Trusted 40 Channel 120 Vac Digital Input FTA

Similar documents
Trusted 40 Channel 120 Vac Digital Input FTA

Trusted 40 Channel Analogue Input FTA

Trusted TMR I/O SmartSlot Slot Cables

Backlight Replacement

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Model 1421 Distribution Amplifier

Power Injector 1520 Series

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

llen-bradley 194R-HM4-NFPA3

User Guide. HDMI Fiber Optic Extender. DVI-7350a

Industrial Monitor Update Kit

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

Instructions. P MHz 1X/10X Passive Probe

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Spectra Batten (Order code: LEDJ95)

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Colour Explosion Proof Video Camera USER MANUAL VID-C

MICROMASTER Encoder Module

GuardPLC Certified Function Blocks -- Basic Suite

Model Camera System (CCTV) User Manual

DA1931CT/ TP to Video + Audio Receiver

CNK221/241/261/321/341/361 Cable-Nook Jr. User s Guide

Document Part Number: Copyright 2010, Corelis Inc.

Model Number Structure

Installation Guide VL-MV10. Model No.


3G/HD/SD-SDI to HDMI Converter

9" B/W MONITOR CEM-09/09A-2 12" B/W MONITOR CEM-12/12A-2 OPERATION MANUAL

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

P XGA TFT Monitor. User s Manual

PAM-1840 Preamplifier Operation Manual

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

DISTRIBUTION AMPLIFIER

Kramer Electronics, Ltd. USER MANUAL VM-20HD. Dual 1:10 HD/SD SDI Distribution Amplifier

Electro Magnetic Compatibility (EMC) Warning. Important notes for users in the U.K. FCC declaration. Caution. Fuse

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

User Guide. DVI + HDCP Fiber Optic Extender DVI-7330

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

SC / /205 Passive Audio Adapters User s Guide

Stratos Duo RGB. User Manual. Order code: EQLED371

Children cannot always recognize potential hazards properly. This 5.1 system is not designed for operation in a heavy industry environment.

AEQ TH-03 Digital Hybrid of 1 (TH-03.1) or 2 lines (TH-03.2) with Frequency Extender

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

5 Port DVI Splitter VIDEO WALLS VIDEO PROCESSORS VIDEO MATRIX SWITCHES EXTENDERS SPLITTERS WIRELESS CABLES & ACCESSORIES

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

DA1909 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE

32 Channel CPCI Board User Manual

KHT 1000C HV-Probe Calibrator. Instruction Manual

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

SQM40/41 Actuators for air and gas dampers

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

Operation Manual VMS 3.0 Video System

Installation and Operation Manual

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

User Guide. HDMI Active Cable Extender. DVI-7370c

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1.

Spectroscopy Module. Vescent Photonics, Inc E. 41 st Ave Denver, CO Phone: (303) Fax: (303)

Monochrome Video Monitors

HD1-DX HDMI Extender

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

Cisco Aironet 1520 Series Outdoor Mesh Access Point Power Injector Installation Instructions

CVSB/ S-video/ HDMI to HDMI Scaler with 720p and 1080p Switching.

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Introduction Front Panel Functions Rear Panel Functions Precautions Placement & Ventilation... 5

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2

Installation Guide. Cellular Plug-in for Inverters with SetApp. Version 1.1

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

USER S MANUAL CCTV LED MONITOR MODEL: ADE-117N1 ADE-119N1 ADE-118W1 ADE-121W1 ADE-124W Atherton Electronics Corp. All rights reserved.

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

TVAC20000 User manual

SG4424 HDTV Slave Sync Generator User Guide

CM-S38901SV TVL IR Long Range camera

Serial Flash Programmer. S550-SFWv3 FA Mode. Operation Manual. Sunny Giken Inc.

