Owner s Manual & 1802-EPD (Electronic Programmable Directory) Telephone Entry Systems

Similar documents
Owner s Manual. 1802, 1803, 1808, 1810 Telephone Entry Systems

User Guide. Centrex Recording Interface

TAC1 Telephone Entry System

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

FlexiScan. Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL

MP-7424 Football Scoreboard with MP5000 Console

Miniguard HF-2 with Prox Reader or TELEPROX

By CHANNEL VISION. Flush Mount Amplifier A0350

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

innkeeper LTD Digital Hybrid User Guide JK Audio

VNS2200 Amplifier & Controller Installation Guide

Battery Operated Controllers

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Colour Explosion Proof Video Camera USER MANUAL VID-C

Installation Instructions

TeleHawk Door entry system

INSTALLATION INSTRUCTIONS FOR

9216e. Installation and User Guide

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

Concord 4 GSM Module Installation Sheet

Manual No: Revision: D. IQ Box. Software Upgrade Instructions

ImproX SupaGate 4-Channel Controller INSTALLATION MANUAL

Electric Motorized Projection Screen PowerMax Tension Series

Digital Feedback Eliminator

US Rev. E, Copyright 1 September 2008 CAUTION:

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

Site Installation Model MP-8424

WDK-2500-STROBE. User Guide

SQM40/41 Actuators for air and gas dampers

In-Line or 75 Ohm In-Line

Site Installation Model MP-8433

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

ST8-WiFi Timer. Installation Guide and Operations Manual. English MIN M D YYYY

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

Warner Photoscanner MCS-500 Series LED Photoelectric Control

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Scale Track System. 21 Century y Signal System 2-Rail Manual

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

IL591 SECTION D Rev /2011. Tek-SAFE NC150R Area of Rescue Assistance System. Operation, Installation and Service Manual

OPERATOR S MANUAL MICRO SEVEN, INC MODEL LS15-C1 TELEPHONE LINE SIMULATOR

For use with QED and hardwired control panels ONLY!

FTC AGL System Controller Reference Manual Part Number

Cellular Signal Booster

VALCOM HANDSFREE TALKBACK PAGING SYSTEM DESIGN/INFORMATION

Operation Manual. Model MCS350. Modular Communication System. Document No (01)

AES Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter

Installation Manual SaVi Note Underwater LED Light

EZ Pro Jr. Installation and Programming Guide For EZ Pro TM Jr. models:

Junior Max (JR Max ) Controller

Power Injector 1520 Series

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

MclNTOSH MODEL C-4 and C-4P

Userfriendly Guide. For use with BT s Caller Display and Call Waiting Select Services

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

DISTRIBUTION AMPLIFIER

A0304 A0304. Audio Out. Audio In. 15 VDC IR In. IR In A0304. Audio & IR Control CAT5 Transceiver

ROUGH DRAFT. Guide. Installation. Signal Booster. Wilson. AG Pro 75 Smart Technology In-Building Wireless 800/1900 Signal Booster.

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

2002 Martin Professional A/S, Denmark.

DC162 Digital Visualizer. User Manual. English - 1

Installation & User Manual For. Styluscom. Wired Video Intercom System. Models StylusAB, StylusABK, StylusAS Manual Version 1.

DS1 Cross-Aisle Panel

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

TDEPD. Field-Programmable Pressure Switch/Transducer with Integrated LED Display. Programming Sequence Manual

Scoreboard Operator s Instructions MPCX SCD / DGT / Pitch Time Control

Rain+Birdt. Landscape Irrigation & Maintenance Remote System. Quick Start Guide 4.00 F G H K 9X. c n. System Components

EZCOM-1. PLC - to - AMS MESSAGE DISPLAY INTERFACE INSTALLATION AND OPERATING INSTRUCTIONS. Rev March, 2001

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

GAUGEMASTER PRODIGY EXPRESS

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

ULTRA-TRAC APL INSTRUCTION MANUAL. Read and understand instructions before use. Patented. 851 Transport Drive Valparaiso, IN

Tech Support: Customer Service: General Tech Questions: Tech Docs:

USER MANUAL Full HD Widescreen LED Monitor L236VA

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

Electric Wall/Ceiling Projection Screen Saker Tab-Tension Series User s Guide

AB-114 / AB-202 AB-404 / AB-301 AB-T2454 Multi-room audio distribution system AB-202

DP1 DYNAMIC PROCESSOR MODULE OPERATING INSTRUCTIONS

Electronic 1-Circuit 7-Day Time Switch With 100-Hour Backup

PSM-003. Micro Polarization Controller/Scrambler. User Guide

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

VNS2210 Amplifier & Controller Installation Guide

USER S MANUAL (1/2) (Functions and connections)

Starling Tab-Tension 2 Series

Designed in Colorado, USA. Bluetooth Cable. Quick Start Guide

Rebis Audio Ltd. RA226 Digital Sampler User Guide

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

How do I delete a. Remove Here

AN2 Series. 900tvl. CMOS Technology High Resolution Sensor. elinetechnology.com P/N 01.BSM V1.0

Electric Wall/Ceiling Projection Screen Saker Plus Series User s Guide

INSTALLATION & USER GUIDE

USER MANUAL Full HD Widescreen LED Monitor L215IPS

Caution. Hanging the Screen:

Transcription:

Owner s Manual 1802 & 1802-EPD (Electronic Programmable Directory) Telephone Entry Systems DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 1802-065 REV D, 8/08 Copyright 2006 DoorKing, Inc. All rights reserved.

