CDX series. World s No. 1 Linearity OPTEX FA CO., LTD. New models added. Ultra High-Accuracy Laser Displacement Sensor

Similar documents
1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Cylindrical Photoelectric Sensor CY-100 SERIES

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

Detect Color and Shape for various inspection

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

I-SERIES. A wide lineup of measurement ranges capable of solving many applications, from part differentiation to high precision measurement

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

Photoelectric Sensors E3F2

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

NPN type (Analogue/Voltage/Dual) Laser type. PNP type (Analogue/Voltage/Dual) NPN type (RS422) PNP type (RS422) Pins configuration

L-LAS Series L-LAS-LT-50-SL-... Design. L-LAS Series Laser Line Sensors. Product name:

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Electrical connection

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

LD OEM/LD PDS/LD PeCo

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

Operating Instructions

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

Absolute Rotary Encoder E6CP

L-LAS Series L-LAS-LT-2500-XL. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-2500-XL

RLS Series RLS-GD-20/20 -UV. Design. RLS-GD Series Gloss Detection Sensors. Accessories: (cf. page 9) Product name:

Electrical connection

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Photoelectrics Through-beam Type PA18C.T..., DC

LUT Luminescence scanners: Seeing what no-one else can

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

Electrical connection

ADVANCED ultrasonic sensors with analog output. Dimensioned drawing

L-GAGE Laser Gauging Sensors

SPECTRO Series. SPECTRO-1-30-UV/VIS-9x1. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

Operating instructions Through-beam sensor. OJ51xx laser / / 2010

Type F70AB F70ABPN. Digital display. Simple operation featured

V 180 Series Photoelectric Switches

Safety Light Curtains

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

SPECTRO Series SPECTRO-3-50-COF-...-CL. Design. SPECTRO-3 Series True Color Sensors. Product name:

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

Type SCH94FO. Type SCH94FO. Description

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

Vision Sensor Short Manual

SU17 Series Fiber Optic Sensors

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

Safety Light Curtains GuardShield

IMPAC Infrared Thermometers

SPECTRO Series SPECTRO-1-50-DIL. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

SA1J-F: Full Color Fiber Optic Sensors

Super Side. Sense type

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

SPECTRO Series SPECTRO-3-30-UV. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9-10)

SENSORS S60. Compact Sensors - S60. Extended range of standard One for All photoelectric compact sensors

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

PSM-003. Micro Polarization Controller/Scrambler. User Guide

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

Material: Weight: IP Rating: Cable: Connector:

E3X-DA-S. Digital Fiber Sensors. Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application

W100L: Laser Sensor in Mini- Format

SPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

SPECTRO Series SPECTRO-3-20-COF. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9)

Amplifier for fiber optics. Dimensioned drawing

SPECTRO Series SPECTRO-3-50-FCL-JR. Design. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-FCL-JR (incl. software SPECTRO3-Scope)

Safety Light Curtain C 4000

SPECTRO Series SPECTRO-3-50-UV-JR. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-UV-JR (incl. software SPECTRO3-Scope)

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

Capacitive sensor BCT5-S18-UP6X2T-H1151

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

SPECTRO Series SPECTRO-1-30-UV/UV. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

WF next: Fork sensors for a wide range of applications

LVM LASER VALVE MOTION measurement system LASER-BASED TECHNOLOGY. SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS

OM2000N INSTALLATION MANUAL

L-GAGE LG Laser Gauging Sensors

TSG 90 PATHFINDER NTSC Signal Generator

SPACESCAN SERIES SS 02

Type. NPN output F71R F71G F71B F71W F71RH F71GH F71BH F71WH. Manual setting general-purpose type. Manual setting high-speed type

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Transmitter optics with 9x white light LED (optics cover made of glass)

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Safety Light Curtain Type4 SIL3 PLe

Q3X Laser Contrast Sensor

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

Ø50mm Shaft Multi-Turn Absolute Type

W 190 L: Application-based Laser Technology, the optimum solution for demanding applications

Q3X Laser Contrast Sensor

Linear Array with Intensity Adjustment

5100 Series IF Fiber Optic Links

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Transcription:

Ultra High-Accuracy Laser Displacement Sensor CDX series New models added World s No. 1 Linearity OPTEX FA CO., LTD.