TP HDMI OVER ANYWIRE TRANSMITTER

MS2540 Current Loop Receiver with RS485 Communication

LINE DRIVERS MANUAL PART NUMBER: DA3000TM0 1-IN, 1-OUT COMPOSITE VIDEO + AUDIO LINE DRIVER TABLE MOUNT USER S GUIDE

TIL311 HEXADECIMAL DISPLAY WITH LOGIC

LINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1

SWR Programmable Audio Switcher U S E R S M A N U A L

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD-TC SPECIAL FUNCTION BLOCK USER S GUIDE

VGA to DVI Extender over Fiber SET

Dell Wyse 5030 PCoIP Zero Client

DALI TOUCHPANEL BASIC TW. Operating and control unit

DisplayPort Extender over 2 LC Fibers

MANUAL ENGLISH Core Club Ordercode: D2314

User Manual. AtlonA. 1 x 10 VGA with Stereo Audio Distribution Amplifier over CAT5/6 compatible with AT-VGA300RL AT-VGA10SS

Kramer Electronics, Ltd.

TP HDMI OVER ANYWIRE RECEIVER (DC)

DS / /113. Pair (TP) User s Guide

SDP-RFD AC-3 /RF DEMODULATOR (120V/230V) INSTALLATION/ TECHNICAL MANUAL

Transcription:

PD-T8824 Trusted Trusted 40 Channel 120 Vac Digital Input FTA Product Overview The Trusted 40 Channel 120 Vac Digital Input Field Termination Assembly (FTA) T8824 is designed to act as the main interface between a field device generating a digital signal and the Trusted TMR 120 Vac Digital Input Module T8424. Features: 40 input channels per FTA. Industry standard field device connections (2-wire). Standard DIN rail compatibility. Simple installation and connection. 120 Vac operation. Fused field power supply per channel. Rockwell Automation Publication PD-T8824 Issue 5

Trusted PD-T8824 Page intentionally left blank Rockwell Automation Publication PD-T8824 Issue 5

Trusted 40 Channel 120 Vac Digital Input FTA PREFACE PREFACE In no event will Rockwell Automation be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples given in this manual are included solely for illustrative purposes. Because of the many variables and requirements related to any particular installation, Rockwell Automation does not assume responsibility or reliability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, with respect to use of information, circuits, equipment, or software described in this manual. All trademarks are acknowledged. DISCLAIMER It is not intended that the information in this publication covers every possible detail about the construction, operation, or maintenance of a control system installation. You should also refer to your own local (or supplied) system safety manual, installation and operator/maintenance manuals. REVISION AND UPDATING POLICY This document is based on information available at the time of its publication. The document contents are subject to change from time to time. The latest versions of the manuals are available at the Rockwell Automation Literature Library under "Product Information" information "Critical Process Control & Safety Systems". TRUSTED RELEASE This technical manual applies to Trusted Release: 3.6.1. LATEST PRODUCT INFORMATION For the latest information about this product review the Product Notifications and Technical Notes issued by technical support. Product Notifications and product support are available at the Rockwell Automation Support Centre at http://rockwellautomation.custhelp.com At the Search Knowledgebase tab select the option "By Product" then scroll down and select the Trusted product. Some of the Answer ID s in the Knowledge Base require a TechConnect Support Contract. For more information about TechConnect Support Contract Access Level and Features please click on the following link: https://rockwellautomation.custhelp.com/app/answers/detail/a_id/50871 This will get you to the login page where you must enter your login details. Rockwell Automation Publication PD-T8824 Issue 5 i

PREFACE Trusted 40 Channel 120 Vac Digital Input FTA IMPORTANT A login is required to access the link. If you do not have an account then you can create one using the "Sign Up" link at the top right of the web page. DOCUMENTATION FEEDBACK Your comments help us to write better user documentation. If you discover an error, or have a suggestion on how to make this publication better, send your comment to our technical support group at http://rockwellautomation.custhelp.com ii Issue 5 Rockwell Automation Publication PD-T8824

Trusted 40 Channel 120 Vac Digital Input FTA PREFACE SCOPE This manual specifies the maintenance requirements and describes the procedures to assist troubleshooting and maintenance of a Trusted system. WHO SHOULD USE THIS MANUAL This manual is for plant maintenance personnel who are experienced in the operation and maintenance of electronic equipment and are trained to work with safety systems. SYMBOLS In this manual we will use these notices to tell you about safety considerations. SHOCK HAZARD: Identifies an electrical shock hazard. If a warning label is fitted, it can be on or inside the equipment. WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which can cause injury or death, property damage or economic loss. ATTENTION: Identifies information about practices or circumstances that can cause injury or death. CAUTION: Identifies information about practices or circumstances that can cause property damage or economic loss. BURN HAZARD: Identifies where a surface can reach dangerous temperatures. If a warning label is fitted, it can be on or inside the equipment. This symbol identifies items which must be thought about and put in place when designing and assembling a Trusted controller for use in a Safety Instrumented Function (SIF). It appears extensively in the Trusted Safety Manual. IMPORTANT NOTE TIP Identifies information that is critical for successful application and understanding of the product. Provides key information about the product or service. Tips give helpful information about using or setting up the equipment. Rockwell Automation Publication PD-T8824 Issue 5 iii