Page 2 1802-065-D-8-08

Use this manual with the following models only. 1802 and 1802-EPD Telephone Entry Systems with circuit board 1862-010, Rev L or higher. DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights reserved. No portion of this manual may be copied, reproduced, translated, or reduced to any electronic medium without prior written consent from DoorKing, Inc. NOTE: The log tables and resident instruction sheet (pages 50-53) may be copied as needed. 1802-065-D-8-08 Page 3

Page 4 1802-065-D-8-08

QUICK START 1 Mount the Telephone Entry System. If the unit is being used to provide access through an automated vehicular gate, the unit must be mounted at least 10-feet away from the gate. See pages 11-13. 2 Connect 16 VAC power to terminals 13-14. Connect a dedicated touch-tone loop-start phone line to terminals 1-2. Connect ground wire to terminal 3. See pages 19-20. 3 Connect device(s) to be activated (gate operator, door strikes, etc.) to relay terminals as required. See pages 19-20. 4 5 Program a MASTER CODE ( Section 3.1.1) - Factory Default is 9999 1. Open the cabinet and turn the Master Code switch ON. 2. Enter a four-digit Master Code on the keypad and then press *. 3. Turn the Master Code switch OFF. Set the DIRECTORY CODE Length ( Section 3.2.1) - Factory Default is 3-digits 1. Press *20 and enter the Master Code. 2. Enter the desired Directory Code length (1-2-3 or 4 digits) then press *. 6 Program Phone Numbers ( Section 3.2.2) 1. Press *01 and enter Master Code. 2. Enter a Directory Code then press *. 3. Enter a 7-digit Phone Number then press *. 4. Repeat 2-3 to enter more numbers. 5. Press 0# TOGETHER when finished. 7 Adjustments ( Section 2.4) 1. Make a phone call. 2. Adjust microphone volume**, speaker volume and feedback. 3. Have tenant press 9 to open door or gate. ** Rev H boards and higher only. 1802-065-D-8-08 Page 5

Table of Contents Important Notices...8 Important Information...9 Features...10 Section 1 Installation 1.1 Installation Guidelines...11 1.2 Surface Mount...12 1.3 Flush Mount...13 1.4 Flush Mount Rough-in Box...14 1.5 Memory Chip Installation...15 1.6 Postal Lock Installation...16 Section 2 Wiring & Adjustments General Information...17 2.1 Circuit Board Adjustments...18 2.2 Wiring Diagram...19 2.3 Main Terminal Description...20 2.4 Adjustments 2.4.1 Speaker Volume...21 2.4.2 Microphone Volume...21 2.4.3 Feedback...21 2.4.4 Click Sensitivity...21 2.4.5 Display Contrast...21 2.4.6 Master Code Switch...22 2.4.7 Ring Pin...22 2.4.8 Handset / Hands Free...22 Section 3 Programming General Information...23 3.1 General Programming 3.1.1 Master Code...24 3.1.2 Single or Multiple Systems...24 3.1.3 Relay Strike Time...24 3.1.4 Open Tone On or OFF...24 3.1.5 Talk Time...25 3.1.6 Tone Open Numbers...25 3.1.7 Touch-tone / Rotary-dial...25 3.1.8 Programming Switch Inputs to Activate a Relay or Dial-Out a Phone Number...26 3.1.9 Number of Rings to Answer...26 3.1.10 PBX Line Access Code programming...26 3.1.11 Star (*) Key Function...26 3.1.12 Keypad Function...27 3.1.13 System Stay On Line after Touch Tone...27 3.1.14 Automatic Hang-up...27 3.2 Phone Number Programming 3.2.1 Directory Code Length...28 3.2.2 7-Digit Phone Numbers...28 3.2.3 Area Codes...29 3.2.4 Phone Numbers with Area Code Reference...29 3.2.5 Deleting Individual Phone Numbers...29 3.2.6 Delete All Phone Numbers...30 3.2.7 Display / Delete Phone Numbers...30 3.2.8 Display Phone Numbers with Known Directory Code...30 Page 6 1802-065-D-8-08

3.3 Programming Messages and Names (1802-EPD only) 3.3.1 Programming Letters and Numbers...31 3.3.2 Programming the Welcome Message...32 3.3.3 Reset the Welcome Message to Default...32 3.3.4 Programming the Instruction Message...33 3.3.5 reset the Instruction Message to Default...33 3.3.6 Programming Names...34 3.3.7 Delete a Single Name...35 3.3.8 Delete ALL Names...35 3.4 Entry Code Programming 3.4.1 Four-Digit Entry Code Programming...36 3.4.2 Delete Individual Four-Digit Entry Codes...36 3.4.3 Delete All Four-Digit Entry Codes...36 3.4.4 Four-Digit Entry Code Divide Number...36 3.4.5 Five-Digit Entry Code Programming...37 3.4.6 Delete Individual Five-Digit Entry Codes...37 3.4.7 Delete All Five-Digit Entry Codes...37 3.4.8 Five-Digit Entry Code Divide Number...37 3.5 Time Functions Programming 3.5.1 Time Clock Programming...38 3.5.2 Automatic Relay Activation Time Zones...38 3.5.3 Four-Digit Entry Code Time Zone...39 3.5.4 Five-Digit Entry Code Time Zone...39 3.5.5 Flash Entry Codes...40 Section 4 Operating Instructions 4.1 General Instructions 4.1.1 Guest Instructions...41 4.1.2 Responding to a Guest Call...41 4.1.3 Using Entry Codes...41 4.2 System Administrator 4.2.1 Remote Programming...42 4.2.2 Remote Relay Activation...42 4.2.3 Relay Check...42 4.2.4 Entry Code Time Zone Enable / Disable...43 4.2.5 Auto Relay Activation Time Zone Enable / Disable...43 4.3 Miscellaneous Operating Instructions 4.3.1 Switch Input Operation...44 4.3.2 Talk Time...44 4.3.3 Line Sharing...44 4.3.4 Connection to a PBX...45 4.3.5 10-digit Dialing...45 Section 5 Maintenance and Trouble Shooting 5.1 Replacement Parts...47 5.2 Trouble Shooting...47 5.3 Accessories...49 5.4 Log Tables...50 Resident Data Sheets...51 Resident Instruction Sheet...53 1802-065-D-8-08 Page 7

Important Notice FCC United States This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC Rules and Regulations. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Registration Number: DUF6VT-12874-OT-T DOC - Canada The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department does not guarantee the equipment will operate to the users satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable means of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure, for their own protection, that the electrical ground connections of the power utility, telephone lines, and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. DOC Registration Number: 1736 4528 A Notice: The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the sum of the load numbers of all the devices does not exceed 100. Notice: DoorKing does not provide a power transformer on units sold into Canada. Use only transformers that are CSA listed to power the telephone entry system. 1802, 1803, 1808, 1810, 1814, 1815, 1818 and all "P" series systems require a 16.5-volt, 20 VA transformer. The models 1816 and 1817 require a 16.5-volt, 40 VA transformer. The model 1812 requires a 24-volt, 20 VA transformer. Listing: This product has been tested to and found to be in compliance with the U.L 294 Safety Standard by Intertek Testing Services NA Inc. (a Nationally Recognized Testing Laboratory) and is ETL listed. Page 8 1802-065-D-8-08

