We put you first. And keep you ahead. USES FEATURES. Bulletin SS09040 Issue/Rev. 0.2 (10/14)

Similar documents
RATE INPUTS Input B (Terminal 2) Low speed input designed for contact closures to DC common PHYSICAL. Speed: O-20 Hz Operation Temperature: 0-55 C

FIELD MOUNTED RATE TOTALISER MODEL 202D

Registers type ILR7XX and ILR7XXT

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

02/11/2015

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

McCROMETER. RE100 Electronic Register. Programming Guide

PulseFlow FP100 Pulse to 4 20mA Flow Converter (Flow Rate Transmitter / Totalizer / Indicator)

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Electronic Pulse Counter Combination device

SIGNET 5500 Flow Monitor ENGLISH

INTRODUCTION / DESCRIPTION. Description

FP-QUAD-510. Features. Power Requirement OPERATING INSTRUCTIONS. 4-Axis, Quadrature Input Module

Introduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3

Hour Meters / Timers, electronic

A meter which accumulates pulse counts. Also these counters do not outputs. Cub5 Counter

Operating Instructions

263 Series LED Bargraph Indicator and Controllers

TABLE OF CONTENTS SPECIFICATIONS...1 MOUNTING...3 WIRING...4 THEORY OF OPERATION...6 MILIVOLT INPUT OPTION JUMPER SELECTIONS...7

Eaton Durant. Counters, process instruments and hour meters.

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701

Self--powered Time Counter

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Operating instructions Electronic preset counter Type series 717

Multifunction Digital Timer

DPM 942-FPSI 4-20mA Loop Meter with Programmable Backlighting

GRT SERIES INSTALLATION & OPERATING INSTRUCTIONS

PD6620 Series. Loop Leader Loop-Powered Rate/Totalizers. IECEx.

FLOMAT Electromagnetic Insertion Flowmeter

Smart-Encoder : Optical Incremental

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

Modular Lube Lubrication Systems System Controls

AH-PMP-1DA & AH-1DA Operator's Manual

LAUREL ELECTRONICS, INC.

Electronic converter for level transmitters MT03L Instructions manual

Measure the value of water flow using water flow sensor and DC water pump 12 V interfacing with Arduino uno

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Ordering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features

TABLE OF CONTENTS. Instructions:

800 Displaying Series Flowmeter

Single Axis Position Controller

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

EasyReader Model ER2C

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

EasyReader Model ER4C

EZ Encoder : Optical Incremental (P Series)

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

MT03A Electronic converter for flow rate transmitters

SPA MICROPROCESSOR SPEEDOMETER INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES PAGE 3...OPERATING INSTRUCTIONS PAGE 3...

SPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

SURFACE MOUNT LED LAMP STANDARD BRIGHT 1206 (Reverse Mount)

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

P XGA TFT Monitor. User s Manual

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

MS2540 Current Loop Receiver with RS485 Communication

SURFACE MOUNT LED LAMP STANDARD BRIGHT 1210

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

7 SEGMENT LED DISPLAY KIT

BC104 BATCH CONTROLLER

EDL8 Race Dash Manual Engine Management Systems

Process Transmitter RMA 422

SURFACE MOUNT LED LAMP 0603 (0.8 mm Height)

PC-250. SMD Taped Parts Counter Operator s Manual. ISO 9001:2008 Certified. V-TEK, Incorporated 751 Summit Avenue Mankato, MN USA

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

Installation and Operation Manual. YMP Series Signal Programmer

CFM/CMM Thermo Anemometer

THE ASTRO LINE SERIES GEMINI 4000 INSTRUCTION MANUAL

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

1900/25 Vibration Monitor

Vantageview Loop-Powered Process & Level Meter

Scanning System S-2100

USER MANUAL. EMF Meter. Model EMF510. Additional User Manual Translations available at

