Turnout Decoder TD Maxi. User Manual - version 0.1.6

Similar documents
Atlas Drop In Decoder

TM Load-regulated locomotive decoder

DR4018 DIGISWITCH HANDLEIDING / MANUAL BEDIENUNGSANLEITUNG / MANUEL. DR4018 DIGISWITCH (v1.2) V1.2 ( )

POINTS POSITION INDICATOR PPI4

CAMTO LTD. Arc detecting system DC/AC

Modellbahn Digital Peter Stärz

Manual for the NMRA compatible DCCaccessory

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Light-It Decoder p/n Lighting decoder w/built-in white LED

HS-509 VIBRATION TRIP MODULE

LE1014W & LE1014MP Ultra-Thin Drive-Select DCC Decoder Art. No Version 4.6 April 2003

Light Curtain Type LA

multi-function meters

N14IP Decoder. $29.95 Decoder version 3.5. Direct plug in for Con Cor N-Scale PA1, and other locomotives with DCC 8 pin socket

REGO Start&Go USER MANUAL

Signalist SC1. DCC signal controller user manual Covers configuration for UK signals

Complete Train Control. Run Your Trains, Not Your Track!

Complete Train Control. Run Your Trains, Not Your Track!

Information LG100 Brake Module

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

GAUGEMASTER PRODIGY EXPRESS

LF101XF Six Function DCC Function Only Decoder Art. No February 2007

15 Series - Dimmer

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

LED Backlight for Technics amplifiers

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Dimensions: 1.2 x 2.30 x..375 inches 31 x 59 x 9.5 mm Decoder version 3.5 $ This decoder is rated at 4 Amps

Operating instructions Electronic preset counter Type series 717

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

LE062XF DCC Decoder for Atlas N Scale Locomotives

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

STX Stairs lighting controller.

Complete Train Control. Run Your Trains, Not Your Track!

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Standard RS232 RS ma

RENFE TAF / CP FOGUETE References: & 47023

BLOCK OCCUPANCY DETECTOR

17.2 Setting the slow speed Important advice on ABC Push-pull (shuttle) train control Push-pull operation without

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

Complete Train Control. Run Your Trains, Not Your Track!

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Z14SRP 4 Function Decoder with NMRA 8 pin plug

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

P2KSR Decoder $ Decoder version 3.5. This decoder is designed specifically to fit LifeLike HO Scale 0-8-0, GP7, GP9, GP30 and SD60 locomotives

V6118 EM MICROELECTRONIC - MARIN SA. 2, 4 and 8 Mutiplex LCD Driver

Gamma instabus. Technical product information

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

KNX Dimmer RGBW - User Manual

SW9SR Decoder $ Decoder version 3.5. This decoder is designed for easy installation in Lifelike Proto 2000 SW8/SW9/SW1200 Locomotives

Operating Instructions

Dimming actuators GDA-4K KNX GDA-8K KNX

Special Applications Modules

APPLICATIONS. Automatic warehouse. Trasportation lines

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

Digital Ratio Controller

MRC DISPATCHER TRACKSIDE DECODER

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Single cable multiswich programmer PC102W

M-relays, 2, 3 or 4 pole, 7-12 A Datasheet

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Electrical connection

Single Axis Position Controller

Absolute Encoders Multiturn

EZCOM-1. PLC - to - AMS MESSAGE DISPLAY INTERFACE INSTALLATION AND OPERATING INSTRUCTIONS. Rev March, 2001

Decoder version 3.5. Plug and play decoder for N-Scale Atlas Classic Series GP7, GP9, GP30, GP35

Quick Start Guide. For Bachmann Large Scale Thomas & Friends Sound-Equipped Locomotives. DCC Sound Technology by SoundTraxx

Operating Instructions

User Guide. HDMI Fiber Optic Extender. DVI-7350a

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

LAUREL ELECTRONICS, INC.

