GSM. (Global System for Mobile Communications) TEST REPORT. according to ETSI EN (v9.0.2) for

Similar documents
EMC Test Report. 850 Kacena Road Hiawatha, IA 52233

TEST REPORT No

FCC TEST REPORT for Aeon Labs LLC. Aeon Minimote Model No.: DS03202B-ZWUS, DS03202W-ZWUS

CENTRE OF TESTING SERVICE INTERNATIONAL

TABLE OF CONTENTS 1. GENERAL INFORMATION PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) TEST STANDARDS TEST METHODOLOGY

Akkreditiertes Prüflaboratorium

ELECTRICAL TESTING FOR:

Testing. Maker Works. Applicant: Model No.: FCC ID: Jun., May to 16. Date of Test: PASS* Test Result: Signature: Authorized. this report.

Shenzhen Zhongjian Nanfang Testing Co., Ltd.

T E S T - R E P O R T. No for. SLG 42 MOBY Component

FCC test report. Via Pezza Alta, 13 I Rustignè di Oderzo (TV)

Akkreditiertes Prüflaboratorium

FCC Part 15 Subpart B Test Report. FCC PART 15 Subpart B Class B: 2014

CONTENTS 1. GENERAL INFORMATION INTRODUCTION PRODUCT INFORMATION DESCRIPTION OF TESTS CHANNEL BANDWIDTH...

Untertürkheimer Str. 6-10, Saarbruecken Phone: +49 (0) Fax: RSC-Laboratory Phone: +49 (0) Fax: -9075

FCC TEST REPORT For. ETI Solid State Lighting (Zhuhai) Ltd. LED downlight Model No.: XX

FCC PART TEST REPORT. HHC Changzhou Corp.

TEST REPORT FROM RFI GLOBAL SERVICES LTD

A Test Lab Techno Corp. FCC. RF Test Report. Product Type. : Mobile Hotspot. Applicant. : Netgear Inc.

FCC PART 22H, PART 24E MEASUREMENT AND TEST REPORT. Shanghai AirM2M Communication Technology Co., Ltd

FCC PART 15 CLASS B MEASUREMENT AND TEST REPORT. Tritech Technology Ltd.

FCC PART 15 TEST REPORT

Final Report on Skycontroller FCC ID: RKXSKYCONTROLLER IC: 5119A-SKYCONTROLLER

Test Report. Product Name: Access Point Model No.: MS-6809 FCC ID: DoC

TEST REPORT FROM RFI GLOBAL SERVICES LTD

FCC PART 15 TEST REPORT

LAB CODE 571- Page No.: of 11 Measurement System Information General Information Testing Condition: Temperature: 5±3 C Humidity: <8% Measurement Facil

T E S T - R E P O R T. No for PC24E-11-FC/R. RF-modem for wireless LAN. Agere Systems Nederland B.V.

R&TTE EMC TEST REPORT

Sunlight Supply, Inc.

Test Report. Model No.: NF592XX-YYYY-ZZ(X,Y & Z: Stands for A-Z & 0-9 ) HBJC1XXF592-YYYY-ZZ (X,Y & Z: Stands for A-Z & 0-9 )

EMC Test Report. Client: Continental Automotive Systems, Inc. Tested by: Fendy Liauw, Engineering Technician

Report No.: CAT-012-1

TS8991 OTA Performance Test System

EMC Test Report. Client: Crestron Electronics, Inc. Tested by: Jeremy O. Pickens, Senior EMC Engineer

R&S DST200 RF Diagnostic Chamber Accurate radiated testing of wireless devices 700 MHz to 6 GHz

Test result 1. Conducted emission EN 55022: A1:2007 EA 3 passed 2. Radiated emission <1GHz (others)

FCC Part 15B Test Report

Shenzhen Zhongjian Nanfang Testing Co., Ltd.

Page: 1 of 19 EMC TEST REPORT EN55024:1998+A2:2003

Final Report on SARA-U260 FCC ID: XPYSARAU260 IC:8595A-SARAU260

SIGFOX END- PRODUCT RADIATED TEST PLAN FOR SIGFOX READY TM CERTIFICATION

TOBY-L200 GSM/UMTS/HSPA/LTE Data Module

Report No.: CAT-012

FCC PART MEASUREMENT AND TEST REPORT FOR. DongGuan City FLYSKY Remote Model Co., Ltd.

CHAO WEI ELECTRONICS CO., LTD. FCC REPORT CHAO WEI ELECTRONICS CO., LTD.

FCC Report. Beijing Visual World Technology Co.,Ltd.

FCC REPORT Q6WBT * In the configuration tested, the EUT complied with the standards specified above.

FCC Report (WIFI) Shenzhen Reo-link Digital Technology Co., Ltd B509, University Town Business Park LiShan Road, NanShan, Shenzhen, Guangdong, China

FCC PART 15B, CLASS B TEST REPORT. Autel Intelligent Tech. Corp., Ltd.

Test Report #: Date: January 24, 2006

FCC PART TEST REPORT SHANGHAI MERIT TECHNOLOGY CORP.

Order Number : GETEC-C FCC Part 15 subpart B Test Report Number : GETEC-E Page 2 / 32 CONTENTS

CONTENTS 6.2 TEST SET-UP...16

FCC ID: IMK-ILCISA EMI TEST REPORT

CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC FCC ID TEST REPORT

FCC Part 15 Certification Test Report. 433 MHz Alarm System

REPORT Datum/Date Beteckning/Reference Sida/Page

Complimentary Reference Material

FCC Report (WIFI) Shenzhen SDMC Technology Co., Ltd 2AFC2-STB-1HD. * In the configuration tested, the EUT complied with the standards specified above.

THRU Lab & Engineering , Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do, , Korea T /F

FCC Test Report (Class II Permissive Change)

FCC REPORT. Report Reference No... : TRE R/C.: Simbans Picasso 10 Inch Tablet

THRU Lab & Engineering , Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do, , Korea T /F

FCC Test Report. Color LCD Monitor

EMC TEST REPORT. Product : Digital Camcorder Model No. : SCD5000. SAMSUNG ELECTRONICS Co., Ltd. EMC Test Laboratory. Project No.