PREFACE Trusted 40 Channel 120 Vac Digital Input FTA WARNINGS AND CAUTIONS WARNING: EXPLOSION RISK Do not connect or disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations or equivalent AVERTISSEMENT - RISQUE D EXPLOSION Ne pas connecter ou déconnecter l équipement alors qu il est sous tension, sauf si l environnement est exempt de concentrations inflammables ou équivalente MAINTENANCE Maintenance must be carried out only by qualified personnel. Failure to follow these instructions may result in personal injury. CAUTION: RADIO FREQUENCY INTERFERENCE Most electronic equipment is influenced by Radio Frequency Interference. Caution should be exercised with regard to the use of portable communications equipment around such equipment. Signs should be posted in the vicinity of the equipment cautioning against the use of portable communications equipment. CAUTION: The module PCBs contains static sensitive components. Static handling precautions must be observed. DO NOT touch exposed connector pins or attempt to dismantle a module. iv Issue 5 Rockwell Automation Publication PD-T8824

Trusted 40 Channel 120 Vac Digital Input FTA PREFACE ISSUE RECORD Issue Date Comments No issue record in source 5 Jun 16 Rebranded and updated to incorporate IEEE standards with correction of typographical errors and also standardise the Relative Humidity Range and Operating Temperature statements in the Specification Section. Rockwell Automation Publication PD-T8824 Issue 5 v

PREFACE Trusted 40 Channel 120 Vac Digital Input FTA Page intentionally left blank vi Issue 5 Rockwell Automation Publication PD-T8824

Trusted 40 Channel 120 Vac Digital Input FTA Table of Contents Table of Contents 1. Description... 3 2. Installation... 5 3. Associated Cable Selection... 7 4. Cable Capacitance... 9 5. Assembly Pinout Connections... 11 5.1. AC TB1 Connections... 11 5.2. Field TB1 Connections... 11 5.3. Field TB2 Connections... 12 5.4. Field TB3 Connections... 13 5.5. Field TB4 Connections... 13 5.6. Field TB5 Connections... 13 5.7. TBG1 Connections... 14 5.8. TBG2 Connections... 14 5.9. TBG3 Connections... 15 5.10. TBG4 Connections... 16 5.11. TBG5 Connections... 16 6. Specifications... 19 Rockwell Automation Publication PD-T8824 Issue 5 1

Table of Contents Trusted 40 Channel 120 Vac Digital Input FTA Page intentionally left blank 2 Issue 5 Rockwell Automation Publication PD-T8824

Trusted 40 Channel 120 Vac Digital Input FTA 1. Description 1. Description Figure 1 T8824 Layout and Photo The Trusted 40 Channel 120 Vac Digital Input FTA T8824 provides termination for a maximum of 40 input channels from various types of field devices which generate a digital input. Figure 2 below shows the configuration of a single channel. Rockwell Automation Publication PD-T8824 Issue 5 3

1. Description Trusted 40 Channel 120 Vac Digital Input FTA FIELD SWITCH 50mA Fuse 22K FIELD AC INPUT (0-150Vrms) 330R AC Out to T8424 Module (0-2.2Vrms) Figure 2 Single Channel Schematic The supply for the field is derived from a 120 Vac feed which is connected to AC Input terminal block TB1. The supply is then fed to each channel. The supply voltage to the field is fed via the 50 ma fuse. This effectively limits the current in the field loop. The incoming signal (digital) from the field device is fed to the digital input module via a resistive divider. This divides the voltage down to levels suitable for an analogue measurement. Revision E T8824 FTAs use two power resistors in series, as shown in the circuit diagram in Figure 2. Earlier revisions used 4x4 resistor arrays. The resistor arrays on the top half are 68 K and the bottom resistor arrays are 1 K. Line monitoring is limited to voltage detection on the module. Refer to PD-T8424 for details. The cable linking the 40 channels on the input module to the FTA is terminated at five 10-way connectors (TBG1 to TBG5). The input signals from the field (40-off) are connected by 2-wire arrangements terminated on 5-off 16-way terminal blocks. 4 Issue 5 Rockwell Automation Publication PD-T8824