Important Information Prior to beginning the installation of the telephone entry system, we suggest that you become familiar with the instructions, illustrations, and wiring guidelines in this manual. This will help insure that you installation is performed in an efficient and professional manner. The proper installation of the telephone entry panel is an extremely important and integral part of the overall access control system. Check all local building ordinances and building codes prior to installing this system. Be sure your installation is in compliance with local codes. When used to control a door or pedestrian gate, try to locate the telephone entry system as near as possible to the entry point. The unit should be mounted on a rigid wall to prevent excessive shock and vibration from closing doors or gates. Continuous vibration and shock from slamming doors or spring-loaded pedestrian gates will damage the circuit board. Under no circumstances should the unit be mounted directly to a moving door or gate. ADA mounting requirements for door control. The mounting of the unit shall be in such a way that the LCD display is positioned so that it is readily visible to and usable by a person sitting in a wheelchair with an approximate eye level of 45 inches and shall comply with the following requirements: 1. If mounted vertically or tipped no more than 30 degrees away from the viewer, the center line of the LCD shall be located a maximum of 52 inches above grade. 2. If the clear floor space allows only forward approach to the system, the maximum high forward reach allowed is 48 inches above grade to the top of the keypad. 3. If the high forward reach to the system is over an obstruction of greater than 20 inches but less than 25 inches, the maximum high forward reach allowed is 44 inches above grade to the top of the keypad. 4. If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach shall be 54 inches above grade to the top of the keypad. 5. If the high side reach is over an obstruction of 24 inches or less, the maximum high side reach allowed is 46 inches above grade to the top of the keypad. When used to control a vehicular gate with an automatic gate operator, the telephone entry system must be mounted a minimum of ten (10) feet away from the gate and gate operator, or in such a way that a person cannot operate the entry system and/or touch the gate or gate operator at the same time. Be sure that the system is installed so that it is not directly in the traffic lane. Goose neck mounting post and kiosks work well for these type systems. When planning where to locate the system, take into consideration traffic lane layouts, turn around lanes for rejected access, conduit runs, power availability, etc. Environmental factors must also be taken into account. Surface mount units are designed for direct outdoor installations, however it is preferable to protect them from direct exposure to driven rain or snow whenever possible. Flush mount and wall mount units must be protected from direct exposure to the elements. Be sure that ample lighting is provided so that guest can read both the directory and the operating instructions at night. This telephone entry system contains a number of static sensitive components that can be damaged or destroyed by static discharges during installation or use. Discharge any static prior to removing the circuit board from the lobby panel by touching a proper ground device. Instruct the end user to read and follow these instructions. Instruct the end user to never let children play with or operate any access control device. This Owner s Manual is the property of the end user and must be left with them when installation is complete. 1802-065-D-8-08 Page 9

Features 1802-EPD has a built-in electronic directory using a 16-character LCD display. Simple to use A and Z scroll buttons - Big CALL button to simplify use (EPD model only). 1802 can provide service for up to 1000 residents. 1802-EPD provides service for up to 100 residents. 1802 and 1802-EPD are programmed from the front keypad. 1802 can be programmed remotely using a touch-tone telephone. System keypad will emit DTMF tones after a call is answered allowing the system to be used with auto-attendants, answering machines, etc. Directory codes can be set from 1 to 4 digits in length and can be randomly assigned. 15 programmable area codes allow the system to be used in areas requiring 10 and 11-digit dialing. Two internal relays allow the system to control a main entry point plus an additional entry point. Built in time clock provides hold open time zones, entry code time zones and Flash entry codes. 5-digit entry codes available for special needs. Programmable switch inputs can be set to activate a relay or to dial a preprogrammed phone number. Page 10 1802-065-D-8-08

SECTION 1 - INSTALLATION Order your telephone line at least two weeks prior to the planned installation date. This will assure that a phone line is available when the unit is installed. The telephone company will require the following information from you: Type: Ringer Equivalence: Jack Type: FCC Registration (US): DOC (Canada): Electrical Listing: Touch Tone, Loop Start 0.0 A RJ11C DUF6VT-12874-OT-T 1736 4528 A Complies with U.L. 294 - ETL Listed CALLER ID: You may want to consider ordering caller ID blocking from the telephone company for the entry system phone line. Without caller ID blocking, tenants with the proper phone equipment will be able to identify the telephone number that the entry system is installed on. This may or may not be desirable. 1.1 Installation Guidelines 1. Open the cabinet of the telephone entry system and disconnect the keypad ribbon cable from the main circuit board. 2. Remove the 6-32 x 1/2 round head screws from the upper corners of the circuit board. 3. Remove the circuit board by gently pulling it out of the main terminal edge connector. CAUTION - the circuit board contains static sensitive components. Discharge any static electricity from your hands by touching a proper ground device before removing the circuit board. Place the circuit board where it will not be damaged. 4. Mount the cabinet of the telephone entry system. Be sure that mounting screws do not protrude into the cabinet where they could cause a short on the back of the circuit board. Make any necessary conduit connections. 5. Route wiring into the cabinet. Do not apply any power at this time. 6. Clean out the cabinet. Be sure that all dirt, metal and/or wood debris is removed from the cabinet and that the terminal strip edge connector is clean and free of any loose particles. 7. Re-install the circuit board into the cabinet by gently pushing the circuit board terminals into the edge connector. CAUTION - the circuit board contains static sensitive components. Discharge any static electricity from your hands by touching a proper ground device before removing the circuit board. 8. Secure the circuit board to the cabinet using the screws removed in step 2. 9. Plug the keypad ribbon cable into the circuit board. The cable points down. WARNING! If this entry system is used to control a vehicular gate with an automatic gate operator, the entry system must be mounted a minimum of ten (10) feet away from the gate and gate operator, or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time. 1802-065-D-8-08 Page 11