FCC Report (WIFI) Red Bear Company Limited. RedBear IoT phat 2ABXJ-PHAT-IOT

FCC TEST REPORT D-LINK CORPORATION

TEST REPORT. REPORT NUMBER: B15W50007-FCC-RF_Rev4

Radio Frequency (RF) - Exposure TEST REPORT No.: c. for u-blox AG. RF-Module LISA-U FCC-ID: XPYLISAU200 IC-ID: 8595A-LISAU200

Final Report on WLAN tranceiver INARI5-WLAN-1

R&S FSW-K144 5G NR Measurement Application Specifications

Report On. FCC Testing of the Pace Plc 16x4 Hybrid Gateway Cable Set Top Box COMMERCIAL-IN-CONFIDENCE

Date: ESPOO Page: 1 (10) Appendices. Tyre Pressure Monitoring Device. Flextronics International Finland.

TEST REPORT. Test Report No. : UL-RPT-RP C V2.0. Date of Issue: 06 March 2018

Page: 1 of 15 FCC TEST REPORT. : MEGAVIEW DIGITECH LIMITED : C Fu Gui Yuan, Block 80, Bao an District, Shenzhen, China

APPLICATION OF CERTIFICATION For. TTE Technology Inc. LCD TV FCC ID: W8ULE32HDE3000

STC (Dongguan) Company Limited EC VERIFICATION OF COMPLIANCE EMC-D163584VOC

EUTRA/LTE Downlink Specifications

FCC Test Report (Part 15C) WPT

TEST REPORT. iphone Hi-Fi Audio cable Adapter with Lightning female connector Model No.:

R&S ZN-Z154 Calibration Unit Specifications

R&S DST200 RF Diagnostic Chamber Specifications

TEST REPORT. Issued for:

TEST REPORT. Test report no.: / A. Test standard/s

R&S CONTEST ITS Test cases and applications

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

Item tested : Tivoli Audio Model DAB. Type of equipment : DAB and FM radio. Client : Post- og teletilsynet

Guangzhou Panyu Juda Car Audio Equipment Co.,Ltd. Bluetooth Speaker. Model Number: UB-SPB4M-101 FCC ID: ESXSPB4M

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

Out of Band Spurious Measurement for Bluetooth Modules

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Guangzhou Panyu Juda Car Audio Equipment Co.,Ltd. CD/USB RADIO. Model Number: TY-CWU700

TEST REPORT. Test Report No. : UL-RPT-RP JD18L V2.0. Manufacturer : Neeo AG. Model No. : 6336-BRAIN FCC ID : 2AKK7-BR633601

T E S T R E P O R T No.: T03b. for. Telit Communications S.p.A

FCC Test Report (Class II Permissive Change)

e2b calibration 521 Fifth Avenue Chardon, Ohio Phone: Fax: Certificate Of Calibration

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of NYNE MULTIMEDIA INC. Bluetooth Speaker. Model Number: NYNE VIBE FCC ID: AWA-NYNEVIBE

TEST REPORT CHOMERICS R&D. PREMIER EMI Shielding Thermoplastic Face Plate Shielding Effectiveness 84 DRAGON COURT WOBURN, MA 01801

Model AS40030, -RS, -RE AR System 10kHz-40GHz

EMC REPORT. Shenzhen Sunchip Technology Co., Ltd. * In the configuration tested, the EUT complied with the standards specified above.

Transcription:

THIS TEST REPORT IS NOT INTENDED FOR PTCRB OR CTIA CERTIFICATION! GSM (Global System for Mobile Communications) TEST REPORT Number: 6-0541-14-1-2b - Date: 2014-06-04 according to ETSI EN 301 511 (v9.0.2) for Philips Lighting B.V. User Equipment Type: City Touch OLC Final Hardware Version: - Final Software Version: - - supporting the following technologies: GSM 900/1800 This test report consists of 9 pages and the following annexes: Annex A - Accreditation Certificate Annex B - Test Equipment Annex C - Photographs Annex D - Detailed Test Verdicts Annex E - Measurement Results 2 pages 5 pages 3 pages 6 pages 8 pages CETECOM GmbH is accredited according to DIN EN ISO/IEC 17025 by: CETECOM GmbH 45219 Essen Germany Phone: +49 (0) 2054 9519-0 Fax: +49 (0) 2054 9519-220 E-mail: info@cetecom.com http://www.cetecom.com Registered in Essen, Germany, Reg.-No.: HRB Essen 8984 Managing Directors: Wilfried Klassmann (CEO), Jens Passe TOM 1.8.4.1

GSM Test Report No. 6-0541-14-1-2b Date of Report: 2014-06-04 TOM 1.8.4.1 Page 2 of 9 Contents 1. TEST RESULTS 1.1. Summary of Test Results 1.2 Type of this CETECOM GSM Test Report with Test Conclusion 1.3. Documentation Received from the Client/Manufacturer 1.4. Validity of Test Results 2. ADMINISTRATIVE DATA 2.1. Identification of the Responsible Testing Laboratory 2.2. Identification of the Testing Location(s) 2.3. Organizational Items 2.4. Identification of the Client 2.5. Identification of the Manufacturer 2.6. Identification of the Person responsible for Placing the Product on the Market 3. EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE) 3.1. Identification of the Equipment Under Test 3.2. Front View of the Equipment Under Test 3.3. Identification of all Used Test Samples of the Equipment Under Test 3.4. Identification of the Ancillary Equipment 4. APPLIED REFERENCE DOCUMENTS 4.1. Leading Reference Documents for Testing 4.2. Specific Reference Documents for Testing Annex A - Accreditation Certificate Annex B - Test Equipment Annex C - Photographs Annex D - Detailed Test Verdicts Annex E - Measurement Results

