Magnecraft Power Relays

Similar documents
Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

Magnecraft Power Relays. Catalog

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

ALLEN BRADLEY TIMING RELAY

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

02/11/2015

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Type Contact form Model

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

A V 50Hz / V 60Hz

Series CT7N Bimetallic Overload Relays

Magnetic and Hydraulic-Magnetic Circuit Breaker

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

MILLITARY SPECIFICATION SHEET

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

AS09..S 3-pole Contactors - Spring Terminals

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Data Sheet Definite Purpose Contactors Ex9CK Series

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Minicontactorrelay,2NO/2NC,DCoperated

Datasheet - SRB301LC 24VAC/DC

relays Electromechanical 2006 /2007

Series CDP2 Definite Purpose Contactors

Solid-State Digital Timer

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Interface Relays and Optocouplers Product group picture

Pluggable interface relays CR-M Miniature relays

GV2ME. Main. Device short name. Device application

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

Ordering details. Approval. Classification

Type: DILM12 10(24VDC) Article No.:

Electronic Timer Control Day Astronomic Electronic Control

High performance circuit breakers

Bulletin 190 IEC Modular Starter System

Series CDP2 Definite Purpose Contactors

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

Model Number Structure

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

M-relays, 2, 3 or 4 pole, 7-12 A Datasheet

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

Type: DILM25 10(24V50HZ) Article No.:

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

GV2P05. Main. Device short name. Device application

10 SERIES. Light dependent relays A

Process Transmitter RMA 422

LoopBack Relay. SGLB363 Series. With Built-in AC Bypass Capacitors / DC LoopBack Relay

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

GV2ME. Main. Device short name. Device application

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Modular pulse operated latching relay 16 A

Digital output modules

LONWORKS Fibre Optic Converter

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay.

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Pluggable interface relays CR-M Miniature relays

Datasheet - SRB-E-201ST

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

GR circuit breaker - hydraulic magnetic, Datasheet

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

AC1036. Definite Purpose Contactors

XT-17M-B relay - Delay-off, 1 C/O, 16 A

Single Point Flow Monitor SW118 SW119

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Absolute Rotary Encoder E6CP

Assembly. Front view. LEDs. Parametrization interface. Power Bus

02/11/2015

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Safety dialogue solutions

Multifunction Digital Timer

MILITARY SPECIFICATION SHEET

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Transcription:

Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These power relays meet UL508 spacing and are directly DIN or panel mountable. S7A22D-24 Feature Standard Class F insulation DIN and panel mount cover Sealed construction, vented Benefit Allows for maximum coil temperature of 55 C (3 F) which is ideal for elevated temperature applications Mounts directly onto DIN rail or panel and provides flexibility to accommodate last minute design changes To resist dust and debris in harsh environments Rated Contact Current Contact Configuration Coil Voltage Coil Resistance (Ω) Standard Part Number 24 Vac 70 S7A22D-24 20 Vac 4250 S7A22D-20 30 A DPST-NO 240 Vac 6500 S7A22D-240 2 Vdc 86 S7D22D-2 24 Vdc 350 S7D22D-24 24 Vac 70 SA22D-24 20 Vac 4250 SA22D-20 30 A (NO) / 3 A (NC) DPDT 240 Vac 6500 SA22D-240 2 Vdc 86 SD22D-2 24 Vdc 350 SD22D-24 All AC coils are rectified. Part Number Explanation Series: Cover: S = Dust cover Contact Configuration: 7 = DPST-NO = DPDT Coil Type: A = AC D = DC Mounting Style: 22D = DIN rail and panel mount cover Coil Voltage: 2 = 2 V 20 = 20 V 24 = 24 V 240 = 240 V Note: Available coil voltages include 2 Vdc, 24 Vac, 24 Vdc, 20 Vac, and 240 Vac. 23