A fusion of ultra high-accuracy and ease-of-use We have accumulated decades of know-how since our first laser displacement sensor was introduced to market, all which have been utilized to achieve the World s No. 1 measurement accuracy. We arrived at a simple configuration by examining various user needs and are able to provide operability by way of a built-in Web server, a new concept for displacement sensors. Featuring a fusion of ultra high-accuracy and ease-of-use, these laser displacement sensors feature an extremely high level of perfection.

Advanced Opto-technology & High-rigidity design Featuring unprecedented linearity thanks to an advanced optical system and highly-rigid body In order to enable ultra high-accuracy measurements to be performed, a specially-designed optical system and rigid body with an independent base unit structure have been adopted. Featuring advanced levels of both accuracy and high speed, causes of errors have been successfully shut out. Ultra High-Accuracy Laser Displacement Sensor CDX Series +/- World s No. 1 Linearity 0.015 % F.S. * For triangulation method diffuse-reflective type displacement sensors. Optex FA examination performed November 2016. Linearity comparison Highly-rigid body structure High rigidity is ensured by providing an independent base unit only to the optical system Light receiving element ATMOS Linearity (%FS) 0.03 0.02 0.01 CDX-W85A Conventional model 0-0.01-0.02-0.03 65 70 75 80 85 90 95 100 105 Featuring the World s No. 1 linearity that easily satisfies the [+/-0.015% F.S.] catalog specification, CDX series models realize measurements with significantly higher levels of accuracy than the conventional model. * Workpiece angle: +/-0, diffuse mode. Refer to P. 10 for measurement conditions. Neo LD lens Emitting part Cylindrical lens Receiving part Neo LD lens Employed for wide spot type. A CDX specially-designed lens featuring a 4-group-4-element structure. High linearity has been realized thanks to a new optical design with low-aberration. *Example with the diffuse-reflective type New algorithm Linearity has been successfully restrained through use of a newly-developed original measurement algorithm. By performing a thorough review of our algorithm, ultra high-accuracy measurements have been achieved. The light receiving lens has been customized to enable light reflected from the measurement target to be focused with high accuracy on the light receiving element. Error-causing spot distortions that arise due to lens aberration have been decreased significantly. Neo LD: Neo Low Dispersion

LASER RADIATION Newly Developed Image Sensor for Highly Accurate, High-speed, and Stable Measurements NEW Newly developed image sensor: ATMOS In order to achieve the World s No. 1 Linearity, ATMOS image sensors were newly developed with a light receiving element featuring a CDX specialized design. By applying the latest technology, accuracy has been increased by 3.3 times* that of the conventional model. ATMOS: Auto Tuning cmos *Comparison between the CDX-W85 and conventional equivalent model Industry first Feedback-free high-speed shutter With conventional image sensors, feedback control to the shutter could not keep up with sudden changes in receiving light levels caused by changes in workpiece colors, momentary inabilities to perform measurements would be caused, resulting in response delays. With newly developed ATMOS image sensors, measurements can be performed without the need for feedback control thanks to an industry-first algorithm. Because momentary inabilities to perform measurements and response delays have been eliminated, real-time measurements are now possible. Stable measurements even with Class 1 lasers Receiving light level Black Appropriate Metal Saturated Saturation level With ATMOS image sensors, stable measurements are possible even with a Class 1 laser thanks to their high level of sensitivity. Even when measuring black workpieces such as tires, highly accurate measurements can be performed without using a high output laser. Stable measurement of black workpieces is possible while ensuring the safety of worker s eyes. When receiving light level changes suddenly Saturation level Workpiece height difference Conventional feedback type Metal ATMOS Appropriate Saturation level Appropriate receiving light level after one sampling period Response delay Real-time measurement Automatic shutter release (light reception ends) when receiving light level saturation occurs means no feedback time AVOID DIRECT EYE EXPOSURE CLASS 3R LASER PRODUCT MAXIMUM OUTPUT : 5mW PULSE DURATION : 6.4ms max. WAVE LENGTH : 658nm MEDIUM : SEMICONDUCTOR LASER LASER APERTURE CLASS 3R LASER PRODUCT AVOID EXPOSURE (IEC 60825-1:2001) Laser radiation is emitted from this aperture. Class 1 Laser class 1: Designed to be inherently safe. Light is collected optically, ensuring a safe level even when the laser is emitted to the human body (eyes and skin). High-speed measurement: Max. sampling period of 12.5 μs (Measuring frequency: 80 khz) With highly sensitive ATMOS image sensors, ultra high-speed shutter speeds are possible as the required exposure time is minimized. Because sampling periods have been reduced to 12.5 μs, 1/8th of the conventional model, these sensors can be utilized for application that require ultra high-speed measurements. 100 μs 100 μs Sampling period 1 8 Large glass height measurement 10 μs 12.5 μs Conventional model CDX *With a sampling period of 12.5 μs, the measurement range will be limited. For details, refer to P. 10. 4