GSM Test Report No. 6-0541-14-1-2b Date of Report: 2014-06-04 TOM 1.8.4.1 Page 3 of 9 1. Test Results 1.1. Summary of Test Results The following table summarizes the final test results of the tested user equipment. Detailed test results for each test case including the used/subcontracted testing location (according to sec. 2.2) are documented in Annex E of this test report. An explanation of the terms used for each column in the table is given below. Table 1: Summary of Test Results Amount of Test Cases GSM 900 GSM 1800 No. Description PASS FAIL INC PASS FAIL INC 3GPP TS 51.010-1 12 Transceiver 2 0 0 2 0 0 13 Transmitter 0 0 0 0 0 0 14 Receiver 0 0 0 0 0 0 Total: 2 0 0 2 0 0 The following terms are used in the table above: Specification: Name/Identifier of the used test specification for GSM testing. No.: Test section number of the indicated Mobile Station Conformance Specification. Description: Test section title of the indicated Mobile Station Conformance Specification. PASS: Amount of test cases which are conformant to the applied standards in the given GSM frequency band. FAIL: Amount of test cases which are not conformant to the applied standards in the given GSM frequency band. INC: Inconclusive: Amount of test cases with ambiguous results to the applied standards in the given GSM frequency band.

GSM Test Report No. 6-0541-14-1-2b Date of Report: 2014-06-04 TOM 1.8.4.1 Page 5 of 9 2. Administrative Data 2.1. Identification of the Responsible Testing Laboratory Company Name: Department: CETECOM GmbH Radio Communications & EMC Address: 45219 Essen Germany Telephone: +49 (0) 2054 9519-0 Fax: +49 (0) 2054 9519-220 Responsible Test Lab Manager: Dipl.-Ing. Niels Jeß 2.2. Identification of the Testing Location(s) Company Name: CETECOM GmbH Address: 45219 Essen Germany 2.3. Organizational Items CETECOM Reference No.: 6-0541-14-1 CETECOM Order No.: NLYX-4515304891 CETECOM Test Manager Dipl.-Ing. Ninovic Perez CETECOM Project Manager: Dieter Franke Start of Testing: 2014-05-26 End of Testing: 2014-05-27

This Report shall not be reproduced except in full without the written approval of CETECOM Copyright All rights reserved by CETECOM GSM Test Report No. 6-0541-14-1-2b Date of Report: 2014-06-04 Tom 1.8.4.1 Page 6 of 9 45219 Essen Germany 2.4. Identification of the Client Company Name: Philips Lighting B.V. Address: High Tech Campus 45 5656 AE Eindhoven Netherlands Contact Person(s): Koen Schepers Telephone: +31402794768 2.5. Identification of the Manufacturer For Power Box LLC 7240 Manufacturer s name: Address: For Comm Box LLC 7250 & LLC 7251 Manufacturer s name: Tamura Electronics Shenzhen Co, Ltd, 3014, Ban Xue Gang Street, Ban Tian Community, Ban Tian Subdistrict, Long Gang District Shen Zhen City, China Mitac Computer (KunShan) Co., Ltd, Address: No. 269, 2nd Avenue, District A, Comprehensive Free Trade Zone, Kunshan, Jiangsu, China 2.6. Identification of the Person responsible for placing the Product on the Market Company Name: Philips Lighting B.V. Address: High Tech Campus 45 5656 AE Eindhoven Netherlands Contact Person(s): Koen Schepers Telephone: +31402794768 Note: This data is based on the client s information.

GSM Test Report No. 6-0451-14-1-2b Date of Report: 2014-06-04 TOM 1.8.4.1 Page 7 of 9 3. Equipment Under Test (EUT) and Ancillary Equipment (AE) 3.1. Identification of the Equipment Under Test Brand Name: Philips Innovation Services Type Name: City Touch OLC Marketing Name: City Touch OLC GSM Frequency Bands: GSM 900/1800 Special Features / Comments: 3.2. Front View of the Equipment Under Test

This Report shall not be reproduced except in full without the written approval of CETECOM Copyright All rights reserved by CETECOM GSM Test Report No. 6-0541-14-1-2b Date of Report: 2014-06-04 Tom 1.8.4.1 Page 8 of 9 45219 Essen Germany 3.3. Identification of all used Test Samples of the Equipment under Test EUT ID * Serial Number Hardware Version Software Version EUT1: Philips Power Box LLC7240 9137 003 608 DT00000000E0 - - EUT2: Philips Comm Box LLC7251 9137 003 607 Variant A: Philips Comm Box LLC7250 9137 003 606 IMEI 358945040504015 - - No tests performed with variant *) The Equipment under Test Identifier (EUT ID) is used to simplify the identification in this Test Report. 3.4. Identification of the Ancillary Equipment AE ID * Name, Description Serial- Number HW Status SW Status AE1 Lamp Driver VA1400063 9290008846 -- -- AE2 LED Panel Banshi Load V3 -- -- -- AE3 Cooling Element -- -- -- AE4 USB-cable -- -- -- AE5 Power line -- -- -- AE6 Test-PC 04 -- -- -- *) The Ancillary Equipment Identifier (AE ID) is used to simplify the identification in this Test Report. Tests performed with EUT1 + EUT2 +AE1 +AE2 +AE3 +AE4 +AE5 +AE6

GSM Test Report No. 6-0541-14-1-2b Date of Report: 2014-06-04 TOM 1.8.4.1 Page 9 of 9 4. Applied Reference Documents 4.1. Leading Reference Documents for Testing The equipment under test (EUT) has been tested at CETECOM's (own or subcontracted) laboratories according to the leading reference documents given in table 2 below: Table 2: Leading Reference Documents No. Identity Document Title Version/Date [1] ETSI EN 301 511 Global System for Mobile communications (GSM); Harmonized EN for mobile stations in the GSM 900 and GSM 1800 bands covering essential requirements under article 3.2 of the R&TTE directive (1999/5/EC) v9.0.2 (2003-03) 4.2. Specific Reference Documents for Testing Table 3 summarizes specific reference documents such as harmonized standards or test specifications which were used for testing at CETECOM's (own or subcontracted) laboratories. Table 3: Specific Reference Documents ----- No. Identity Document Title Version/Date

THIS TEST REPORT IS NOT INTENDED FOR PTCRB OR CTIA CERTIFICATION! GSM (Global System for Mobile Communications) TEST REPORT Number: 6-0541-14-1-2b - Date: 2014-06-04 for Philips Innovation Services User Equipment Type: City Touch OLC Final Hardware Version: - Final Software Version: - - Annex A: Accreditation Certificate This annex consists of 2 pages CETECOM GmbH is accredited according to DIN EN ISO/IEC 17025 by: CETECOM GmbH 45219 Essen Germany Phone: +49 (0) 2054 9519-0 Fax: +49 (0) 2054 9519-220 E-mail: info@cetecom.com http://www.cetecom.com Registered in Essen, Germany, Reg.-No.: HRB Essen 8984 Managing Directors: Wilfried Klassmann (CEO), Jens Passe TOM 1.8.4.1

GSM Test Report No. 6-0541-14-1-2b Annex A: Accreditation Certificate Date of Report: 2014-06-04 TOM 1.8.4.1 Page 2 of 2 Mobile Communications The annex pages of the certificate may be received from CETECOM on request.