Specifications DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Specifications Part Number S7 S Contact Characteristics Contact Configuration DPST-NO DPDT Contact Material Silver Alloy Thermal (Carrying) Current 30 A 30 A (NO); 3 A (NC) Maximum Switching Voltage 250 Vac / 28 Vdc (Conforming to IEC) Maximum Switching Voltage 300 Vac / 28 Vdc (Conforming to UL) Current Ratings at Voltage (Conforming to IEC) Current Ratings at Voltage (Conforming to UL) Switching capacity Minimum Switching Requirements. (NO) 30 A at 250 Vac; 25 A at 28 Vdc, 00,000 cycles (NO) General Use: 30 A at 277 Vac, 00,000 cycles Resistive: 20 A at 28 Vdc, 00,000 cycles Motor:.0 hp at 20 Vac; 3.0 hp at 240 Vac, 00,000 cycles LRA/FLA : 96 A / 22 A @ 240 Vac (AC coil), 30,000 cycles; 0 A / 25.3 A @ 240 Vac (DC coil), 30,000 cycles Pilot Duty: 720 VA / A300, 6,000 cycles Short Circuit: 5000 Arms @ 240 Vac Tungsten: 0 A at 20 Vac 50/60 Hz, 25,000 cycles; 6 A at 250 Vac 50/60 Hz, 25,000 cycles (NO) 30 A at 250 Vac; 25 A at 28 Vdc, 00,000 cycles (NC) 3 A at 250 Vac; 3 A at 28 Vdc, 00,000 cycles (NO) General Use: 30 A at 277 Vac, 00,000 cycles Resistive: 20 A at 28 Vdc, 00,000 cycles Motor:.0 hp at 20 Vac; 3.0 hp at 240 Vac, 00,000 cycles LRA/FLA : 96 A / 22 A @ 240 Vac (AC coil), 30,000 cycles; 0 A / 25.3 A @ 240 Vac (DC coil), 30,000 cycles Pilot Duty: 720 VA / A300, 6,000 cycles Short Circuit: 5000 Arms @ 240 Vac Tungsten: 0 A at 20 Vac 50/60 Hz, 25,000 cycles; 6 A at 250 Vac 50/60 Hz, 25,000 cycles (NC) Resistive: 3 A at 277 Vac 6,000 cycles; 3 A at 28 Vdc 00,000 cycles Maximum: 7500 VA / 840 W (when mounted with 3 mm gap between 2 relays); 6250 VA / 700 W (when mounted side by side without a gap) Minimum: 70 mw 0 ma at 7 V Coil Characteristics Coil Voltage Range Operating Range (% of Nominal) Average Consumption Drop-out Voltage Threshold 2 240 Vac 2 50/60 Hz; 2 24 Vdc 80% 0% 4 VA -20%/+0% (AC);.7 W -20%/+0% (DC) 5% minimum (AC); 0% minimum (DC) General Characteristics Electrical Life at Rated Load Mechanical Life at No Load (Unpowered) Operate Time (Response Time) at Nominal Coil Voltage Rated Impulse Withstand Dielectric Strength Operating Temperature Range 24 Resistive load: 00,000 cycles, unless otherwise specified under Current Ratings at Voltage Inductive load: See load curves on page 25. 5,000,000 operations 25 ms maximum 4000 V (.2 ms / 50 ms) Between coil and contact: 4000 Vac Between poles: 2000 Vac Between contacts: 500 Vac -40 +55 C ( -40 +3 F) Storage Temperature Range -40 +85 C (-40 +85 F) Vibration Resistance +/- mm (0 35 Hz) and 3 g-n (35 50 Hz) Shock Resistance 0 g-n (in operation) / 30 g-n (not in operation) Weight (Average) 0.082 kg (0.8 oz) Conformity to Standards IEC/EN 680-, UL 508, CSA C22-2 n 4 Product Certifications and UL Listed (E48539), CSA (2582574), CE, RoHS Standards Note: Actual product performance may vary depending on application and environmental conditions. For available standard coil voltages, please refer to the standard part number table on page 23. 2 All AC coils are rectified.

Specifications (continued), Dimensions, DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Specifications (continued) Electrical durability of contacts, IEC ratings Resistive load AC reduction coefficient for inductive load (depending on power factor cos j) Durability (inductive load) = durability (resistive load) x reduction coefficient. Maximum switching capacity on DC resistive load Durability (Number of operating cycles) 0 7 0 6 0 5 0 4 0 2 3 4 5 6 7 8 Switching capacity (kva) Reduction coefficient 0,8 0,6 0,5 0,4 0,3 0, 6 0,4 0,2 Current c 0 0, 0 28 50 00 50 200 250 Voltage c Note: These curves are for reference only and are typical values only. Actual performance is dependant upon the actual load, environment, duty cycle, and other conditions specific to the application. Dimensions inches (millimeters) DPST-NO (2 NO): DPDT (2 CO): 0.35 (8.85).33 (33.7).8 (30) 0.35 (8.85).33 (33.7).8 (30) 0.29 (7.4) 2.05 (52) 0.4 (3.6) 2.35 (59.8) 0.45 (.48) 0.25 (6.3) 0.03 (0.8) 2.70 (68.5) 0.29 (7.4) 2.05 (52) 0.4 (3.6) 0.73 (8.48) 0.45 (.48) 2.35 (59.8) 0.25 (6.3) 0.03 (0.8) 2.70 (68.5) 0.6 (4.5) 0.8 (4.5) 0.36 (9.05).54 (39.05) 0.6 (4.5) 0.8 (4.5) 0.36 (9.05).54 (39.05) DPST-NO (2 NO): DPDT (2 CO): 6 6 2 2 4 24 4 24 8 4 8 4 2 2 7 3 2 22 0 0 A A2 A A2 25