K-BUS Dimmer Module User manual-ver. 1

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Assembly. Front view. LEDs. Parametrization interface. Power Bus

LED Interior Lighting Sets Instruction Manual (380mm)

Manual for the NMRA compatible DCC- DIY accessory decoder. WDecN-90

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Speed sensor MiniCoder GEL 2471

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

02/11/2015

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

Magnecraft Power Relays

Registers type ILR7XX and ILR7XXT

Blackstone Models Open Platform Passenger Coach and Long Caboose Lighting Decoder Technical Reference

Process Transmitter RMA 422

SPACESCAN SERIES SS 02

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Transcription:

Turnout Decoder TD Maxi - version by

Copyright 2013 Tehnologistic SRL All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, without the written permission of SC Tehnologistic SRL Subject to technical modification Please read this manual carefully before carrying out the installation!!! Although our products are very robust, incorrect wiring may destroy the module! During the operation of the device the specified technical parameters shall always be met. At the installation the environment shall be fully taken into consideration. The device must not be exposed to moisture and direct sunshine. A soldering tool may be necessary for the installation and/or mounting of the devices, which requires special care. During the installation it shall be ensured that the bottom of the device should not contact with a conductive (e.g. metal) surface! Page 2 of 24

Content 1. Features... 3 2. Tehnical specification... 4 3. Overview... 4 4. Connections and setup... 5 5. Addressing and programming... 12 6. Advanced functions... 14 7. Table of decoder CVs... 18 8. Accessory decoder addresses... 22 1. Features - DCC accessory decoder - usable in any NMRA compatible DCC system - block address in the range 1-512 (or 0-511) - protection against short circuit and overheating - decoder reset by entering any numerical value in CV8 - switching reversal by CV38 - save the last state - duration of output On state programmable in CV3, CV4, CV5, CV6 - programming address mode or continuous programming - DCC command buffer, for sequential switching Page 3 of 24

2. Technical specification -power supply: DCC signal (from the rails) 9-24Vdc or 17Vac at the AC/DC power connector -total consumption, no activated outputs: <50 ma -maximum output current: 200 ma -maximum pulse current per output: 4000 ma -dimensions: 65 x 85 x 25 mm -weight: 100 g -class of protection: IP00 -operating temperature: 0 to +60 º C -storage temperature: -20 to +60 º C -moisture: max 85% 3. Overview The TD Maxi decoder by tom is a DCC accessory decoder and can drive 4 turnouts with two electromagnets or with motor drive. It can also be successfully used to drive various accessories: electromagnetic relays, LEDs or incandescent bulbs, etc. The particularity and originality of the decoder is the use of a group of capacitors as an electric charge battery (CDU Capacitor Discharge Unit). With this circuit you can greatly reduce the electrical shock experienced in digital systems when switching a turnout with high power consumption. Capacitors help to create a current pulse for a safer and steady switching. The charging current of the capacitors is constant, without adverse effects for the system (this constant current can be set by CV41). More than that, the start of the charging operation can be delayed randomly after the power up, so in the case of using several TD Maxi decoders on the same layout, the DCC system will be not overloaded at the power on sequence. Page 4 of 24

4. Connections and setup Make sure that the turnout or circuit to be connected to the decoder is not powered. Installing under voltage can destroy the decoder. Power option jumpers Programing Push-button AC/DC AC/DC DCC DCC BCA Port1 BCA Port2 BCA Port3 BCA Port4 Connection of the 4 ports (3 terminals each): Status LEDs B C A solenoid terminal corresponding to the branch position (RED wire) (V +) common (positive) terminal of the solenoid solenoid terminal corresponding to direct position (GREEN wire) Page 5 of 24

By factory settings the connection to the DCC signal can be done by connecting rail wires to contacts AC/DC or DCC contacts (they are internally connected). Using a separate power supply You can also use an external power supply or transformer - in this case it is necessary to interrupt jumpers J1 and J2. Powering will be done by AC / DC contacts, and connecting the decoder to DCC signal will be done by DCC contacts. Jumpers J1 and J2 are market on the PCB of the decoder Supply voltage: We recommend using a common 16V transformer. Even if the supply voltage of the decoder may vary within relatively wide scale, you must take into account that not all turnouts operates from 12V - some requires voltages of 16Vdc. Page 6 of 24

Warning! Output voltage (Vdc) = input voltage (peak) - 2V. For AC mains transformer: peak voltage (dc) = output voltage transformer (ac) x 1.42 Meaning of the status LEDs: Status LED color Green (cont) Green (blinking) Red (cont) Red (blinking) Normal operation Decoder in programming mode CDU Charging Error, short-circuit or other malfunction If external power supply is used, the decoder CVs can t be read out, only programmed. In this case the DCC circuit is optically isolated from the power supply. Page 7 of 24

Connection scheme Connecting the classical electromagnetic turnouts: the decoder can be used both for sustained or pulsed driving mode. Changing the timing of the outputs can be made by altering the CV values. Details about these settings can be found in the programming chapter. Connecting classical (electomechanical) turnouts Connecting high current classical (electomechanical) turnouts Page 8 of 24