1.2 Surface Mount Only Surface mount units can be mounted directly to a wall or pilaster, or can be post mounted using a DoorKing mounting post (p/n 1200-045 and 1200-046). Be sure the unit is mounted securely and is not subject to vibration from closing doors or gates. WARNING! If this entry system is used to control a vehicular gate with an automatic gate operator, the entry system must be mounted a minimum of ten (10) feet away from the gate and gate operator, or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time. 1802 Surface Mount Housing 5.0 12.875 D.875.875 D 6.50 1.75 1.75 3.375 1.625 DOORKING, INC., INGLEWOOD, CA 90301 Title: Date: 1802 Surface Mount Case 9/03 Dwg. No. M1800-065-9 Rev. A Page 12 1802-065-D-8-08

1.3 Flush Mount Only The 1802 flush mount unit can be used in outdoor applications. The 1802 rough-in box (page 21) is included with the 1802 flush system. Be sure the unit is mounted securely and is not subject to vibration from closing doors or gates. WARNING! If this entry system is used to control a vehicular gate with an automatic gate operator, the entry system must be mounted a minimum of ten (10) feet away from the gate and gate operator, or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time. 1802 Flush Mount Housing 3.25 14 12.875 D 8.375 1.75.875 D 1.625 DOORKING, INC., INGLEWOOD, CA 90301 Title: Date: 1802 Flush Mount Case 5/05 Dwg. No. M1800-065-13 Rev. A 1802-065-D-8-08 Page 13

1.4 Flush Mount Rough-in Box The flush mount rough-in box simplifies flush mount installations. 1802 Flush Mount Rough-in Box 12.5 1.25D 1.25 3.0 6.875 3.375 1.75 DOORKING, INC., INGLEWOOD, CA 90301 Title: Date: 1802 Flush Mount Rough-in Box 5/05 Dwg. No. M1800-065-14 Rev. A Page 14 1802-065-D-8-08

1.5 Memory Chip Installation The telephone entry system is shipped with a memory chip packaged in a separate box inside the shipping container. The memory chip must be installed for the telephone entry system to operate. Note: This section does not apply to the 1802-EPD model, which is shipped with the memory chip installed. CAUTION!! Do not install the memory chip with power to the telephone entry system turned on. Attempting to install the memory chip with power on will irrevocably damage the chip. CAUTION!! The memory chip is a static sensitive component. Discharge any static electricity from your hands by touching a proper ground device before removing the control board. Handle the memory chip with care. 1. The large memory chip socket is colored blue and is located on the right hand side of the circuit board. Be sure that the handle is in the un-locked position (towards the left). Be sure that power to the telephone entry system is off. 2. Carefully insert the memory chip into the socket. The small half circular indentation on the chip must be at the top. CAUTION: Installing the memory chip upside down will cause permanent damage to the chip. Be sure that the memory chip is seated correctly in the socket. 3. Move the lever on the chip socket to the locked position (towards the right). 1802-065-D-8-08 Page 15

1.6 Postal Lock Installation At some locations, such as gated communities, it will be necessary to provide access to the mail carrier so that they can deliver the mail. Mail carrier access will be provided by the installation of an Arrow Postal Lock. This is the same lock that the Post Office uses for gang mailboxes. These locks are not available to the public. The installer or the building owner/manager will have to call the Post Office and arrange for the installation of this lock into the telephone entry system. Prior to installation of the postal lock, be sure power to the telephone entry system is turned off. 1. Remove the hole plug on the faceplate of the telephone entry system. 2. Cut the wire tie wrapped around the micro switch next to the postal lock access hole. 3. Remove the two hex nuts from the postal lock-mounting studs. Mount the postal lock on the two studs and secure with the hex nuts. When the lock is installed, check to be sure that the pawl of the lock, in its extended position, is depressing the micro switch (the micro switch is wired normally closed). When the mail carrier inserts his key and turns the postal lock, the pawl is withdrawn and the micro switch will activate the relay that has been programmed for this function for the programmed strike time. Postal Lock Installation Detail Common to Terminal 8 Normally Closed to Terminal 4 1 3 2 4 1 Micro-switch is wired Normally Closed. Switch is held open by tie-wrap or postal lock. 2 Cut tie-wrap only if postal lock is installed. 3 Micro-switch is pre-wired. Controller terminals are shown for clarification only. 4 Postal lock supplied by others. Title: Date: DOORKING, INC., INGLEWOOD, CA 90301 Postal Lock Installation Detail 3/03 Dwg. No. M1800-065-8 Rev. A Page 16 1802-065-D-8-08

SECTION 2 WIRING & ADJUSTMENTS Prior to installing wiring to the telephone entry system, we suggest that you become familiar with the instructions, illustrations, and wiring guidelines in this manual. This will help insure that you installation is performed in an efficient and professional manner. The wiring of the telephone entry panel is an extremely important and integral part of the overall access control system. Use proper wire for the communication line, power wires, and be sure that the system is properly grounded. Check all local building ordinances and building codes prior to installing this system. Be sure your installation is in compliance with National Electric and local building codes. WARNING! If this telephone entry system is used to control a vehicular gate with an automatic gate operator, the telephone entry system must be mounted a minimum of ten (10) feet away from the gate and gate operator or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time. If this unit has not been installed in compliance with these instructions, do not proceed with any wiring until the unit has been moved and re-installed in accordance with these instructions. Use only the supplied transformers (or U.L. listed equivalent) to power the telephone entry system (16.5 VAC, 20 VA, 60 Cycle). Do not connect the power transformer to a receptacle controlled by a switch. Do not power any other devices (electric strikes, magnetic locks, etc.) from this power transformer. For wire runs up to 100 feet, use 18 AWG, 600 volt insulated wire. For wire runs up to 200 feet, use 16 AWG, 600 volt insulated wire. Power wires are susceptible to noise and hum pickup; therefore it is preferable that you keep power wire runs as short as possible. This telephone entry system contains a number of static sensitive components that can be damaged or destroyed by static discharges during installation or use. Discharge any static prior to removing the circuit board from the lobby panel by touching a proper ground device. Proper grounding of this system is a requirement. The use of surge suppressers can significantly reduce the chance of component failure because of static charges or surges. To be effective, ground connections should be made with a minimum 12 AWG, 600 volt insulated wire to a ground point within 10 feet of the telephone entry system. The ground point must be at an electrical panel, a metallic cold water pipe that runs in the earth, or a grounding rod driven at least ten (10) feet into the soil. Be sure that you use proper wire that has an insulation rated for an underground environment. All wires should be placed in conduits. Proper pre-planning can greatly ease the installation and wiring of this system. Always check with the local building code to determine the type of wire required in your municipality. 1802-065-D-8-08 Page 17