Applications Shape measurement of cam shafts Shape measurement of tires Deflection measurement of large diameter drills Flatness measurement of transmission parts Height inspection of smartphone frames (specular reflection type) Warpage measurement of glass substrates (specular reflection type) 5

Direct Network Connections are Possible without Use of a Controller NEW Direct Ethernet connection Because an Ethernet serial interface is built-in to the sensor head, connection to a network is possible without use of a controller. Not only can the cost of a controller be eliminated, but any worries about securing space for controller installation can also be forgotten. No controller required. Simply add new sensors to the hub. Hub Network Branch connector Power supply Operation is possible by connecting directly to a PC LAN port Of course, connection to a PLC Ethernet port is also possible Branch connector Branch connector Power supply Power supply When Analog/Control Output is Necessary Displacement sensor amplifier unit CDA-M The CDA-M amplifier unit is equipped with an organic EL display on which both Japanese characters and English lettering can be viewed with clarity. Control can be performed using either analog or control outputs, while thickness and height difference measurements can be performed using two sensor heads. Thickness Height difference Model CDA-M Sensor head (CDX series) No. of connectable units Connection type Max. 2 units Amplifier side: M8, 4-pin connector Rating Display Analog current output Control output External input Connection type 4 to 20 ma/f.s. Load impedance 300 Ω or less NPN/PNP open collector (selectable by setting) 3 outputs (Only output 1 available) max. 100 ma / 30 VDC, Residual voltage: 1.8 V or less 2 inputs (Only 1 input available) Cable type: Cable length: 2 m (ø5.8 mm) Supply voltage Dot matrix display 12 to 24 VDC +/-10%, including 10% ripple (p-p) Organic EL panel 128 96 pixels Current consumption Indicators 100 ma or less (at 12 V) Power display: Red/Green, Output 1 to 3 display: Orange (Only output 1 display available) Ambient temperature/humidity -20 to +50 C / 35 to 85% RH (no freezing or condensation) Storage temperature/humidity -20 to +60 C / 35 to 85% RH (no freezing or condensation) Environmental resistance Vibration resistance Shock resistance Protection circuit 10 to 55 Hz; double amplitude 1.5 mm; 2 hours in each of the X, Y, and Z directions Approx. 50 G (500 m/s 2 ), 3 times in each of the X, Y, and Z directions Reverse connection protection Degree of protection IEC standard, IP50 Material Weight Polycarbonate 170 g If using an amplifier unit, some settings for the CDX series cannot be confirmed or changed. For details, see the CDX series user's manual. On the CDX series, CH1 is the only output that can be set and used with an amplifier unit. The CDX series does not support CC-Link communication. The resolution of the analog outputs (shown below) will be lower than that when using Ethernet communication. CDX-L15A/-LW15A: 1 μm, CDX-30A/-W30A: 1 μm, CDX-85A/-W85A: 10 μm, CDX-150A/-W150A: 10 μm 6

NEW Equipped with a Web Server Setup software is unnecessary The CDX series features a new Web server. Using a web browser on the computer connected to the same network, browsing and controlling measured values and setup contents are possible. Use is possible without need for a dedicated computer software. Supported browsers Internet Explorer Ver.11 and above, Google Chrome 49 and above Internet Explorer Google Chrome Main functions Distance monitor Storage Light distribution Simultaneous display for 4 CHs No data logger required Masking of unnecessary areas Mask area: Blue Ambient light With the CDX series, judgment settings can be configured for channels 1 to 4. The measured values for each channel can be displayed at once on a graph, allowing for simple comparison of measurement data. Moreover, monitoring of speed and thickness of transparent objects in addition to displacement is possible simultaneously. Measured values for up to 100,000 points can be stored. By operating using a browser, data can be viewed and CSV files can be downloaded. By monitoring receiving light waveforms, receiving light levels and mounting angle can be confirmed. Thanks to a newly developed mask function, even if there are unnecessary objects or ambient light in the measurement range, those can be masked to enable measurements to be performed free of influence. Other functions Measurement setting I/O setting Device setting Communication setting Product information etc. Internet Explorer and the Internet Explorer logo are trademarks or registered trademarks of Microsoft Corporation in the United States and other countries. Google Chrome and the Google Chrome logo are trademarks or registered trademarks of Google Inc. in the United States and other countries. 7

