN ITALY

Category 5e F/UTP Euroclass D ca Cables

NCB-C6SGRYR M Category 6 STP Solid Cord. Specification. Doc. Version: /09/30

DINTEK LAN Cabling Systems

Gear up for the future.

FLAT AND ROUND CABLE PRODUCT DESCRIPTION DESIGN ADVANTAGES. IDC Systems Cable

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project

FUTURE PROOF YOUR CONNECTIONS

Mining and Petrochemical Fiber Optic Cables

Cat.6 4 Pair UTP Cable

STRUCTURED CABLING SOLUTIONS

Volition TM Category 5e cable 100 Ω, FTP

BUS UNITRONIC BUS CAN

Copper Solution Contents Cabinets Fiber Optic Solution

Cables for robot applications

Magic Patch Patch Leads & Accessories

What really changes with Category 6

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

TABLE Of CONTENTS JACKET COLOR OPTIONS TABLE OF CONTENTS COMPANY INFORMATION CATEGORY 5E CABLES CATEGORY 6 CABLES CATEGORY 6A CABLES

Ethernet Series. Etherplug Etherlink V Etherlink V Specialty Connectors Specifi cations...

Siam Pacific Electric Wire & Cable Co., Ltd.

75 Ohm BNC Male Connector Crimp/Solder Attachment for PE-B159, 1855A, Mini 59

FREEDM Loose Tube Interlocking Armored Cables

Professionally Install Products Right the First Time. TOOL-CRIMP Radial Linear compression tool for BNC, F & RCA connectors

PRODUCT INFORMATION ETHERLINE PN FLEX. Info CPR: Article number choice under For Profinet applications Flexible use

10G 6A UTP SYSTEM PRODUCTS 10G 6A UTP

Detailed Specifications & Technical Data

How Wire Fails Originally presented to the Society of Motion Picture and Television Engineers Convention, Sydney, Australia, on Friday, July 4, 1997.

Premise Installation Guide

Automation. Automation. Guide for Servo Motors/Drives and BUS Systems. Make the right connection.

Our cables at: ENGLISH CHANNEL TALLIN PORT MECCA METRO PULKOVO AIRPORT

CUSTOM COLLECTION. Welcome to the Tributaries Custom Collection.

3M Supported Applications Map 100,000 (2005) Single-mode. Fiber. Multimode. Fiber. Copper

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

Instrumentation Cables

ENGINEERING COMMITTEE Interface Practices Subcommittee. ANSI/SCTE (Formerly IPS SP 001)

Data Communication Products

HomeChoice Cable. Belden HomeChoice Structured Cabling Products. The Smartest Choice For The Intelligent Home

Industrial Ethernet User Guide

LAN Cabling Systems Copper

IFS MC252-1T-1CXP and MC252-1P-1CX User Manual

CATALOGUE PRODUCT CATALOGUE CCS CONNECTIVITY & CABLING SYSTEM STRUCTURED CABLING SYSTEM. is a trademark of:

3M Mini D Ribbon (MDR) Cable Assembly

75 Ohm N Male Connector Crimp/Solder Attachment for RG6

SECTION COMMUNICATIONS HORIZONTAL CABLING

Multi-Media Installation Guide

RG-59/RG-6/RG-11 LSZH SERIES MAIN FEATURES

Power and Control T YPE BY RAVI GANATR November/December IAEI NEWS

Industry solutions: Broadcast

Drop Cable. > BrightWire > MultiReach > NEC 830 Approved Cables

TrayOptic Cables Feature Laser Certified Fiber (LCFÍ) and Water-Blocking Capability. Quality You Can Trust

D-COAX, Inc. D-COAX d086 Series Cable Pair. High Frequency, Skew Matched, Phase Stable Cable Pair (65 GHz)

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

Volition TM RJ45 K5e Jacks

Transcription:

Description: 2 AWG Bonded-Pairs solid bare copper conductors, polyolefin insulation, overall Beldfoil shield (00% coverage), industrial grade sunlight- and oil-resistant PVC jacket, drain wire, rip cord. Sequential marking at two foot intervals Usage (Overall) Suitable Applications: Industrial Ethernet Cable, Harsh Environments, MHz Category 5e, Industrial Ethernet, Gigabit Ethernet, 00BaseTX, 00BaseVG ANYLAN, 55ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio, AES5, RS-22, Noisy Environments, CMX -, RJ-5 Compatible Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material 2 Solid BC - Bare Copper Insulation Insulation Material: Insulation Material Wall Thickness (in.) PO - Polyolefin.00 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Coverage (%) Beldfoil Tape Aluminum Foil-Polyester Tape 00 Outer Shield AWG: AWG Stranding Conductor Material 2 7x32 TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Material PVC - Polyvinyl Chloride Outer Jacket Ripcord: Overall Cabling Overall Nominal Diameter: Pair Pair Color Code Chart: Number Color White/Blue Stripe & Blue 2 White/Orange Stripe & Orange 3 White/Green Stripe & Green White/Brown Stripe & Brown No 0.265 in. Mechanical Characteristics (Overall) Installation Temperature Range: -25 C To +75 C Page of