CET DOUBLE COUNTER WITH TWO THRESHOLDS LBM62CD. Type: TECHNICAL FEATURES

T775U Series 2000 Electronic Stand-Alone Controller

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

associates APPLICATION GUIDE AG334 Externally powered pulse input Rate Totalisers For models with an 'E' or 'G' suffix

SAUTER flexotron RDT405 Manual

OPERATION NOTES FOR PSIDEX AUDIO PGP-1A PRE-AMPLIFIER DESCRIPTION INSTALLATION

SURFACE MOUNT LED LAMP STANDARD BRIGHT 0606

C-net WIND. User s Guide

Model IQ4-PC User Manual Revision Date:

Data Pattern Generator

DIY KIT MHZ 8-DIGIT FREQUENCY METER

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

INSTALLATION AND OPERATION MANUAL

FRQM-2 Frequency Counter & RF Multimeter

Operating Instructions

multi-function meters

AX 345. Process Indicator with Two Analogue Inputs, Calculations and Programmable Analogue Output. Operating Instructions for Model AX 346


Time meter electronic

Multifunction devices

Transcription:

SPECIFICATIONS / INSTALLATION / OPERATION MEASUREMENT SOLUTIONS MMRT Bulletin SS09040 Issue/Rev. 0.2 (10/14) We put you first. And keep you ahead. Smith Meter TOTALIZER/RATE METER The MMRT is a combination explosion-proof totalizer and rate meter. The unit has two eight-digit totalizers, one being an accumulated non-resettable totalizer and the other being an eight-digit resettable batch totalizer. The non-resettable totalizer can be toggled from the totalizer to the rate meter via a reed switch activated by a magnet located within the explosion-proof housing. The MMRT has a programmable scaler and decimal point which allows the displaying of totals and rate in any engineering terms. USES The MMRT can be used with a variety of meters, including: PRIME 4 meters PD meters with transmitters Turbine meters Mass meters FEATURES Eight-digit non-resettable totalizer Eight-digit resettable totalizer Flow rate indicator (on demand) Explosion-proof Programmable scaler and decimal point CE-compliant TYPICAL APPLICATION The MMRT has the ability to provide a local non-resettable totalizer, a resettable totalizer, and a flow rate indicator on a meter that provides an electronic output. The meters that provide a direct electronic output are the Smith Meter PRIME 4 meter, the mass meter, the turbine meter, and the multi-viscosity turbine meters. This unit can also be used with positive displacement meters that have a transmitter mounted on them. SPECIFICATIONS Accuracy: 100% when operated within specifications Power Internal Battery: 3V, Lithium Life Expectancy: 3 years + Inputs Pulse Input Type: Low speed (contact closures to DC common Speed: 0 to 20 Hz Minimum Low Time: 10 milliseconds Minimum High Time: 40 milliseconds Impedance: 101 K Ω Voltage Thresholds: Low 0 to 0.4 high 2.0 to 28 maximum High 28 Type: High speed (requires a voltage source, i.e., current sourcing sensor or a current sinking sensor used with the provided pullup resistors) Speed: 0 to 10 KHz Minimum Low Time: 80 microseconds