Connecting motor driven turnouts: DC motor driven turnouts require a two-wire connection; change of direction is achieved by changing the polarity of the two outputs of the decoder. Using the decoder for this type of driving require altering the factory default CV values. For details see chapter addressing and programming. Connecting motor driven turnouts (Conrad, Tillig) Connecting LEDs: resistors connected in series with LEDs will be used to limit the current (in the picture two resistors of 4.7 kohm are used, their values must be determined according to the supply voltage and the desired current for LEDs) Connecting LEDs Page 9 of 24

Connecting incandescent bulbs: bulbs can be connected directly to the decoder outputs. Please keep in mind the nominal voltage of the bulbs, which must be rated for a higher voltage than the power supply voltage. Connecting incandescent bulbs Connecting electromagnetic relays: we recommend use of protection diodes connected in parallel with the relay coil. The cathodes of these diodes must be connected to the common wire (positive terminal of the decoder). Connecting electromagnetic relays Page 10 of 24

Installing the TD Maxi turnout decoders on the layout can be done with the supplied screws and spacers. For positioning and assembly please refer to the figure below: The TD Maxi decoder turnout should be mounted as close as possible to the electromagnetic gear. The electrical connection to them should be made with stranded wire with a suitable section. Cut the wires strictly to the required length. We recommend the use of conductors with minimum cross section of 0.25-0.5 mm2. Page 11 of 24

5. Addressing and programming The decoder is programmed to address 1 (T0001) by the factory. This address is for the accessory decoders and is not identical with the locomotive addresses. Between the addressing of the Roco system and other NMRA compliant DCC systems, there is an offset of 4 addresses. Address 0001 of the decoder will be interpreted as address 0005 in a Roco system. To program the decoder, it has to be passed into programming mode by switching the programming push button once. The decoder will acknowledge the entering into programming mode by blinking the green status LED. This cycle takes about 30 seconds, after which the decoder returns to normal operation. If within this time we made the programming of the address, the decoder immediately returns to normal operation. Programming the decoder address with a Roco Multimouse: Switch MultiMouse in the turnout command mode with the Loco/Turnout button Select the desired switch address (Txxxx) using function/numerical keys followed by the OK button. Pass the decoder in programming mode in the way described above. Page 12 of 24

Perform a straight/branch switch using the direction buttons of the MultiMouse. The decoder will save the address (Txxxx) and will leave the programming mode. Programming the decoder address with a DCC command station: Switch the command in the turnout command mode and select the address you want to program the decoder Pass the decoder in programming mode Perform a straight/branch switch using the direction buttons of the command station The decoder will save the address and will leave programming mode. Page 13 of 24

6. Advanced functions If you want to customize the decoder by modifying not only the address, but other parameters too, you can do it by changing the values of the CVs specified in the table in Chapter 7. Remove all locomotives or mobile decoders from the rails (decoders in locomotives or carriages) else they will be programmed with the same CV values. CV programming is performed as described in the MultiMouse or command stations manual. To program the decoder, you must switch to programming mode as described in Chapter 5. If you want to program multiple CVs, and you consider the default duration of 30 seconds too short, by writing value 1 in CV40 you can pass decoder in permanent programming mode and you can set all the parameters you want. After programming, write value 0 in CV40, and return to normal programming. If during the permanent programming mode a straight/branch switch operation is executed, the decoder will memorize the transmitted address, and will return to normal operation (will leave the programming mode). You can reload the decoder with the factory default CV values performing a Reset cycle. To do this, program any numerical value in CV8. Page 14 of 24

The TD Maxi decoder is factory configured for the use of classical electromagnetical (coil type) drives (CV33=0), with ON time for each of the 4 port of 200 miliseconds. The ON time can be configured individually for each of the output ports. The ON time for port1 is stated in CV3 (CV4, CV5, CV6 are used for ports 2,3 and 4). The ON time in miliseconds is given by the coresponding CV value multiplied by 20. For example, a CV value of 10 means 10x20=200 miliseconds. In case of using the decoder with devices which requres continues DC voltage (light bulbs, LEDs, relays), the ON time for the corresponding output has to be settled to continuous ON (CV3 or CV4,5,6 has to be programmed with the value 0). The straight/branch switching direction of each port can be changed in CV38. Bits 0 thru 3 corresponds to the output ports 1 to 4. The 0 value of each bit means normal straight/branch switching, while the 1 value to inversed branch/ straight switching. In CV38 the sum of the values of each bit has to be programmed. The resulting effect is inverted switching for the same sent straight/branch command. The CV39 can change the timeout in the normal address programming mode. Throughout the programming mode the green status LED is blinking. The decoder can save the last state (straight/branch). In this case, even if it was not powered, or its position was changed mechanically, after power-on, the turnout switches in the state saved without receiving a command from the command station. This option is not enabled by default; to enable it you must write the numerical value 1 in CV34. Page 15 of 24