Trusted 40 Channel 120 Vac Digital Input FTA 2. Installation 2. Installation Trusted 40 Channel 120 Vac Digital Input FTA T8824 is designed to be mounted on either of the TS32 or TS35 DIN rails in the horizontal or vertical positions as required. Rockwell Automation Publication PD-T8824 Issue 5 5

2. Installation Trusted 40 Channel 120 Vac Digital Input FTA Page intentionally left blank 6 Issue 5 Rockwell Automation Publication PD-T8824

Trusted 40 Channel 120 Vac Digital Input FTA 3. Associated Cable Selection 3. Associated Cable Selection Refer to the product descriptions detailed below: PD-TC000 PD-TC200 Trusted Power Cables Trusted I/O Companion Slot Cables Rockwell Automation Publication PD-T8824 Issue 5 7

3. Associated Cable Selection Trusted 40 Channel 120 Vac Digital Input FTA Page intentionally left blank 8 Issue 5 Rockwell Automation Publication PD-T8824

Trusted 40 Channel 120 Vac Digital Input FTA 4. Cable Capacitance 4. Cable Capacitance With long field cables the capacitive coupling of the cable can cause a significant voltage to be seen at the T8424 input when the field switch is open. This causes the T8424 to report that the field switch is still on when it is turned off. Revision E T8824 FTAs have lower loop resistance, which reduces the capacitive noise and increases the available loop length. The table below shows some estimated maximum lengths for different cables and mains supplies. Practical distances will be less than this due to other noise and for switching safety margins. Revision E Earlier revisions 15 pf/m, 110 V, 50 Hz 2940 m 890 m 30 pf/m, 110 V, 50 Hz 1470 m 470 m 15 pf/m, 110 V, 60 Hz 2450 m 790 m 30 pf/m, 110 V, 60 Hz 1220 m 390 m 15 pf/m, 120 V, 50 Hz 2620 m 850 m 30 pf/m, 120 V, 50 Hz 1310 m 420 m 15 pf/m, 120 V, 60 Hz 2190 m 700 m 30 pf/m, 120 V, 60 Hz 1090 m 350 m Table 1 Theoretical maximum cable lengths Rockwell Automation Publication PD-T8824 Issue 5 9

4. Cable Capacitance Trusted 40 Channel 120 Vac Digital Input FTA Page intentionally left blank 10 Issue 5 Rockwell Automation Publication PD-T8824

Trusted 40 Channel 120 Vac Digital Input FTA 5. Assembly Pinout Connections 5. Assembly Pinout Connections 5.1. AC TB1 Connections Pin Service 1 120 Vac Live 2 120 Vac Live 3 120 Vac Neutral 4 120 Vac Neutral Table 2 AC TB1 Connections 1 TB1 L L N N 4 Figure 3 AC TB1 Connections 5.2. Field TB1 Connections Pin Loop Power terminal Signal terminal 1 Channel 1 Channel 1 2 Channel 2 Channel 2 3 Channel 3 Channel 3 4 Channel 4 Channel 4 5 Channel 5 Channel 5 Rockwell Automation Publication PD-T8824 Issue 5 11

5. Assembly Pinout Connections Trusted 40 Channel 120 Vac Digital Input FTA Pin Loop Power terminal Signal terminal 6 Channel 6 Channel 6 7 Channel 7 Channel 7 8 Channel 8 Channel 8 Table 3 Field TB1 Connections 5.3. Field TB2 Connections Figure 4 Field TB1 Connections Pin Loop Power terminal Signal terminal 1 Channel 9 Channel 9 2 Channel 10 Channel 10 3 Channel 11 Channel 11 4 Channel 12 Channel 12 5 Channel 13 Channel 13 6 Channel 14 Channel 14 7 Channel 15 Channel 15 8 Channel 16 Channel 16 Table 4 Field TB2 Connections 12 Issue 5 Rockwell Automation Publication PD-T8824