THIS TEST REPORT IS NOT INTENDED FOR PTCRB OR CTIA CERTIFICATION! GSM (Global System for Mobile Communications) TEST REPORT Number: 6-0541-14-1-2b - Date: 2014-06-04 for Philips Innovation Services User Equipment Type: City Touch OLC Final Hardware Version: - Final Software Version: - - Annex B: Test Equipment This annex consists of 5 pages CETECOM GmbH is accredited according to DIN EN ISO/IEC 17025 by: CETECOM GmbH 45219 Essen Germany Phone: +49 (0) 2054 9519-0 Fax: +49 (0) 2054 9519-220 E-mail: info@cetecom.com http://www.cetecom.com Registered in Essen, Germany, Reg.-No.: HRB Essen 8984 Managing Directors: Wilfried Klassmann (CEO), Jens Passe TOM 1.8.4.1

GSM Test Report No. 6-0541-14-1-2b Annex B: Test Equipment Date of Report: 2014-06-04 TOM 1.8.4.1 Page 2 of 5 1. Test Equipment Location Testing was performed at the following marked location: 1.1 Location "Essen" Address: CETECOM GmbH 45219 Essen Germany 1.2 Location "Milpitas, CA" Address: CETECOM Inc. 411 Dixon Landing Road Milpitas, CA U.S.A. 95035 1.3 Location "San Diego, CA" Address: CETECOM Inc. - Branch San Diego 6370 Nancy Ridge Drive, Suite 101 San Diego, CA U.S.A 92121 1.4 Location "Anyang-si" Address: CETECOM MOVON Ltd. RN. 221, Dusanventuredigm Bldg., 415 Heungan-daero, Dongan-gu, Anyang-si, Gyeonggi-do Korea 431-755

GSM Test Report No. 6-0541-14-1-2b Annex B: Test Equipment Date of Report: 2014-06-04 TOM 1.8.4.1 Page 3 of 5 2. List of Test Equipment 2.1 Anechoic Chamber ID: Anechoic Chamber [Ess 1] Location: Essen (1.1) Serialnumber: - Software version: Test Case Software: Firmware CMU version 3.10 Ambient Conditions: Temperature: 15 C - 35 C Rel. Humidity: 20% - 75% Calibration: 2.2 R&S CMU200 Due date for the next test equipment calibration: N/A ID: R&S CMU 200 [Ess 1] Location: Essen (1.1) Serialnumber: 832221/091 Hardware: CMU-B21 var02 CMU-B52 var02 CMU-K21 (GSM 900) CMU-K22 (GSM1800) CMU-K23 (GSM1900) CMU-K24 (GSM 850) Software version: Test Case Software: Firmware CMU version 3.10 Ambient Conditions: Temperature: 15 C - 35 C Rel. Humidity: 20% - 75% Calibration: Due date for the next test equipment calibration: 2011-03-19

GSM Test Report No. 6-0541-14-1-2b Annex B: Test Equipment Date of Report: 2014-06-04 TOM 1.8.4.1 Page 4 of 5 2.3 Additional Equipment for Testing the Radiated Spurious Emissions ID Loc Instrument / Equipment Type Manufacturer Serialnumber Expiry Date SE101E 1.1 Horn Antenna (Substitution Antenna) 3115 EMCO 9107-3699 SE102E 1.1 UltraLog.-Antenna HL562 Rohde & Schwarz 100248 SE103E 1.1 Notch Filter (GSM 900) WRCA 901,9/903,1ss Wainwright 3RR SE104E 1.1 High Pass Filter (GSM850/900) WHJ2200-4EE Wainwright 14 SE105E 1.1 Notch Filter (GSM1800) WRCB 1747/1748 Wainwright 12 SE106E 1.1 Notch Filter (GSM1900) WRCB 1879,5/1880,5EE Wainwright 15 SE107E 1.1 High Pass Filter (GSM1800, 1900, DECT) 5HC2600/12750-1.5-KK Trilithic Inc. 23042 SE108E 1.1 Preamplifier AMF-2D-100M4G-35-10P MITEQ 379418 SE111E 1.1 Biconilog Antenna (Measuring Antenna) CBL 6141A Schaffner-Chase 4107 SE112E 1.1 Horn Antenna (Measuring Antenna) 3115 EMCO 9012-3629 SE113E 1.1 Biconical Antenna (Substitution Antenna) HUF-Z2 Rohde & Schwarz 863.029/010 SE116E 1.1 Signal Generator SMHU Rohde & Schwarz 831314/006 SE117E 1.1 Power Meter NRV-S Rohde & Schwarz 825770/0010 SE118E 1.1 Peak Power Sensor NRV-Z31 Rohde & Schwarz 843383/016 SE119E 1.1 Notch Filter (GSM850) WRCA 800/960-02/40-6EEK Wainwright 24 SE141E 1.1 Spectrum Analyser FSEK30 Rohde & Schwarz 826939/005 SE150E 1.1 Log.-Per. Antenna (Subst 1) 3146 EMCO 860941/007 SE151E 1.1 Signal Generator SMP04 Rohde & Schwarz 826190/0007 SE152E 1.1 System CTC-FAR-EMI-Spuri - CETECOM N/A SE153E 1.1 Pre-Amplifier 2.5-18GHz AMF-5D-02501800-25-10P MITEQ 1244554