Description SPST-NO, 30 A; SPDT, 30 A (NO) / 5 A (NC) Description The series power relays offer robust performance in applications such as HVAC, motor controls, and alarm systems. WSD52 Feature Standard Class F insulation FLA/LRA and hp ratings Ballast load ratings Small package size Standard Quick Connect terminals Benefit Allows for maximum coil temperature of 55 C (3 F) which is ideal for high temperature applications Capable of handling motor loads Suitable for lighting control applications Ideal for small spaces Simplifies and expedites installation Rated Contact Current Contact Configuration Coil Voltage Coil Resistance (Ω) Standard Part Number 24 Vac 500 SA52-24 20 Vac 3000 SA52-20 30 A SPST-NO 5 Vdc 25 SD52-5 2 Vdc 44 SD52-2 24 Vdc 576 SD52-24 24 Vac 500 S5A52-24 20 Vac 3000 S5A52-20 30 A (NO); 5 A (NC) SPDT 240 Vac 200 S5A52-240 5 Vdc 25 S5D52-5 2 Vdc 44 S5D52-2 24 Vdc 576 S5D52-24 Note: PC mount versions available, please call (847) 44-2540 for more information. Part Number Explanation Series: Cover: S = Sealed dust cover Contact Configuration: = SPST-NO 5 = SPDT Coil Type: A = AC D = DC Contact Material: 2 = Silver alloy Mounting Style: 2 = PC mount 5 = Flanged panel mount Coil Voltage: 24 = 24 Vac 20 = 20 Vac 240 = 240 Vac 5 = 5 Vdc 2 = 2 Vdc 24 = 24 Vdc 0 = 0 Vdc 26

Specifications SPST-NO, 30 A; SPDT, 30 A (NO) / 5 A (NC) Specifications (UL 508) Part Number S S5 Contact Characteristics Contact Configuration SPST-NO SPDT Contact Material Silver Alloy Thermal (Carrying) Current 30 A 30 A (NO); 5 A (NC) Maximum Switching Voltage 300 V Current Ratings at Voltage Resistive: 30 A at 240 Vac 50/60 Hz; 30 A at 28 Vdc, 00,000 cycles Resistive: 30 A at 240 Vac 50/60 Hz (NO); 5 A at 240 Vac 50/60 Hz (NC); 30 A at 28 Vdc (NO); 0 A at 28 Vdc (NC), 00,000 cycles Minimum Switching Requirement Motor: hp at 25 Vac 50/60 Hz; 2 hp at 240 Vac 50/60 Hz,,000 cycles FLA/LRA: 22/98 A (NO) at 20 Vac 50/60 Hz, 30,000 cycles; 30/80 A (NO) at 240 Vac 50/60 Hz, 30,000 cycles Ballast: 0 A at 277 Vac, 6,000 cycles Pilot Duty: 470 VA, 6,000 cycles 00 ma at 2 Vac, 5 Vdc Motor: hp at 25 Vac 50/60 Hz (NO); /4 hp at 25 Vac 50/60 Hz (NC); 2 hp at 240 Vac 50/60 Hz (NO); /2 hp at 240 Vac 50/60 Hz (NC),,000 cycles FLA/LRA: 22/98 A (NO) at 20 Vac 50/60 Hz, 30,000 cycles; 30/80 A (NO) at 240 Vac 50/60 Hz, 30,000 cycles; 2/30 A (NC) at 240 Vac 50/60 Hz, 30,000 cycles Ballast: 0 A at 277 Vac (NO); 3 A at 277 Vac (NC), 6,000 cycles Pilot Duty: 470 VA (NO), 275 VA (NC), 6,000 cycles Coil Characteristics Coil Voltage Range Operating Range (% of Nominal) Average Consumption Drop-out Voltage Threshold 24 240 Vac 50/60 Hz; 5 24 Vdc 80% 20% (AC); 75% 20% (DC) 2.8 VA (AC); W (DC) 0% (AC/DC) General Characteristics Electrical Life at Rated Load Mechanical Life at No Load (Unpowered) Operate Time at Nominal Coil Voltage Dielectric Strength Operating Temperature Range Storage Temperature Range Vibration Resistance Shock Resistance Weight (Average) Product Certifications 00,000 cycles, unless otherwise specified under Current Ratings at Voltage 0,000,000 operations 5 ms Between coil and contact: 2500 Vac; Between contacts: 500 Vac -40 +55 C (-40 +3 F) -40 +85 C (-40 +85 F) 3 g-n, 0 55 Hz 0 g-n 33 g (.6 oz) UL (E4364) Note: Actual product performance may vary depending on application and environmental conditions. For available standard coil voltages, please refer to the standard part number table on page 26. 27

Dimensions, SPST-NO, 30 A; SPDT, 30 A (NO) / 5 A (NC) Dimensions inches (millimeters) Coil Terminals: 0.87 X 0.02 (4.75 X 0.508) Quick Connect Tab Terminals.07 (27.30).09 (27.70) NO COM.72 (43.80).24 (3.60).98 (50.22) Contact Terminals: 0.25 X 0.032 (6.35 X 0.8) Quick Connect Tab Terminals NC 0.07 (.80) Radius for #6 screw 0.08 (2.0) All diagrams are shown from top view SPST-NO SPDT 28

Accessories DIN Rail Adapter, 6-DIN- Description The 6-DIN- DIN rail adapter provides the mounting flexibility needed to mount the Power Relay in a panel board or control box. 6-DIN- Shown with relay Description Function For Use With Relays Packaging Minimum Standard Part Number DIN Rail Adapter Enables the relay to be mounted directly to a DIN rail series relays 0 6-DIN- Dimensions inches (millimeters) 2.57 (65.28).4 (35.73) 0.47 (.94).075 (27.3) 0.465 (.8).09 (27.63) 29