Operating Temperature Range: Bulk Cable Weight: Max. Recommended Pulling Tension: Bend Radius (Install)/Minor Axis: -0 C To +75 C 32 lbs/000 ft. 35 lbs. 0.500 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMR,, UL CEC/C(UL) Specification: CMR Other Standards: 80 Category 5 EU Directive 0/53/EC (ELV): EU Directive 2/95/EC (RoHS): EU RoHS Compliance Date (mm/dd/yyyy): 0/0/ EU Directive 2/96/EC (WEEE): EU Directive 3//EC (BFR): CA Prop 65 (CJ for Wire & Cable): MII Order #39 (China RoHS): PMSHA Specification: Telecommunications Standards: Other Specification: Flame Test UL Flame Test: CSA Flame Test: Suitability Suitability - : Sunlight : Oil : Plenum/Non-Plenum Plenum (Y/N): Plenum Number: Non-Plenum Number: P-07-KA060003 568-B.2 Category 5e NEMA WC-63. Category 5e, UL verified to Category 5e UL666 Riser FT No 533P 533R Electrical Characteristics (Overall) Nom. Mutual Capacitance: Capacitance (pf/ft) 5 Nominal Velocity of Propagation: VP (%) 70 Maximum Capacitance Unbalance (pf/00 m): 330 Maximum Delay: Delay (ns/00 m) 538 @ 00MHz Max. Delay Skew: Delay Skew (ns/00 m) 5 Page 2 of

Maximum Conductor DC : DCR @ 20 C (Ohm/00 m) 9.38 Max. Operating Voltage - UL: Voltage 300 V RMS Maximum DCR Unbalanced: DCR Unbalance @ 20 C (%) 3 Electrical Characteristics-Premise (Overall) Premise Cable Electrical Table : Freq. (MHz) Max. Attenuation 00 m) NEXT (db) PSNEXT (db) ACR (db) PSACR (db) Min RL (db) SRL (db) 65.3 63.0 60.0 23. 56.3 5.0 9.0 23.0 23.0 8 5.8 5.8 8.8 6.0 3.0 2.5 2.5 0 50.3 3.0.0 6 39.0 36.0 20 9.3 5.8 2.8 3 33.5 25 0..3 33.9 2.3 2.3.7 2.9 3.0 28.0 38. 35. 2 9.0 2.5 2.5 00 2 35.3.0.0 20. 20. 32. 27.8.0 5.0 Premise Cable Electrical Table 2: Freq. (MHz) Input (Unfitted) Imp. (Ohms) Fitted Impedance ELFEXT (db) PSELFEXT (db) 00 ± 5 00 ± 5 63.8 00 ± 5 00 ± 5 5.7 8.7 8 00 ± 5 00 ± 5 5.7 2.7 0 00 ± 5 00 ± 5 3.8 6 00 ± 5 00 ± 5 39.7 20 00 ± 5 00 ± 5 37.7 3.7 25 00 ± 5 00 ± 5 35.8 32.8 00 ± 5 00 ± 5 33.9 00 ± 5 00 ± 5 27.8 00 00 ± 5 00 ± 5 23.8 00 ± 25.7 Notes (Overall) Notes: US Patent #'s 5, 606, 5; 5, 73, 26. Operating temperatures are subject to length de-rating. Cable passes -0C Cold Bend per UL 58. Put Ups and Colors: Item # Putup Ship Weight Color Notes Item Desc 7929A 006000,000 FT 37.000 LB BLUE, LIGHT C PR #2 PP FS PVC 7929A 00000,000 FT 37.000 LB BLACK C PR #2 PP FS PVC 7929A 000 2,000 FT 700 LB BLACK C PR #2 PP FS PVC Notes: C = CRATE REEL PUT-UP. Page 3 of

INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 8.7 Industrial Data Solutions Industrial Ethernet DataTuff Twisted Pair and TrayOptic Fiber Optic Cables Overview The reliability of your industrial Ethernet network depends on the cable infrastructure. Data transmission errors can lead to interruptions in critical control functions resulting in lost production time and even safety issues. Belden s family of industrial Ethernet cables is designed to withstand the rigors of industrial environments. Whether it s exposure to oil and sunlight, temperature variation, abrasion and crushing, or the presence of electromagnetic interference (EMI) or radio frequency interference (RFI), turn to Belden for the solution. Belden offers an extensive line of high performance cables in both copper constructions with DataTuff cables as well as fiber optic designs with TrayOptic cables. Performance Assurance from Blue Hose to Industrial Ethernet To assist you in achieving optimum network performance, Belden has built quality and reliability into each cable it manufactures. Decades of leadership and experience in supplying reliable high-end cable solutions, such as Blue Hose, to industrial networks and control systems are combined to give you industrial Ethernet cables that perform to maximum network capability. Our dedication to quality manufacturing practices and processes assures consistent products of uncompromising quality. Installable Performance with Patented Bonded-Pair Technology Belden s Bonded-Pair versions of DataTuff cables are unique in the industry to give you an Installable Performance advantage. This patented design yields superior electrical performance even after the effects and stresses of pulling, twisting and bending during typical installations. This performance advantage is achieved by bonding the individual insulated conductors along their longitudinal axes, resulting in uniform conductor-to-conductor spacing and the elimination of gaps between conductors that can occur during installation. This is a critical construction feature because non-uniform conductor spacing and gaps change the physical characteristics of the cable such that the electrical performance of the cable suffers. Only Bonded-Pair cables deliver the electrical integrity you demand. TrayOptic Cables Belden TrayOptic cables are a line of indoor/outdoor fiber optic cables designed to meet the demanding requirements of industrial applications. When the installation demands the combination of sophisticated fiber optic technology and rugged durability, turn to Belden. DataTuff Industrial Ethernet Cable Selection Guide Part Shielding of Pairs Unshielded Shielded * Solid Conductor Stranded ** Installation Installation Stress Pull Tension Oil UV Sunlight Environmental Issues CMX/ Underground (burial) Gasoline Hi/Lo Temp Industrial Grade Jacket Heavy Upjacket Armored Category 5e Cable u 7932A 2 20 u 7933A 2 20 7923A 0 798A 35 792A 0 u 7930A 25 u 7922A 0 PLTC u 793A 0 7928A 0 700A 0 u 700A2 0 Oil Res I&II 2700A 0 u 2700R 0 7929A 35 799A 25 792A 75 Category 6 Cable 7927A 5 793A 0 872A 5 2872A 5 *Shielded products are recommended for high-noise environments. **Stranded products are recommended where more flexibility is needed. Products with Bonded-Pair technology provide Installable Performance advantages refer to Belden s Bonded-Pair Cable Bulletin #BP02 EtherNet/IP is a trademark of ControlNet International, Ltd. under license by Open DeviceNet Vendor Association, Inc. 8 Industrial Cables

INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 8.9 Industrial Data Solutions Industrial Ethernet Category 5e DataTuff Twisted Pair Cables, 2-Pair and -Pair Heavy-Duty Sunlight and Oil-Resistant Jackets Description Part UL NEC/ C(UL) CEC Type of Pairs Standard Lengths Enhanced Cat 5e 22 AWG Bonded-Pairs Solid Bare Copper Conductors Rip Cord See Color Code Chart (below) Polyolefin Insulation.030 Industrial Grade Sunlight- and Oil-resistant Black PVC Jacket PLTC 7922A NEC: 000 30.8 6.3.30 7.65 u PLTC, 0 609.6 92.5 CMR, CMR FT Rip Cord Cable passes -25 C Cold Bend per UL58 Installation Temperature: -0 C to +75 C Operating Temperature: -25 C to +75 C** Jacket sequentially marked at 2 ft. intervals Third party verified to TIA/EIA-568-B.2, Category 5e U.S. Patents 5,606,5 and 5,73,26 Ft. m Standard Unit Wt. Nominal OD Lbs. kg Inch mm Freq. (MHz) 8 0 6 25 00 55 250 350 Max. Atten. 00m).0 5.7 6. 8. 0.3.6 6.8 2.7 27.7 3 36. NEXT (db) 65.3 56.3 5.8 50.3 2.9 38. 35.3 32.5 30.8 29.3 27.2 ACR 00m) 63.3 52.3 6. 3.9 39. 3. 3.3 2.6 7..7 3.0 ELFEXT 00m) 8.7 2.7 32.8 6.9.7 2.8 9.9 Input Imped. (Ω) 00±8 00±20 00±20 00±22 RL (db) 23.0 2.5 2.3 2.5 20. 9.0 9.0 8.0 Enhanced Cat 5e 2 AWG Bonded-Pairs Stranded (7x32) TC Conductors See Color Code Chart (below) Polyolefin Insulation.030 Industrial Grade Sunlight- and Oil-resistant PVC Jacket (Black, Red or Teal) Stranded 792A NEC: 000 30.8 30.0 3.6.22 Flexible CMR, 0 609.6 58.0 26.3 CMR FT 0 ft. put-up available in Black only. RJ-5 Compatible Jacket sequentially marked at 2 ft. intervals Cable passes -0 C Cold Bend per UL58 Installation Temperature: -25 C to +75 C Operating Temperature: -0 C to +75 C** Third party verified to TIA/EIA-568-B.2, Category 5e U.S. Patents 5,606,5; 5,73,26 and 5,763,823 8 0 6 25 00 55 250 350 2..8 6.8 7.7 9.7 2. 3.9 20.2 33.2 38. 3.7 53.2 65.3 56.3 5.8 50.3 2.9 38. 35.3 32.5 30.8 29.3 27.2 62.9 5.5 5.0 2.6 37.5 3.9 29.0 8.3 9.2 8.7 2.7 32.8 6.9.7 2.8 9.9 00±8 00±8 00±20 00±20 00±22 25. 25.5 9.0 9.0 8.0 Enhanced Cat 5e 2 AWG Bonded-Pairs Solid BC Conductors Overall Beldfoil Shield (00%) See Color Codes (below) Polyolefin Insulation.030 Industrial Grade Sunlight- and Oil-resistant PVC Jacket (Black, Red or Teal) Compliant 7933A NEC: 2 000 30.8 3.5.227 5.77 u CMR 0 609.6 6.8 29. Shielded CMR FT 0 ft. put-up available in Black only. M-2 or RJ-5 Compatible Shield is bonded to jacket inner wall for electrical stability. Cable passes -0 C Cold Bend per UL58 Installation Temperature: -25 C to +75 C Operating Temperature: -0 C to +75 C** Jacket sequentially marked at 2 ft. intervals Third party verified to TIA/EIA-568-B.2, Category 5e U.S. Patents 5,606,5 and 5,73,26 Polyolefin Insulation.030 Industrial Grade Sunlight- and Oil-resistant PVC Jacket (Black or Blue) Shielded 7929A NEC: 000 30.8 37.0 6.8.265 6.73 CMR, 0 609.6 7 32.7 CMR FT 0 ft. put-up available in Black only. RJ-5 Compatible Shield is bonded to jacket inner wall for electrical stability. Cable passes -0 C Cold Bend per UL58 Installation Temperature: -25 C to +75 C Operating Temperature: -0 C to +75 C** Jacket sequentially marked at 2 ft. intervals Third party verified to TIA/EIA-568-B.2, Category 5e U.S. Patents 5,606,5 and 5,73,26 P-07-KA060003-MSHA* 0 6 00 0 6 00..7 2 32...7 2 32. 35. 27.8 35. 27.8 9.2 36. 2 8. 0.3.0 9.2 36. 2 8. 0.3.0 8.7.7 8.7.7 00±25 00±25 5.0 23.0 2.5 20. 5.0 Enhanced Cat 5e 2 AWG Bonded-Pairs Solid BC Conductors Overall Beldfoil (00%) + TC Braid Shield (70% Coverage) Polyolefin Insulation.030 Industrial Grade Sunlight- and Oil-resistant PVC Jacket (Black, Red, Blue or Teal) 792A NEC: 000 30.8 55.0 2.9.330 8.38 Compliant CMR, 0 609.6 06.0 8. Heavy-shielded CMR FT 0 6 00..7 2 35. 9.2 36. 2 8. 0.3 8.7 0 ft. put-up available in Black only. 2 AWG solid spiral drain wire. Cable passes -0 C Cold Bend per UL58 Installation Temperature: -25 C to +75 C Operating Temperature: -0 C to +75 C** Jacket sequentially marked at 2 ft. intervals Third party verified to TIA/EIA-568-B.2, Category 5e NEMA WC-63. Category 5e U.S. Patents 5,606,5 and 5,73,26 ACR = Attenuation Crosstalk Ratio AL = Aluminum BC = Bare Copper ELFEXT = Equal Level Far-end Crosstalk NEXT = Near-end Crosstalk = Power Sum RL = Return Loss TC = Tinned Copper EtherNet/IP is a trademark of ControlNet International, Ltd. under license by Open DeviceNet Vendor Association, Inc. *Pennsylvania Department of Environmental Resources and United States Mine Safety and Health Administration Certification. **Subject to length de-rating. DataTuff Color Codes: Pair = White/Blue Stripe & Blue, Pair 2 = White/Orange Stripe & Orange, Pair 3 = White/Green Stripe & Green, Pair = White/Brown Stripe & Brown For two pair products: use color codes for Pairs 2 & 3 8 Industrial Cables