Lineup Sensor heads Linearity Type Measurement range Spot size Resolution Model Diffuse mode Specular mode Spot 15 +/-1 mm ø30 μm CDX-L15A NEW Specular reflection +/-0.05% of F.S. (+/-1 μm) Wide 30 1000 μm CDX-LW15A Spot 30 +/-5 mm 25.5 +/-3.0 mm ø30 μm +/-0.03% of F.S. (+/-3 μm) CDX-30A NEW Short range Wide Diffuse installation Specular installation 30 1000 μm +/-0.015% of F.S. (+/-1.5 μm) +/-0.04% of F.S. (+/-2.4 μm) CDX-W30A Middle range Spot 85 +/-20 mm 81.5 +/-10 mm ø70 μm 0.25 μm Meas. range 65 to 85 mm: +/-0.018% of F.S.(+/-7.2 μm) Meas. range 85 to 105 mm: +/-0.03% of F.S.(+/-12.0 μm) +/-0.03% of F.S. (+/-6.0 μm) CDX-85A Wide Diffuse installation Specular installation 70 2000 μm +/-0.015% of F.S. (+/-6.0 μm) CDX-W85A Long range Spot 150 +/-40 mm ø120 μm Meas. range 110 to 150 mm: +/-0.03% of F.S.(+/-24 μm) Meas. range 150 to 190 mm: +/-0.04% of F.S.(+/-32 μm) CDX-150A Wide 120 4000 μm +/-0.015% of F.S. (+/-12 μm) CDX-W150A Regarding applicability of Export Trade Control Order enacted by Japanese government for the CDX series Caution CDX series sensor heads are products that are subject to Export Trade Control Order Appended Table 1 2-(12) Measurement devices (including machine tools with a measurement function). Please inquire for details. Model CDX-L15 CDX-LW15 CDX-30 CDX-W30 CDX-85 CDX-W85 CDX-150 CDX-W150 Measurement mode Specular mode Diffuse mode Specular mode Diffuse mode Specular mode Diffuse mode Specular mode Diffuse mode Specular mode Diffuse mode Resolution Sensor head only With amplifier unit 0.01 μm 0.05 μm 1 μm 0.05 μm 0.1 μm 0.1 μm 10 μm 0.2 μm Additional information There is no differentiation for the applicability of CDA series amplifier units and the resolution outputted from amplifiers connected to sensor heads is regulated as shown in the table to the left even if the average number of cycles is increased. 8

Options/Accessories Connectors/Connector Cables Type Specifications Cable length Model Sensor head extension cable Dedicated cable for extension between the sensor head and branch connector. Up to two extention cables can be connected and extended. Robot cable specifications. Sensor side: M12, 8-pin socket Branch connector side: M12, 8-pin plug 2 m 5 m 10 m DSC-1208-G02MA DSC-1208-G05MA DSC-1208-G10MA Ethernet cable Dedicated cable for connecting from the branch connectors to the Ethernet port. Robot cable specifications. Branch connector side: M12, 4-pin socket Host side: RJ45 plug 2 m 5 m 10 m SSL-2J04-G02ME-R SSL-2J04-G05ME-R SSL-2J04-G10ME-R Power supply/ external input cable Power supply/external input cable for connecting to branch connector. Branch connector side: M12, 4-pin socket Power supply/external device side: discrete wire 2 m 5 m DOL-1204-G02M DOL-1204-G05M Branch connector Branch connector for connecting sensor heads and various cables. Included with sensor head. - SYL-1208-G0M Amplifier unit, connector cables for amplifier unit Type Specifications Cable length Model Amplifier unit An amplifier unit to which up to two sensor heads can be connected. Control can be performed using either analog or control outputs, while thickness and height difference measurements can be performed using two sensor heads. 2 m CDA-M Sensor/amplifier connection cable Connector cable for connecting branch connectors and amplifier units. Robot cable specifications. Branch connector side: M12, 5-pin socket Amplifier unit side: M8, 4-pin plug 2 m DSL-1204-G02M Sensor-to-amplifier extension cable Extension cable for connection to DSL-1204-G02M. Robot cable specifications. Sensor/amplifier connection cable side: M8, 4-pin socket Amplifier unit side: M8, 4-pin plug 2 m 5 m DSL-0804-G02M DSL-0804-G05M Please ensure that the overall cable length when an amplifier unit is used is within 10 m (sensor head extension cable + sensor/amplifier connection cable + sensor-to-amplifier extension cable). If using an amplifier unit, some settings for the CDX series cannot be confirmed or changed. For details, see the CDX series user's manual. On the CDX series, CH1 is the only output that can be set and used with an amplifier unit. The CDX series does not support CC-Link communication. The resolution of the analog outputs (shown below) will be lower than that when using Ethernet communication. CDX-L15A/-LW15A: 1 μm, CDX-30A/-W30A: 1 μm, CDX-85A/-W85A: 10 μm, CDX-150A/-W150A: 10 μm 9

