Selector guide. PSC Square body fuses Size 7X VAC End contact terminals. Features and Benefits

Similar documents
Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnecraft Power Relays

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

A V 50Hz / V 60Hz

Type: DILM25 10(24V50HZ) Article No.:

Kuhnke Technical Data. Contact Details

Type: DILM12 10(24VDC) Article No.:

02/11/2015

ALLEN BRADLEY TIMING RELAY

Pluggable interface relays CR-M Miniature relays

Minicontactorrelay,2NO/2NC,DCoperated

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Series CDP2 Definite Purpose Contactors

AS09..S 3-pole Contactors - Spring Terminals

Pluggable interface relays CR-M Miniature relays

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

Bimetal Temperature Switch

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

AC diagonal module Ø 200 mm

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

.Power Distribution Center. PD-1. Instruction Manual

Series CDP2 Definite Purpose Contactors

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

Series CT7N Bimetallic Overload Relays

Datasheet - SRB-E-201ST

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Digital output modules

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA)

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

Datasheet - SRB301LC 24VAC/DC

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

Data Sheet Definite Purpose Contactors Ex9CK Series

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

Safety dialogue solutions

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

GV2ME. Main. Device short name. Device application

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Ordering details. Approval. Classification

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Read/write head TN-CK40-H1147

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA


Lighted Pushbutton Switch (Square) Ultra Bright LED Type

02/11/2015

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Modular pulse operated latching relay 16 A

EMC Solutions Noise filtering

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Magnetic Stirrers Magnetic Stirr

multi-function meters

High performance circuit breakers

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

llen-bradley 194R-HM4-NFPA3

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

INNOVATION IN MAGNETICS DS3434/5. Mag612. Miniature Three-Axis Fluxgate Probe.

Bulletin 190 IEC Modular Starter System

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

Type Contact form Model

Interface Relays and Optocouplers Product group picture

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

Absolute Encoders Multiturn

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

10 PDUs 19 PDUs Zero-U PDUs

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

16 A and 25 A power contactors with or without handle

Flexible Counter Series in DIN size 24 x 48 mm

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

MaxiBridge mm Connectors. Ed Full-scale MaxiBridge 8 Pins Catalog E

BUL1203EFP HIGH VOLTAGE FAST-SWITCHING NPN POWER TRANSISTOR

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Power Circuit of a UL508A Panel. Typical UL489 Application

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

APPLICATIONS. Automatic warehouse. Trasportation lines

MIKRO POWER FACTOR CORRECTION COMPONENTS

Transcription:

Selector guide PSC Square body fuses Size 7X 600 100C End contact terminals November 201 Issue 2 The IXYS UK range of 100/1250 protistor fuse links provides maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These square body fuse links are available in different body sizes, each size having multiple worldwide acceptable mounting styles. These protistors have been designed to provide state of the art protection for all IXYS UK high power semiconductors; diodes, thyristors, GTO s and IGBT devices. These fuses are assembled with pure silver, die cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I 2 t and high interrupting rate level. ll contact surfaces are silver plated and all hardware is nonmagnetic Each fuse link is equipped with a low voltage trip indicator which can operate a field mountable microswitch. Features and Benefits Ultra fast acting Current limiting ery low I 2 t for improved semiconductor protection Superior cycling capability Multiple body sizes and terminal connections ar class according to DE 66 2 and IEC 60269 4 pplications Protection of inverters, UPS systems, motor drives and similar equipment rated at 100/1250 or less pprovals UL/CS recognised component C: UL guide no. E76491 IEC 60269 4 compliance RoHS compliant

Selector guide PSC Square body fuses Size 7X 600 100C end contact Terminals Nomenclature The IXYS UK range of 100/1250 protistor fuse links with blade terminals consists of five different body styles and the following nomenclature details the breakdown of each type 1 2 4 5 6 125 UR 2 S 0400 B Rated voltage Type and Fixing R current Size 10 standard dimension rating Indicator type Type and Standard Information US DIN 4 65 US dimensions, large square body UR DIN 4 65, German/French dimensions, large square body Body Size 0 70 1 71 2 72 7 Fixing Dimension S Stud/threaded hole, metric thread U Stud/threaded hole, imperial thread Indicator Type B Button type Example 125UR2S0400B is 100/1250C (R), DIN 4 65 German/French dimensions, large square body, size 72, metric thread, 400 nominal R current with button indicator