GSM Test Report No. 6-0541-14-1-2b Annex B: Test Equipment Date of Report: 2014-06-04 TOM 1.8.4.1 Page 5 of 5 ID Loc Instrument / Equipment Type Manufacturer Serialnumber Expiry Date SE154E 1.1 Log.-Per. Antenna HL025 Rohde & Schwarz 1000060 SE155E 1.1 High Pass Filter 2.8-18GHz WHKX 2.8/18G-10SS Wainwright 4 SE156E 1.1 UltraLog.-Antenna HL562 Rohde & Schwarz 830547/009 SE157E 1.1 Peak Power Sensor NRV-Z1 Rohde & Schwarz 861761/002

THIS TEST REPORT IS NOT INTENDED FOR PTCRB OR CTIA CERTIFICATION! GSM (Global System for Mobile Communications) TEST REPORT Number: 6-0541-14-1-2b - Date: 2014-06-04 for Philips Innovation Services User Equipment Type: City Touch OLC Final Hardware Version: - Final Software Version: - - Annex C: Photographs This annex consists of 3 pages CETECOM GmbH is accredited according to DIN EN ISO/IEC 17025 by: CETECOM GmbH 45219 Essen Germany Phone: +49 (0) 2054 9519-0 Fax: +49 (0) 2054 9519-220 E-mail: info@cetecom.com http://www.cetecom.com Registered in Essen, Germany, Reg.-No.: HRB Essen 8984 Managing Directors: Wilfried Klassmann (CEO), Jens Passe TOM 1.8.4.1

GSM Test Report No. 6-0541-14-1-2b Annex C: Photographs Date of Report: 2014-06-04 TOM 1.8.4.1 Page 2 of 3 1. Photographs of the Equipment Under Test 1.1 RSE setup close up view 1.2 RSE setup long shot view

GSM Test Report No. 6-0541-14-1-2b Annex C: Photographs Date of Report: 2014-06-04 TOM 1.8.4.1 Page 3 of 3 1.3 Philips Power Box LLC7240 9137 003 608 1.4 Philips Comm Box LLC7251 9137 003 607

GSM (Global System for Mobile Communications) TEST REPORT Number: 6-0541-14-1-2b - Date: 2014-06-04 for Philips Innovation Services User Equipment Type: City Touch OLC Final Hardware Version: - Final Software Version: - - Annex D: Detailed Test Verdicts This annex consists of 6 pages CETECOM GmbH is accredited according to DIN EN ISO/IEC 17025 by: CETECOM GmbH 45219 Essen Germany Phone: +49 (0) 2054 9519-0 Fax: +49 (0) 2054 9519-220 E-mail: info@cetecom.com http://www.cetecom.com Registered in Essen, Germany, Reg.-No.: HRB Essen 8984 Managing Directors: Wilfried Klassmann (CEO), Jens Passe TOM 1.8.4.1

GSM Test Report No. 6-0541-14-1-2b Annex D: Detailed Test Verdicts Date of Report: 2014-06-04 TOM 1.8.4.1 Page 2 of 6 Contents Page 1. General Description 3 2. Terms used in the Test Result Table 3 2.1 Main Terms 3 2.2 Terms in Column "Verdict" 4 2.3 Terms in Column "Notes" 5 3. Detailed Results 5 3.1 Test Results according to 3GPP TS 51.010-1 6

GSM Test Report No. 6-0541-14-1-2b Annex D: Detailed Test Verdicts Date of Report: 2014-06-04 TOM 1.8.4.1 Page 3 of 6 1. General Description This annex of the GSM test report includes tables with detailed test results of the equipment under test (EUT). 2. Terms used in the detailed test result table This section defines the terms which are used in the enclosed detailed test result tables. 2.1 Main Terms The following main terms are used in the detailed test result tables: Term Notes Explanation Information about testing locations, used test samples, special test situations, special test setups or special interpretations of the test results. See section 2.3 of this annex for detailed information.

GSM Test Report No. 6-0541-14-1-2b Annex D: Detailed Test Verdicts Date of Report: 2014-06-04 TOM 1.8.4.1 Page 4 of 6 2.2 Terms in column "Verdict" The following terms are used in the detailed test result tables to identify the verdicts of each test case in the given GSM frequency bands: Verdict PASS Explanation EUT has been tested at CETECOM's (own or subcontracted) laboratories and is conformant to the applied standards for this test case in the given GSM frequency band. FAIL PASS/---- INC. N/A N/R R NO GSM850 GSM900 GSM1800 GSM1900 EUT has been tested at CETECOM's (own or subcontracted) laboratories but is not conformant to the applied standards for this test case in the given GSM frequency band. For not completely validated tests only the validated parts of the test are "PASS" as mentioned above. "Inconclusive": EUT has been tested at CETECOM's (own or subcontracted) laboratories but the test verdict for this test case in the given GSM frequency band is ambiguous. Detailed explanation is given in the note for the corresponding test case. "Not Applicable": According to the client's and/or manufacturer's documentation (PICS/PIXIT) this test is not applicable in the given GSM frequency band or the test case is not applicable according to an exception which is documented in the corresponding "Additional Reference Documents for Testing". (listed in test report section 2.3.2). "Not Required": This test case is not required for conformance testing in the given frequency band due to special rules accepted in the corresponding certification regime. Examples:- Test case only needs to be tested in one single frequency band - Test case only needs to be tested with limited parameters or settings - Test case has exceptions (e.g. due to test specification or test platform faults) - Test case is waived by the certification committee "Redundant": This test has not been performed in the given GSM frequency band but the test requirement has been verified by means of another test case (e.g. in an other technology). This test has not been performed with the EUT in the given GSM frequency band and/or with the given test parameter(s) although the test may be mandatory for conformance testing. This test has not been performed in the given GSM frequency band but in the GSM 850 frequency band instead. The result for this test is given in the appropriate column for "GSM 850". This test has not been performed in the given GSM frequency band but in the GSM 900 frequency band instead. The result for this test is given in the appropriate column for "GSM 900". This test has not been performed in the given GSM frequency band but in the GSM 1800 frequency band instead. The result for this test is given in the appropriate column for "GSM 1800". This test has not been performed in the given GSM frequency band but in the GSM 1900 frequency band instead. The result for this test is given in the appropriate column for "GSM 1900". ---- Test is not defined or not validated in the given GSM frequency band or not used by the specific certification regime.