Specifications Sensor head (model based specifications) Model CDX-L15A CDX-LW15A CDX-30A CDX-W30A Optical method Specular reflection Diffuse installation Specular installation Diffuse installation Specular installation Measurement range *1 15 +/-1 mm 30 +/-5 mm 25.5 +/-3.0 mm 30 +/-5 mm 25.5 +/-3.0 mm Light source Laser class Spot size *3 Linearity Resolution *4 Repeat accuracy *5 Sampling period Temperature drift Weight Temperature drift Medium Wavelength Maximum output JIS/IEC FDA *2-10 to +40 C +40 to +50 C -10 to +40 C +40 to +50 C Red semiconductor laser 655 nm 0.39 mw CLASS 1 CLASS 1 ø30 μm 30 1000 μm ø30 μm 30 1000 μm +/-0.05% of F.S. (+/-1 μm) +/-0.03% of F.S. (+/-3 μm) +/-0.04% of F.S. (+/-2.4 μm) +/-0.015% of F.S. (+/-1.5 μm) 0.25 μm 0.25 μm 12.5 μs / 25 μs / 50 μs / 100 μs / 200 μs / 500 μs / 1 ms / Auto +/-0.02% F.S./ C +/-0.03% F.S./ C +/-0.01% F.S./ C +/-0.02% F.S./ C +/-0.03% F.S./ C +/-0.1% F.S./ C +/-0.03% F.S./ C +/-0.04% F.S./ C +/-0.04% of F.S. (+/-2.4 μm) Approx. 300 g (including 500 mm connector cable) Approx. 280 g (including 500 mm connector cable) Approx. 280 g (including 500 mm connector cable) Model CDX-85A CDX-W85A CDX-150A CDX-W150A Optical method Diffuse installation Specular installation Diffuse installation Specular installation Diffuse installation Measurement range *1 85 +/-20 mm 81.5 +/-10.0 mm 85 +/-20 mm 81.5 +/-10.0 mm 150 +/-40 mm Light source Laser class Spot size *3 Linearity Resolution *4 Repeat accuracy *5 Sampling period Weight The CDX series sensor heads mentioned above are products to which limits on resolution have been added to enable their non-applicability to Export Trade Control Order Appended Table 1 2-(12) Measurement devices. For applicable products with no limited resolution, refer to P.8. Measurement conditions Medium Wavelength Maximum output JIS/IEC FDA *2 Meas. range 65 to 85 mm: +/-0.018% of F.S. (+/-7.2 μm) Meas. range 85 to 105 mm: +/-0.03% of F.S. (+/-12.0 μm) ø70 μm +/-0.03% of F.S. (+/-6.0 μm) Red semiconductor laser 655 nm 0.39 mw Class 1 Class 1 70 2000 μm ø120 μm 120 4000 μm +/-0.015% of F.S. (+/-6.0 μm) +/-0.03% of F.S. (+/-6.0 μm) Meas. range 110 to 150 mm: +/-0.03% of F.S. (+/-24 μm) Meas. range 150 to 190 mm: +/-0.04% of F.S. (+/-32 μm) 0.3 μm 0.3 μm 12.5 μs / 25 μs / 50 μs / 100 μs / 200 μs / 500 μs / 1 ms / Auto +/-0.01% F.S./ C +/-0.03% F.S./ C Approx. 280 g (including 500 mm connector cable) *1. The measurement range will become narrower when the sampling period is set to the maximum speed of 12.5 μs. Please use by selecting from Near/Center/Far below. Measurement range Model Near Center Far CDX-L15A/-LW15A 14.0 to 14.6 mm 14.4 to 15.4 mm 15.3 to 16.0 mm Diffuse installation 25.0 to 28.1 mm 27.8 to 31.9 mm 31.1 to 35.0 mm CDX-30A/-W30A Specular installation 22.5 to 24.0 mm 22.8 to 27.9 mm 26.7 to 28.5 mm Diffuse installation 65.0 to 77.7 mm 73.5 to 90.8 mm 84.8 to 105.0 mm CDX-85A/-W85A Specular installation 71.5 to 74.3 mm 70.6 to 86.9 mm 81.0 to 91.5 mm CDX-150A/-W150A 110.0 to 134.4 mm 124.8 to 166.3 mm 150.2 to 190.0 mm *2. In accordance with the FDA provisions of Laser Notice No. 50, the laser is classified as Class 1 per the IEC 60825-1:2007 standard. *3. Defined with center strength 1/e 2 (13.5%) at the center of measurement range. There may be leak light other than the specified spot size. The sensor may be affected when there is a highly reflective object close to the detection area. *4. The minimum step that can be identified when the distance between the sensor and target changes one step at a time (when performing moving average 65,536 times) *5. Peak-to-peak value of measured value when measuring in stationary state (when performing moving average 65,536 times) +/-0.015% of F.S. (±12 μm) The measurement conditions are as follows unless otherwise designated: Ambient temperature: 25 C (normal temperature), Supply voltage: 24 VDC, Sampling period: 50 μs, Moving average performed: 256, Median filter: 31, Center of measurement range, Measurement target ([specular reflection: glass] for the 15 mm/30 mm type, [specular reflection: aluminum vapor deposition mirror] and [diffuse reflection: visible light shielding ceramic] for the 85 mm type) Furthermore, the sensor head is fixed in place with an aluminum jig when measurements are performed. 10