Selector guide PSC Square body fuses Size 7X 600 100C end contact Terminals Size 70 fuses Part numbers Weight 50g Max. US0U fuses US dimensions UR0S fuses UR dimensions Part Number 100/1250 6 ar 10US0U006B 100/1250 80 ar 10US0U0080B 100/1250 100 ar 10US0U0100B 100/1250 125 ar 10US0U0125B 100/1250 160 ar 10US0U0160B 100/1250 200 ar 10US0U0200B 100/1250 250 ar 10US0U0250B 100/1250 280 ar 10US0U0280B 100/1250 15 ar 10US0U015B 1200/1100 50 ar 120US0U050B Size 70 fuses Ratings Rated oltage (UL/IEC) Part Number 100/1250 50 ar 125UR0S0050B 100/1250 6 ar 125UR0S006B 100/1250 80 ar 125UR0S0080B 100/1250 100 ar 125UR0S0100B 100/1250 125 ar 125UR0S0125B 100/1250 160 ar 125UR0S0160B 100/1250 200 ar 125UR0S0200B 100/1250 250 ar 125UR0S0250B 100/1250 280 ar 120UR0S0280B 100/1250 15 ar 120UR0S015B 1200/1100 50 ar 110UR0S050B* 1200/1100 400 ar 110UR0S0400B* 1200/1100 450 ar 110UR0S0450B* 1100/1000 500 ar 100UR0S0500B* 900/800 550 ar 080UR0S0550B* Nominal Current Pre arcing I 2 t Clearing I 2 t @ Watts loss @ 100% In Breaking capacity @ k 2 s k 2 s W k 100/1250 50 ar 0.116 0.7 16 100 100/1250 6 ar 0.21 1.2 26 100 100/1250 80 ar 0.47 2.7 27 100 100/1250 100 ar 0.8 4.8 0 100 100/1250 125 ar 1. 7.5 8 100 100/1250 160 ar 2.55 15 45 100 100/1250 200 ar 4.7 27 56 100 100/1250 250 ar 9.6 55 61 100 100/1250 280 ar 14 82 64 100 100/1250 15 ar 20 115 72 100 1200/1100 50 ar 28 158 75 150 1200/1100 400 ar 9 224 90 150 1200/1100 450 ar 62 56 82 150 1100/1000 500 ar 84 48 8 120 900/800 550 ar 128 576 8 100 * Non UL recognised rating

Selector guide PSC Square body fuses Size 7X 600 100C end contact Terminals Size 71 fuses Part numbers Weight 500g Max. for US dimensions, 520g Max. for UR dimensions US1U fuses US dimensions UR1S fuses UR dimensions Size 71 fuses Ratings Rated oltage (UL/IEC) Part Number 100/1250 160 ar 10US1U0160B 100/1250 200 ar 10US1U0200B 100/1250 250 ar 10US1U0250B 100/1250 280 ar 10US1U0280B 100/1250 15 ar 10US1U015B 100/1250 50 ar 10US1U050B 100/1250 400 ar 10US1U0400B 100/1250 450 ar 10US1U0450B 1200/1100 500 ar 120US1U0500B 1200/1100 550 ar 120US1U0550B 1100/1000 60 ar 120US1U060B* Part Number 100/1250 160 ar 125UR1S0160B 100/1250 200 ar 125UR1S0200B 100/1250 250 ar 125UR1S0250B 100/1250 280 ar 125UR1S0280B 100/1250 15 ar 125UR1S015B 100/1250 50 ar 125UR1S050B Product 100/1250 Brief Title 400 ar 125UR1S0400B 100/1250 450 ar 125UR1S0450B 1200/1100 500 ar 110UR1S0500B 1200/1100 550 ar 110UR1S0550B 1100/1000 60 ar 100UR1S060B 1100/1000 700 ar 100UR1S0700B 950/900 800 ar 090UR1S0800B 850/800 900 ar 080UR1S0900B Nominal Current Pre arcing I 2 t Clearing I 2 t @ Watts loss @ 100% In Breaking capacity @ k 2 s k 2 s W k 100/1250 160 ar 2.6 15 46 100 100/1250 200 ar 4.7 27 54 100 100/1250 250 ar 8.9 51 61 100 100/1250 280 ar 12 68 70 100 100/1250 15 ar 16 92 76 100 100/1250 50 ar 22 127 80 100 100/1250 400 ar 8 220 80 100 100/1250 450 ar 47 270 95 100 1200/1100 500 ar 68 90 100 150 1200/1100 550 ar 84 485 112 150 1100/1000 60 ar 125 725 120 150 1100/1000 700 ar 180 1040 105 150 Selector guide PSC Square body fuses Size 7X 900 100C Blade Terminals 950/900 800 ar 290 1540 116 100 850/800 900 ar 446 2010 120 100 * Non UL recognised rating