GSM Test Report No. 6-0541-14-1-2b Annex D: Detailed Test Verdicts Date of Report: 2014-06-04 TOM 1.8.4.1 Page 5 of 6 2.3 Terms in column "Notes" 2.3.1 Test samples used for testing The detailed test result table contains numerical notes (e.g. "1,4,...") to identify the EUT test samples used for each performed test case. These numerical notes directly refer to the corresponding EUT identifier defined in section 3.3 of the test report (e.g. note "1,4" indicates that the given test case in the given GSM frequency band has been tested with both user equipment test samples identified as EUT1 and EUT4). 2.3.2 Special Test Situations, Test Setups and Verdict Interpretations The detailed test result table may also contain letter notes (e.g. "A,C,...") to identify special test situations, special test setups or special interpretations for the given test case. The following letter notes are used: Note --- no letter note used --- Explanation 3. Detailed Test Result Table The test result table in the following section includes detailed information for all performed test cases.

GSM Test Report No. 6-0541-14-1-2b Annex D: Detailed Test Verdicts Date of Report: 2014-06-04 TOM 1.8.4.1 Page 6 of 6 3.1 Test Results according to 3GPP TS 51.010-1 Test Results of Philips Innovation Services City Touch OLC Test Case 3GPP TS 51.010-1 Requirement ETSI EN 301 511 (v9.0.2) Test Description ETSI EN 301 511 (v9.0.2) GSM 900 GSM 1800 Verdict Notes Verdict Notes Radiated spurious emissions - MS allocated a channel ------- --- ------- --- 12.2.1 Normal Temperature \ Normal Voltage PASS 1 PASS 1 Normal Temperature \ Low Voltage N/R --- N/R --- Normal Temperature \ High Voltage N/R --- N/R --- Radiated spurious emissions - MS in idle mode ------- --- ------- --- 12.2.2 Normal Temperature \ Normal Voltage PASS 1 PASS 1 Normal Temperature \ Low Voltage N/R --- N/R --- Normal Temperature \ High Voltage N/R --- N/R --- Please refer to GSM test report Annex E section 2 for detailed information of the used terms and notes.

THIS TEST REPORT IS NOT INTENDED FOR PTCRB OR CTIA CERTIFICATION! GSM (Global System for Mobile Communications) TEST REPORT Number: 6-0451-14-1-2b - Date: 2014-06-04 for Philips Innovation Services User Equipment Type: City Touch OLC Final Hardware Version: - Final Software Version: - - Annex E: Measurement Results This annex consists of 8 pages CETECOM GmbH is accredited according to DIN EN ISO/IEC 17025 by: CETECOM GmbH 45219 Essen Germany Phone: +49 (0) 2054 9519-0 Fax: +49 (0) 2054 9519-220 E-mail: info@cetecom.com http://www.cetecom.com Registered in Essen, Germany, Reg.-No.: HRB Essen 8984 Managing Directors: Wilfried Klassmann (CEO), Jens Passe TOM 1.8.4.1

This Report shall not be reproduced except in full without the written approval of CETECOM Copyright All rights reserved by CETECOM Test Report No. 6-0541-13-1-2b Annex E: Measurement Results Date of Report: 2014-06-04 Tom 1.8.2.4.1 Page 2 of 8 D-45219 Essen CarrierCheck_GSM900 Common Information Test Description: GSM900 - ERP Carrier Measurement Test Site Location: CETECOM GmbH Essen Test Site: Fully Anechoic Room (FAR) Test Standard: 3GPP TS51.010-1 Test Case: TC12.2.1 Operating Mode: MS allocated channel 62 (fc = 902.4MHz), GPRS, 1 UL, Gamma 3 (+33dBm) Environmental Conditions: Humidity: 57%rH; Temperature: 20 C Operator: FSc/MFr EUT Information Manufacturer: Philips Innovation Services EuT: City Touch OLC ----------------------------------------- --------------------------------------------- HW Version: SW Version: Serial Number: Connected Interfaces: LED Panel, Lamp Driver Power Supply: 230 V AC Comments: 0 3 0 8 2 2 f_ T S 5 1.0 1 0 _ GS M 9 0 0 _ Ca rrie r_ c h 6 2 _ GP R S _ CM U _ R F3 _ R F4 40 30 20 Level in dbm 10 0-10 -20-30 -40 890 895 900 905 910 915 Fre q u e n c y in M H z Final Result 1 Frequency MaxPeak (MHz) (dbm) Meas. Time (ms) Bandwidth (khz) Polarization Azimuth (deg) Elevation (deg) Corr. (db) 902.510020 26.4 1000.0 1000.000 V 60.0 90.0-75.3 Comm ent

This Report shall not be reproduced except in full without the written approval of CETECOM Copyright All rights reserved by CETECOM Test Report No. 6-0541-13-1-2b Annex E: Measurement Results Date of Report: 2014-06-04 Tom 1.8.2.4.1 Page 3 of 8 D-45219 Essen 8.01_TC12.2.1_GSM900_nomVolt Common Information Test Description: Radiated Spurious Emissions E-GSM900 Test Site Location: CETECOM GmbH Essen Test Site: Fully Anechoic Room (FAR) Test Standard: 3GPP TS51.010-1 Test Case: TC12.2.1 Operating Mode: MS allocated channel 62 (fc = 902.4MHz), GPRS, 1 UL, Gamma 3 (+33dBm) Exclusionband: 900.6-904.2MHz Environmental Conditions: Humidity: 57%rH; Temperature: 20 C Operator: FSc/MFr EUT Information Manufacturer: Philips Innovation Services EuT: City Touch OLC ----------------------------------------- --------------------------------------------- HW Version: SW Version: Serial Number: Connected Interfaces: LED Panel, Lamp Driver Power Supply: 230 V AC Comments: 0 3 0 6 0 2 f_ T S 5 1.0 1 0 _ GS M 9 0 0 _ T C1 2.2.1 _ 3 0 M _ 6 G_ G P R S _ C M U _ R F3 _ R F4-20 -25-30 -35-40 -45 946,873748 MHz -42,974 dbm 1,569138277 GHz -47,053 dbm 1,805611222 GHz -43,584 dbm Level in dbm -50-55 -60-65 -70-75 -80-85 -90 0,03 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 Fre q u e n c y in G H z