Sensor head (common specifications) Supply voltage Current consumption Communication interface External input Indicators Degree of protection Ambient temperature/humidity Storage temperature/humidity Ambient illuminance Vibration resistance Shock resistance Applicable regulations Applicable standards Warm-up time Material EMC Environment Safety 12 to 24 VDC (+/-10%, including ripple) 340 ma (at 12 VDC), 180 ma (at 24 VDC) Ethernet (100BASE-TX) / Corresponding to IEEE1588 Selectable from laser OFF, hold/reset, start storage, and offset Link indicator (green) / power indicator (orange/green/blue/red) IP67 (including connector part) -10 to +50 C / 35 to 85% RH (no condensation or freezing) -20 to +60 C / 35 to 85% RH (no condensation or freezing) Incandescent lamp: 3,000 lx or less, fluorescent lamp: 10,000 lx or less 10 to 55 Hz; double amplitude 1.5 mm; 2 hours in each of the X, Y, and Z directions 50 G (500 m/s 2 ), 3 times in each of the X, Y, and Z directions EMC directive (2014/30/EU) RoHS directive (2011/65/EU), Battery directive (2006/66/EC), China RoHS (Directive No. 32) FDA regulations (21 CFR 1040.10 and 1040.11) *6 EN 60947-5-2:2007 / A1:2012, IEC 60825-1:2007 and 2014 Approx. 30 minutes Housing: Aluminum die-cast, Optical window: Glass *6. Excluding differences per Laser Notice No. 50. I/O Circuit Diagram Connection and Circuit Diagram of Power Supply/External Input Cable DOL-1204-G0xM Blue: 0V 5R5V White: External input (NPN) Main circuit 3R3V Black: External input (PNP) Brown: 24V DC Connection and Circuit Diagram of Amplifier Unit CDA-M With the NPN setting With the PNP setting Brown: 12 to 24V DC Brown: 12 to 24V DC Internal circuit 3.3 V Load Black: Output Yellow: NC Purple: NC Gray: External input Pink: NC Internal circuit Black: Output Yellow: NC Purple: NC Gray: External input Pink: NC Load White: Analog output White: Analog output Analog output evaluation equipment Analog output evaluation equipment Blue: 0V/Analog GND Blue: 0V/Analog GND 11