Minimum High Time: 20 microseconds (times are with a 0 to 5.0 volt swing) Input Impedance: 2K Ω above 5 Voltage Thresholds: Low 0 to 1.2 high 2.0 to 28 maximum high 28 Reset Input (Reset Batch Totalizer to Zero) Minimum Low Time: 0.25 to 1.0 second (maintained) Required pulse width varies with count speed, scale factor, and number of digits displayed Voltage Thresholds: Low 0 to 0.4 high 2.0 to 28 Program Enable Input Connection must be made between terminals 1 and 5 LCD Display Totalizers Type: Up counters (lead-zero blanking) Digits: 8 Scaler: 0.0001 to 100.0000 Decimal Point: 5 positions (programmable) Rate Indicator Type: 1/Tau Digits: 4/5 (calculated, 5 displayed with a fixed 0) Scaler: 0.001 to 9999 Decimal point: 5 positions (programmable) Accuracy: ±0.02% Backlight 10-30 @ 30mA max. (derate operating temperature 1 C/volt above 17 ) PA-11 Pulse Repeater For turbine meter applications requiring a preamplifier, an optional PA-11 preamplifier can be fitted within the enclosure. Refer to Bulletin SS02019 for preamplifier specifications. Battery Safety The lithium battery that powers the device contains inflammable materials such as lithium organic solvent, and other chemical ingredients. Explosion or fire may result if the battery is not handled correctly. To avoid an accident, follow these guidelines: Do not open enclosure if the area is known to be hazardous Do not replace batteries in a hazardous area Do not stack or jumble up batteries Do not heat batteries above 95 C Do not disassemble batteries Do not recharge lithium batteries Do not apply pressure to, or deform, batteries Do not solder batteries Do not dispose of batteries in fire Insert battery with correct polarity. Recommended Replacement Batteries Panasonic P/N: CR 2/3A Varta P/N: CR 2/3A Fuji P/N: CR 2/3 8.L Initial Start-Up In a non-hazardous area, remove the protective battery insulating tab between the battery and clip to activate the display. reverse polarity protected ENVIRONMENT Ambient Operating Temperature -20 C to 70 C (-4 F to 158 F) Humidity 60% non-condensing Enclosure UL/CSA/FM/CENELEC FM Standard 3615 CSA Standard C22.2 No. 30 UL Standard 1203 CENELEC Standard EN50014, EN50018 Class I, Division 1 and 2, Groups B, C and D Class II, Division 1 and 2, Groups E, F, and G, EExd IIC, IP66 NEMA 4X 2 Bulletin SS09040 Issue/Rev. 0.2 (10/14)

WIRING DIAGRAMS Terminal Function Operation 1 Ground 2 Input B Count input Use with contact closure to ground up to 20Hz count speed 3 Input A Count input Use with current sensing up to 10KHz count speed 4 Reset Connect to ground to reset totalizer 5 Program enable Connect to ground to enter program 6 Backlight common 7 Backlight power Connect to power to light display 8 Rate and Totalizer Toggle Toggles between the Rate Meter and Totalizer MODELING Code MMRT M Basic Model Designation MMRT Mounting Option Blank - Standalone M - Turbine Meter Mounted w/pa-11 Preamp Bulletin SS09040 Issue/Rev. 0.2 (10/14) 3

Contact Closure Input Solid State Count/Rate Input (Current Sourcing Sensor) Solid State Count/Rate Input (Current Sinking Sensor) Solid State Count/Rate Input (Magnetic Pickup) Backlight Wiring 4 Bulletin SS09040 Issue/Rev. 0.2 (10/14)

Program Mode Enable Remote Rate/Totalizer Toggle Remote Reset Smith Turbine Meter with PA-11 Preamp +12 to 30 Common PA-11 Reluctance Pickup Coil 1.6k Pullup Resistor 1 2 3 4 5 Jumper in Position J2 Bulletin SS09040 Issue/Rev. 0.2 (10/14) 5

Dimensional Outline Inches (mm) Note: 1. Dimensions inches to the nearest tenth (millimetres to the nearest whole mm), each independently dimensioned from respective engineering drawings. 2. Hardware for Smith Meter Turbine Meter Mounting not shown. Operation Count Inputs Separate contact and solid state count inputs are provided. The solid state input (terminal 3) requires a current-sourcing sensor and can count up to 10 khz. Inputs into this terminal are counted on the positive-going edge. Note: When a sourcing signal is applied to terminal 3, a power assist feature of the Courier extends the life of the battery. Terminal 2 is the low-speed, current sinking count input designed to be used with a contact closure to ground. It has a maximum count speed of 20 Hz. Inputs into this terminal are counted on the negative-going edge. Count occurs on the this edge of the pulse (Voltage applied to terminal) Contact Closes Contact Opens Input realized on this edge of the pulse Terminal 3 is pulled down to common. When a sensor output supplies voltage to this terminal, one count is registered on the display. The sourcing signal must supply at least +2.0 but no more than +28. Terminal 2 is pulled up to +3. When a contact closes, pulling the voltage down to.4 or less, one count is registered. 6 Bulletin SS09040 Issue/Rev. 0.2 (10/14)