Selector guide PSC Square body fuses Size 7X 600 100C end contact Terminals Size 72 fuses Part numbers Weight 850g Max. for US dimensions, 800g Max. for UR dimensions US2U fuses US dimensions UR2S fuses UR dimensions Part Number 100/1250 280 ar 10US2U0280B 100/1250 15 ar 10US2U015B 100/1250 50 ar 10US2U050B 100/1250 400 ar 10US2U0400B 100/1250 450 ar 10US2U0450B 100/1250 500 ar 10US2U0500B 100/1250 550 ar 10US2U0550B 1200/1100 60 ar 120US2U060B* 1100/1000 700 ar 110US2U0700B* 1100/1000 800 ar 110US2U0800B* Part Number 100/1250 250 ar 125UR2S0250B 100/1250 280 ar 125UR2S0280B 100/1250 15 ar 125UR2S015B 100/1250 50 ar 125UR2S050B 100/1250 400 ar 125UR2S0400B 100/1250 450 ar 125UR2S0450B 100/1250 500 ar 125UR2S0500B 100/1250 550 ar 125UR2S0550B 1200/1100 60 ar 110UR2S060B* 1200/1100 700 ar 100UR2S0700B* 1200/1100 800 ar 100UR2S0800B* 1100/1000 900 ar 100UR2S0900B* 900/850 1000 ar 085UR2S1000B* Size 72 fuses Ratings Rated oltage (IEC/UL) Nominal Current Pre arcing I 2 t Clearing I 2 t @ Watts loss @ 100% In Breaking capacity @ k 2 s k 2 s W k 100/1250 250 ar 100/1250 280 ar 10 60 72 100 100/1250 15 ar 15 87 76 100 100/1250 50 ar 21 120 77 100 100/1250 400 ar 2.5 190 80 100 100/1250 450 ar 44 255 89 100 100/1250 500 ar 57 0 98 100 100/1250 550 ar 68 90 120 100 1200/1100 60 ar 105 610 125 150 1200/1100 700 ar 145 815 140 150 1200/1100 800 ar 215 1240 146 150 1100/1000 900 ar 12 1800 152 150 Product Brief 900/850 Title 1000 ar 49 2150 16 100 * Non UL recognised rating

Selector guide PSC Square body fuses Size 7X 600 100C end contact Terminals Size 7 fuses Part numbers Weight 1250g Max. USU fuses US dimensions Part Number 100/1250 15 ar 10USU015B 100/1250 50 ar 10USU050B 100/1250 400 ar 10USU0400B 100/1250 450 ar 10USU0450B 100/1250 500 ar 10USU0500B 100/1250 550 ar 10USU0550B 100/1250 60 ar 10USU060B 100/1250 700 ar 10USU0700B 100/1250 800 ar 10USU0800B 100/1200 900 ar 10USU0900B 1100/1000 1000 ar 110USU1000B 1000/950 1100 ar 100USU1100B 1000/900 1250 ar 100USU1250B 900/850 1400 ar 090USU1400B 700/690 1600 ar 070USU1600B 650/600 1800 ar 065USU1800B URS fuses UR dimensions Size 7 fuses Ratings Part Number 100/1250 15 ar 125URS015B 100/1250 50 ar 125URS050B 100/1250 400 ar 125URS0400B 100/1250 450 ar 125URS0450B 100/1250 500 ar 125URS0500B 100/1250 550 ar 125URS0550B 100/1250 60 ar 125URS060B 100/1250 700 ar 120URS0700B 100/1250 800 ar 125URS0800B 100/1200 900 ar 120URS0900B 1100/1000 1000 ar 100URS1000B 1000/950 1100 ar 095URS1100B 1000/900 1250 ar 090URS1250B 900/850 1400 ar 085URS1400B 700/690 1600 ar 069URS1600B 650/600 1800 ar 060URS1800B Pre arcing I 2 Clearing I 2 t @ Watts loss @ Breaking capacity @ t 100% In k 2 s k 2 s W k 100/1250 15 ar 12 68 84 100 100/1250 50 ar 17 100 86 100 100/1250 400 ar 25 145 9 100 100/1250 450 ar 5.5 205 100 100 100/1250 500 ar 44 255 112 100 100/1250 550 ar 57 0 120 100 100/1250 60 ar 84 485 12 100 100/1250 700 ar 110 640 100 100/1250 800 ar 190 1090 100 100/1200 900 ar 250 1440 100 1100/1000 1000 ar 70 1920 168 150 1000/900 1100 ar 445 2280 150 1000/900 1250 ar 585 080 150 900/850 1400 ar 755 700 150 700/690 1600 ar 140 5740 180 650/600 1800 ar 2040 7150 120