This Report shall not be reproduced except in full without the written approval of CETECOM Copyright All rights reserved by CETECOM Test Report No. 6-0541-13-1-2b Annex E: Measurement Results Date of Report: 2014-06-04 Tom 1.8.2.4.1 Page 4 of 8 D-45219 Essen 8.04_TC12.2.2_IDLE_GSM900_nomVolt Common Information Test Description: Radiated Spurious Emissions GSM900 Test Site Location: CETECOM GmbH Essen Test Site: Fully Anechoic Room (FAR) Test Standard: 3GPP TS51.010-1 Test Case: TC12.2.2 Operating Mode: MS in idle mode Environmental Conditions: Humidity: 71%rH; Temperature: 19 C Comments: Downlink at 947,4MHz Operator: FSc/MFr EUT Information Manufacturer: Philips Innovation Services EuT: City Touch OLC ----------------------------------------- --------------------------------------------- HW Version: SW Version: Serial Number: Connected Interfaces: LED Panel, Lamp Driver Power Supply: 230 V AC Comments: 030606d_TS51.010_GSM900_TC12.2.2_30M_6G_PD_CMU_RF3_4-12 -20-30 Level in dbm -40-50 -60-70 947,767535 MHz -46,993 dbm -80-92 0,03 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 Final Result 1 Frequency MaxPeak (MHz) (dbm) Meas. Time (ms) Bandwidth (khz) Fre q u e n c y in G H z Polarization Azimuth (deg) Elevation (deg) Corr. (db) Margin (db) Limit (dbm) 65.641282-68.2 5000.0 100.000 V 60.0 0.0-115.6 11.2-57.0 83.176353-67.6 5000.0 100.000 H -12.0 90.0-113.1 10.6-57.0 93.224449-73.1 5000.0 100.000 V 75.0 0.0-113.1 16.1-57.0 116.997996-72.7 5000.0 100.000 H -6.0 0.0-112.9 15.7-57.0 150.426854-76.8 5000.0 100.000 H 150.0 0.0-115.5 19.8-57.0 577.565131-67.2 5000.0 100.000 V 119.0 90.0-107.0 10.2-57.0 587.416834-64.9 5000.0 100.000 H 90.0 90.0-106.8 7.9-57.0 601.825651-62.7 5000.0 100.000 H 93.0 0.0-106.7 5.7-57.0 613.907816-60.7 5000.0 100.000 H 93.0 0.0-106.5 3.7-57.0 624.102204-60.8 5000.0 100.000 H 96.0 0.0-106.4 3.8-57.0 636.058116-61.5 5000.0 100.000 H 103.0 0.0-106.2 4.5-57.0 647.947896-62.9 5000.0 100.000 H 103.0 0.0-106.1 5.9-57.0 659.376754-65.5 5000.0 100.000 V 20.0 90.0-105.7 8.5-57.0 672.162325-67.3 5000.0 100.000 V 22.0 90.0-105.8 10.3-57.0 889.509018-69.0 5000.0 100.000 H 42.0 0.0-103.2 10.0-59.0 900.018037-68.9 5000.0 100.000 H 51.0 0.0-103.2 9.9-59.0 913.591182-68.8 5000.0 100.000 H 69.0 0.0-102.9 9.8-59.0

This Report shall not be reproduced except in full without the written approval of CETECOM Copyright All rights reserved by CETECOM Test Report No. 6-0541-13-1-2b Annex E: Measurement Results Date of Report: 2014-06-04 Tom 1.8.2.4.1 Page 5 of 8 D-45219 Essen CarrierCheck_GSM1800 Common Information Test Description: Test Site Location: Test Site: Test Standard: Test Case: Operating Mode: GSM1800 - ERP Carrier Measurement CETECOM GmbH Essen Fully Anechoic Room (FAR) 3GPP TS51.010-1 TC12.2.1 MS allocated channel 700 (fc = 1747.8 MHz), GPRS, 1 UL, Gamma 3 (+30dBm) Environmental Conditions: Humidity: 57%rH; Temperature: 20 C Operator: GAr/MFr/KMo EUT Information Manufacturer: Philips Innovation Services EuT: City Touch OLC ----------------------------------------- --------------------------------------------- HW Version: SW Version: Serial Number: Connected Interfaces: LED Panel, Lamp Driver Power Supply: 230 V AC Comments: 0 3 0 8 2 3 f_ T S 5 1.0 1 0 _ GS M 1 8 0 0 _ Ca rrie r_ c h 7 0 0 _ G P R S _ CM U _ R F3 _ R F4 40 30 20 Level in dbm 10 0-10 -20-30 -40 1741 1742 1744 1746 1748 1750 1752 1754 Fre q u e n c y in M H z Final Result 1 Frequency MaxPeak (MHz) (dbm) Meas. Time (ms) Bandwidth (khz) Polarization Azimuth (deg) Elevation (deg) Corr. (db) 1747.748497 27.4 5000.0 1000.000 H 88.0 0.0-65.8 Comm ent