RUN MODE Count Inputs Two screens are available on each of the totalizers. Totalizer: This 8-digit screen shows the accumulated scaled count inputs. The totalizer has lead-zero blanking. Rate Meter: This 4/5 digit screen shows current flow rate. The totalizer mounted on the top of the unit has been wired as a non-resettable totalizer providing accumulative totals. The bottom totalizer has been wired to two magnetic switches that can be activated with the magnet that is supplied with the unit. The magnetic switch mounted center left when activated will switch the bottom totalizer between the batch totals and the flow rate. There is also a magnetic switch mounted center right which is used to reset the totals on the bottom totalizer. Mounting Screw Press the key to reset the totalizer display to zero. This button has no effect on the rate meter screen. The front panel reset key provides an edge-sensitive (momentary) reset. Note: The Mode, below. Magnetic Switches key may be disabled. See Program After the unit has been set up for operation, the magnetic switches mounted on the left center and right center of the unit provide the same functions as the key and the key. Left Magnetic Switch: Activate to toggle between the totalizer and rate meter screens on the bottom totalizer. Right Magnetic Switch: Activate to reset the bottom totalizer screen to zero. Magnetic Totalizer/Rate Select Switch Magnetic Reset Switch Program Mode To enter the program mode, a connection must be made between terminals 1 and 5 on the back of the totalizers. Screens There are six program mode screens on each of the totalizers. Press and hold the key while repeatedly pressing the key to advance to successive screens. Programming Screens Activate the respective magnetic switch by holding the supplied chain magnet above the switch on the outside of the enclosure. Display Orientation Display orientation can be rotated in 90 degree increments by removing the two mounting screws and 1/4" hex standoffs and repositioning in the optional tapped holes in the base of the housing. Screen Function 1 Count Scale Factor 2 Totalizer Decimal Factor 3 Rate Scale Factor 4 Rate Meter Decimal Point 5 Rate x1/x10 6 Reset Key Enable/Disable Front Panel Keys The front panel keys are accessible when the cover is off the unit. These keys are typically used for setup. Press the key on the front panel to toggle between the totalizer and rate meter screens when the cover is removed from the unit. Bulletin SS09040 Issue/Rev. 0.2 (10/14) 7

COUNT SCALER Calculating the Count Scale Factor The count scale factor is used to convert the incoming count pulses to the desired unit of measure to be displayed (feet, gallons, etc.) or to correct for a known amount of error (wheel wear, viscosity, etc.). This scaler has six digits available with a fixed decimal point. Programming Count Scale Factor The first screen in the program mode is used to enter the count scale factor. Count Scaler Range: 0.0001 to 99.9999 Count Scaler (CS) Formula: where: DPF is the decimal point factor corresponding to the desired decimal point location. DISPLAY DPF DISPLAY DPF XXXXXX = 1 XXX.XXX = 1,000 XXXXX.X = 10 XX.XXXX = 10,000 XXXX.XX = 100 CS = DPF PPI The far right digit will be flashing. Press the until reaching the desired digit value. Note: Pressing and holding the numbers to autoscroll. key key will cause the Next press the key to move the flashing digit one place to the left. Change this digit to the desired value with the key. Repeat this process until all digits are set correctly. (Setting the count scale factor to 0.00000 will allow scaling by 100.) PPI is the number of pulses per item from the sensor (times 2 if doubled count mode). Example 1: A transmitter produces 50 pulses per gallon of product. Calculate the count scaler required to indicate number of gallons per product (XXXXXX). Programming Totalizer Decimal Point The second screen is used to enter the decimal point display on the totalizer screen. Press and hold the key and then press the key to move from screen one to screen two. 1 CS = = 0.02000 50 Example 2: A turbine meter preamp produces 15.8 pulses per liter. Calculate the count scaler required to indicate the number of liters of product that has passed through the meter (XXXX.XX). 100 CS = = 6.3291 15.8 Press the key to move the decimal point to the desired position. (Select the XXXX.XX position on the totalizer decimal point menu.) 8 Bulletin SS09040 Issue/Rev. 0.2 (10/14)