2.1 Circuit Board Adjustments 1862-010 Control Board Adjustments CONTRAST DISPLAY MIN MAX SWITCH 2 INPUT 2 3 A-Z-CALL BUTTON CONNECTOR ON Master Code OFF CLICK SENS MIN MAX KEYPAD CONNECTOR 1 MIC VOLUME MIN MAX FEEDBACK SPEAKER VOLUME MIN MAX RING PIN TONE ON 2 2 MIN TONE OFF HANDSET MAX HANDS FREE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 REV H Boards and later. 2 REV I Boards and later. RELAY 2 TERMINALS 3 Used on 1802-EPD model only. N.O. N.C. COM DOORKING, INC., INGLEWOOD, CA 90301 Title: Date: 1862 Control Board Adjustments 8/06 Dwg. No. M1800-065-12 Rev. C Page 18 1802-065-D-8-08

2.2 Wiring Diagram Field Wire Diagram - 1862-010 Control Board Gate Operator Strike / Mag Lck 3 Lock Pwr 2 7 8 1 2 SWITCH 2 INPUT 1862-010 Circuit Board NO NC COM MAIN TERMINAL 1 2 3 4 5 6 7 8 9 RELAY 2 CONTACTS 10 11 12 13 14 Phone Line Wiring Max Distance 800 Feet 1600 Feet 24 AWG 22 AWG Phone Line 5 6 PWR INPUT 1 Power Wiring Max Distance 100 Feet 200 Feet 18 AWG 16 AWG Earth Ground 4 Gate Operator 1 16 Volt, 20 VA UL Listed power transformer. Lock Pwr Strike / Mag Lck 2 Power for door strikes or magnetic lock is not provided by the system. It must be provided by an external power supply. 2 3 3 Electric strikes are wired to Normally Open (N.O.) contacts; magnetic locks are wired to the Normally Closed (N.C.) contacts. 4 Optional 12 Volt gel cell for backup power. 5 Dedicated Central Office (C.O.) phone line - touch tone, loop start. 6 7 A switch closure across terminals 4 & 8 will activate relay 1 for its programmed strike time. This is where the postal switch is prewired. A switch closure across these terminals will activate relay 2 for its programmed strike time or cause the system to dial a preprogrammed phone number. See 3.1.6. 8 Display must be removed to access these terminals (1802-EPD models only). All wiring to be performed in accordance with National Electric Code. Title: Date: DOORKING, INC., INGLEWOOD, CA 90301 Field Wire Diagram - 1862 Control Board 8/06 Dwg. No. M1800-065-11 Rev. B 1802-065-D-8-08 Page 19

2.3 Terminal Description MAIN TERMINAL DESCRIPTION 1 Phone Line Connection 800 ft. maximum with 24 AWG wire; 1600 ft. maximum with 22 AWG wire. 2 Phone Line Connection 800 ft. maximum with 24 AWG wire; 1600 ft. maximum with 22 AWG wire. 3 Earth Ground Only Not a Low Voltage Common! 4 Switch Input 1. A closure between terminals 4 and 8 will cause relay 1 to activate for the programmed strike time. The Postal Switch is connected here. 5 Microphone Input White Wire. 6 Microphone Input Green Wire. 7 Speaker Output. 8 Common for switch input 1, speaker and battery NEGATIVE (12 VDC). 9 Microphone Input Red Wire and battery POSITIVE (12 VDC). 10 Relay 1 Common. 11 Relay 1 Normally Closed (N.C.). 12 Relay 1 Normally Open (N.O.). 13 16 VAC Input Power 20 VA minimum. 100 ft. maximum with 18 AWG wire; 200 ft. maximum with 16 AWG wire. 14 16 VAC Input Power 20 VA minimum. 100 ft. maximum with 18 AWG wire; 200 ft. maximum with 16 AWG wire. RELAY 2 TERMINAL DESCRIPTION Left Center Right Relay 2 Normally Open (N.O.). Relay 2 Normally Closed (N.C.). Relay 2 Common. SWITCH 2 INPUT DESCRIPTION 1 & 2 Switch Input 2. A closure between these terminals will cause relay 2 to activate for the programmed strike time or dial a preprogrammed phone number (see 3.1.6). Do not run high voltage (115 V) power lines and communication lines in the same conduit. These should be in separate conduits at least six (6) inches apart. Be sure that all phone line wiring is twisted and completely isolated from ground. Use only the supplied 16.5 VAC (or U.L. listed equivalent) to power the entry system. Do not power any other devices (electric strikes, magnetic locks, lights, etc.) from this transformer. Do not run 16 VAC entry system power lines over 200 feet. It is advisable to keep these wires as short as possible. Use 18 AWG wire for wire runs up to 100 feet, and 16 AWG wire for wire runs up to 200 feet. Install a low voltage surge suppresser (DoorKing p/n 1878-010 or equivalent) to help protect the entry system from power surges. Page 20 1802-065-D-8-08