For using the decoder with motor type drives (Conrad, Tillig), the CV33 has to be programmed with the value of 1. In this case a 2 wire connection is required. The change between straight/branch direction of the turnout is achieved by changing the polarity of the two outputs of the decoder. The ON time in this case is not user programmable, and has a default value of 6 seconds. This timing is sufficient for all motor type turnouts to reach its end position. The motor type drives have internal limit switches, once they reach the end position, the drive motor will be powered OFF, even if the decoder is still in the ON state. The motor type drive mode activation (CV33=1) for the current software version of the TD Maxi decoder (V3 readable in CV7), is valid for all 4 output ports. Once this mode is activated, all the ports will perform in this mode. The TD Maxi deocoder has an internal overcurrent and over temperature protection which is active by default (CV35 = 1). This can be turned OFF programming CV35 with the value 0. Using the motor type drive mode (CV33=1) for the current software version of the TD Maxi decoder (V3 readable in CV7), the current protection has to be turned OFF. Once an error condition is encountered on any of the outputs of the decoder (overcurrent, overtemperature), the corresponding output will be switched OFF, and its status is recorded in the error CV30, which can be read out. The error condition is displayed with the red status LED which will be continuously ON. Bits 0 thru 7 of the CV30 are assignated to the 8 outputs of the decoder ( 4 ports with 2 outputs each). Bit0 coresponds to port 1, output 1, bit1 to port1 ouput 2, and so on. The 0 value for each bit means no error on the Page 16 of 24

corresponding output, while the 1 value means error encountered since the last clearing operation. The readout value is the sum of bits 0-7. The error status can be cleared, by programming CV30 with the value 0. Between succesive switching of its outputs, the DCU is charged and no command will be executed. To avoid loosing of turnout switching commands transmitted by the command station during the charge period, the TD Maxi decoder has implemented a 16 command waiting list which will be executed in sequence. The constant charging current is selectable between 300 ma (factory default value, CV4 =1), and 150 ma (CV41 = 0). Lower charging current will result in a longer charging time. The activations of the outputs will be performed once the CDU has completelly charged. At the time when the decoder is powered from the DCC system or from an external power source, the CDU is charged. If several units are present on the same layout this can result in a high load of the system, and the command station or boosters could go into over current protection. TD Maxi has implemented a mechanisn to avoid these kind of situations, using an ofsetted waiting state at power up. The power up of the decoders will be made sequentially, one by one in the order of their block address. The offset time between the power on of two decoders can be settled in CV42. Using this algorith, the current load of the system will be kept low at the power ups. For direct address programming of the decoders thry CV1 and CV9, please take a look to chapter 8. Page 17 of 24

7. Table of decoder CVs CV Default Value Value Range Description 1 1 0-63 Base (block) address of the decoder (6 bits) 3 10 0-255 The duration of ON state of the decoder s port1 outputs. Activation time = value CV3 x 20 msec. Example: CV3 = 10, pulse duration = 10 x 20 msec = 200 msec (milliseconds). In case of CV3=0, the output of the port will be permanently ON, while the decoder will receive an activation command to the complementary output of the port 4 10 0-255 The duration of ON state of the decoder s port2 outputs. Activation time = value CV4 x 20 msec. Example: CV4 = 10, pulse duration = 10 x 20 msec = 200 msec (milliseconds). In case of CV4=0, the output of the port will be permanently ON, while the decoder will receive an activation command to the complementary output of the port 5 10 0-255 The duration of ON state of the decoder s port3 outputs. Activation time = value CV5 x 20 msec. Example: CV5 = 10, pulse duration = 10 x 20 msec = 200 msec (milliseconds). In case of CV5=0, the output of the port will be permanently ON, while the decoder will receive an activation command to the complementary output of the port Page 18 of 24