Selector guide PSC Square body fuses Size 7XX 600 100C end contact Terminals Drawings and Dimensions USxU fuses Size US0U 40 US1U 51 US2U 60 USU 74.5 B C 46.5 82 56.5 91 65.5 100 79.5 114 D d E 26 5/16 18 74 0 5/16 18 74 8 /8 16 74 46 1/2 1 74 G P 9 6 9 9 15 9 15 9 URxS fuses Size UR0S UR1S UR2S URS 40 51 60 74.5 B 46.54 56.55 65.56 79.57 C 82 91 100 114 D 26 0 8 46 d M8 M8 M10 M12 E G M N P 74 9 222 27 6 74 9 199 24 9 74 15 199 9 9 74 15 244 9 9 ll dimensions in mm unless otherwise stated www.ixy ysuk.com

Selector guide PSC Square body fuses Size 7X 600 100C end contact Terminalss Microswitches IXYS UK can offer a range of microswitches to suit our PSC square bodied fuse ranges System: Fuse sizes: Indication style: 7 1 70, 71, 72, 7 7 1 5 = Standard NO NC 7 1 5 BS = Low Level NO NC 7 1 5 ET = Low Level NO NC IP 50 (9) 7 1 9 BS = Low Level NO NC Partt number 7 1 5 7 1 5 BS 7 1 5 ET C Insulation oltage Rating *** () 1500 Positive Operating oltage/current (/m) 20/50 10/10 10/10 Current Rating () Current () 10 C 50/ /60Hz DCC 10 8 C 50/ /60Hz DCC 0 C 50/ /60Hz DCC Interrupting Rating () Non inductive circuit 110 250 10 0.4 0.5 0.25 0.5 Inductive Circuit: L/R = 25ms 0 10 10 0.2 4 2 2 2 110 250 10 0.2 1 0.2 1 0.2 C oltage Withstandd * (k) 10 8.5 0.1 12 1 8.5 0.1 12 1 8.5 12 Impulse oltage test imp 1.2/50µs ** (k) 14 20 14 20 14 20 Fire according to UL 94 H.B. 7 1 9 BS 10/10 C 50/ /60Hz DCC 2 0.5 0.25 2 1 0.2 1 8.5 0.1 12 14 20 Fuse Holder Part Number Fuse size Fuse Type Insulation oltage () C, 50/60Hz & DC Rated Current () Dimensions B C D E G L M F SI TT 70/71 SI TT 72/7 70 71 72 7 Stud 1500 1000 2500 118 12 17 145 170 8 42 88 51 9 60 109 75 4 6 50.6 202 M8 M10 M12 57 ll dimensions in mm IXYS UK Westcode Ltd s BS EN ISO9001 quality system is registered by BSI Langley Park Way Chippenham, SN15 1GE United Kingdom Tel: +44 (0)1249 444524 Fax: +44 (0)1249 659448 E mail: sales@ixysuk.net Edisonstr. 155 D 6862 Lampertheim Germany Tel: +49 (0) 6206 50 0 Fax: +44 (0) 6206 50627 E mail: marcom@ixys.de www.ixy ysuk.com We are supported by a global network of local offices, representatives and distributors. Please visit ourr website for more information