2.4 Adjustments 2.4.1 Speaker Volume 1. Open the front of the telephone entry system and locate the speaker volume adjustment. 2. Place a phone call from the telephone entry system to a resident. While they are talking, adjust the speaker volume potentiometer for adequate sound. To increase the volume rotate the potentiometer clockwise, to decrease the volume rotate the potentiometer counter clockwise. See Feedback adjustment (2.4.3 step 4). 2.4.2 Microphone Volume 1. Open the front of the telephone entry system and locate the microphone volume adjustment (Rev H boards and higher only). 2. Place a phone call from the telephone entry system to a resident. Talk to the resident in a normal voice while adjusting the microphone volume potentiometer. Ask the resident to let you know when the sound in their telephone is adequate. To increase the volume rotate the potentiometer clockwise, to decrease the volume rotate the potentiometer counter clockwise. See Feedback adjustment (2.4.3 step 4). 2.4.3 Feedback 1. Place a phone call from the telephone entry system to a resident. After they answer, ask the resident to remain silent. 2. Open the front of the telephone entry system. Remove the jumper from the TONE OFF terminals and place it on the TONE ON terminals. A tone will be heard in the speaker. 3. Rotate the feedback potentiometer clockwise, and then counter clockwise. When the tone from the speaker is minimum, this is the correct adjustment. 4. Move the jumper back to the TONE OFF terminals when complete. 5. High microphone and speaker volume levels may cause feedback. It may be necessary to reduce the speaker volume if the microphone volume is set too high. Likewise, it may be necessary to reduce the microphone volume if the speaker volume is set too high. 2.4.4 Click Sensitivity 1. Open the front of the telephone entry system and locate the click sensitivity adjustment. 2. Place a phone call from the telephone entry system to a resident with a rotary dial type phone. After they answer, ask the resident to dial 9 while you adjust the click sensitivity potentiometer (the resident may have to dial 9 several times for you to obtain the correct adjustment). When the door or gate opens, this is the correct adjustment for the click sensitivity. 3. NOTE: Adjusting the click sensitivity too high (potentiometer fully clockwise) could cause the system to respond to loud noises while it is in use. If this happens, rotate the click sensitivity potentiometer counter clockwise 1/8 turn and re-test the system. You may have to perform this step several times to find the correct adjustment. 2.4.5 Display Contrast 1. Open the front of the telephone entry system and locate the contrast adjustment. 2. Turn the master code switch on. The display will read MST CODE. While the display is lighted, turn the contrast potentiometer clockwise and then counter clockwise until the display is satisfactory. 3. Turn the master code switch off. 4. NOTE: Approximately 30 seconds after the master code switch is turned on, the system will signal a long tone. This is normal and can be ignored. After the master code switch is turned off, the display will read MST CODE for approximately 30 seconds. 1802-065-D-8-08 Page 21

2.4.6 Master Code Switch The master code switch is left in the off position for normal operation. Turn the master code switch on when setting the system master code. See programming instructions to set the system master code. If the master code switch is turned on and a new master code is not entered, the system will sound a long tone after approximately 30 seconds. This tone will continue every 30 seconds until a new master code is entered, or until the switch is turned off. After the switch is turned off, the display will remain lit for approximately 30 seconds, and then will go off. 2.4.7 Ring Pin The ring pin-shorting bar is labeled RING on the control board. This shorting pin must be installed to allow the system to answer any calls placed to it. If remote programming or remote relay operation is to be used, the shorting bar must be installed. Removing the shorting bar will cause the system to never answer any call placed to it. 2.4.8 Handset / Hands Free The handset shorting pins are labeled HS, and the hands free shorting pins are labeled HF on the control board. The shorting bar is factory set and will be placed in the HF position for hands free operation, or will be placed in the HS position for those entry systems ordered with the optional handset. Do not place shorting bars on both the HS and HF pins at the same time. Page 22 1802-065-D-8-08

SECTION 3 PROGRAMMING The DoorKing 1802 Telephone Entry Systems can be programmed from the keypad on the front of the entry system, or remotely from an off premise location using a touch tone telephone. When programming from an off site location with a touch-tone telephone, the RING pin must be installed on the circuit board (see 2.2.6). We recommend that you do not attempt programming from an off site location until you become familiar with these programming instructions. Programming from the Keypad Follow the programming instructions as described in each section of this manual. The system will prompt you with short (beep) tones when programming steps have been followed correctly and with a long tone (beeeeeep) when the programming step is ended. The LCD display will prompt you for information that you will need to enter. Programming from an Offsite Location Follow these steps when programming the system from an offsite location. You must use a touchtone telephone and the RING pin must be installed to perform off site programming. 1. Call the telephone number that the entry system is installed on from a touch-tone telephone. The entry system will answer with a one second tone. 2. Follow the programming instructions as described in each section of this manual. The system will prompt you with short (beep) tones when programming steps have been followed correctly. 3. When complete, hang up. (You cannot use 0 # to end remote programming sessions). Programming Notes When each programming step is performed correctly, a short tone (beep) will be heard. When the programming session is ended, a long tone (beeeeeep) will be heard. The blank symbol _ in the programming steps indicates numbers that you will need to enter, one number per blank. The amount of telephone numbers that can be programmed into the standard 1802 system is dependent on the memory size ordered. Memory sizes available are 125-500 - 1000. The 1802-EPD model has a standard memory size of 100. The memory size also determines the number of fourdigit entry codes (memory size + 12) that can be programmed into the system. Five-digit entry codes are limited to six. 1802-065-D-8-08 Page 23

3.1 General Programming 3.1.1 Master Code This programming step sets the system MASTER CODE. The master code is the four-digit number required to gain access to the system memory. You need to know the master code prior to performing any of the programming functions on the following pages. NOTE: The master code cannot be programmed from an off-site location. The master code can only be programmed from the system keypad. Factory setting = 9999 1. Open the cabinet of the telephone entry system and turn the master code switch (the small toggle switch) on. 2. Enter a four-digit master code then press * (beep). 3. Turn the master code switch off and close the cabinet. 3.1.2 Single or Multiple Systems This program sequence sets the telephone entry system to operate as a single unit on the phone line, or to share the phone line with other units. If multiple systems are sharing the same phone line, then each one must be set as a "multiple system" and each must have a unique master code. Factory setting = 0 (Single System). 1. Press *04 and then enter the four-digit MASTER CODE (beep). 2. Enter 0* (beep) for a single system or 1* (beep) for multiple systems. 3. Press 0# TOGETHER to end this programming step (beeeeeep). 3.1.3 Relay Strike Time These steps will program Relay 1 and Relay 2 strike times. Strike times can be programmed from 1/4 second (enter 00 in step 3) up to 99 seconds by entering the desired time in seconds. Factory setting for relay strike times are: Relay 1 = 01, Relay 2 = 01. 1. Press *03 and enter the four-digit MASTER CODE (beep). 2. Press 1* to set relay 1, or 2* to set relay 2 strike time. 3. Enter the two-digit strike time (00-99) then press * (beep). 4. Repeat steps 2 and 3 to set the other relay strike time. 5. Press 0# TOGETHER to end this programming step (beeeeeep). 3.1.4 Open Tone ON / OFF (Rev L boards and higher only) This step allows you to turn the open tone (when relay activates) either on or off. Factory setting = 1 (Tone ON). 1. Press *17 and enter the four-digit MASTER CODE (beep). Display indicates: 1=Y 0=N 2. Press 1* to turn the tone ON, or 0* to turn the tone OFF. 3. Press 0# TOGETHER to end this programming step (beeeeeep). Page 24 1802-065-D-8-08