This Report shall not be reproduced except in full without the written approval of CETECOM Copyright All rights reserved by CETECOM Test Report No. 6-0541-13-1-2b Annex E: Measurement Results Date of Report: 2014-06-04 Tom 1.8.2.4.1 Page 6 of 8 D-45219 Essen 8.02_TC12.2.1_GSM1800_nomVolt Common Information Test Description: Test Site Location: Test Site: Test Standard: Test Case: Operating Mode: Radiated Spurious Emissions GSM1800 CETECOM GmbH Essen Fully Anechoic Room (FAR) 3GPP TS51.010-1 TC12.2.1 MS allocated channel 700 (fc = 1747.8 MHz), GPRS, 1 UL, Gamma 3 (+30dBm) Exclusionband: 1746.0-1749.6MHz Environmental Conditions: Humidity: 57%rH; Temperature: 20 C Operator: GAr/Kmo/MFr EUT Information Manufacturer: Philips Innovation Services EuT: City Touch OLC ----------------------------------------- --------------------------------------------- HW Version: SW Version: Serial Number: Connected Interfaces: LED Panel, Lamp Driver Power Supply: 230 V AC Comments: 0 3 0 6 0 3 f_ T S 5 1.0 1 0 _ GS M 1 8 0 0 _ T C1 2.2.1 _ 3 0 M _ 6 G_ G P R S _ C M U _ R F3 _ R F4-20 -30-40 1,842635271 GHz -43,331 dbm Level in dbm -50-60 -70-80 -90 0,03 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 Fre q u e n c y in G H z Final Result 1 Frequency MaxPeak (MHz) (dbm) Meas. Time (ms) Bandwidth (khz) Polarization Azimuth (deg) Elevation (deg) Corr. (db) Margin (db) Limit (dbm) 3495.185371-39.3 5000.0 3000.000 H 107.0 0.0-95.7 9.3-30.0 5243.311623-33.0 5000.0 3000.000 V 307.0 0.0-90.8 3.0-30.0

This Report shall not be reproduced except in full without the written approval of CETECOM Copyright All rights reserved by CETECOM Test Report No. 6-0541-13-1-2b Annex E: Measurement Results Date of Report: 2014-06-04 Tom 1.8.2.4.1 Page 7 of 8 D-45219 Essen 8.03_TC12.2.2_IDLE_GSM1800_nomVolt Common Information Test Description: Radiated Spurious Emissions GSM1800 Test Site Location: CETECOM GmbH Essen Test Site: Fully Anechoic Room (FAR) Test Standard: 3GPP TS51.010-1 Test Case: TC12.2.2 Operating Mode: MS in idle mode Environmental Conditions: Humidity: 57%rH; Temperature: 20 C Comments: Downlink at 1842,8MHz Operator: GAr/Kmo/MFr EUT Information Manufacturer: Philips Innovation Services EuT: City Touch OLC ----------------------------------------- --------------------------------------------- HW Version: SW Version: Serial Number: Connected Interfaces: LED Panel, Lamp Driver Power Supply: 230 V AC Comments: 030607d_TS51.010_GSM1800_TC12.2.2_30M _6G_PD_CMU_RF3_4-20 -30-40 1,841953908 GHz -45,055 dbm Level in dbm -50-60 -70-80 -90-100 0,03 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 Fre q u e n c y in G H z Final Result 1 Frequency MaxPeak (MHz) (dbm) Meas. Time (ms) Bandwidth (khz) Polarization Azimuth (deg) Elevation (deg) Corr. (db) Margin (db) Limit (dbm) 66.082164-62.2 5000.0 100.000 V -46.0 0.0-115.5 5.2-57.0 82.915832-65.1 5000.0 100.000 H -2.0 0.0-113.1 8.1-57.0 92.328657-66.4 5000.0 100.000 V 103.0 90.0-113.1 9.4-57.0 136.400802-71.3 5000.0 100.000 H 15.0 0.0-114.4 14.3-57.0

This Report shall not be reproduced except in full without the written approval of CETECOM Copyright All rights reserved by CETECOM Test Report No. 6-0541-13-1-2b Annex E: Measurement Results Date of Report: 2014-06-04 Tom 1.8.2.4.1 Page 8 of 8 D-45219 Essen 8.03a_TC12.2.2_IDLE_GSM1800_nomVolt Common Information Test Description: Radiated Spurious Emissions GSM1800 Test Site Location: CETECOM GmbH Essen Test Site: Fully Anechoic Room (FAR) Test Standard: 3GPP TS51.010-1 Test Case: TC12.2.2 Operating Mode: MS in idle mode Environmental Conditions: Humidity: 71%rH; Temperature: 19 C Comments: Downlink at 1842,8MHz Operator: FSc/MFr/KTa EUT Information Manufacturer: Philips Innovation Services EuT: City Touch OLC ----------------------------------------- --------------------------------------------- HW Version: SW Version: Serial Number: Connected Interfaces: LED Panel, Lamp Driver Power Supply: 230 V AC Comments: 030607d_TS51.010_GSM1800_TC12.2.2_30M _6G_PD_CMU_RF3_4-20 -30-40 Level in dbm -50-60 -70-80 -90-100 30 200 400 600 800 1000 Fre q u e n c y in M H z Final Result 1 Frequency MaxPeak (MHz) (dbm) Meas. Time (ms) Bandwidth (khz) Polarization Azimuth (deg) Elevation (deg) Corr. (db) Margin (db) Limit (dbm) 57.883768-72.3 5000.0 100.000 V -18.0 0.0-116.2 15.3-57.0 65.955912-68.1 5000.0 100.000 V 13.0 0.0-115.5 11.1-57.0 83.791583-69.2 5000.0 100.000 H -1.0 0.0-113.0 12.2-57.0 91.915832-72.1 5000.0 100.000 H -22.0 90.0-113.1 15.1-57.0 117.082164-73.6 5000.0 100.000 H -4.0 0.0-112.9 16.6-57.0 117.747495-73.4 5000.0 100.000 H 189.0 90.0-112.9 16.4-57.0 120.424850-74.3 5000.0 100.000 H 189.0 0.0-113.0 17.3-57.0 124.196393-74.7 5000.0 100.000 H 186.0 90.0-113.0 17.7-57.0 149.703407-76.1 5000.0 100.000 H 179.0 90.0-115.5 19.1-57.0 150.272545-76.4 5000.0 100.000 H 179.0 0.0-115.5 19.4-57.0 152.200401-73.8 5000.0 100.000 H 196.0 90.0-115.6 16.8-57.0 163.993988-78.4 5000.0 100.000 H 186.0 90.0-115.9 21.4-57.0