Trusted 40 Channel 120 Vac Digital Input FTA 5. Assembly Pinout Connections 5.4. Field TB3 Connections Pin Loop Power terminal Signal terminal 1 Channel 17 Channel 17 2 Channel 18 Channel 18 3 Channel 19 Channel 19 4 Channel 20 Channel 20 5 Channel 21 Channel 21 6 Channel 22 Channel 22 7 Channel 23 Channel 23 8 Channel 24 Channel 24 5.5. Field TB4 Connections Table 5 Field TB3 Connections Pin Loop Power terminal Signal terminal 1 Channel 25 Channel 25 2 Channel 26 Channel 26 3 Channel 27 Channel 27 4 Channel 28 Channel 28 5 Channel 29 Channel 29 6 Channel 30 Channel 30 7 Channel 31 Channel 31 8 Channel 32 Channel 32 5.6. Field TB5 Connections Table 6 Field TB4 Connections Pin Loop Power terminal Signal terminal Rockwell Automation Publication PD-T8824 Issue 5 13

5. Assembly Pinout Connections Trusted 40 Channel 120 Vac Digital Input FTA 1 Channel 33 Channel 33 2 Channel 34 Channel 34 3 Channel 35 Channel 35 4 Channel 36 Channel 36 5 Channel 37 Channel 37 6 Channel 38 Channel 38 7 Channel 39 Channel 39 8 Channel 40 Channel 40 5.7. TBG1 Connections Table 7 Field TB5 Connections Pin Service 1 0 V 2 Channel 1 3 Channel 2 4 Channel 3 5 Channel 4 6 Channel 5 7 Channel 6 8 Channel 7 9 Channel 8 10 Not used Table 8 TBG1 Connections 5.8. TBG2 Connections Pin Service 14 Issue 5 Rockwell Automation Publication PD-T8824

Trusted 40 Channel 120 Vac Digital Input FTA 5. Assembly Pinout Connections 1 0 V 2 Channel 9 3 Channel 10 4 Channel 11 5 Channel 12 6 Channel 13 7 Channel 14 8 Channel 15 9 Channel 16 10 Not used Table 9 TBG2 Connections 5.9. TBG3 Connections Pin Service 1 0 V 2 Channel 17 3 Channel 18 4 Channel 19 5 Channel 20 6 Channel 21 7 Channel 22 8 Channel 23 9 Channel 24 10 Not used Table 10 TBG3 Connections Rockwell Automation Publication PD-T8824 Issue 5 15

5. Assembly Pinout Connections Trusted 40 Channel 120 Vac Digital Input FTA 5.10. TBG4 Connections Pin Service 1 0 V 2 Channel 25 3 Channel 26 4 Channel 27 5 Channel 28 6 Channel 29 7 Channel 30 8 Channel 31 9 Channel 32 10 Not used Table 11 TBG4 Connections 5.11. TBG5 Connections Pin Service 1 0 V 2 Channel 33 3 Channel 34 4 Channel 35 5 Channel 36 6 Channel 37 7 Channel 38 8 Channel 39 9 Channel 40 16 Issue 5 Rockwell Automation Publication PD-T8824

Trusted 40 Channel 120 Vac Digital Input FTA 5. Assembly Pinout Connections Pin Service 10 Not used Table 12 TBG5 Connections Rockwell Automation Publication PD-T8824 Issue 5 17

5. Assembly Pinout Connections Trusted 40 Channel 120 Vac Digital Input FTA Page intentionally left blank 18 Issue 5 Rockwell Automation Publication PD-T8824

Trusted 40 Channel 120 Vac Digital Input FTA 6. Specifications 6. Specifications Voltage Range Fuses Maximum Current (Field Supply) Power Consumption (Field Supply) Operating Temperature Non-operating Temperature Relative Humidity range (operating, storage and transport) 0 Vac to 150 Vac 40-off 50 ma 6 ma per channel 0.650 W per channel 0 C to +60 C (+32 F to +140 F) -25 C to +70 C (-13 F to +158 F) 10 % 95 %, non-condensing Environmental Specifications Refer to Document 552517 Dimensions Height Width Depth 111 mm (4.4 in) 335 mm (13.2 in) 51 mm (2 in) Weight 900 g (2 lb) Rockwell Automation Publication PD-T8824 Issue 5 19