3.1.5 Talk Time This programming sequence sets the maximum time allowed for conversation when the entry system places a call to the resident. The talk time can be set from 1 second up to 255 seconds (4 minutes, 15 seconds) and is entered as a three-digit number. For example, to set a talk time of 20 seconds, enter 020 in step 3. The talk time set here does not affect the telephone numbers that are programmed under directory codes 0, 00, 000, 0000 and 1, 01, 001, 0001. The talk time for these two directory codes are factory set to the maximum. Phone numbers programmed under these directory codes should be reserved for management or emergency phone numbers that generally require longer conversations. Factory setting for talk time = 060 (60-sec). 1. Press *08 and enter the four digit MASTER CODE (beep). 2. Enter three digits for talk time (seconds) _ (001-255) then press * (beep). 3. Press 0# TOGETHER to end this programming step (beeeeeep). 3.1.6 Tone Open Numbers These steps will program the tone open numbers for relays 1 and 2. You will need to enter a fourdigit number (see chart below) to set the relay functions. If a function is not desired, enter # in place of a number. For example, if you want the relay to have a momentary activation function only, and you want the relay to activate when the number 9 is pressed, enter 9 # # # in step 3. Do not duplicate tone open numbers, i.e., don t set relay 1, and 2 tone-open numbers to 9. Factory setting is: Relay 1 = 9876, Relay 2 = 5432. 1. Press *05 and enter the four-digit MASTER CODE (beep). 2. Press 1* to set relay 1 or 2* to set relay 2 tone numbers. 3. Enter the four-digit tone open number code then press * (beep). 4. Repeat steps 2 and 3 to set the other relay tone open numbers. 5. Press 0# TOGETHER to end this programming step (beeeeeep). CODE (step 3) FUNCTION 1 st Digit Momentary activation. Relay will activate for the programmed strike time (3.1.3). 2 nd Digit Relay hold. Relay will activate and remain activated until commanded to release. 3 rd Digit Relay release. Deactivates the relay hold command. 4 th Digit Relay hold 1-hour. Relay will activate for 1-hour and then will automatically deactivate itself. 3.1.7 Touch-tone / Rotary-dial This programming sequence will set the telephone entry system to dial out in either a touch-tone or rotary format. Generally, this will be set for touch-tone. Factory setting = 0 (touch-tone). 1. Press *07 and enter the four digit MASTER CODE (beep). 2. Enter 0* (beep) for touch-tone or enter 1* (beep) for rotary. 3. Press 0# TOGETHER to end this programming step (beeeeeep). 1802-065-D-8-08 Page 25

3.1.8 Programming Switch Inputs This programming sequence will set how the two switch inputs on the telephone entry system control board will operate. Switch input 1 is labeled PSW (postal switch) and is found on terminal 4 of the main terminal strip. Switch input 2 is a two terminal auxiliary input located on the upper left hand corner of the control board. These switch inputs can be programmed to activate their respective relays (switch 1 - relay 1, switch 2 - relay 2). They can also be programmed so that switch 1 dials out the phone number programmed in directory code 0, 00, 000, or 0000, and switch 2 dials out the phone number programmed in directory code 1, 01, 001, or 0001. Each switch is programmed independently. Factory setting is: Switch input 1 = 0 (relay 1 activates), Switch input 2 = 0 (relay 2 activates). 1. Press *23 and enter the four-digit MASTER CODE (beep). 2. Press 1* (beep) to set switch 1, or press 2* (beep) to set switch 2. 3. Press 0* (beep) to set the switch input to activate the relay, or press 1* (beep) to set the switch input to dial-out a preprogrammed phone number. 4. Press 0# TOGETHER to end this programming step (beeeeeep). 3.1.9 Number of Rings to Answer This programming sequence sets the number of rings to allow before the telephone entry system answers a call placed to it. This programming sequence does not affect the number of times that a resident s telephone will ring when a call is placed from the entry system to the resident. Factory setting = 02 (two rings). 1. Press *18 and enter the four-digit MASTER CODE (beep). 2. Enter the number of rings then press * (beep). 3. Press 0# TOGETHER to end this programming step (beeeeeep). 3.1.10 PBX Line Access Code Programming If the telephone entry system is connected to a PBX telephone system rather than a dedicated C.O. line, you may need to set the unit to dial a line access code prior to dialing the resident phone number. Typically, the line access code is 9, but check with the PBX system administrator to be sure. 1. Press *21 and enter the four-digit MASTER CODE (beep). 2. Enter the line access code number _ then press * (beep). 3. Press 0# TOGETHER to end this programming step (beeeeeep). NOTE: To change a line access number, enter the correct number in step 2. To delete a line access number, enter # in step 2. 3.1.11 Star (*) Key Function This programming sequence sets the function of the * key on the keypad during conversation. This key can be set to hang-up the entry system when pressed during conversation, or it can be programmed to touch-tone out during conversation. Factory setting = 0 (hang-up). 1. Press *27 and enter the four-digit MASTER CODE (beep). 2. Press 0* (beep) for hang-up, or press 1* (beep) for touch-tone. 3. Press 0# TOGETHER to end this programming step (beeeeeep). Page 26 1802-065-D-8-08