Dimensions (Unit: mm) CDX-L15A/-LW15A 29 15 75 59.8 Optical axis of receiver 36.4 2-ø4.3 34.8 Link indicator (green) 54.7 90 78 Power indicator (orange/green/blue/red) Optical axis of emitter 15+/-1 Measurement range ø6.5 500 M12, 8-pin connector CDX-30A/-W30A 29 75 (Diffuse installation) 15 66.6 2-ø4.3 Link indicator (green) 61 Optical axis of receiver 69.6 78 Power indicator (orange/green/blue/red) 30 Optical axis of emitter 30+/-5 Measurement range ø6.5 M12, 8-pin connector 500 (Specular installation) 90.7 82.3 15 12.7 41.5 Optical axis of receiver 30 50 78.8 82 Optical axis of emitter 25.5+/-3.0 Measurement range 12

500 (Unit: mm) CDX-85A/-W85A (Diffuse installation) 29 15 75 66.6 M12, 8-pin connector (Specular installation) 10 CDX-150A/-W150A 29 15 Link indicator (green) 61 Optical axis of receiver 13 Power indicator (orange/green/blue/red) Optical axis of emitter 150+/-40 Measurement range ø6.5 M12, 8-pin connector 500 2-ø4.3 Link indicator (green) 61 Optical axis of receiver 69.6 78 Power indicator (orange/green/blue/red) 20 Optical axis of emitter 85+/-20 Measurement range ø6.5 86.1 77.7 9.9 38.8 Optical axis of receiver 20 57 79.1 81 Optical axis of emitter 81.5+/-10.0 Measurement range 75 66.6 2-ø4.3 69.6 78 13

Dimensions (Unit: mm) CDA-M Power indicator (Green/Red) ch2 Display screen B button A button SYL-1208-G0M M8, 4P female connector 22 39 23 ch1 Output indicator (Orange) Arrow buttons 52 34 78 Top cover 33.2 Cable length: 2 m ø5.8 8-wire 0.12 mm 2 10 8.4 9.6 9.6 18.8 36.6 5P female connector Spot Size (Typical Characteristic Data) CDX-L15A CDX-LW15A 800 μm 1000 μm 1200 μm 16 mm 15 mm 16 mm 14 mm 15 mm 14 mm ø50 μm ø30 μm ø50 μm 50 μm 30 μm 50 μm 0 19.8 21.2 22.6 0 19.8 21.2 22.6 CDX-30A CDX-W30A 700 μm 1000 μm 2000 μm ø140 μm ø30 μm ø140 μm 0 25 30 35 140 μm 30 μm 140 μm 0 25 30 35 CDX-85A CDX-W85A 1500 μm 2000 μm 2500 μm ø120 μm ø70 μm ø120 μm 0 65 85 105 120 μm 70 μm 120 μm 0 65 85 105 CDX-150A CDX-W150A 2000 μm 4000 μm 6000 μm ø300 μm ø120 μm ø300 μm 0 110 150 195 300 μm 120 μm 300 μm 0 110 150 195 14

System Configuration Sensor head PC PLC Hub, router If extending the cable Sensor head extension cable CDX-L15A/-LW15A DSC-1208-G02MA DSC-1208-G05MA DSC-1208-G10MA Ethernet cable SSL-2J04-G02ME-R SSL-2J04-G05ME-R SSL-2J04-G10ME-R CDX-30A/-W30A Branch connector (included with sensor head) Power supply/external input cable SYL-1208-G0M DOL-1204-G02M DOL-1204-G05M If using an amplifier Sensor/amplifier connection cable CDX-85A/-W85A DSL-1204-G02M If extending the cable Sensor-to-amplifier extension cable DSL-0804-G02M DSL-0804-G05M Amplifier unit CDX-150A/-W150A CDA-M Ensure that the overall cable length from the power supply to the sensor head is within 30 m, and the number of Sensor Head Extension Cables to be connected must be up to two. Also ensure that the overall cable length when the CDA-M amplifier unit is used is within 10 m. (This length restriction does not apply to the Ethernet cable.) 15

Attention: Not to be Used for Personnel Protection. Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death. These sensors do not include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Please consult our distributors about safety products which meet OSHA, ANSI and IEC standards for personnel protection. Specifications are subject to change without prior notice. Specifications and technical information not mentioned here are written in Instruction Manual. Or visit our website for details. All the warnings and cautions to know prior to use are given in Instruction Manual. 91 Chudoji-Awata-cho Shimogyo-ku Kyoto 600-8815 JAPAN TEL. +81-75-325-1314 FAX. +81-75-325-2936 http://www.optex-fa.com Catalog content accurate as of January 2018. 78021-01-008-1801