Rate Scaler Calculating the Rate Scale Factor This 1/Tau rate meter calculates rate by measuring the time interval between input pulses, converting to a frequency (F = 1/Tau), and multiplying the product by the rate scaler. The rate scaler is user-programmed to convert the count input frequency into the desired rate units for display (gallons/minute, gallons/hour, liters/minute, cubic meters/hour, etc.). Programming Rate Scale Factor The third program mode screen allows you to enter the rate scale factor. Rate Scaler Range: 0.001 to 9999 Rate Scaler (RS) formula: Sec x DPF RS = for R x 10 PPI x 10 The lower case "d" appears on the right of the display when it is time to enter the decimal point position for the rate scaler. Note: This decimal point is used for the rate scaler only and will not appear on the rate meter screen. where: SEC is the number of seconds in the rate time unit (items/ second = 1, items/minute = 60, items/hour = 3600, etc.). DPF is the decimal point factor corresponding to the desired decimal point location on the run mode screen: Display DPF XXXX 1 XXX.X 10 XX.XX 100 X.XXX 1000 PPI is the number of pulses per item from the sensor. Example 1: A transmitter produces 50 pulses per gallon of product. Display rate in whole gallons per minute (XXXX). Press the key to change the first digit to the correct value. Press the key to select the next digit to be changed. Repeat this process until all the digits are correct. When the "d" appears, press the key until the decimal point is in the desired location. Ratemeter Decimal Point The fourth program mode screen is used to enter the decimal point position for the rate meter run-mode display. The display will show the screen number (4) and four zeros. 60 X 1 RS = = 1.200 50 Example 2: A flow sensor produces 15,800 pulses per cubic meter. Display flow rate in tenths of liters per hour. 3600 x 10 RS = = 2.278 15,800 key until the decimal point is in the cor- Press the rect position. Bulletin SS09040 Issue/Rev. 0.2 (10/14) 9

We put you first. And keep you ahead. Rate x1 or X10 The fifth screen is used to select the rate display multiplier of one or ten. Selecting rate x10 will add a zero to the far right of the display. This zero will not change value and does not affect the decimal point position. The display will show the screen number (5) and a 1 at the right. Front Reset Key Enable/Disable The last screen in the program mode is used to determine whether the front panel reset key will function. The screen will show a number 6 on the left and an R on the right. Press the key to choose the option you want. Press the key to select 1 or 10. Note: The reset terminal on the rear panel is still active when the front reset button is disabled. To exit the program mode, break the connection between terminals 1 and 5. Revisions included in SS09040 Issue/Rev. 0.2 (10/14): New photo and rebrand layout. The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect. Contact information is subject to change. For the most current contact information, visit our website at www.fmctechnologies.com/measurementsolutions and click on the Contact Us link in the left-hand column. www.fmctechnologies.com/measurementsolutions 2014 FMC Technologies. All rights reserved. SS09040 Issue/Rev. 0.2 (10/14) FMC Technologies Measurement Solutions, Inc. 500 North Sam Houston Parkway West, Suite 100 Houston, Texas 77067 USA P:+1 281.260.2190 USA Operation 1602 Wagner Avenue Erie, Pennsylvania 16510 USA P:+1 814.898.5000 Germany Operation Smith Meter GmbH Regentstrasse 1 25474 Ellerbek, Germany P:+49 4101 304.0 10