3.1.12 Keypad Function This programming sequence sets the function of the 0 through 9, and the # keys on the keypad during conversation. The keys can be set to hang-up the entry system when they are pressed during conversation, or they can be programmed to DTMF tone out during conversation. The later may be desirable if the entry system is used with an auto-attendant type telephone system where the caller is prompted to enter numbers from a touch-tone telephone. HINT: If DTMF tones are required, program the # or * key to hang-up the system. Factory setting = 0 for all numbers (hang-up). 1. Press *26 and enter the four-digit MASTER CODE (beep). 2. Enter the desired key number _ then press * (beep). 3. Press 0* (beep) for hang-up, or press 1* (beep) for touch-tone. 4. Repeat steps 2 and 3 to program other keys. 5. Press 0# TOGETHER to end this programming step (beeeeeep). 3.1.13 System to Stay On-Line or Hang Up after Touch Tone This programming sequence provides a method for the telephone entry system to remain on line after a resident has pressed the touch tone number to open the door or gate. Each relay can be set independently to either remain on line or hang up. Factory setting = 1 (hang up after touch tone) for both relays. 1. Press *28 and enter the four-digit MASTER CODE (beep). 2. Press 1* for relay 1 (beep), or press 2* for relay 2 (beep). 3. Press 0* (beep) to keep the system on line, or press 1* (beep) to make it hang up. 4. Repeat steps 2 and 3 to program the other relay. 5. Press 0# TOGETHER to end this programming step (beeeeeep). 3.1.14 Automatic Hang-up Function This programming sequence determines when the phone system will automatically hang itself up after a predetermined time of inactivity. You can program the system to not hang-up (0), to hang-up after 5 sec of dial-tone (1), to hang-up after 15 sec of silence (2) or to hang-up after either 5 sec of dial-tone or 15 sec of silence (3). NOTE: This programming function is available on REV G boards or higher only. Factory setting = 1 (hang-up after 5 sec of dial-tone). 1. Press *40 and enter the four-digit MASTER CODE (beep). 2. Enter the hang-up code desired _ then press * (beep). 3. Press 0# TOGETHER to end this programming step (beeeeeep). Code Function 0 No hang-up. 1 Hang-up after 5 sec. of dial-tone (Factory setting). 2 Hang-up after 15 sec. of silence. 3 Hang-up after 5 sec. of dial-tone OR 15 sec. of silence. 1802-065-D-8-08 Page 27

3.2 Phone Number programming 3.2.1 Programming the Directory Code Length This programming sequence sets the directory code length to 1-2 - 3 or 4 digits. If 11 or more resident names or telephone numbers are going to be programmed into the system, the directory code must be at least two-digits. If 101 or more resident names or telephone numbers are going to be programmed, the directory code must be at least three-digits. Factory setting is three (3) digits. CAUTION: This programming sequence will delete all phone numbers and directory codes that have been previously programmed into the system. 1. Press *20 and enter the four-digit MASTER CODE (beep). 2. Enter the directory code digit length (1-2-3 or 4) then press * (beep). 3. Press 0* (beep) to cancel this function or press 1* (beeeeeep) to confirm the change. The programming sequence will automatically end itself after pressing 1*. 3.2.2 Programming 7-digit Phone Numbers In this programming sequence, the directory codes and 7-digit phone numbers will be programmed into the system. Be sure you have programmed the directory code length that you desire as described in 3.2.1. Changing the directory code length after programming the telephone numbers will erase all the numbers and directory codes that have been programmed. To program phone numbers that will be referenced to an area code (long distance calls and 10 digit calling), follow the instructions under Long Distance Phone Number Programming on the next page. If you use directory codes 0, 00, 000, 0000 and/or 1, 01, 001, 0001 remember that the talk time for these directory codes are factory set to the maximum and cannot be changed. Use these directory codes to program management or emergency phone numbers, which generally require longer conversation periods. NOTE: If this telephone entry system is being used in an area that requires 10-digit dialing, proceed to 3.2.3 and 3.2.4 to program the area code and phone number. 1. Press *01 and enter the four-digit MASTER CODE (beep). 2. Enter the directory code (1, 2, 3 or 4 digits depending on what was programmed in 3.2.1) then press * (beep). 3. Enter the seven-digit phone number _ then press * (beep). If the number that you are entering in this step is less than seven-digits, enter # in the empty spaces. For example, if the system is connected to a PBX that requires four-digit extension numbers and you want to enter extension 2217, you would enter this number as 2217### then press * (beep). 4. Repeat steps 2 and 3 to enter additional directory codes and phone numbers. 5. Press 0# TOGETHER to end this programming step (beeeeeep). Page 28 1802-065-D-8-08

3.2.3 Programming Area Codes Up to 15 different area codes can be programmed for any 10-digit or long distance calling requirements and will be referenced 01 through 15. The area codes will be entered as a four-digit number (1 + the three digit area code). If area codes are being programmed to facilitate 10-digit calling requirements, precede the three-digit area code with #. 1. Press *24 and enter the four-digit MASTER CODE (beep). 2. Enter a 2-digit area code reference number (01 through 15) then press * (beep). 3. Enter the area code then press * (beep). NOTE-1: for long distance calling requirements, enter 1 and the three-digit area code. NOTE-2: for 10-digit calling requirements, enter # and the three-digit area code. 4. Repeat steps 2 and 3 to enter additional area codes. Remember to use a different area code reference number when entering more area codes. 5. Press 0# TOGETHER to end this programming step (beeeeeep). 3.2.4 Programming Phone Numbers with Area Code Reference In this section, phone numbers that are referenced to an area code (long distance and 10-digit dialing calls) will be programmed. Be sure that the area code(s) have been programmed as described in the preceding section. NOTE: If long distance or 10-digit dialing is not required, program the seven digit telephone numbers as described in 3.2.2. 1. Press *41 and enter the four-digit MASTER CODE (beep). 2. Enter a directory code (1, 2, 3 or 4 digits depending on what was programmed in 3.2.1) then press * (beep). 3. Enter the 2 digit area code reference number then press * (beep). 4. Enter the seven-digit phone number _ then press * (beep). If the number that you are entering in this step is less than seven-digits, enter # in the empty spaces. For example, if the system is connected to a PBX that requires four-digit extension numbers and you want to enter extension 2217, you would enter this number as 2217### then press * (beep). 5. Repeat steps 2, 3, and 4 to enter additional long distance phone numbers. 6. Press 0# TOGETHER to end this programming step (beeeeeep). 3.2.5 Deleting Individual Phone Numbers This programming sequence is used to delete a single phone number under a known directory code. 1. Press *01 and enter the four-digit MASTER CODE (beep). 2. Enter the directory code of the phone number to be deleted (1, 2, 3 or 4 digits depending on what was programmed in 3.2.1) then press * (beep). 3. Press # # # # # # # then press * (beep). 4. Repeat steps 2 and 3 to delete additional phone numbers. 5. Press 0# TOGETHER to end this programming step (beeeeeep). 1802-065-D-8-08 Page 29