6 10 0-255 The duration of ON state of the decoder s port4 outputs. Activation time = value CV6 x 20 msec. Example: CV6 = 10, pulse duration = 10 x 20 msec = 200 msec (milliseconds). In case of CV6=0, the output of the port will be permanently ON, while the decoder will receive an activation command to the complementary output of the port 7 3 Firmware version (only readable) 8 78 - Manufacturer ID (train-o-matic, only readable). Any numerical value written in the CV will reset the decoder to factory defaults (see Default Value column) 9 0 0-7 Extended block address of the decoder, value between 0 and 7 (3 bits) 30 0 0-255 Error, Short at output (the read out value is the sum of the errors): 1 = short on port 1 output1 2 = short on port 1 output2 4 = short on port 2 output1 8 = short on port 2 output2 64 = short on port 4 output1 128 = short on port 4 output2 Page 19 of 24

33 0 0/1 Coil Type mode/ Motor Type mode) 0=coil type mode 1=motor type mode (outputs active with complementary polarity with 6 second ON time) 34 0 0/1 0 -No save / do not remember the last state 1 - Save / remember last state 35 1 0/1 0-current protection OFF 1-current protection ON 38 0 0-15 Switching direction configuration (straight/branch) for each port of the decoder. CV38 has to be programmed with the sum of the options (values in brackets) Bit 0 = 0(0): Normal switching direction (straight/branch) port 1 = 1(1): Inverted switching direction (branch/straight) port 1 Bit 1 = 0(0): Normal switching direction (straight/branch) port 2 = 1(2): Inverted switching direction (branch/straight) port2 Bit 2 = 0(0): Normal switching direction (straight/branch) port 3 = 1(4): Inverted switching direction (branch/straight) port 3 Bit 3 = 0(0): Normal switching direction (straight/branch) port 4 = 1(8): Inverted switching direction (branch/straight) port 4 Page 20 of 24

39 30 1-255 Duration while the decoder remains in programming mode. Factory value is 30 seconds; after that the decoder exits programming mode 40 0 0/1 0 - Exiting programming mode 1 - Entering continuous programming mode 41 0 0/1 0-charge current of the CDU of 300 ma 1- charge current of the CDU of 150 ma 42 0 0-15 Charge Delay of the CDU after power up of the decoder Charge Delay: 0=200ms, Delay=(value of CV42 + 1)*200ms Page 21 of 24

8. Accessory decoder addresses According to NMRA standards, accessory decoder addresses are organized into groups of four addresses, called block addresses (often called decoder address ). There are a total of 512 block / decoder addresses so we can drive a maximum of 2048 (512 x 4 = 2048) turnouts. Although most digital command stations (including the Roco), displays the individual address of the decoder, for correct address should keep in mind the relationship between the block / decoder address and individual turnout address. The block addresses of the accessory decoders are determined using CV1 and CV9 (in binary CV1 uses 6-bit, resulting decimal values in the range 0-63 and CV9 uses 3 bits, resulting decimal values in the range 0-7). The formula for block/decoder address is: block address = CV1 + 64*CV9 Most decoders contain control circuits for 4-8 turnouts, and the block/decoder address implicitly assign addresses for the 4-8 outputs in consecutive order. The Roco system allows the use of block address 0 and for this reason there is an offset of 4 individual addresses. On the next page we have presented a partial table with individual addresses by CV1and CV9. The full table can be found on our website. Page 22 of 24

Block/ Decoder Address CV9 Value CV1 Value Individual turnout addresses of the TD Maxi ports Port 1 Port 2 Port 3 Port 4 individual addresses 1 0 1 1 2 3 4 2 0 2 5 6 7 8 3 0 3 9 10 11 12 4 0 4 13 14 15 16 5 0 5 17 18 19 20 6 0 6 21 22 23 24....... 60 0 60 237 238 239 240 61 0 61 241 242 243 244 62 0 62 245 246 247 248 63 0 63 249 250 251 252 64 0 64 253 254 255 256 65 1 1 257 258 259 260 66 1 2 261 262 263 264 67 1 3 265 266 267 268 68 1 4 269 270 271 272 69 1 5 273 274 275 276 70 1 6 277 278 279 280....... 125 1 61 497 498 499 500 126 1 62 501 502 503 504 127 1 63 505 506 507 508 128 1 64 509 510 511 512 Page 23 of 24

Copyright 2013 Tehnologistic SRL All rights reserved The information in this document is subject to change without notice train-o-matic and the logo are registered trademarks of SC Tehnologistic SRL www.train-o-matic.com www.tehnologistic.ro Tehnologistic SRL Str. Libertatii Nr. 35A 407035 Apahida, Cluj Romania Tel +40-264-556454 Fax +40-264-441275 Page 24 of 24